Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Readout electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

The MicroBooNE Technical Design Report

MicroBooNE will build, operate, and extract physics from the first large liquid argon time projection chamber (LArTPC) that will be exposed to a high-intensity neutrino beam. With its unparalleled capabilities in tracking, vertexing, calorimetry, and particle identification, all with full electronic readout, MicroBooNE represents a major advance in detector technology for neutrino physics in the energy regime of most importance for elucidating oscillation phenomena.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online and Offline Monitoring of the ICARUS Detector

In preparation for the launch of the ICARUS -T600 far detector in the Short Baseline Neutrino program, (SBN), it is important to monitor the performance of the detector and quality of the data in real-time. Particularly important to monitor are noise levels of the TPC readout electronics, and the purity of the liquid argon in the TPC, as these can affect the overall sensitivity of the detector to detecting and reconstructing neutrino interactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Mu2e Calorimeter Final Technical Design Report

Since the first version of the Mu2e TDR released at the beginning of 2015, the Mu2e Calorimeter system has undergone a long list of changes to arrive to its final design. These changes were primarily caused by two reasons: (i) the technology choice between the TDR proposed solution of BaF2 crystals readout with solar blind Avalanche Photodiodes (APDs) and the backup option of CsI crystals readout with Silicon Photomultipliers (SiPM) has been completed and (ii) the channels numbering, the mechanical system and the readout electronics were substantially modified while proceeding with engineering towards the final project. This document updates the description of the calorimeter system adding the most recent engineering drawings and tecnical progresses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPT-SLIM: Line Intensity Mapping with the South Pole Telescope

Line-intensity mapping (LIM) at millimeter wavelengths is a powerful emerging probe of the large-scale structure of the Universe, but achieving meaningful constraints on cosmological parameters with LIM requires focal planes with orders of magnitudes more detectors than existing instruments. SPT-SLIM is an upcoming experiment to demonstrate LIM observations of CO at 0.5 < z < 2.0 using on-chip spectrometers with kinetic inductance detectors (KIDs), a new technology that enables scaling to the much larger arrays of detectors needed to probe cosmology. I will describe the overall experimental design and specific goals of SPT-SLIM. In addition, I will highlight results of the detector and readout electronics development for SPT-SLIM and the status of the camera integration and commissioning in the lab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A demonstrator for a real-time AI-FPGA-based triggering system for sPHENIX at RHIC

The RHIC interaction rate at sPHENIX will reach around 3 MHz in pp collisions and requires the detector readout to reject events by a factor of over 200 to fit the DAQ bandwidth of 15 kHz. Some critical measurements, such as heavy flavor production in pp collisions, often require the analysis of particles produced at low momentum. This prohibits adopting the traditional approach, where data rates are reduced through triggering on rare high momentum probes. We explore a new approach based on real-time AI technology, adopt an FPGA-based implementation using a custom designed FELIX-712 board with the Xilinx Kintex Ultrascale FPGA, and deploy the system in the detector readout electronics loop for real-time trigger decision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid-State Mixed-Potential Electrochemical Sensors for Natural Gas Leak Detection and Quality Control (Final Technical Report)

Mitigation of methane emissions are a critical factor to limiting the impact of the natural gas industry on global climate change. Throughout the period of 2020-2024, the University of New Mexico and its commercialization partner and subcontractor, SensorComm Technologies, Inc. (SCT), have worked together to develop a low-cost Artificial Intelligence (AI)-driven Internet of Things (IoT)-based multi-gas sensor platform for methane emissions detection. In the final year of the project, we extended this work to include hydrogen detection in support of a transition to a hydrogen economy where hydrogen could be transported through existing natural gas infrastructure. Mixed potential electrochemical sensors were first prototyped by ceramic additive manufacturing and then transitioned to conventional ceramic manufacturing tape casting and screen-printing technologies in preparation for mass production. Demonstrated limits of detection of 5 ppm of methane in natural gas and 1 ppm of hydrogen were measured. These limits of detection are among the lowest of solid-state electrochemical sensors that have been reported in the literature or available in the industry. Machine learning algorithms were developed to identify natural gas mixtures with > 98% accuracy level and quantify methane concentrations at 97% accuracy. The presence of hydrogen could also be identified, and its concentration quantified at these accuracy levels. These algorithms were optimized for running on portable computing hardware which enabled > 1 Hz processing rates. A portable packaged IoT system was integrated with the electrochemical sensor in collaboration with SCT. The package consists of readout electronics with < 1 mV resolution, sensor temperature control, and data transmission over cellular wireless and/or Wi-Fi networks. Field testing was performed in two rounds at Colorado State University’s Methane Emissions Technology Evaluation Center (CSU METEC). The first round of testing demonstrated successful measurements of methane from an underground natural gas leak of 20 standard liters per minute (SLPM), which agreed with previously published literature using more sophisticated and expensive analytical equipment. The second round of testing showed that an above ground leak of 2 SLPM of hydrogen could be detected at 32 ft. This project has resulted in six published peer reviewed journal articles, over ten presentations at professional conferences, and one full patent application filed in 2023. Future work on this project includes increased sensitivity, higher production yields, and applications in the hydrogen safety and flare emissions monitoring spaces.

