Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

A cleanroom in a glovebox

The exploration of new materials, novel quantum phases, and devices requires ways to prepare cleaner samples with smaller feature sizes. Initially, this meant the use of a cleanroom that limits the amount and size of dust particles. However, many materials are highly sensitive to oxygen and water in the air. Furthermore, the ever-increasing demand for a quantum workforce, trained and able to use the equipment for creating and characterizing materials, calls for a dramatic reduction in the cost to create and operate such facilities. To this end, we present our cleanroom-in-a-glovebox, a system that allows for the fabrication and characterization of devices in an inert argon atmosphere. Additionally, we demonstrate the ability to perform a wide range of characterization as well as fabrication steps, without the need for a dedicated room, all in an argon environment. Finally, we discuss the custom-built antechamber attached to the back of the glovebox. This antechamber allows the glovebox to interface with ultra-high vacuum equipment such as molecular-beam epitaxy and scanning tunneling microscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improving public communication through environmental data transparency at Los Alamos National Laboratory - 15306

The Los Alamos National Laboratory (LANL) environmental data span a wide range of media, including air, soil, sediment, water, foodstuff, and biota as well as over 1000 analytes and time periods extending over 4 decades, resulting in over 14 million records to manage and analyze. At a time of budget cuts and rapid social and technological change, the public, regulatory and compliance agencies, and stakeholders demand accelerated data delivery and efficiency, information sharing, and transparency in the dissemination and handling of samples collected in and around LANL. Meeting these requirements, while constraining the associated costs can be challenging; however, LANL has achieved this by adopting a cloud-based database called the Environmental Information Management (EIM) system and its public database counterpart, IntellusNM (Intellus) (www.intellusnm.com). To be consistent with federal initiatives to move government computing into cloud-based services, LANL chose to partner with an existing cloud-based vendor, Locus Technologies, to implement a software-as-a-service model. As an additional cost-saving measure, local regulatory and compliance agencies collaborated with LANL to incorporate their data into EIM and Intellus database. By adopting a single platform cloud-based solution to replace 12 different pre-existing environmental data systems, LANL has streamlined environmental data processes, resulting in over $15 million cost savings through 2015. EIM, LANL's internal cloud database, provides a cradle-to-grave process for data handling. EIM supports LANL's entire data process from detailed sample planning, mobile data collection using iOS mobile devices, to automated bottle labeling, generation of chain of custody, analytical lab electronic data deliverable upload, auto data validation, sample tracking, and custom regulatory and compliance reports. EIM has functionality to assess data in various ways such as the ability to design new formatted reports, a free-form structured query language tool of the entire database, exceedance reports, calculation engine, charting, trends, and statistics. EIM also has interactive geographic information system layers and analyte concentration color contour mapping capabilities. Additionally, and of greater importance to LANL, EIM supports the ability for third-party landowners to review data before release to the public, thus ensuring transparency and confidence in LANL's stewardship of human health and the environment. Intellus, the database counterpart of EIM, is the publicly available view of the entire LANL database and requires no data feeds or transformations. Intellus allows user-friendly access to LANL's environmental data as it is collected, providing the public, scientists, remediation teams, regulators, and stakeholders within hours of receipt. Full transparency in giving the public access to environmental data information provides LANL's overall solution to environmental data management for the public. By making the data easy to obtain, search, and query for interested stakeholders, the system enables confidence in LANL's stewardship of the environment. Working together identifies key topics of improvements, develop strategies and help support innovation and substantial advances within LANL's environmental data management system. (authors)

54 ENVIRONMENTAL SCIENCES↗

In-situ monitoring of flow-permeable surface area of high explosive powder using small sample masses

To ensure good performance of high explosive devices over long periods of time, initiating powders need to maintain their specific surface area within allowed margins during the entire duration of deployment. A common diagnostic used in this context is the Fisher sub-sieve surface area (FSSA). Furthermore, commercial permeametry instruments measuring the FSSA requires the utilization of a sample mass equal to the crystal density of the sample material, an amount that is often one or two orders of magnitude larger than the typical masses found in standard detonator applications. Here we develop a customization of the standard device that can utilize just tens of milligram samples, and with simple calibration yield FSSA values at ac curacy levels comparable to the standard apparatus. This necessitated a newly designed sample holder, made from a material of low coefficient of thermal expansion, which is conveniently transferred between an aging chamber and a re-designed permeametry tube. This improves the fidelity of accelerated aging studies by allowing measurement on the same physical sample at various time - instants during the aging process, and by obviating the need for a potentially FSSA-altering powder re-compaction step. We used the customized apparatus to monitor the FSSA evolution of a number of undoped and homolog-doped PETN powder samples that were subjected to artificial aging for several months at elevated temperatures. These results, in conjunction with an Arrhenius-based aging model were used to assess powder-coarsening - rates under long-term storage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-Field Alpha Spectrometry to Assess Uranium Enrichment In Uranium Hexafluoride

