Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Raman Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Surface-enhanced raman spectroscopy substrate for arsenic sensing in groundwater

A surface-enhanced Raman spectroscopy (SERS) substrate formed from a plurality of monolayers of polyhedral silver nanocrystals, wherein at least one of the monolayers has polyvinypyrrolidone (PVP) on its surface, and thereby configured for sensing arsenic is described. Highly active SERS substrates are formed by assembling high density monolayers of differently shaped silver nanocrystals onto a solid support. SERS detection is performed directly on this substrate by placing a droplet of the analyte solution onto the nanocrystal monolayer. Adsorbed polymer, polyvinypyrrolidone (PVP), on the surface of the nanoparticles facilitates the binding of both arsenate and arsenite near the silver surface, allowing for highly accurate and sensitive detection capabilities.

36 MATERIALS SCIENCE↗

Analysis of organic pollutant degradation in pulsed plasma by coherent anti-Stokes Raman spectroscopy

The degradation of p-benzoquinone (p-BQ) in water was investigated by the coherent anti-Stokes Raman spectroscopy (CARS) method, in which the change of the anti-Stokes signal intensity corresponding to the vibrational transitions of the molecule is monitored during and after solution plasma processing (SPP). In the beginning of SPP treatment, the CARS signal intensity of the ring vibrational molecular transitions at 1233 and 1660 cm{sup -1} increases under the influence of the electric field of the plasma, depending on the delay time between the plasma pulse and the laser firing pulse. At the same time, the plasma contributes to the degradation of p-BQ molecules by generating hydrogen and hydroxyl radicals, which decompose p-BQ into different carboxylic acids. After SPP, the CARS signal intensity of the vibrational bands of p-BQ ceased and the degradation of p-BQ was confirmed by UV-visible absorption spectroscopy and liquid chromatography analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Shocked chromites in fossil L chondrites: A Raman spectroscopy and transmission electron microscopy study

Abstract Chromites from Middle Ordovician fossil L chondrites and from matrix and shock‐melt veins in Catherwood, Tenham, and Coorara L chondrites were studied using Raman spectroscopy and TEM . Raman spectra of chromites from fossil L chondrites showed similarities with chromites from matrix and shock‐melt veins in the studied L chondrite falls and finds. Chromites from shock‐melt veins of L chondrites show polycrystallinity, while the chromite grains in fossil L chondrites are single crystals. In addition, chromites from shock‐melt veins in the studied L chondrites have high densities of planar fractures within the subgrains and many subgrains show intergrowths of chromite and xieite. Matrix chromite of Tenham has similar dislocation densities and planar fractures as a chromite from the fossil meteorite Golvsten 001 and higher dislocation densities than in chromite from the fossil meteorite Sextummen 003. Using this observation and knowing that the matrix of Tenham experienced 20–22 GP a and <1000° C, an upper limit for the P,T conditions of chromite from Golvsten 001 and Sextummen 003 can be estimated to be 20–22 GP a and 1000° C (shock stage S3–S6) and 20 GP a and 1000° C (S3–S5), respectively, and we conclude that the studied fossil meteorite chromites are from matrix.

Rout, Surya S.↗

New insight into UO 2 F 2 particulate structure by micro-Raman spectroscopy

Uranyl fluoride particles produced via hydrolysis of uranium hexafluoride have been deposited on different substrates: polished graphite disks, silver foil, stainless steel and gold-coated silicon wafer, and measured with micro-Raman spectroscopy (MRS). All three metallic substrates enhanced the Raman signal delivered by UO 2 F 2 in comparison to graphite. The fundamental stretching of the U–O band appeared at 867 cm –1 in case of the graphite substrate, while in case of the others it was shifted to lower frequencies (down to 839 cm –1 ). All applied metallic substrates showed the expected effect of Raman signal enhancement; however the gold layer appeared to be most effective. Lastly, application of new substrates provides more information on the molecular structure of uranyl fluoride precipitation, which is interesting for nuclear safeguards and nuclear environmental analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Depth-resolved confocal micro-Raman spectroscopy for characterizing GaN-based light emitting diode structures