03 NATURAL GAS↗

Memorandum of Understanding for the 2010 MESON Test Beam Program T-1004: Total Absorption Dual Readout Calorimetry R&D

This is a memorandum of understanding between the Fermi National Accelerator Laboratory and experimenters from Fermilab, Caltech, University of Iowa, Argonne National Laboratory, Fairfield University, CERN, INFN Trieste/Udine, INFN Roma I, Shinshu University and the University of Cyprus who have committed to participate in beam tests to be carried out during the 2009/2010 MTBF program. The memorandum is intended solely for the purpose of providing a budget estimate and a work allocation for Fermilab, the funding agencies and the participating institutions. It reflects an arrangement that currently is satisfactory to the parties; however, it is recognized and anticipated that changing circumstances of the evolving research program will necessitate revisions. The parties agree to negotiate amendments to this memorandum which will reflect such required adjustments. The tests have the objective to continue the development of elements and techniques related to total absorption dual readout calorimetry. Until this time, the R&D program has focused on simulations and tests using cosmic rays. The purpose of the program outlined here is to continue this work using particle beams to accelerate the process and to subject the counters and readout electronics to operating intensities and backgrounds with well-defined beam conditions and/or tracking of incident particles. The work will use new prototype electronics developed at Fermilab[1] which will lead to the assembly of future large-scale integrated systems, which may be the subject for a future proposal. For the purpose of this work, the T-1004 experimenters will require limited space and resources and need not always have control of the beam.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Production summary for extended barrel module fabrication at Argonne for the ATLAS tile calorimeter.

The Tile Calorimeter is one of the main hadronic calorimeters to be used in the ATLAS experiment at CERN [1,2]. It is a steel/scintillator sampling calorimeter which is built by stacking 64 segments in azimuth and 3 separate cylinders to provide a total structure whose length is approximately 12m and whose diameter is a little over 8.4m. It has a total weight of about 2630 metric tons. Important features of this calorimeter are: A minimum gap (1.5mm) between modules in azimuth; Pockets in the structure to hold the scintillator tiles; Recessed channels at the edges of the module into which the readout fibers will sit; and Holes in the structure through which a radioactive source will pass. The mechanical structure for one of the 3 calorimeter sections, the Extended Barrel (EBA) was constructed at Argonne. A schematic of the calorimeter sampling structure and the layout of one of the 64 segments, termed a module, are shown in figure 1. Each module comprises mechanically of a precision machined, structural girder to which 10 submodules are bolted. One of these submodules, the ITC, has a customized shape to accommodate services for other detector elements. Each submodule weighs 850Kg and the assembled mechanical structure of the module weighs approximately 9000Kg (a fully instrumented Extended Barrel modules weighs {approx}9600Kg). A crucial issue for the tile calorimeter assembly is the minimization of the un-instrumented gap between modules when they are stacked on top of each other during final assembly. The design goal was originally 1mm gap which was eventually relaxed to 1.5mm following a careful evaluation of all tolerances in the construction and assembly process as shown in figure 2 [3]. Submodules for this assembly were produced at 4 locations [4] using tooling and procedures which were largely identical [5]. An important issue was the height of each submodule on the stacking fixture on which they were fabricated as this defines the length along the girder for installation, with a design gap between submodules on the girder of 0.3mm. During production we relaxed this tolerance to +0.3, -1.5mm. The height summary for submodules used at Argonne is shown in Appendix I. About 10 submodules fell outside the positive height envelope (due to the raw plate thickness being out of specification) and we constructed some custom short submodules to allow their use in module assembly. The structural girders were produced commercially following the Quality Control plan agreed to with the Tile Calorimeter collaboration and shipped to Argonne. The crucial tolerances on the girder are the key into which submodules are placed as well as the flatness of the key surface which are used in aligning submodules such that the azimuthal surface lies wholly an envelope of +0.75mm from nominal [6]. Another important characteristic of the girder are clearance holes through which the wavelength shift fibers pass to couple the light to photomultipliers located inside the girder, as described in [2]. Since these fiber bundles must be located to high precision, rather than position the holes in the steel to this precision, tooling was developed by which the precision pieces are glued into the girder [7]. This is shown in figure 3. More details on the pieces used to accomplish this interface to the readout electronics are discussed in [2].

