At least 271 records · Page 15

Contingency Contractor Optimization Phase 3 Extension Quick Start Guide: Contingency Contractor Optimization Tool - Engineering Prototype (Release 2.3)

This Quick Start Guide is an abbreviated version of the Contingency Contractor Optimization Phase 3, User Manual for the Contingency Contractor Optimization Tool engineering prototype. It focuses on providing quick access instructions to the core activities of the two main user roles: Planning Manager and Analyst. Based on an electronic storyboard prototype developed in Phase 2, the Contingency Contractor Optimization Tool engineering prototype was refined in Phase 3 of the OSD ATL Contingency Contractor Optimization to support strategic planning for contingency contractors. The tool uses a model to optimize the total workforce mix by minimizing the combined total costs for the selected mission scenarios. The model will optimize the match of personnel types (military, DoD civilian, and contractors) and capabilities to meet the mission requirements as effectively as possible, based on risk, cost, and other requirements.

42 ENGINEERING↗

Contingency Contractor Optimization Phase 3 Quick Start Guide Contingency Contractor Optimization Tool Prototype - Release 2.2

This Quick Start Guide is an abbreviated version of the Contingency Contractor Optimization Phase 3, User Manual for the Contingency Contractor Optimization Tool engineering prototype. It focuses on providing quick access instructions to the core activities of the two main user roles: Planning Manager and Analyst. Based on an electronic storyboard prototype developed in Phase 2, the Contingency Contractor Optimization Tool engineering prototype was refined in Phase 3 of the OSD ATL Contingency Contractor Optimization to support strategic planning for contingency contractors. The tool uses a model to optimize the total workforce mix by minimizing the combined total costs for the selected mission scenarios. The model will optimize the match of personnel types (military, DoD civilian, and contractors) and capabilities to meet the mission requirements as effectively as possible, based on risk, cost, and other requirements.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Idaho Falls Power Black Start Field Demonstration (Preliminary Outcomes Paper)

This April 2021 field demonstration builds upon a 2017 field demonstration in which it was determined IFP’s HPPs, on their own, can support islanded black start and operation up to 2.5 MW loading. Modeling and hardware-in-the-loop testing was used in the intervening period to design an energy storage solution, specifically using ultracapacitors, to reduce likelihood of generators tripping during the field demonstration. Overall, the 2021 field demonstration tested three different options for meeting IFP’s requirements: innovating the hydropower controls, synchronizing multiple HPPs on the system, and integrating an ultracapacitor energy storage system. This report documents the testing performed. Follow-on analysis will provide additional insights, for example, including a complete table of comparative results between the tests and scenarios. The analysis will also propose a refined design for an energy storage system to meet IFP’s grid islanded needs.

13 HYDRO ENERGY↗

Campaign Guidelines: Security Starts With You [Slides]

The Security Starts With You Campaign Guidelines have been prepared by the CEA-CAS Visual Design team for use primarily by DSOs, FODs, and/or any LANL employee who wishes to extend the messaging to new and existing buildings. By adhering to this guidance, you will be a responsible steward of the “One Lab, one voice” mentality and successfully implement the Lab’s brand and security messaging on all of your communications.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Optimal Electric Grid Black Start Restoration Subject to Intentional Threats

Efficient restoration of the electric grid from significant disruptions – both natural and manmade – that lead to the grid entering a failed state is essential to maintaining resilience under a wide range of threats. Restoration follows a set of black start plans, allowing operators to select among these plans to meet the constraints imposed on the system by the disruption. Restoration objectives aim to restore power to a maximum number of customers in the shortest time. Current state-of-the-art for restoration modeling breaks the problem into multiple parts, assuming a known network state and full observability and control by grid operators. These assumptions are not guaranteed under some threats. This paper focuses on a novel integration of modeling and analysis capabilities to aid operators during restoration activities. A power flow-informed restoration framework, comprised of a restoration mixed-integer program informed by power flow models to identify restoration alternatives, interacts with a dynamic representation of the grid through a cognitive model of operator decision-making, to identify and prove an optimal restoration path. Application of this integrated approach is illustrated on exemplar systems. Validation of the restoration is performed for one of these exemplars using commercial solvers, and comparison is made between the steps and time involved in the commercial solver, and that required by the restoration optimization in and of itself, and by the operator model in acting on the restoration optimization output. Publications and proposals developed under this work, along with a path forward for additional expansion of the work, and summary of what was achieved, are also documented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Start-up Operation Experience with a Liquid Fluoride Salt Forced Convection Loop