In this work, we demonstrate that depth-resolved confocal micro-Raman spectroscopy can be used to characterize the active layer of GaN-based LEDs. By taking the depth compression effect due to refraction index mismatch into account, the axial profiles of Raman peak intensities from the GaN capping layer toward the sapphire substrate can correctly match the LED structural dimension and allow the identification of unique Raman feature originated from the 0.3 μm thick active layer of the studied LED. The strain variation in different sample depths can also be quantified by measuring the Raman shift of GaN A{sub 1}(LO) and E{sub 2}(high) phonon peaks. The capability of identifying the phonon structure of buried LED active layer and depth-resolving the strain distribution of LED structure makes this technique a potential optical and remote tool for in operando investigation of the electronic and structural properties of nitride-based LEDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchrotron radiation-induced contamination on LiF window: Characterization by Raman spectroscopy

Characterization of synchrotron induced contamination on optical elements and their cleaning are serious issues in beam lines. We used Raman spectroscopy for characterization of synchrotron induced contamination layer on LiF window (used in high resolution vacuum ultra violet beam line). Three peaks at 1035 cm{sup −1} (corresponding to C-C sp{sup 3} vibrations), 1563 cm{sup −1} and 1375 cm{sup −1} (corresponding to G and D bands of carbon) are observed. By data fitting I(D)/I(G) ratio (0.84) and FWHM(G)=124 cm{sup −1} was obtained. Comparison with available literature indicates that the carbon might be present in the form of rings of hydrogenated amorphous carbon a-C:H (GLHC) with atomic hydrogen concentration about 15% with both sp{sup 2} and sp{sup 3} hybridization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measuring Hydroxylammonium, Nitrate, and Nitrite Concentration with Raman Spectroscopy for 238 Pu Supply Program

Optical spectroscopy has great potential to improve the timeliness of important analytical measurements for the 238 Pu Supply Program by enabling real-time analysis of process solutions within radiochemical hot cells. Hydroxylammonium (H 3 NOH + ]), nitrate (NO 3 - ), and nitrite (NO 2 - ) are three important molecular species present in multiple aqueous streams throughout the program’s flow sheet. The concentration of each species normally goes uncharacterized during processing. However, rapid quantification may benefit the program because uncertainties in kinetic redox expressions describing hydroxylammonium (HA) and nitrite reactions with Np and Pu leads to uncertainty in process model predictions for solvent extraction runs. HA concentration is normally quantified using ion chromatography, a technique that requires diluted grab samples taken out of the hot cell and analyzed off-line. Here we evaluate Raman spectroscopy for determining the concentration of H 3 NOH + , NO 3 - , and NO 2 - in benchtop tests to determine limits of detection. We also consider the possibility of using Raman spectroscopy in both glove box and hot cell environments for rapid analysis and pinpoint additional development opportunities needed to make this application successful.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Resonant Stimulated X-ray Raman Spectroscopy of Mixed-Valence Manganese Complexes

Resonant stimulated X-ray Raman spectroscopy of the bimetallic [Mn III Mn IV (μ-O) 2 (μ-OAC)(tacn) 2 ] 2+ manganese complex is investigated in a simulation study. A pump–probe sequence of resonant X-ray Raman excitations is employed to generate and monitor valence-electron wave packets at selected regions in the molecule, by exploiting element specific core-excited states. A two-color protocol is presented, with pump and probe pulses tuned to the Mn and N K-edges. A natural orbital decomposition allows the visualization of the electron dynamics underlying the signal.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimized Substrates and Measurement Approaches for Raman Spectroscopy of Graphene Nanoribbons

The on-surface synthesis of graphene nanoribbons (GNRs) allows for the fabrication of atomically precise narrow GNRs. Despite their exceptional properties which can be tuned by ribbon width and edge structure, significant challenges remain for GNR processing and characterization. In this work, Raman spectroscopy is used to characterize different types of GNRs on their growth substrate and track their quality upon substrate transfer. A Raman-optimized (RO) device substrate and an optimized mapping approach are presented that allow for the acquisition of high-resolution Raman spectra, achieving enhancement factors as high as 120 with respect to signals measured on standard SiO 2 /Si substrates. This approach is well suited to routinely monitor the geometry-dependent low-frequency modes of GNRs. In particular, the radial breathing-like mode (RBLM) and the shear-like mode (SLM) for 5-, 7-, and 9-atom-wide armchair GNRs (AGNRs) are tracked and their frequencies are compared with first-principles calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-Pressure Raman Spectroscopy and X-ray Diffraction Studies of a Terpolymer of Tetrafluoroethylene-Hexafluoropropylene-Vinylidene Fluoride: THV 500

