High-speed, two-dimensional synchrotron white-beam x-ray radiography of spray breakup and atomization

High-speed, two-dimensional synchrotron x-ray radiography and phase-contrast imaging are demonstrated in propulsion sprays. Measurements are performed at the 7-BM beamline at the Advanced Photon Source user facility at Argonne National Laboratory using a recently developed broadband x-ray white beam. This novel enhancement allows for high speed, high fidelity x-ray imaging for the community at large. Quantitative path-integrated liquid distributions and spatio-temporal dynamics of the sprays were imaged with a LuAG:Ce scintillator optically coupled to a high-speed CMOS camera. Images are collected with a microscope objective at frame rates of 20 kHz and with a macro lens at 120 kHz, achieving spatial resolutions of 12 μm and 65 μm, respectively. Imaging with and without potassium iodide (KI) as a contrast-enhancing agent is compared, and the effects of broadband attenuation and spatial beam characteristics are determined through modeling and experimental calibration. In addition, phase contrast is used to differentiate liquid streams with varying concentrations of KI. The experimental approach is applied to different spray conditions, including quantitative measurements of mass distribution during primary atomization and qualitative visualization of turbulent binary fluid mixing. High-speed, two-dimensional synchrotron white-beam x-ray radiography of spray breakup and atomization. Available from: https://www.researchgate.net/publication/312567827_High-speed_two-dimensional_synchrotron_white-beam_x-ray_radiography_of_spray_breakup_and_atomization [accessed Aug 31, 2017].

Halls, Benjamin R.↗

Quantitative time-averaged gas and liquid distributions using x-ray fluorescence and radiography in atomizing sprays

A method for quantitative measurements of gas and liquid distributions is demonstrated using simultaneous x-ray fluorescence and radiography of both phases in an atomizing coaxial spray. Synchrotron radiation at 10.1 keV from the Advanced Photon Source at Argonne National Laboratory is used for x-ray fluorescence of argon gas and two tracer elements seeded into the liquid stream. Simultaneous time-resolved x-ray radiography combined with time-averaged dual-tracer fluorescence measurements enabled corrections for reabsorption of x-ray fluorescence photons for accurate, line-of-sight averaged measurements of the distribution of the gas and liquid phases originating from the atomizing nozzle.

absorption↗

Analysis Methods for Electron Radiography Based on Laser-Plasma Accelerators

Analysis methods are presented for determining the resolution of both contact and projected electron radiography based on a laser-plasma accelerator. A means to determine the field strength of the electric/magnetic fields generated when a laser is incident on an object of interest is also out-lined. Broad radiography results are reported and future plans for the diagnostic technique are outlined.

43 PARTICLE ACCELERATORS↗

Technical Advice and Support for the Joint Integrated Non-Intrusive Inspection (JINII) Program Task 2.2 Transmission Digital Radiography (DR)

The Cargo Advanced Automated Radiography System (CAARS) program aims to utilize advanced radiographic systems to detect radiological and nuclear threats. Validation of initial design and testing concepts is a precondition for prototype system development and large-scale deployment. As expected, Depleted Uranium (DU) is a valid surrogate for Special Nuclear Materials (SNM) in CAARS Advanced Technology Demonstration (ATD) performance field-tests of transmission radiography systems. Dual-energy transmission measurements of DU are nearly identical to SNM, and are distinct from lower Z materials, provided the samples are matched to equal areal density. Results from an alternative method, using samples of equal thickness, showed sample discrimination by material density, rather than by atomic number (Z). The transmission measurements of DU and SNM were made with equipment that is nearly identical to current field systems. X-ray source beams at endpoint energies of 5.4 MeV and 9.6 MeV were used to measure transmission through the selected sample materials. The ratio of the x-ray linear attenuation coefficient times length ({micro}L) at 5.4 MeV, to {micro}L at 9.6 MeV is a metric for atomic number based discrimination of materials. The measured ratios were compared with computed values based on LLNL photon cross section data and LLNL developed models of x-ray detector characteristics. Measured ratios for DU differed from HEU by an average of 0.25%, and from WGPu by 0.08%, which is within the noise level of 0.4 to 0.5%. For comparison, measured ratios for Sn differed from HEU by 3.2%, and from WGPu by 3.6%, well beyond the measurement noise. Measured ratios for W differed from HEU by 0.01%, and from WGPu by 0.32%. The measured ratio values presented in Table 1 demonstrate the feasibility of using a threshold ratio to discriminate low-Z (Z < 72) from high-Z (Z {ge} 72) materials (as defined by CAARS specification). In the case of our test system, a threshold ratio of 1.08 would be suitable based on the measured results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interfacing the X-Ray Toolkit and the PYTHON Radiography Analysis Tool Final Report for FY12

