At least 271 records · Page 15

Designing a Secure Storage Repository for Sharing Scientific Datasets using Public Clouds

As Cloud platforms gain increasing traction among scientific and business communities for outsourcing storage, computing and content delivery, there is also growing concern about the associated loss of control over private data hosted in the Cloud. In this paper, we present an architecture for a secure data repository service designed on top of a public Cloud infrastructure to support multi-disciplinary scientific communities dealing with personal and human subject data, motivated by the smart power grid domain. Our repository model allows users to securely store and share their data in the Cloud without revealing the plain text to unauthorized users, the Cloud storage provider or the repository itself. The system masks file names, user permissions and access patterns while providing auditing capabilities with provable data updates.

Kumbhare, Alok↗

A Software Defined Storage Approach to Exascale Storage Services (Final Technical Report)

The Mochi project began in 2015 in recognition of a set of changes that were set to alter the landscape of storage and I/O for DOE science. On the one hand, an influx of new classes of applications including an initial set of data intensive and machine learning applications were operating with new types of data and in new ways, as compared to traditional computational science simulation codes. Simultaneously, new memory, storage, and networking technologies were driving a need to adapt software designs to a rapidly changing design space. The goal of the three-year Mochi project was to develop and demonstrate an approach for composing storage services which provides new levels of functionality, performance, and reliability for science applications at extreme scale. The team, including a mix of Laboratory, university, and industry collaborators, focused on systems and applications of interest to DOE Office of Science, tracking developments at NERSC and the LCFs as well as application trends within ECP and SciDAC. Technical work focused on three themes: composition (understand the building blocks needed to provide storage services that meet DOE mission needs and how these components are flexibly composed), application interfacing (what service compositions are most effective for common DOE application use cases), and consistency and synchronization (taking advantage of knowledge about, and from, the system and scientific applications to provide better service than would otherwise be possible). The project was highly successful, producing 13 publications and tens of thousands of lines of open source software that is now being used by multiple ECP teams, HPC software vendors, and international collaborators. The uptake of Mochi technologies speaks to both the value of the service composition model and the quality of architecture and software developed by the team. Through continued funding under ASCR and ECP, the Mochi team and its technologies are on track to further contribute to DOE science successes into the exascale timeframe.

97 MATHEMATICS AND COMPUTING↗

Storage 2020: A Vision for the Future of HPC Storage

The explosive growth in data over the next five years that will accompany exascale simulations and new experimental detectors will enable new data-driven science across virtually every domain. At the same time, new nonvolatile storage technologies will enter the market in volume and upend long-held principles used to design the storage hierarchy. The disruption that these forces will bring to bear on high-performance computing (HPC) will also create significant opportunities to innovate and accelerate scientific discovery. To ensure that NERSC fully capitalizes on these opportunities, we have developed a comprehensive vision for the future of storage in HPC and identified short- and long-term strategic goals to effectively realize this vision. This report presents the results of this effort and offers a blueprint for designing a storage infrastructure for supporting HPC through 2025 and beyond.

97 MATHEMATICS AND COMPUTING↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Polymeric hydrogen diffusion barrier, high-pressure storage tank so equipped, method of fabricating a storage tank and method of preventing hydrogen diffusion

An electrochemically active hydrogen diffusion barrier which comprises an anode layer, a cathode layer, and an intermediate electrolyte layer, which is conductive to protons and substantially impermeable to hydrogen. A catalytic metal present in or adjacent to the anode layer catalyzes an electrochemical reaction that converts any hydrogen that diffuses through the electrolyte layer to protons and electrons. The protons and electrons are transported to the cathode layer and reacted to form hydrogen. The hydrogen diffusion barrier is applied to a polymeric substrate used in a storage tank to store hydrogen under high pressure. A storage tank equipped with the electrochemically active hydrogen diffusion barrier, a method of fabricating the storage tank, and a method of preventing hydrogen from diffusing out of a storage tank are also disclosed.