High-pressure Raman spectroscopy and X-ray diffraction of THV 500, a terpolymer of tetrafluoroethylene-hexafluoropropylene-vinylidene fluoride, were performed using diamond anvil cells (DAC). Changes in the interatomic spacing as well as shifts of several of the vibrational bands as a function of pressure were measured up to {approx}10 GPa. The changes in interatomic spacing and shifts of the vibrational bands are compared to those of polytetrafluoroethylene, showing the effects of copolymerization and reduced crystallinity. The high-pressure behavior of polymers is a relatively unexplored field but is becoming increasingly important due to applications where polymers experience extreme conditions.

36 MATERIALS SCIENCE↗

Two-beam ultrabroadband coherent anti-Stokes Raman spectroscopy for high resolution gas-phase multiplex imaging

We propose and develop a method for wideband coherent anti-Stokes Raman spectroscopy (CARS) in the gas phase and demonstrate the single-shot measurement of N{sub 2}, H{sub 2}, CO{sub 2}, O{sub 2}, and CH{sub 4}. Pure-rotational and vibrational O-, Q-, and S- branch spectra are collected simultaneously, with high spectral and spatial resolution, and within a single-laser-shot. The relative intensity of the rotational and vibrational signals can be tuned arbitrarily using polarization techniques. The ultrashort 7 fs pump and Stokes pulses are automatically overlapped temporally and spatially using a two-beam CARS technique, and the crossed probe beam allows for excellent spatial sectioning of the probed location.

74 ATOMIC AND MOLECULAR PHYSICS↗

Temperature dependent Raman spectroscopy of chemically derived few layer MoS{sub 2} and WS{sub 2} nanosheets

We have systematically investigated the temperature dependent Raman spectroscopy behavior of a few layered MoS{sub 2} and WS{sub 2} nanosheets synthesized using simple hydrothermal method. Our result reveals A{sub 1g} and E{sup 1}{sub 2g} modes soften as temperature increases from 77 K to 623 K. This behavior can be explained in terms of a double resonance process which is active in single- and few layer thick nanosheets. The frequency shifts and peak broadening can provide unambiguous, nondestructive, and accurate information of a few layered MoS{sub 2} and WS{sub 2}. This mechanism can also be applicable in characterizing the structural, optical, electronic, and vibrational properties of other emerging layered materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Isotopic Signatures of Lithium Carbonate and Lithium Hydroxide Monohydrate Measured Using Raman Spectroscopy

Lithium isotopic ratios have wide ranging applications as chemical signatures, including improved understanding of geochemical processes and battery development. Measurement of isotope ratios using optical spectroscopies would provide an alternative to traditional mass spectrometric methods, which are expensive and often limited to a chemical laboratory. In this work, Raman spectra of 7 Li 2 CO 3 , 6 Li 2 CO 3 , 7 LiOH*H 2 O and 6 LiOH*H 2 O have been measured to determine the effect of lithium isotope substitution on the Raman molecular vibrations. Thirteen peaks were observed in the spectrum of lithium carbonate, with discernable isotopic shifts occurring in eleven of the thirteen vibrations, two of which have not been previously reported in the literature. The spectrum of lithium hydroxide monohydrate contained nine peaks, with discernable isotopic shifts occurring in eight of the nine vibrations, four of which have not been previously reported in the literature. The Raman spectral data reported here for lithium carbonate and lithium hydroxide monohydrate are in agreement with the previously reported works in the literature, in which the Raman active modes of these molecules were first identified and assigned. However, due to the stability and resolution of the detection system used in this work, isotopic shifts with a magnitude less than one wavenumber have been identified. Principal Component Regression was used to evaluate the sensitivity to isotopic content of small Raman peak shifts in Li 2 CO 3 and indicates differences greater than 2 atom-% could be reliably determined. These measurements add to the body of work on lithium isotope Raman spectroscopy for these two compounds and increases the number of Raman bands which could be used for lithium isotope content analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microstructural origin of high‐strength Tyranno SA4 SiC fiber studied by comparative Raman spectroscopy #

Tyranno SA4 grade SiC fiber is an emerging continuous fiber with excellent mechanical properties. The origin of the fiber's high-performance was studied by comparative Raman spectroscopy of four different grades of SiC fibers and reference SiC monolith. Analysis of the Raman spectra of fiber cross-sections, surface and homogeneity, and fibers under stress, revealed how differences in microstructure, such as crystalline order, size, and the presence of critical flaws, dictate mechanical properties. In conclusion, this information can help optimize SiC fiber manufacturing.