A liquid fluoride salt forced convection test loop was constructed at Oak Ridge National Laboratory. Its unique features include a pebble bed test section, high-temperature instrumentation, a noncontact rotating gas seal for the pump, a silicon carbide flow tube, and a unique inductive heating technique. Initial startup and shake-down testing has been completed. This paper describes how several of the systems performed, highlights those that worked well, and discusses issues that arose during the start-up process. This discussion should be of interest to those who intend to develop molten salt technologies and who are interested in some of the specific techniques used in this experiment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Start-to-end simulation for LAMP front-end scoping studies

We present a design of a new front end in support of the LANSCE Modernization Project (LAMP). This is an updated front-end design that can largely meet LAMP threshold needs. The first half of this report details each section of the front end, including a summary of the physics design and function. The second half simulates several beam formats from the initial source all the way through the final DTL section (i.e. start-to-end simulations). Details and assumptions are described. The following table summarizes the key results for the different beam formats from this study.

43 PARTICLE ACCELERATORS↗

ARAM Quick Start Guide

Quick start guide for Airport Risk Assessment model. The ARAM dashboard gives you a quick snapshot of the current day’s risk and countermeasure deployment profile.

97 MATHEMATICS AND COMPUTING↗

Storage Sizing and Placement Simulation: Quick-Start Case Study User’s Guide

The Storage Sizing and Placement Simulation (SSIM) application allows a user to define the possible sizes and locations of energy storage elements on an existing grid model defined in OpenDSS. Given these possibilities, the software will automatically search through them and attempt to determine which configurations result in the best overall grid performance. This quick-start guide will go through, in detail, the creation of an SSIM model based on a modified version of the IEEE 34 bus test feeder system. There are two primary parts of this document. The first is a complete list of instructions with little-to-no explanation of the meanings of the actions requested. The second is a detailed description of each input and action stating the intent and effect of each. There are links between the two sections.

25 ENERGY STORAGE↗

OpenCSP Step-by-Step: Getting Started Guide for Windows (V.1.0)

This document provides a step-by-step tutorial on how to set up OpenCSP for both users and developers. It is meant to support novice users and does not require software engineering experience. It is a detailed extension of the OpenCSP getting started on-line documentation, found here: https://opencsp.readthedocs.io/en/main/contributing.html#getting-started. For an overview of OpenCSP overall, see the OpenCSP website: https://opencsp.sandia.gov. For details on OpenCSP components and algorithm, see the references.

97 MATHEMATICS AND COMPUTING↗

Measuring Neutron Polarisation in Deuteron Photo-disintegration with the CLAS Start Counter [Thesis]