08 HYDROGEN↗

Development of graphite foam infiltrated with MgCl 2 for a latent heat based thermal energy storage (LHTES) system

Thermal energy storage (TES) systems that are compatible with high temperature power cycles for concentrating solar power (CSP) require high temperature media for transporting and storing thermal energy. To that end, TES systems have been proposed based on the latent heat of fusion of the phase change materials (PCMs). However, PCMs have relatively low thermal conductivities. In this paper, use of high-thermal-conductivity graphite foam infiltrated with a PCM (MgCl2) has been investigated as a potential TES system. Graphite foams with two porosities were infiltrated with MgCl2. The infiltrated composites were evaluated for density, heat of fusion, melting/freezing temperatures, and thermal diffusivities. Estimated thermal conductivities of MgCl2/graphite foam composites were significantly higher than those of MgCl2 alone over the measured temperature range. Furthermore, heat of fusion, melting/freezing temperatures, and densities showed comparable values to those of pure MgCl2. Results of this study indicate that MgCl2/graphite foam composites show promise as storage media for a latent heat thermal energy storage system for CSP applications.

25 ENERGY STORAGE↗

Assessment of Energy Storage Alternatives in the Puget Sound Energy System Volume 2: Energy Storage Evaluation Tool

This volume presents the battery storage evaluation tool developed at Pacific Northwest National Laboratory (PNNL), which is used to evaluate benefits of battery storage for multiple grid applications, including energy arbitrage, balancing service, capacity value, distribution system equipment deferral, and outage mitigation. This tool is based on the optimal control strategies to capture multiple services from a single energy storage device. In this control strategy, at each hour, a look-ahead optimization is first formulated and solved to determine battery base operating point. The minute by minute simulation is then performed to simulate the actual battery operation. This volume provide background and manual for this evaluation tool.

25 ENERGY STORAGE↗

Energy Storage Participation Algorithm Competition Overview: Market simulation, divisions, stages, storage attributes, and scoring

The Energy Storage Participation Algorithm Competition (ESPA-Comp) aims to assess the performance of participants’ battery storage offer algorithms on their ability to maximize the value of battery storage resources under three different market designs: two-settlement, multi-settlement, and rolling horizon forward markets. This document describes the overall design of the competition at a high level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Africa Battery Energy Storage Systems (BESS) Capacity Building Utility-Scale Storage: BESS Valuation, Tariffs, and Remuneration [Slides]

Utility-scale Battery Energy Storage Systems (BESS) are key to enhancing grid reliability, integrating renewable energy, and providing operational flexibility. Designing effective valuation, remuneration, and tariff frameworks is essential to ensure both system benefits and financial viability for developers. This presentation outlines a structured methodology for evaluating BESS projects, covering policy and legal considerations, cost and revenue analysis, benchmarking, financial sensitivity, and risk assessment, while ensuring alignment with public interest. It also explores valuation of multiple storage services - bulk energy, ancillary services, and infrastructure support - and monetization strategies through capacity payments, energy tariffs, tolling, arbitrage, and non-wires alternative payments. Technical factors, including round-trip efficiency, degradation, and storage duration, are integrated into financial and operational modeling to quantify both system-wide and project-level benefits. Through case studies and simulation-based approaches, this framework provides regulators, utilities, and developers with practical guidance for tariff design, payment structures, and investment decisions, maximizing the economic and societal value of BESS deployment.

25 ENERGY STORAGE↗

Successful Deployment of System for the Storage and Retrieval of Spent/Used Nuclear Fuel from Hanford K-West Fuel Storage Basin-13051

In 2012, a system was deployed to remove, transport, and interim store chemically reactive and highly radioactive sludge material from the Hanford Site's 105-K West Fuel Storage Basin that will be managed as spent/used nuclear fuel. The Knockout Pot (KOP) sludge in the 105-K West Basin was a legacy issue resulting from the spent nuclear fuel (SNF) washing process applied to 2200 metric tons of highly degraded fuel elements following long-term underwater storage. The washing process removed uranium metal and other non-uranium constituents that could pass through a screen with 0.25-inch openings; larger pieces are, by definition, SNF or fuel scrap. When originally retrieved, KOP sludge contained pieces of degraded uranium fuel ranging from 600 microns (μm) to 6350 μm mixed with inert material such as aluminum hydroxide, aluminum wire, and graphite in the same size range. In 2011, a system was developed, tested, successfully deployed and operated to pre-treat KOP sludge as part of 105-K West Basin cleanup. The pretreatment process successfully removed the vast majority of inert material from the KOP sludge stream and reduced the remaining volume of material by approximately 65 percent, down to approximately 50 liters of material requiring management as used fuel. The removal of inert material resulted in significant waste minimization and project cost savings because of the reduced number of transportation/storage containers and improvement in worker safety. The improvement in worker safety is a result of shorter operating times and reduced number of remote handled shipments to the site fuel storage facility. Additionally in 2011, technology development, final design, and cold testing was completed on the system to be used in processing and packaging the remaining KOP material for removal from the basin in much the same manner spent fuel was removed. This system was deployed and successfully operated from June through September 2012, to remove and package the last of the SNF fragments from the 105-K West Basin, ending the long and complex history of the KOP sludge materials. The planning and execution of this project demonstrated how the graded application of DOE O 413.3B, Program and Project Management for the Acquisition of Capital Assets[1], DOE-STD-1189-2008, Integration of Safety into the Design Process[2], and DOE G 413.3-4, U.S. Department of Energy Technology Readiness Assessment Guide[3], can positively affect the outcome of project implementation in the DOE Complex. Provided herein are relevant information, ideas, and tools for use by other projects facing similar issues in managing high risk waste streams in a complex regulatory environment. Positive aspects are also provided of appropriate time spent in detailed planning, design, and testing in non-hazardous environments to reduce project risks in both cost and safety performance, as well as improving confidence in meeting project goals through predictable and reliable performance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The North Dakota integrated carbon storage complex feasibility study