A new In-Field Alpha Spectrometry (IFAS) system is being developed to allow quick turnaround measurements of uranium enrichment in uranium hexafluoride (UF6) samples. Samples are collected using specially-designed Single-Use Destructive Assay (SUDA) wafers which have an absorptive film of zeolite deposited onto a quartz or metal substrate. The SUDA samples, along with a special holder, are designed to be attached directly to a sampling tap at a gas centrifuge enrichment plant or a uranium conversion facility, allowing gaseous UF6 to come into direct contact with the zeolite. The zeolite absorbs this material and converts it into stable, safe UO2F2 within a few minutes. Once the sample has been collected it is transferred to the IFAS system where a solid-state, silicon alpha spectrometer is used to quantitatively measure the alpha emissions from 234U, 235U, and 238U in the sample. The IFAS system is a small, light-weight device that can be quickly turned on and put into use. The SUDA samples and IFAS hardware are designed so that thin-film spectra are produced, allowing a complete measurement with a final 235U:Utotal determination having a precision <±2% to be made in less than eight hours. This short time frame will allow an inspector to get results on-site within one working shift; further innovations may reduce this to even shorter times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method to quantify the 37 Ar emanation fraction in powders and rocks

In order to make predictions of the potential 37 Ar signal from an underground nuclear explosion, a value for the 37 Ar emanation fraction is needed. Here, a system was developed to quantify the emanation fraction from samples ranging in size from powder to small rocks. Assorted rock samples were irradiated with Watt fission spectrum neutrons to produce radioactive argon gas via activation of calcium. The argon produced was extracted on a custom apparatus and cryogenically trapped. The extracted gas was then processed to separate the argon and load it into a proportional counter for counting. The emanation fraction of argon gas from the rock samples was then calculated by comparing the measured and predicted activities.

37Ar↗

Portable Sample Preparation For Chemical and Biological Analysis

Preparing samples for chemical or biological analysis is often time consuming and a critical step function to assure an accurate analysis. This invention provides an automated, hands-free, highly accurate device to prepare industrial, chemical, or biological samples for instrumental analysis methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new ultrasonic transducer sample cell for in situ small-angle scattering experiments

Ultrasound irradiation is a commonly used technique for nondestructive diagnostics or targeted destruction. We report on a new versatile sonication device that fits in a variety of standard sample environments for neutron and X-ray scattering instruments. A piezoelectric transducer permits measuring of the time-dependent response of the sample in situ during or after sonication. We use small-angle neutron scattering (SANS) to demonstrate the effect of a time-dependent perturbation on the structure factor of micelles formed from sodium dodecyl sulfate surfactant molecules. We observe a substantial change in the micellar structure during and after exposure to ultrasonic irradiation. We also observe a time-dependent relaxation to the equilibrium values of the unperturbed system. The strength of the perturbation of the structure factor depends systematically on the duration of sonication. The relaxation behavior can be well reproduced after multiple times of sonication. Accumulation of the recorded intensities of the different sonication cycles improves the signal-to-noise ratio and permits reaching very short relaxation times. In addition, we present SANS data for the micellar form factor on alkyl-poly (ethylene oxide) surfactant molecules irradiated by ultrasound. Due to the flexibility of our new in situ sonication device, different experiments can be performed, e.g., to explore molecular potentials in more detail by introducing a systematic time-dependent perturbation.

47 OTHER INSTRUMENTATION↗

Sampling frequency thresholds for the quantum advantage of the quantum approximate optimization algorithm

We compare the performance of the Quantum Approximate Optimization Algorithm (QAOA) with state-of-the-art classical solvers Gurobi and MQLib to solve the MaxCut problem on 3-regular graphs. We identify the minimum noiseless sampling frequency and depth p required for a quantum device to outperform classical algorithms. There is potential for quantum advantage on hundreds of qubits and moderate depth with a sampling frequency of 10 kHz. We observe, however, that classical heuristic solvers are capable of producing high-quality approximate solutions in linear time complexity. In order to match this quality for large graph sizes N, a quantum device must support depth p > 11. Additionally, multi-shot QAOA is not efficient on large graphs, indicating that QAOA p ≤ 11 does not scale with N. These results limit achieving quantum advantage for QAOA MaxCut on 3-regular graphs. Other problems, such as different graphs, weighted MaxCut, and 3-SAT, may be better suited for achieving quantum advantage on near-term quantum devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low cost and facile fabrication of broadband laser power meter based on reduced graphene oxide film

