Frequency tracked gated pulse technique for ultrasonic frequency

A tracking generator 21 is slaved to a spectrum analyzer 23 to produce an input signal having a frequency that follows the frequency of the spectrum analyzer sweeping local oscillator 22. The input signal is gated to a transducer 26 by a transmitter gate 25 to produce ultrasonic waves in the sample 28. The resulting ultrasonic echoes are converted into electrical signals by the transducer and then gated into the spectrum analyzer by receiver gate 29. This arrangement produces spectra that are equivalent to shock-exciting the transducer with a true delta function shock-excitation.

Cantrell, Jr., John H.↗

Exact transition probabilities for a linear sweep through a Kramers-Kronig resonance

We consider a localized electronic spin controlled by a circularly polarized optical beam and an external magnetic field. When the frequency of the beam is tuned near an optical resonance with a continuum of higher energy states, effective magnetic fields are induced on the two-level system via the inverse Faraday effect. We explore the process in which the frequency of the beam is made linearly time-dependent so that it sweeps through the optical resonance, starting and ending at the values far away from it. In addition to changes of spin states, Kramers-Kronig relations guarantee that a localized electron can also escape into a continuum of states. We argue that probabilities of transitions between different possible electronic states after such a sweep of the optical frequency can be found exactly, regardless the shape of the resonance. In conclusion, we also discuss extension of our results to multistate systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration of a 32 channel electron cyclotron emission radiometer on the HL-2A tokamak

A novel 32-channel electron cyclotron emission radiometer has been designed and tested for the measurement of electron temperature profiles on the HL-2A tokamak. This system is based on the intermediate frequency filter detection technique, and has the features of wide working frequency range and high spatial resolution. Two relative calibration methods have been investigated: sweeping the toroidal magnetic field and hopping the output frequency of the local oscillator. Preliminary results show that both methods can ensure reasonable profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and Validation of an Initial Electric Motor Rotor Vibration Model

An overview of the development of a low fidelity prediction tool for electric motor rotor resonant modes and frequencies. These predictions are useful for the prediction of UAM motor noise during the design phase. Finite Element Analysis of motor rotors has led to the development of a parameterized model to predict these modes shapes. This has in turn allowed to a curve-fit based model from parametric sweeps. These curves can predict resonant frequencies and shapes for 1-5kW class motors without running a simulation.

acoustics↗

Implicit Large-Eddy Simulation of Axisymmetric and Asymmetric Turbulent Shock Wave Boundary Layer Interaction at Mach 2.5

High-speed inlet flows feature turbulent shock wave boundary layer interactions at supersonic Mach numbers. A canonical Mach 2.5 shock wave boundary layer interaction experiment at the NASA Glenn Research Center was designed for axisymmetric and asymmetric interactions depending on the placement of the shock generator. Four different wall-resolved implicit large-eddy simulations of the experiment were carried out at one-tenth of the Reynolds number of the experiment: (1) Two axisymmetric interactions with shock generator radii of 9.2% and 14.7% of the test section diameter and (2) two asymmetric interactions with 14.7% shock generator radius and shock generator centerline offsets of one-third and one-fourth of the test section radius. For the two axisymmetric interactions, various sub-domains upstream of the interaction, within the interaction, and downstream of the interaction were analyzed with the proper orthogonal decomposition. For all three regions, the dominant modes are streamwise coherent structures with Strouhal numbers based on separation length of 0.15 and below. Fourier spectra of the wall-pressure coefficient for the interaction region have peaks at Strouhal numbers based on separation length of 0.15 and 0.04. For the two asymmetric interactions, the streamwise extent of the separation varies considerably in the azimuthal direction. For both shock generator offsets, the interaction is strongest for the azimuthal location that is closest to the shock generator. Compared to the axisymmetric interaction, the streamwise extent of the separated flow region is noticeably reduced and a substantial crossflow is observed. Fourier analyses of the unsteady flow indicate low-frequency content f or the upstream part of the interaction which is more two-dimensional. Away from the upstream region, with increasing sweep angle and crossflow, the low-frequency content is diminished.