36 MATERIALS SCIENCE↗

E{sub 1} Gap of Wurtzite InAs Single Nanowires Measured by Means of Resonant Raman Spectroscopy

Indium arsenide nanowires were synthesized with an intermixing of wurtzite and zincblende structure by chemical beam epitaxy with the vapor-liquid-solid mechanism. Resonant Raman spectroscopy of the transverse optical phonon mode at 215 cm{sup -1} reveals an E{sub 1} gap of 2.47 eV which is assigned to the electronic band gap at the A point in the indium arsenide wurtzite phase.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High pressure structural study of {beta}-Ti{sub 3}O{sub 5}: X-ray diffraction and Raman spectroscopy

The structural stability of {beta}-Ti{sub 3}O{sub 5} (C2/m) has been investigated by X-ray diffraction and Raman spectroscopy with diamond anvil cells. {beta}-Ti{sub 3}O{sub 5} is stable up to about 26 GPa at room temperature. Isothermal pressure-volume relationship of {beta}-Ti{sub 3}O{sub 5} is well presented by the third-order Birch-Murnaghan equation of state with V{sub 0}=348.6(8) A{sup 3} and B{sub 0}=216(9) GPa. Axial compressibility presents obvious anisotropy. The a-axis and c-axis are more compressible than b-axis due to the different crystal structure arrangement of {beta}-Ti{sub 3}O{sub 5} along b-axis and perpendicular to b-axis direction. The Grueneisen parameters of thirteen observed Raman modes are 0.79-1.74, whose mean is 1.32. - Graphical abstract: The crystal structure of {beta}-Ti{sub 3}O{sub 5}: the projection of {beta}-Ti{sub 3}O{sub 5} along b-axis (Left) and the projection of {beta}-Ti{sub 3}O{sub 5} along c-axis (Right). Highlights: Black-Right-Pointing-Pointer High pressure structural stability of {beta}-Ti{sub 3}O{sub 5} was investigated. Black-Right-Pointing-Pointer {beta}-Ti{sub 3}O{sub 5} is stable up to about 26 GPa. Black-Right-Pointing-Pointer Axial compressibility presents obvious anisotropy. Black-Right-Pointing-Pointer Pressure-volume relationship is well presented by Birch-Murnaghan equation of state. Black-Right-Pointing-Pointer The Grueneisen parameters are 0.79-1.74.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

REMOTE RAMAN SPECTROSCOPY OF VARIOUS MIXED AND COMPOSITE MINERAL PHASES AT 7.2 m DISTANCE

Remote Raman [e.g.,1-5] and micro-Raman spectroscopy [e.g., 6-10] are being evaluated on geological samples for their potential applications on Mars rover or lander. The Raman lines of minerals are sharp and distinct. The Raman finger-prints of minerals do not shift appreciably but remain distinct even in sub-micron grains and, therefore, can be used for mineral identification in fine-grained rocks [e.g., 4,7]. In this work we have evaluated the capability of a directly coupled remote Raman system (co-axial configuration) for distinguishing the mineralogy of multiple crystals in the exciting laser beam. We have measured the Raman spectra of minerals in the near vicinity of each other and excited with a laser beam (e.g. -quartz (Qz) and K-feldspar (Feld) plates, each 5 mm thick). The spectra of composite transparent mineral plates of 5 mm thickness of -quartz and gypsum over calcite crystal were measured with the composite samples perpendicular to the exciting laser beam. The measurements of remote Raman spectra of various bulk minerals, and mixed and composite minerals with our portable UH remote Raman system were carried out at the Langley Research Center in a fully illuminated laboratory.

Sharma, S. K.↗