Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SOLENOIDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Impact of Solenoid Induced Residual Magnetic Fields on The Prototype SSR1 CM Performance

A prototype cryomodule containing eight Single Spoke Resonators type-1 (SSR1) operating at 325 MHz and four superconducting focusing lenses was successfully assembled, cold tested, and accelerated beam in the framework of the PIP-II project at Fermilab. The impact of induced residual magnetic fields from the solenoids on performance of cavities is presented in this contribution. In addition, design optimizations for the production cryomodules as a result of this impact are highlighted.

43 PARTICLE ACCELERATORS↗

Sensitivity of Beam Parameters to a Station C Solenoid Scan on Axis II

Magnet scans are a standard technique for determining beam parameters in accelerators. Beam parameters are inferred from spot size measurements using a model of the beam optics. The sensitivity of the measured beam spot size to the beam parameters is investigated for typical DARHT Axis II beam energies and currents. In a typical S4 solenoid scan, the downstream transport is tuned to achieve a round beam at Station C with an envelope radius of about 1.5 cm with a very small divergence with S4 off. The typical beam energy and current are 16.0 MeV and 1.625 kA. Figures 1-3 show the sensitivity of the bean size at Station C to the emittance, initial radius and initial angle respectively. To better understand the relative sensitivity of the beam size to the emittance, initial radius and initial angle, linear regressions were performed for each parameter as a function of the S4 setting. The results are shown in Figure 4. The measured slope was scaled to have a maximum value of 1 in order to present the relative sensitivities in a single plot. Figure 4 clearly shows the beam size at the minimum of the S4 scan is most sensitive to emittance and relatively insensitive to initial radius and angle as expected. The beam emittance is also very sensitive to the beam size of the converging beam and becomes insensitive to the beam size of the diverging beam. Measurements of the beam size of the diverging beam provide the greatest sensitivity to the initial beam radius and to a lesser extent the initial beam angle. The converging beam size is initially very sensitive to the emittance and initial angle at low S4 currents. As the S4 current is increased the sensitivity to the emittance remains strong while the sensitivity to the initial angle diminishes.

43 PARTICLE ACCELERATORS↗

ARIA Cell Solenoid Design Considerations

Detailed schematics of the structure of the preliminary ARIA solenoid cell design are given, including overhead and cross section views and dimensions.

43 PARTICLE ACCELERATORS↗

New Physics Search in Dijet Mass Spectrum with Compact Muon Solenoid

Many extensions of the SM predict the existence of new massive objects that couple to quarks and gluons and result in resonances in the dijet mass spectrum. In this thesis we present a search for narrow resonances in the dijet mass spectrum using data corresponding to an integrated luminosity of 1 fb$^{-1}$ collected by the CMS experiment at the LHC, at a proton-proton collision energy of $\sqrt{s}=7$ $TeV$. %This dijet analysis is searching for new particles in the dijet mass spectrum decaying to dijets. These new particles are predicted by new physics beyond Standard Model. This thesis presents a dijet analysis performed at the Compact Muon Solenoid (CMS) in pp collisions at $\sqrt{s}=7$ $TeV$ for an integrated luminosities of 1.0 fb$^{-1}$. The dijet mass distribution of two leading jets is measured and compared to QCD predictions, simulated by PYTHIA with the CMS detector simulation. We select events which have two leading jets with $\mid \Delta\eta \mid < 1.3$ and $\mid \eta \mid < 2.5$. We fit the dijet mass spectrum with QCD parameters. Since no evidence of new physics was found, we set upper limits at 95\% CL on the resonance cross section and compare to the theoretical prediction for several models of new particles: string resonances, axigluons, colorons, excited quarks, $E_{6}$ diquarks, Randall-Sundrum gravitons, W' and Z'. We exclude at 95\% CL string resonances in the mass range $1.0 < M(S) < 4.00$ TeV, excited quarks in the mass range $1.0<M(q*)<2.49$ TeV, axigluons and colorons in the mass range $1.0<M(A)<2.47$ TeV, $E_6$ diquarks in the mass range $1.0<M(D)<3.52$ TeV, and W' bosons in the mass range $1.0<M(W')<1.51$ TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DARHT Axis II Cell Solenoid Magnet Shunt Resistance

DARHT Axis-II cell solenoid magnets have exhibited significant degradation since initial manufacture. A recent redesign of these magnets has provided an opportunity to revisit the dielectric performance to ensure high quality magnets are obtained. Magnet test specifications are shown to be consistent with those recommended in the literature and in use by practicing magnet engineers. A dielectric analysis of the coil reveals that the epoxy layer thickness and integrity are critical to meeting the required performance but are not adequately controlled in the present specification. Remedies to the coil fabrication process are provided.

42 ENGINEERING↗

Scorpius injector emittance measurements with solenoid scans

A classic scan solenoid can establish that the injector meets emittance requirements. Incorporating an aperture plate can validate predictions of much lower emittance. Measurements of beam parameters on the injector and ITS can inform predictions for the full LIA. Injector beam data is needed to tune the full LIA for initial turn-on and operation. Emittance measurements on the Scorpius injector are difficult because the beam is space-charge dominated. Emittance measurements on Scorpius injector and ITS will need large beam size to prevent overheating.