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Top quark pair production cross section in the lepton+jets channel using b-tagging at D0

The top quark pair production cross section measurement in the lepton+jets channel with b-tagging algorithm is described. About 900 pb -1 data collected by the D0 detector at the Fermilab Tevatron are used for this analysis. In this thesis, event selection, background estimation, and cross section calculation are discussed in detail. In addition, calibration of the Luminosity Monitor readout electronics and a new b-tagging algorithm, the SLTNN tagger, are also discussed in this thesis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Novel Large Area High Resolution Neutron Detector for the Spallation Neutron Source

Neutron scattering is a powerful technique that is critically important for materials science and structural biology applications. The knowledge gained from past developments has resulted in far-reaching advances in engineering, pharmaceutical and biotechnology industries, to name a few. New facilities for neutron generation at much higher flux, such as the SNS at Oak Ridge, TN, will greatly enhance the capabilities of neutron scattering, with benefits that extend to many fields and include, for example, development of improved drug therapies and materials that are stronger, longer-lasting, and more impact-resistant. In order to fully realize this enhanced potential, however, higher neutron rates must be met with improved detection capabilities, particularly higher count rate capability in large size detectors, while maintaining practicality. We have developed a neutron detector with the technical and economic advantages to accomplish this goal. This new detector has a large sensitive area, offers 3D spatial resolution, high sensitivity and high count rate capability, and it is economical and practical to produce. The proposed detector technology is based on B-10 thin film conversion of neutrons in long straw-like gas detectors. A stack of many such detectors, each 1 meter in length, and 4 mm in diameter, has a stopping power that exceeds that of He-3 gas, contained at practical pressures within an area detector. With simple electronic readout methods, straw detector arrays can provide spatial resolution of 4 mm FWHM or better, and since an array detector of such form consists of several thousand individual elements per square meter, count rates in a 1 m^2 detector can reach 2?10^7 cps. Moreover, each individual event can be timetagged with a time resolution of less than 0.1 ?sec, allowing accurate identification of neutron energy by time of flight. Considering basic elemental cost, this novel neutron imaging detector can be commercially produced economically, probably at a small fraction of the cost of He-3 detectors. In addition to neutron scattering science, the fully developed base technology can be used as a rugged, low-cost neutron detector in area monitoring and surveying. Radiation monitors are used in a number of other settings for occupational and environmental radiation safety. Such a detector can also be used in environmental monitoring and remote nuclear power plant monitoring. For example, the Department of Energy could use it to characterize nuclear waste dumps, coordinate clean-up efforts, and assess the radioactive contaminants in the air and water. Radiation monitors can be used to monitor the age and component breakdown of nuclear warheads and to distinguish between weapons and reactor grade plutonium. The UN's International Atomic Energy Agency (IAEA) uses radiation monitors for treaty verification, remote monitoring, and enforcing the non-proliferation of nuclear weapons. As part of treaty verification, monitors can be used to certify the contents of containers during inspections. They could be used for portal monitoring to secure border checkpoints, sea ports, air cargo centers, public parks, sporting venues, and key government buildings. Currently, only 2% of all sea cargo shipped is inspected for radiation sources. In addition, merely the presence of radiation is detected and nothing is known about the radioactive source until further testing. The utilization of radiation monitors with neutron sensitivity and capability of operation in hostile port environments would increase the capacity and effectiveness of the radioactive scanning processes.