This document is the final report for the X-Ray Toolkit (XTK) and the PYTHON Radiography Analysis Tool (PyRAT) merger for project LANL12-RS-107J in FY12. This project involves merging the radiography analysis capabilities in PyRAT with the image processing capabilities of XTK. The merger is the focus of project LANL12-RS 107J at Los Alamos National Laboratory (LANL) and SNL12-RS-107J at Sandia National Laboratory.

Radiology & Nuclear Medicine(62)↗

The Effectiveness of the Compton Radiography Snout Electron Deflection Yoke and its Application as an Electron Spectrometer

The Compton Radiography Snout (CRS) is a prototype of a diagnostic called the High Energy X Ray Imager (HEXRI) that will be used to record radiographs of imploding fuel cells on NIF. With these radiographs, it is possible to characterize the density and symmetry of the imploding fuel capsule. When the advanced radiography capability is used to generate the high energy x‐rays used to backlight the radiographs, hot electrons are also produced. In order to record a clear radiograph, these electrons are deflected away from the imaging plane of the CRS using a permanent magnetic yoke. In an effort to increase the number of parameters that can be used during the scaling of the CRS for NIF, an investigation is underway to add an electron spectrometer capability to the CRS to measure the electron spectrum produced during the ARC backlighting.

42 ENGINEERING↗

Muon Radiography for Non-Destructive, Non-Invasive Assay and Long-Term Monitoring of Nuclear Fuel Debris and Fuel Assemblies.

We propose developing a muon cosmic ray radiography system dedicated to the task of assay and long-term safeguard monitoring of Fukushima fuel debris or fuel assemblies. The system would be non-destructive and non-invasive, using naturally occurring cosmic radiation to assay the entire volume of the fuel debris container. The technique distinguishes between materials and is especially sensitive to measuring the location and amount of heavy elements such as uranium and plutonium. Scope of the feasibility study would encompass a) demonstrating material assay (location and amount) of a regular-shaped depleted uranium object sealed in a debris container, and b) repeating the material assay of debris-proxy materials of irregular shape (corium), sealed in a debris container. Muon radiography of each container would result in a unique “fingerprint” of the contents, useful for long-term safeguards monitoring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AOT & LANSCE Focus: Proton Radiography Facility

Invented at Los Alamos National Laboratory, proton radiography (pRad) at the Los Alamos Neutron Science Center (LANSCE) employs a high-energy proton beam to image the properties and behavior of materials under a variety of conditions. The penetrating power of high-energy protons, like that of x-rays, makes them an excellent probe of a wide range of materials under extreme pressures, strains, and strain rates. The invention of proton radiography is the direct result of the synergy between the Laboratory’s defense mission and basic science research scientists and supports the Laboratory’s national security science mission as well as provides for fundamental science discoveries. This new capability has revolutionized dynamic materials science at Los Alamos, providing a new window for the study of shock physics, materials damage, and high explosives science. The Proton Radiograpy Facility, a national user facility, has performed more than 500 dynamic experiments in support of the Weapons program, Global Security, and other customers since it was commissioned more than a decade ago. This information helps Los Alamos maintain the reliability of the U.S. nuclear stockpile. The pRad capability is primarily supported by the NNSA Science Campaigns.