Computational Fluid Dynamics↗

Multiplexed gas spectroscopy using tunable VCSELs

Detection and identification of gas species using tunable laser diode laser absorption spectroscopy has been performed using vertical cavity surface emitting lasers (VCSEL). Two detection methods are compared: direct absorbance and wavelength modulation spectroscopy (WMS). In the first, the output of a DC-based laser is directly monitored to detect for any quench at the targeted specie wavelength. In the latter, the emission wavelength of the laser is modulated by applying a sinusoidal component on the drive current of frequency {omega}, and measuring the harmonics component (2{omega}) of the photo-detected current. This method shows a better sensitivity measured as signal to noise ratio, and is less susceptible to interference effects such as scattering or fouling. Gas detection was initially performed at room temperature and atmospheric conditions using VCSELs of emission wavelength 763 nm for oxygen and 1392 nm for water, scanning over a range of approximately 10 nm, sufficient to cover 5-10 gas specific absorption lines that enable identification and quantization of gas composition. The amplitude and frequency modulation parameters were optimized for each detected gas species, by performing two dimensional sweeps for both tuning current and either amplitude or frequency, respectively. We found that the highest detected signal is observed for a wavelength modulation amplitude equal to the width of the gas absorbance lines, in good agreement with theoretical calculations, and for modulation frequencies below the time response of the lasers (<50KHz). In conclusion, we will discuss limit of detection studies and further implementation and packaging of VCSELs in diode arrays for continuous and simultaneous monitoring of multiple species in gaseous mixtures.

42 ENGINEERING↗

Modal Test of the NASA Mobile Launcher at Kennedy Space Center

The NASA Mobile Launcher (ML), located at Kennedy Space Center (KSC), has recently been modified to support the launch of the new NASA Space Launch System (SLS). The ML is a massive structure—consisting of a 345-foot tall tower attached to a two-story base, weighing approximately 10.5 million pounds—that will secure the SLS vehicle as it rolls to the launch pad on a Crawler Transporter, as well as provide a launch platform at the pad. The ML will also provide the boundary condition for an upcoming SLS Integrated Modal Test (IMT). To help correlate the ML math models prior to this modal test, and allow focus to remain on updating SLS vehicle models during the IMT, a ML-only experimental modal test was performed in June 2019. Excitation of the tower and platform was provided by five uniquely-designed test fixtures, each enclosing a hydraulic shaker, capable of exerting thousands of pounds of force into the structure. For modes not that were not sufficiently excited by the test fixture shakers, a specially-designed mobile drop tower provided impact excitation at additional locations of interest. The response of the ML was measured with a total of 361 accelerometers. Following the random vibration, sine sweep vibration, and modal impact testing, frequency response functions were calculated and modes were extracted for three different configurations of the ML in 0 Hz to 12 Hz frequency range. This paper will provide a case study in performing modal tests on large structures by discussing the Mobile Launcher, the test strategy, an overview of the test results, and recommendations for meeting a tight test schedule for a large-scale modal test.

Hydraulic shakers↗

A fast Huygens sweeping method for capturing paraxial multi-color optical self-focusing in nematic liquid crystals

We propose a numerically efficient algorithm for simulating the multi-color optical self-focusing phenomena in nematic liquid crystals. The propagation of the nematicon is modeled by a parabolic wave equation coupled with a nonlinear elliptic partial differential equation governing the angle between the crystal and the direction of propagation. Numerically, the paraxial parabolic wave equation is solved by a fast Huygens sweeping method, while the nonlinear elliptic PDE is handled by the alternating direction explicit (ADE) method. The overall algorithm is shown to be numerically efficient for computing high frequency beam propagations. - Highlights: • A simple strategy can already improve the fast Huygens sweeping method for high frequency asymptotic solutions. • The Alternating Direction Explicit method can significant improve the computational efficiency. • Numerical solutions match the Fredericks transition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Double-sided electron energy analyzer for measurement of non-Maxwellian electron energy distributions

Here, a double-sided electron energy analyzer is developed for studies of magnetic reconnection. It can measure electron energy distribution functions along two directions opposite to each other at the same time. Each side is composed of a floating reference grid, an energy selector grid, and a collector plate. The voltage of the selector grid is swept from –40 to 0 V with respect to the reference grid with a frequency of 1 MHz. This fast sweeping is required to resolve sub-Alfvénic changes in plasma quantities of the Magnetic Reconnection Experiment, where the typical Alfvénic time is a few microseconds. The reliability of the energy analyzer is checked in Maxwellian plasmas away from the reconnection region. In this case, the electron temperature computed from the electron energy distribution function agrees with measurements of a reference triple Langmuir probe. When it is located near the reconnection region, the temperatures of the tail electron population from both sides, facing into the electron flow and facing away from it, exceed the bulk electron temperature measured by the Langmuir probe by a factor of about 2.