Here, the Energy & Environmental Research Center is investigating the feasibility of safely, permanently, and economically storing 50 million tonnes of CO 2 in central North Dakota, United States, over a 25-year operational period, should a business case for CO 2 storage emerge. The study is part of the U.S. Department of Energy (DOE) National Energy Technology Laboratory CarbonSAFE initiative and addresses the technical and nontechnical challenges of commercially deploying a CO 2 storage project. Evaluation of cores from two stratigraphic test wells demonstrate that the Broom Creek Formation (sandstone) is an excellent candidate for the geologic storage of CO 2 and the overlying Opeche Formation a competent cap rock.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

CO 2 geological storage: Critical insights on plume dynamics and storage efficiency during long-term injection and post-injection periods

In the quest for net-zero greenhouse gas emission, CO 2 capture and storage technologies play a prominent role. Estimates suggest a potential of sequestering up to several thousand metric gigatons of CO 2 . However, some of the main challenges in its development are an assessment of reservoir-specific storage capacities due to variabilities and heterogeneities in the underlying properties (structure, formations, facies, petrophysics, reservoir architecture, and others) and understanding the migration of CO 2 in the subsurface. How much CO 2 can be stored in a reservoir, and how quickly can it be injected? What will be the dominant storing (trapping) mechanisms? These questions, among others, remain as challenges to the commercial deployment of this technology. This article critically investigates CO 2 plume characteristics and determines the evolving contributions of different trapping mechanisms during a 100-year injection period. Here, simulation results on the CO 2 plume dynamics indicate that lateral propagation is much larger than vertical propagation. The ratio of average lateral to vertical dispersion ranged between 6.3 and 18.8 for the cases investigated. On average, for all the scenarios investigated, the free phase (mobile supercritical CO 2 ) is the dominant trapping mechanism (in terms of the amount of CO 2 stored) during the injection period, accounting up to 45% of the CO 2 injected. Both residual (30%) and solubility (25%) trapping storage ratios decline with time during injection, and no significant mineral trapping appeared during the 100-year injection period. However, the behavior of CaCO 3 suggests a predominant dissolution of CaCO 3 , especially in the vicinity of the injection well.

03 NATURAL GAS↗

Challenges and future perspectives on sodium and potassium ion batteries for grid-scale energy storage

The energy crisis and environmental pollution require the advancement of large-scale energy storage techniques. Among the various commercialized technologies, batteries have attracted enormous attention due to their relatively high energy density and long cycle life. Nevertheless, the limited supply and uneven distribution of lithium minerals, as well as their high cost, has greatly hindered the application of lithium-ion batteries in large-scale energy storage. Therefore, building next-generation alternative rechargeable batteries that feature low cost, long service life, and high safety is of the utmost importance. Over the past several years, we have witnessed many successful research outcomes for sodium and potassium ion batteries (SIBs and PIBs) in regard to electrode and electrolyte materials. In this Perspective, we summarize the current developments on SIBs/PIBs and their challenges when facing practical applications, including their cost, energy density, ion diffusivity in solids/electrolytes/interphases, cycle life, and safety concerns. Furthermore, we provide an overview of strategies to overcome the remaining challenges for achieving better electrochemical performance. Finally, we outline several possible directions for the future development of these two battery chemistries, with the hope of aiding the transition from the laboratory to next-generation practical applications for SIBs/PIBs batteries in grid-scale energy storage.

Energy Storage↗