47 OTHER INSTRUMENTATION↗

Development of a 10 picosecond time-of-flight Counter

This Advanced Detector Research proposal presented a plan to develop an extremely fast time-of-flight detector for measuring the arrival time of beam protons scattered at small angles in high energy hadron colliders, such as the Large Hadron Collider (LHC). The proposed detectors employ a gas or quartz Cerenkov radiator which produce light when a proton passes through them, coupled to a micro-channel plate photomultiplier tube (MCP-PMT) that converts the light to an electrical pulse. The very small jitter of the pulse time provided by the MCP-PMT, combined with downstream electronics that accurately measure the pulse time results in a time-of-flight measurement of unprecedented accuracy. This ADR proposal was extremely successful, culminating in the development of a 10 ps resolution time-of-flight system, about an order of magnitude better than any time-of-flight system previously deployed at a collider experiment. The primary areas of advance were the usage of new radiator geometries providing fast detector signals, using multiple measurements to obtain a superior system resolution, and development of an electronics readout system tuned to maintain the excellent timing afforded by the detector. Test beam and laser tests have improved the knowledge of MCP-PMT’s and enabled the evaluation of the new detector concepts. In addition to being a generally useful detector concept, these fast timing detectors are a major component of proposed upgrades to the LHC ATLAS and CMS detectors, and if deployed could significantly enhance the discovery potential of these detectors, including contributions to the measurement of the properties of the Higgs Boson. In addition to the potential for furthering fundamental understanding of nature, the knowledge gained on MCP-PMT’s could be useful in developing improved versions of these devices which have promise in diverse fields such as biological and medical imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The EBEX Balloon-borne Experiment—Gondola, Attitude Control, and Control Software

The E and B Experiment (EBEX) was a long-duration balloon-borne instrument created to measure the polarization of the cosmic microwave background (CMB) radiation. EBEX was the first balloon-borne instrument to implement a kilopixel array of transition edge sensor (TES) bolometric detectors and the first CMB experiment to use the digital version of the frequency domain multiplexing system for readout of the TES array. The scan strategy relied on 40 s peak-to-peak constant-velocity azimuthal scans. We report on the unique demands on the design and operation of the payload that resulted from these new technologies and the scan strategy. We describe the solutions implemented, including the development of a power system designed to provide a total of at least 2.3 kW, a cooling system to dissipate 590 W consumed by the detectors' readout system, software to manage and handle the data of the kilopixel array, and specialized attitude reconstruction software. We demonstrate flight performance data reflecting faultless management of the TES array, adequate powering and cooling of the readout electronics, and constraint of attitude reconstruction errors such that the spurious B-modes they induced were less than 10% of the CMB B-mode power spectrum with r = 0.05.

polarization↗

Quench dynamics in SRF cavities: can we locate the quench origin with 2nd sound?

A newly developed method of locating quenches in SRF cavities by detecting second-sound waves has been gaining popularity in SRF laboratories. The technique is based on measurements of time delays between the quench as determined by the RF system and arrival of the second-sound wave to the multiple detectors placed around the cavity in superfluid helium. Unlike multi-channel temperature mapping, this approach requires only a few sensors and simple readout electronics; it can be used with SRF cavities of almost arbitrary shape. One of its drawbacks is that being an indirect method it requires one to solve an inverse problem to find the location of a quench. We tried to solve this inverse problem by using a parametric forward model. By analyzing the data we found that the approximation where the second-sound emitter is a near-singular source does not describe the physical system well enough. A time-dependent analysis of the quench process can help us to put forward a more adequate model. We present here our current algorithm to solve the inverse problem and discuss the experimental results.

43 PARTICLE ACCELERATORS↗

X-ray and gamma ray detector readout system

A readout electronics scheme is under development for high resolution, compact PET (positron emission tomography) imagers based on LSO (lutetium ortho-oxysilicate, Lu.sub.2SiO.sub.5) scintillator and avalanche photodiode (APD) arrays. The key is to obtain sufficient timing and energy resolution at a low power level, less than about 30 mW per channel, including all required functions. To this end, a simple leading edge level crossing discriminator is used, in combination with a transimpedance preamplifier. The APD used has a gain of order 1,000, and an output noise current of several pA/ Hz, allowing bipolar technology to be used instead of CMOS, for increased speed and power efficiency. A prototype of the preamplifier and discriminator has been constructed, achieving timing resolution of 1.5 ns FWHM, 2.7 ns full width at one tenth maximum, relative to an LSO/PMT detector, and an energy resolution of 13.6% FWHM at 511 keV, while operating at a power level of 22 mW per channel. Work is in progress towards integration of this preamplifier and discriminator with appropriate coincidence logic and amplitude measurement circuits in an ASIC suitable for a high resolution compact PET instrument. The detector system and/or ASIC can also be used for many other applications for medical to industrial imaging.