36 MATERIALS SCIENCE↗

SLAC National Accelerator Laboratory FACET & TEST BEAM FACILITIES PROPOSAL: Development of Electron Radiography for Material Science

The material science community is presently limited by diagnostics in both the fabrication of materials and measuring the resulting materials characteristics of these new fabrication techniques. Because of this limitation the community is forced into an empirical mode of material fabrication, where expert judgment is used to guide manufacturing processes and the resulting materials are inspected and tested for the desired characteristics. This development approach can be time consuming and costly. The solution to this problem is to improve our fundamental understanding of materials, which requires the development of new diagnostics capable of measurement at the micron length scale, during both processing and during testing. These new measurements will enable a fundamental understanding of material characteristics allowing the development of predictive models, which will in turn enable material engineering by design rather than today’s empirical approach. Solving this problem has become a grand challenge for the materials science community. Los Alamos plans to address this challenge through the development of new diagnostics capable of measurements at the smallest length scales through the Multi-Probe Diagnostic Hall (MPDH) at the planned MaRIE (Material and Radiation In Extremes) Facility. One of the probes will be a coherent photon beam generated by an FEL driven by a multi-GeV electron beam. The photons will be used for diffraction measurements as well as radiography of relatively thin samples (nearly single grains). The same multi-GeV electron beam can be used to directly radiograph thicker systems (many grains or “bulk” material), providing high resolution measurements of the density distribution of materials during both fabrication and dynamic testing. This technique, electron radiography or eRad, that has been identified by LANL as one of the probes required to meet this grand challenge has never been demonstrated with high energy electrons. We propose to begin development of this technique with the electron beam available at FACET.

47 OTHER INSTRUMENTATION↗

FY2021 PAIN Portable Neutron Radiography Project October 1-15, 2020 Effort

At the start of FY2021, the PAIN portable neutron radiography project had approximately $26K of carryover funding from the FY2020 NA-22 DNN R&D PAIN budget that was used during the period October 1-15, 2020. During this period, the carryover funding was used to continue work on qualification of the Adelphi Technology DD108.2i neutron generator prior to returning for the DT upgrade, and further develop the neutron radiography modeling and simulation effort. This project is also being funded through NA-84 for FY2021.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Developing inductively driven diagnostic X-ray sources to enable transformative radiography and diffraction capabilities on Z

Penetrating X-rays are one of the most effective tools for diagnosing high energy density experiments, whether through radiographic imaging or X-ray diffraction. To expand the X-ray diagnostic capabilities at the 26-MA Z Pulsed Power Facility, we have developed a new diagnostic X-ray source called the inductively driven X-pinch (IDXP). This X-ray source is powered by a miniature transmission line that is inductively coupled to fringe magnetic fields in the final power feed. The transmission line redirects a small amount of Zs magnetic energy into a secondary cavity where 150+ kA of current is delivered to a hybrid X-pinch. In this report, we describe the multi-stage development of the IDXP concept through experiments both on Z and in a surrogate setup on the 1 MA Mykonos facility. Initial short-circuit experiments to verify power ow on Z are followed by short-circuit and X-ray source development experiments on Mykonos. The creation of a radiography-quality X-pinch hot spot is verified through a combination of X-ray diode traces, laser shadowgraphy, and source radiography. The success of the IDXP experiments on Mykonos has resulted in the design and fabrication of an IDXP for an upcoming Z experiment that will be the first-ever X-pinch fielded on Z. We have also pursued the development of two additional technologies. First, the extended convolute post (XCP) has been developed as an alternate method for powering diagnostic X-pinches on Z. This concept, which directly couples the current owing in one of the twelve Z convolute posts to an X-pinch, greatly increases the amount of available current relative to an IDXP (900 kA versus 150 kA). Initial short-circuit XCP experiments have demonstrated the efficacy of power ow in this geometry. The second technology pursued here is the inductively driven transmission line (IDTL) current monitor. These low-current IDTLs seek to measure the current in the final power feed with high fidelity. After three generations of development, IDTL current monitors frequently return cleaner current measurements than the standard B-dot sensors that are fielded on Z. This is especially true on high-inductance experiments where the harshest conditions are created in the nal power feed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-efficiency High-energy Photon Radiography Panels [Slides]

Demonstrate a developmental path towards production of efficient radiography panel for high energy radiography while keeping the production cost reasonable. Fulfill some needs identified in the research thrust GOR 2/K/b "Diagnostics systems".