47 OTHER INSTRUMENTATION↗

Brady's Geothermal Field Nodal Seismometer Data

This submission includes links to raw data, field notes, metadata, and p-wave arrival auto-picks from processed data (not provided) from the nodal seismometer array deployed at the PoroTomo Natural Laboratory in Brady's Hot Springs, Nevada during the March 2016 testing. The data is available as continuous or windowed (to vibroseis sweep) files and is stored in an AWS S3 bucket. Note: No raw data was recovered from stations 73 and 82. These data are available for download without login credentials through the free and publicly accessible Open Energy Data Initiative (OEDI) data viewer which allows users to browse and download individual or groups of files.

15 GEOTHERMAL ENERGY↗

Note: Directly measuring the direct digital synthesizer frequency chirp-rate for an atom interferometer

During gravity measurements with Raman type atom interferometry, the frequency of the laser used to drive Raman transition is scanned by chirping the frequency of a direct digital synthesizer (DDS), and the local gravity is determined by precisely measuring the chip rate α of DDS. We present an effective method that can directly evaluate the frequency chirp rate stability of our DDS. By mixing a pair of synchronous linear sweeping signals, the chirp rate fluctuation is precisely measured with a frequency counter. The measurement result shows that the relative α instability can reach 5.7 × 10{sup −11} in 1 s, which is neglectable in a 10{sup −9} g level atom interferometry gravimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluid-kinetic modeling of a high power density radio frequency inductively coupled positive hydrogen ion source

High power density radio-frequency (RF) inductively coupled positive ion sources are attractive candidates for next-generation neutral beam injection (NBI) systems, where higher injected power and longer pulse lengths are desired without sacrificing source reliability. Operating at absorbed power densities of order $\gt 1~\mathrm{W\,cm}^{-3}$ places these sources in a regime with stronger gas heating, higher dissociation, and non-Maxwellian electron energy distributions. The Large Uniform Plasma for Ionizing Neutrals (LUPIN) is an RF inductively coupled plasma source designed to explore this high power density regime and to provide guidance for a positive ion source upgrade for the DIII-D NBI system. LUPIN is designed to operate at up to 20 kW of RF power at 2 MHz, coupling energy through a cylindrical quartz vessel to achieve target ion current densities of $2100\,\mathrm{A\,m}^{-2}$ . This paper presents fluid-kinetic modeling of LUPIN using the hybrid plasma equipment model where electrons are treated kinetically, and the simulations reveal that electron energy distribution function transitions from nearly Maxwellian in the core to bi-Maxwellian towards the edge. Parametric simulations investigate the effects of RF power, gas pressure, and frequency on plasma density, ion flux, and uniformity. Parametric sweeps reveal that increasing power shifts the primary ionization channel from molecular to atomic with diminishing flux gains due to skin-depth contraction and gas rarefaction. Higher frequency localizes heating and increases $\mathrm{H}_2^+$ and $\mathrm{H}_3^+$ delivery to the grid, while elevated pressure boosts ionization yet hinders ion transport due to increase in collisionality.

inductively coupled plasma↗

First application of a digital mirror Langmuir probe for real-time plasma diagnosis

We report for the first time, a digital Mirror Langmuir Probe (MLP) has successfully sampled plasma temperature, ion saturation current, and floating potential together on a single probe tip in real time in a radio-frequency driven helicon linear plasma device. This is accomplished by feedback control of the bias sweep to ensure a good fit to I–V characteristics with a high frequency, high power digital amplifier, and field-programmable gate array controller. Measurements taken by the MLP were validated by a low speed I–V characteristic manually collected during static plasma conditions. Plasma fluctuations, induced by varying the axial magnetic field($\widetilde{f}$ = 10 Hz), were also successfully monitored with the MLP. Further refinement of the digital MLP pushes it toward a turn-key system that minimizes the time to deployment and lessens the learning curve, positioning the digital MLP as a capable diagnostic for the study of low radio-frequency plasma physics. These demonstrations bolster confidence in fielding such digital MLP diagnostics in magnetic confinement experiments with high spatial and adequate temporal resolution, such as edge plasma, scrape-off layer, and divertor probes.