Deuteron photo-disintegration (γd → γp) is a reaction that represents the simplest case in which nuclear and hadron physics models can be tested. Despite this, associated polarization analyses are limited in terms of angular coverage and energy ranges, especially in observables related to the recoil neutron. This is largely due to a lack in dedicated polarimetry equipment, and represents a roadblock in global progress to understand high-energy phenomena such as hexaquarks, and quark-gluon degrees of freedom. To address this problem, this PhD thesis pioneers a new methodology for the parasitic measurement of nucleon polarization using kinematic reconstruction of (spin-dependent) nucleon-nucleus scattering of reaction products, prior to their detection in large acceptance particle detector apparatus. Following this novel approach, which requires no dedicated polarimeter, a determination of the double polarization observable, $C^n_{x'}$, from deuteron photo-disintegration is presented, using Jefferson Lab’s CLAS detector. The analysis utilizes the (n,p) charge exchange reaction in CLAS’s "start counter" (plastic scintillator) to determine the final state neutron polarizations. The results present the first ever data for this observable above 0.7 GeV (photon beam energy) and significantly extend the angular range of the world data set. This new data is largely statistically consistent with the previous measurement of $C^n_{x'}$ by Bashkanov et al . in the overlapping energy range of 0.4-0.7 GeV. It is planned for the statistical accuracy of the presented result to be increased by the inclusion of additional data. The analysis herein serves as a key proof of concept for future applications, including a recommended similar analysis to be implemented with data from the more modern CLAS12 detector. This paves the way for a plethora of additional analyses using existing data sets that would provide crucial new constraints for hadron and nuclear physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

FORMATION OF THE PENUMBRA AND START OF THE EVERSHED FLOW

We studied the variations of line of sight photospheric plasma flows during the formation phase of the penumbra around a pore in active region NOAA 11490. We used a high spatial, spectral, and temporal resolution data set acquired by the Interferometric BIdimensional Spectrometer operating at the NSO/Dunn Solar Telescope as well as data taken by the Helioseismic and Magnetic Imager on board the Solar Dynamics Observatory satellite ( SDO /HMI). Before the penumbra formed we observed a redshift of the spectral line in the inner part of the annular zone surrounding the pore as well as a blueshift of material associated with opposite magnetic polarity farther away from the pore. We found that the onset of the classical Evershed flow occurs on a very short timescale (1 to 3 hr) while the penumbra is forming. During the same time interval we found changes in the magnetic field inclination in the penumbra, with the vertical field actually changing sign near the penumbral edge, while the total magnetic field showed a significant increase, about 400 G. To explain these and other observations related to the formation of the penumbra and the onset of the Evershed flow we propose a scenario in which the penumbra is formed by magnetic flux dragged down from the canopy surrounding the initial pore. The Evershed flow starts when the sinking magnetic field dips below the solar surface and magnetoconvection sets in.

79 ASTRONOMY AND ASTROPHYSICS↗

When Do Different Scenarios of Future Electricity Demand Start to Meaningfully Diverge?

Climate and population change are known to influence electricity demand, but what is the impact of uncertainty in climate and population projections on electricity demand in the United States (U.S.) over the next 30 years? This question has important implications for investment decisions in the energy sector, which are typically made using a 15- to 30-year time horizon. Simply put, if future climate and population scenarios do not lead to meteorological conditions and subsequent energy demands that are distinctly different within the first 30 years then, for the purposes of investment decisions, it may not matter which potential pathway we are most likely on. The Integrated, Multisector, Multiscale Modeling (IM3) project has generated a wide, yet plausible range of 21st century high-resolution climate and population scenarios for the U.S. The IM3 projections span two climate scenarios (Representative Concentration Pathways 4.5 and 8.5) and two population scenarios (Shared Socioeconomic Pathways 3 and 5). For each of the climate scenarios, we reflect a range of climate model uncertainty by using boundary conditions from a set of climate models that are hotter and colder than the multi-model mean. In total there are eight (2 x 2 x 2) IM3 scenarios. This work explores a basic question: When do future climate and energy outcomes start to meaningfully diverge across the eight scenarios? The analysis is done on both the raw meteorology time-series from each scenario as well as a time-series of projected total electricity demand generated using IM3's Total ELectricity Loads (TELL) model. We also explore the spatial heterogeneity of the divergence signal to identify regions of the country that may be more or less path dependent.

Climate Change↗

PNNL Delivers Expertise, Technology to Biofuels Start-up, InEnTec

Initially through its Entrepreneurial Leave of Absence Program, PNNL gives biofuels innovators a start in opening up a new business based on technology developed for incinerating waste on the Hanford Site. Today, the companies Plasma Enhanced Melters are in operation around the world converting organic waste into valuable, clean fuels.