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gantryless Associated-Particle Neutron Radiography

The present work reports on the development of techniques for in-field fast-neutron radiography measurements using the associated-particle imaging (API) method. The API method employs alpha-neutron coincidences from the d+t→α+n reaction to enable fast neutron transmission imaging with excellent contrast using a wide cone beam. However, for field radiography applications, the API method is burdened by the need for the relative positions of the source and detector to be known. Fortunately, these relative positions can be inferred from transmission data. The inferred positions also enable accurate stitching of multiple images into a composite image even when using a low-resolution detector panel and acquiring images having few overlapping pixels. The developed techniques address analysis of measurements where (1) the source and detector panel are separately hand positioned rather than held in registration by a gantry, (2) multiple detector panel positions within the “coincident cone” of tagged neutrons are required to piece together an image of an item of interest, and (3) normalization measurements that have identical source-detector positioning but without the inspected object are not possible. The present work will describe the system calibrations (including timing calibrations and neutron direction calibrations) necessary for subsequent analyses, the method of locating the detector in the coincident cone of neutrons with millimeter precision using the timing and directions of coincident neutrons, the method of calculating a normalization image for a given detector panel position, and the method used to project multiple images into a common image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Probe Radiography: For 2035 and Beyond

The Multi-Probe Radiography Project is investigating the use of multiple species of probe beams to provide more information from a radiography. Contextual radiographic, source, and measurements information is being provided through a series of four workshops at Los Alamos National Laboratory. The third workshop on Accelerator and Pulsed Power Technology is summarized in this report. The state of the large NNSA facilities such as Scorpius, DARHT, pRad, and Cygnus are presented. Future enhancements and innovative upgrades are also discussed.

43 PARTICLE ACCELERATORS↗

Z-Target Radiography Postprocessing With A Deep Convolution Neural Network

Analyzing X-ray radiographs is crucial for understanding target behavior in Inertial Confinement Fusion (ICF) and High Energy Density (HED) platforms. However, the density of Magneto Raleigh Taylor (MRT) bands and limitations of target materials often obscure relevant spike growth and density information. To address this issue, machine learning postprocessing techniques can be applied to remove darkened regions in radiography images. In this study, a novel method is presented for removing MRT darkened regions from z-target radiographs using a convolutional neural network (CNN). The CNN, consisting of six layers, treats the darkened regions as noise and employs a mixed loss function and end-to-end frameworks to suppress them while preserving sharpness. The six-layer architecture is designed to effectively learn features when provided with a larger volume of learning space. Each layer is optimized using a mixed loss function that combines a standard loss pixel approach with a multi-scaled structural similarity index loss, which considers luminance, contrast, and structure in local neighborhoods. This approach is particularly beneficial for capturing the stochastic structure of MRT limbs. Due to the limited availability of experimental data, training is conducted using synthetic target radiography from 3D Alegra simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Quantum Leap for Dynamic Radiography

Dynamic radiography techniques have been instrumental in advancing the National Nuclear Security Administration's (NNSA) mission since WWII. This paper explores the transformative potential of quantum information science (QIS) to revolutionize dynamic radiography through enhanced image processing, tomographic reconstruction, statistics and uncertainty quantification (UQ), and artificial intelligence integration. By leveraging quantum algorithms to extract previously inaccessible information from existing datasets, this interdisciplinary approach promises unprecedented insights at the intersection of dynamic imaging, artificial intelligence, and quantum information technologies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