Tumer, Tumay O↗

Lifetime studies of 130nm nMOS transistors intended for long-duration, cryogenic high-energy physics experiments.

Future neutrino physics experiments intend to use unprecedented volumes of liquid argon to fill a time projection chamber in an underground facility. To increase performance, integrated readout electronics should work inside the cryostat. Due to the scale and cost associated with evacuating and filling the cryostat, the electronics will be unserviceable for the duration of the experiment. Therefore, the lifetimes of these circuits must be well in excess of 20 years. The principle mechanism for lifetime degradation of MOSFET devices and circuits operating at cryogenic temperatures is via hot carrier degradation. Choosing a process technology that is, as much as possible, immune to such degradation and developing design techniques to avoid exposure to such damage are the goals. This requires careful investigation and a basic understanding of the mechanisms that underlie hot carrier degradation and the secondary effects they cause in circuits. In this work, commercially available 130nm nMOS transistors operating at cryogenic temperatures are investigated. The results show that the difference in lifetime for room temperature operation and cryogenic operation for this process are not great and the lifetimes at both 300K and at 77K can be projected to more than 20 years at the nominal voltage (1.5V) for this technology.

43 PARTICLE ACCELERATORS↗

Photodiode-Based X-Ray Beam-Position Monitor With High Spatial-Resolution for the NSLS-II Beamlines

We developed a photodiode-based monochromatic X-ray beam-position monitor (X-BPM) with high spatial resolution for the project beamlines of the NSLS-II. A ring array of 32 Si PIN-junction photodiodes were designed for use as a position sensor, and a low-noise HERMES4 ASIC chip was integrated into the electronic readout system. A series of precision measurements to characterize electrically the Si-photodiode sensor and the ASIC chip demonstrated that the inherent noise is sufficiently below tolerance levels. Following up modeling of detector's performance, including geometrical optimization using a Gaussian beam, we fabricated and assembled a first prototype. In this paper, we describe the development of this new state-of-the-art X-ray BPM along the beamline, in particular, downstream from the monochromator.

36 MATERIALS SCIENCE↗

Fast-neutron coded-aperture imaging of special nuclear material configurations

In the past year, a prototype fast-neutron coded-aperture imager has been developed that has sufficient efficiency and resolution to make the counting of warheads for possible future treaty confirmation scenarios via their fission-neutron emissions practical. The imager is constructed from custom-built pixelated liquid scintillator detectors. The liquid scintillator detectors enable neutron-gamma discrimination via pulse shape, and the pixelated construction enables a sufficient number of pixels for imaging in a compact detector with a manageable number of channels of readout electronics. The imager has been used to image neutron sources at ORNL, special nuclear material (SNM) sources at the Idaho National Laboratory (INL) Zero Power Physics Reactor (ZPPR) facility, and neutron source and shielding configurations at Sandia National Laboratories. This paper reports on the design and construction of the imager, characterization measurements with neutron sources at ORNL, and measurements with SNM at the INL ZPPR facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast neutron coded-aperture imaging of special nuclear material configurations

In the past year, a prototype fast-neutron coded-aperture imager has been developed that has sufficient efficiency and resolution to make the counting of warheads for possible future treaty confirmation scenarios via their fission-neutron emissions practical. The imager is constructed from custom-built pixelated liquid scintillator detectors. The liquid scintillator detectors enable neutron-gamma discrimination via pulse shape, and the pixelated construction enables a sufficient number of pixels for imaging in a compact detector with a manageable number of channels of readout electronics. The imager has been used to image neutron sources at ORNL, special nuclear material (SNM) sources at the Idaho National Laboratory (INL) Zero Power Physics Reactor (ZPPR) facility, and neutron source and shielding configurations at Sandia National Laboratories. This paper reports on the design and construction of the imager, characterization measurements with neutron sources at ORNL, and measurements with SNM at the INL ZPPR facility.

Hausladen, Paul↗