Highlights: • The reduced graphene oxide film is used to fabricate the low cost laser powermeter. • The photoresponse of the device is explored in the visible to near-infrared range. • The photoresponse of the device is linearly related to the irradiated laser power. • The photoelectric current of the device does not depend on the laser spot size. - Abstract: Here, we have demonstrated a new type of broadband reduced graphene oxide-based laser power meter in simple and low cost method. The broadband photosensitivity of the device is confirmed by photocurrent measurements at different incident laser wavelengths of 405, 532, 635 and 808 nm. It is shown that its photocurrent increases linearly with increasing the power of the laser beam. Also, it is observed that the photocurrent behavior of the device does not depend upon the size of the laser spot. It should be noted that the reduced graphene oxide power meter is the thermal detection device. Therefore, the response of the sample in the vacuum is greatly enhanced in compared to the environmental air. Cooling system can also decrease the time required for the establishment of thermal equilibrium and thus reduce the response time of the power meter. These results open up exciting opportunities for developing broadband photodetectors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Limiting Case of Constant Counterion Electrochemical Potentials in the Membrane for Examining Ion Transfer at Ion-Exchange Membranes and Patches

We present that ion passage through ion-exchange membranes is vital in electrodialysis desalination, batteries and fuel cells, and water splitting. Simplified models of ion transport through such membranes frequently assume complete exclusion of coions (ions with the same sign of charge as the fixed charge in the membrane) from the membrane. However, a second assumption of constant counterion electrochemical potentials across the membrane leads to simple analytical expressions for ion fluxes and transmembrane potentials. Moreover, linear corrections to account for a small membrane electrical resistance yield analytical expressions with a wider applicability. For bi-ionic potential measurements and current-induced concentration polarization at low salt concentrations, these analytical solutions match the fluxes and potentials obtained numerically without the limiting assumptions. This gives confidence in both the limiting assumptions (under appropriate conditions) and the numerical solutions. At low ion concentrations, the analytical solutions may enable rapid characterization of membrane coatings or boundary layers in solution, and such boundary layers are important in many applications of ion-exchange membranes. In fact, the assumption of complete coion exclusion is sometimes more limiting than the constraint of constant electrochemical potentials of counterions across the membrane. Remarkably, this limiting case readily yields the ion accumulation and depletion regions above “ion-exchange patches” that reside beneath a solution with an applied electric field. Finally, such regions are important for sample pre-concentration in microfluidic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Isotope-resolved atomic beam laser spectroscopy of natural uranium

Here, we present our results on the development of a technique for conducting laser absorption spectroscopy of uranium in a collimated atomic beam using a compact and potentially fieldable device. A solid natural uranium metal sample is vaporized in a modest vacuum of several mTorr via resistive heating of a tantalum foil micro-crucible. A temperature of over 2000 °C is reached by applying only 200 W of electrical power to the crucible. At this temperature, the vapor pressure of uranium is large enough to generate a stable atomic beam. A diode laser is tuned around the 861.031 nm uranium transition, which allows the observation of absorption bands from both the 238 U and 235 U isotopes. The isotopic composition of uranium Standard Reference Material 960 is obtained from the absorption signal, in excellent agreement with the nominal value. In conclusion, our approach can be readily applied to the isotopic analysis of other actinides, and it is expected to lead to the development of compact, fieldable instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cadmium zinc telluride based infrared interferometry for X-ray detection

Cadmium Zinc Telluride (CZT) is a wide band gap semiconductor for room temperature radiation detection. The electro-optic Pockels effect of the material has been exploited in the past to study electric field non-uniformities and their consequence on conventional detector signals in CZT, by imaging the intensity distribution of infrared (IR) light transmitted through a device placed between crossed polarizers. Recently, quantitative monitoring of extremely high intensity neutron pulses through the change of transmitted IR intensity was demonstrated, offering the advantage to place sensitive electronics outside the measured radiation field. In this work, we demonstrate that X-ray intensity can be deduced directly from measuring the change in phase of 1550 nm laser light transmitted through a 7 × 7 × 2 mm{sup 3} CZT based Pockels cell in a simple Mach Zehnder interferometer. X-rays produced by a 50 kVp Mo X-ray tube incident on the CZT cathode surface placed at 7 mm distance cause a linearly increasing phase shift above 0.3 mA tube current, with 1.58 ± 0.02 rad per mA for an applied bias of 500 V across the 2 mm thick device. Pockels images confirm that the sample properties are in agreement with the literature, exhibiting electric field enhancement near the cathode under irradiation, which may cause the non-linearity at low X-ray tube anode current settings. The laser used to probe the X-ray intensity causes itself some space charge, whose spatial distribution does not seem to be exclusively determined by the incident laser position, i.e., charge carrier generation location, with respect to the electrodes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fluorine-ion-beam modification of magnetic properties of thin GaMnAs films