47 OTHER INSTRUMENTATION↗

Developing New Q-meters for NMR Measurements of Polarized Solids

Enhanced polarization of target nuclei can be measured via the complex impedance of a resonant circuit coupled to the target while sweeping the circuit through the nuclear Larmor frequency, observing the absorption or emission of energy by the spins in the material. For decades, solid polarized targets at Jefferson Lab have relied upon continuous-wave Nuclear Magnetic Resonance polarization measurements using Liverpool Q-meter systems. These Liverpool Q-meters are no longer produced, and replacing the aging components is becoming increasingly difficult. The polarized target group at Bochum has produced replacement Q-meters in the Liverpool style using modern components, and we are following their example while researching improvemnts to the technique. We discuss our efforts to produce improved Q-meters for upcoming experiments utilizing solid polarized targets in Jefferson Lab's Hall B.

Maxwell, James↗

Aerodynamic Performance and Acoustic Impacts of Varying Tip Speeds and Tripping Conditions on Small Rotors in an Anechoic Hover Chamber

Performance and acoustic measurements were taken in a hover chamber for various optimum hovering rotors (OPT2) and a commercial-off-the-shelf (COTS) rotor. A total of 10 rotors are included in this report, all of which have two blades and a tip radius of 0.1905 m (7.5 in.). For the OPT2, results for three additive manufacturing methods of fabrication are presented: stereolithography(SLA) using Accura Xtreme, SLA using FormLabs 10K resin, and selective laser sintering (SLS) using mineral-filled PA12 nylon material. All but one set of rotors were designed with a trailing edge bluntness that is 3% of the chord length, and one set was designed with a bluntness that is 1% of the chord length. Spanwise boundary layer trips were applied to the SLA, FormLabs and COTS rotors. Performance comparisons between untripped and tripped configurations demonstrate the impact of boundary layer state on rotor efficiency. Acoustic results, including periodic and broadband noise components, are presented. The effects of tripping these rotors near the leading edge are also presented. For some of the rotors, acoustic spectra of tip speed sweeps are presented to show how the frequency content changes with tip speed. Amplitude and frequency scaling methods are used to collapse broadband spectra at various tip speeds towards a unified curve. These findings contribute to the understanding of small rotor aeroacoustics and provide valuable datasets for computational model validation in urban air mobility applications.

eVTOL↗

First application of a digital mirror Langmuir probe for real-time plasma diagnosis

For the first time, a digital Mirror Langmuir probe (MLP) has successfully sampled plasma temperature, ion saturation current, and floating potential together on a single probe tip in real time in a radio-frequency driven helicon linear plasma device. This is accomplished by feedback control of the bias sweep to ensure a good fit to I-V characteristics with a high frequency, high power digital amplifier and field-programmable gate array (FPGA) controller. Measurements taken by the MLP were validated by a low speed I-V characteristic manually collected during static plasma conditions. Plasma fluctuations, induced by varying the axial magnetic field (f̃ = 10 Hz), were also successfully monitored with the MLP. Further refinement of the digital MLP pushes it towards a turn-key system that minimizes the time to deployment and lessens the learning curve, positioning the digital MLP as a capable diagnostic for the study of low radio-frequency plasma physics. These demonstrations bolster confidence in fielding such digital MLP diagnostics in magnetic confinement experiments with high spatial and adequate temporal resolution such as edge plasma, scrape-off layer, and divertor probes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Automatic carrier acquisition system

An automatic carrier acquisition system for a phase locked loop (PLL) receiver is disclosed. It includes a local oscillator, which sweeps the receiver to tune across the carrier frequency uncertainty range until the carrier crosses the receiver IF reference. Such crossing is detected by an automatic acquisition detector. It receives the IF signal from the receiver as well as the IF reference. It includes a pair of multipliers which multiply the IF signal with the IF reference in phase and in quadrature. The outputs of the multipliers are filtered through bandpass filters and power detected. The output of the power detector has a signal dc component which is optimized with respect to the noise dc level by the selection of the time constants of the filters as a function of the sweep rate of the local oscillator.

Bunce, R. C.↗