43 PARTICLE ACCELERATORS↗

Transport of a Low-Energy Beam from the Scorpius Accelerator to the Final-Focus Solenoid

It may be required to use Scorpius for low-energy radiography of hydrodynamic experiments, perhaps as low as the 2-MeV injected beam kinetic energy. As presently designed, the downstream transport (DST) system will not work for energies less than about 4.5 MeV due to space-charge defocusing. For energies less than that the beam envelope expands to the wall before the first magnet can catch and focus it. More solenoids would have to be added to the DST lattice in order to transport a beam with KE < 4.5 MeV to the final focus.

43 PARTICLE ACCELERATORS↗

Impact of solenoid induced residual magnetic fields on the prototype SSR1 CM performance

A prototype cryomodule containing eight Single Spoke Resonators type-1 (SSR1) operating at 325 MHz and four superconducting focusing lenses was successfully assembled, cold tested, and accelerated beam in the framework of the PIP-II project at Fermilab. The impact of induced residual magnetic fields from the solenoids on performance of cavities is presented in this contribution. In addition, design optimizations for the production cryomodules as a result of this impact are highlighted.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pulsed High Temperature Superconducting Central Solenoid for Revolutionizing Tokamaks

Commonwealth Fusion Systems (CFS) has developed the technical foundation for a fast-ramping High Temperature Superconducting (HTS) Central Solenoid Model Coil (CSMC), addressing key challenges in fusion energy advancement. This breakthrough enables the design of all-HTS pulsed tokamak power plants that promise to reduce projected electricity costs by 50% and overnight construction costs by 25% compared to steady-state tokamaks, while eliminating the need for complex external current drives.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Role of Parallel Solenoidal Electric Field on Energy Conversion in 2.5D Decaying Turbulence with a Guide Magnetic Field

We perform 2.5D particle-in-cell simulations of decaying turbulence in the presence of a guide (out-of-plane) background magnetic field. The fluctuating magnetic field initially consists of Fourier modes at low wavenumbers (long wavelengths). With time, the electromagnetic energy is converted to plasma kinetic energy (bulk flow+thermal energy) at the rate per unit volume of J· E for current density J and electric field E. Such decaying turbulence is well known to evolve toward a state with strongly intermittent plasma current. Here we decompose the electric field into components that are irrotational, E ir , and solenoidal (divergence-free), E so . E ir is associated with charge separation, and J · E ir is a rate of energy transfer between ions and electrons with little net change in plasma kinetic energy. Therefore, the net rate of conversion of electromagnetic energy to plasma kinetic energy is strongly dominated by J · E so , and for a strong guide magnetic field, this mainly involves the component E so,∥ parallel to the total magnetic field B. We examine various indicators of the spatial distribution of the energy transfer rate J ∥ · E so,∥ , which relates to magnetic reconnection, the best of which are (1) the ratio of the out-of-plane electric field to the in-plane magnetic field, (2) the out-of-plane component of the nonideal electric field, and (3) the magnitude of the estimate of current helicity.

79 ASTRONOMY AND ASTROPHYSICS↗

Search for New Physics with the Compact Muon Solenoid Experiment and QIS-enabled Technology

Understanding the fundamental nature of dark matter (DM)---its cosmological origin, constituents, and interactions---is one of the most important questions in fundamental science today. In this thesis, I present two novel and highly complementary approaches to cover the gaps in sensitivity of current DM searches. The searches are enabled by a first-of-its-kind reconstruction technique to search for hidden-sector particles using the Compact Muon Solenoid (CMS) and by new advances in quantum sensing technology to search for axions and hidden-sector DM. In the first part of this thesis, I present a search for long-lived hidden sector particles, predicted by many extensions of the SM, using a novel technique to reconstruct decays of long-lived particles (LLPs) in the CMS muon detector. The innovative LLP reconstruction technique is sensitive to a broad range of LLP decays and to LLP masses below GeV. The search yields competitive sensitivity for proper lifetime 0.1--1000 m with the full Run 2 dataset recorded at the LHC between 2016--2018 at $\sqrt{s} = 13~$TeV. To extend the physics reach of this novel muon detector shower (MDS) signature, I present the model-independence of MDS and the reinterpretation of the search to a large number of LLP models, demonstrating its complementarity with proposed and existing dedicated LLP experiments. Finally, I present a new dedicated MDS trigger that improves the trigger efficiency by at least an order of magnitude and was deployed in 2022, at the start of Run 3 of the LHC operations. In the second part of the thesis, I present for the first time, the use of a novel quantum sensor, the low-noise and single-photon sensitive superconducting nanowire single photon detectors (SNSPDs), to directly detect dark matter. The low detection threshold and ultra-low dark count rate of SNSPDs can close the gap in DM discovery reach due to the current limitations in detector sensitivity. I will present my work on the development and characterization of SNSPDs for two entirely new experiments to directly detect axions via absorption and hidden-sector DM via electron scattering. The search for axions employs a novel broadband reflector technique with the Broadband Reflector Experiment for Axion Detection (BREAD). A unique parabolic mirror is then used to focus axion-converted photons to the SNSPDs, extending the reach to axion masses of 0.04--1 eV. On the other hand, by coupling the SNSPDs with gallium arsenide, a bright cryogenic scintillator well matched to SNSPD detection, a prototype sensing system can be built as a basis of new direct DM detection experiments capable of extending the discovery to DM masses as low as 1 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Force controlled solenoid drives microweld tester

Solenoid-driven device tests the integrity of a microweld joint between an electronic component lead wire and a wire ribbon by applying tension stress to the joint. Variable measured force is provided when either destructive or nondestructive testing is performed.

Source record↗