Magnetic and electrical transport properties of fluorine-ion-beam irradiated GaMnAs films were studied as a function of ion fluence and energy of impinging ions. The different nature of defects created by ions of low- and high-energies is explored in this work by means of transport and magnetization measurements. Our results show that the saturation magnetization of the irradiated samples is suppressed as the ion fluence is increased. Interestingly, however, the same effect is not observed in the case of critical temperature, which remains nearly the same for irradiated and non-irradiated samples measured by superconducting quantum interference device. Magnetotransport measurements appear to provide more reliable results regarding the critical temperature, since they are consistent with the ion-irradiation-induced disorder in the GaMnAs film, quantified here as the increase of the resistivity. We discuss this behavior based on the inhomogeneity of damages caused by the irradiation process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bragg polaritons in a ZnSe-based unfolded microcavity at elevated temperatures

In this contribution, we present strong coupling of ZnSe quantum well excitons to Bragg modes resulting in the formation of Bragg polariton eigenstates, characterized by a small effective mass in comparison to a conventional microcavity. We observe an anticrossing of the excitonic and the photonic component in our sample being a clear signature for the strong-coupling regime. The anticrossing is investigated by changing the detuning between the excitonic components and the Bragg mode. We find anticrossings between the first Bragg mode and the heavy- as well as light-hole exciton, respectively, resulting in three polariton branches. The observed Bragg-polariton branches are in good agreement with theoretical calculations. The strong indication for the existence of strong coupling is traceable up to a temperature of 200 K, with a Rabi-splitting energy of 24 meV and 13 meV for the Bragg mode with the heavy- and light-hole exciton, respectively. These findings demonstrate the advantages of this sample configuration for ZnSe-based devices for the strong coupling regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Identification of dislocation-related and point-defects in III-As layers for silicon photonics applications

Abstract The aim of this paper is to identify, analyze and compare the defects present in III-As, as a function of dislocation density, and as a function of the presence/absence of quantum dots (QDs). Such materials are of fundamental importance for the development of lasers and photodiodes for silicon photonics. The study is based on an extensive deep-level transient spectroscopy investigation, carried out on GaAs pin diodes grown on Si and on GaAs (that differ in the dislocation density), with and without embedded QDs. The original results described in this paper demonstrate that: (a) we were able to identify four different defects within the device grown on Si (three electron and one hole traps) and one defect (hole trap) in the device on GaAs, common to both samples; (b) all the majority carrier traps identified are located near midgap, i.e. are efficient non-radiative recombination centers; (c) such defects are absent (or non-detectable) in the sample grown on GaAs substrate, having a very low dislocation density; (d) the presence of QDs does not result in additional defects within the semiconductor material; (e) the analysis of the capture kinetics revealed that two of the identified traps are related to point defects, whereas the other two traps can be associated with point defects located near a dislocation; (f) a comparison with previous reports indicate that the detected traps are related to native III-As defects, or to oxygen-related complexes.

Physics↗

A 291-day Evaluation of the Performance of a Consumer-grade Temporal Radon Detector

Affordable, accurate, and robust temporal measurement devices are desirable for screening and assessment of radon levels in private homes and workplaces. This research expands upon prior research, using the RadonFTlab RadonEye device through a comparison of multiple samples of this instrument with a laboratory-grade instrument, the Saphymo AlphaGUARD, over a more extensive period than reported previously. Data were collected over 291 d in a poorly ventilated basement space in an occupied building. Environmental conditions varied naturally, changing both the radon source term and radon entry into the space approximating typically deployed conditions. The R-squared linear regression correlation coefficient and relative sensitivities of each RadonEye with the AlphaGUARD were computed. Altogether temporal and diurnal variations were also studied. The sensitivities of all RadonEyes and the AlphaGUARD agreed to within 22% throughout the entire deployment period.

47 OTHER INSTRUMENTATION↗