Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RETENTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Long-term performance of a UASB reactor treating acid mine drainage: effects of sulfate loading rate, hydraulic retention time, and COD/SO42- ratio

Acid mine drainage (AMD) is among the most serious threats to water and the typical alkali-based treatment costs are high. This study's main objective was the establishment of a highly efficient biological process using an upflow anaerobic sludge blanket (UASB) reactor to treat AMD based on a shorter hydraulic retention time (HRT) and lower organic matter input. The process was evaluated for a long-term operation (739days) in terms of the influence of HRT (14-24h), metal addition, sulfate loading rate (0.5-2.6gSO(4)(2-)l(-1)d(-1)), and the COD/SO42- ratio (0.67-1.0) using ethanol as the only electron donor at a pH of 4.0. Neutral effluent pH was achieved throughout the time apart from operational modifications. The reduction in HRT from 24 to 16h and an increase in the sulfate loading rate (SLR) up to 2.25gSO(4)(2-)l(-1)d(-1) improved the sulfate removal to (92.1 +/- 1.8)% with 80% chemical oxygen demand (COD) removal. However, the sulfate reduction was less than 80% when the HRT and SLR was changed to 14h and 2.6gSO(4)(2-)l(-1)d(-1), respectively. The oxidation of organic matter by sulfate reduction was greater than 50% regardless of the conditions imposed but the use of ethanol to treat AMD was more efficient when either the HRT was 16h (1.5gSO(4)(2-)l(-1)d(-1)) in the presence of Fe, Zn, and Cu or the HRT was 14h (2.6gSO(4)(2-)l(-1)d(-1)) but the COD/SO42- ratio was reduced to 0.67. The fully optimized conditions of the UASB reactor were set at an HRT of 16h, SLR of 1.5gSO(4)(2-)l(-1)d(-1), and a COD/SO42- ratio of 1.0.

Acid mine drainage↗

A pulsed field gradient and NMR imaging investigations of the water retention mechanism by cellulose ethers in mortars

The study presented in this paper is devoted to improve the knowledge on the influence of cellulose ethers (CE) on the freshly-mixed mortars water retention. Indeed, this crucial property is the most important imparted by these polysaccharides. One of the assumptions proposed to explain this phenomenon is that CE acts as diffusion barrier to the water. To test this hypothesis, the CE effect on the self-diffusion coefficient of water in solution and on the water mobility between two fresh cement pastes was studied by Nuclear Magnetic Resonance. CE does not significantly modify the water self-diffusion coefficient in CE solution or in admixed cement pastes. Moreover the interdiffusion imaging experiments demonstrated that the water diffusion at the paste/paste interface is not affected by the presence of cellulosic admixture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison between natural and accelerated carbonation (3% CO2): Impact on mineralogy, microstructure, water retention and cracking

The consequences of accelerated carbonation at 3% CO{sub 2} were compared with those of natural carbonation (0.04%). Cement pastes (CEM I and CEM V/A) as well as the three major constitutive phases (C-S-H of different C/S ratios, portlandite and ettringite) were used and changes in the mineralogy, microstructure, water retention and cracking were investigated. The main conclusion was that accelerated carbonation at 3% CO{sub 2} was representative of natural carbonation although it promoted the precipitation of metastable calcium carbonate (aragonite and vaterite) in place of calcite. The results also showed that the presence of aragonite and vaterite were characteristic of the carbonation of ettringite and C-S-H respectively.

36 MATERIALS SCIENCE↗

Toward a high-fidelity tritium transport modeling for retention and permeation experiments

We report Tritium Migration Analysis Program version 8 (TMAP8), the latest version of TMAP, was developed within the framework of the Multiphysics Object-Oriented Simulation Environment (MOOSE). Created at Idaho National Laboratory (INL), MOOSE is an open-source, dimension-agnostic, fully coupled, and fully implicit multiphysics platform featuring massively parallel computation capabilities. Using TMAP8, tritium transport in a divertor monoblock was analyzed to elucidate the effects of pulsed operation (up to fifty 1,600 s plasma discharge and cool-down cycles) on the tritium in-vessel inventory source term and ex-vessel release term (i.e., tritium retention and permeation) for safety analysis. With its built-in Message Passing Interface capability, TMAP8 can, in under 2 h, simulate tritium transport in three different layered materials (i.e., tungsten, copper, and copper-chromium-zirconium alloy) in 2D geometry, using a single device/computer with 10 cores. The MOOSE-based TMAP8 code can leverage other MOOSE tools developed under the Nuclear Energy Advanced Modeling and Simulation program to perform tritium and thermal transport in complex geometries and multiphysics environments. And via its massively parallel computation, MOOSE will enable the fusion pilot plant designers to conduct high-fidelity multiphysics modeling for the design of the divertor and blanket systems as well as for the safety analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Acute Urinary Retention After I-125 Prostate Brachytherapy in Relation to Dose in Different Regions of the Prostate

Purpose: To assess the influence of dose in different prostate regions, and the influence of anatomic variation on the risk of acute urinary retention (AUR) after I-125 prostate brachytherapy. Methods and Materials: In this case-control study, dosimetry and anatomy were compared between 50 patients with AUR (cases) and 50 patients without AUR (controls). Cases and controls were randomly selected from our database. The following structures were delineated on magnetic resonance imaging: prostate, urethra, peripheral zone, transitional zone, apex, base, midprostate, lower sphincter, and bladder neck. The dosimetric parameters analyzed were D{sub 10}, D{sub 50}, D{sub 90}, V{sub 100}, V{sub 150}, and V{sub 200}. The anatomic parameters analyzed were prostate protrusion into the bladder, bladder overlap, urethra angle, and urethra-bladder angle. The delineator was blinded to the patient's AUR status. Logistic regression analysis was used to investigate the association of these factors with AUR. Results: The dose delivered to different regions of the prostate was not significantly associated with the risk of AUR. Only dose to the bladder neck was significantly associated with AUR (odds ratio 1.13 per 10 Gy; 95% CI 1.02;1.26; p = 0.023). Mean bladder neck D{sub 90} was 65 Gy in AUR cases vs. 56 Gy in controls (p = 0.016), and mean bladder neck D{sub 10} was 128 Gy vs. 107 Gy, respectively (p = 0.018). Furthermore, on univariate analysis, a larger extent of both bladder overlap and of prostate protrusion were associated with a higher risk of AUR (odds ratio 1.16; 95% CI 1.04-1.28; p = 0.005, and odds ratio 1.83; 95% CI 1.37-2.45; p < 0.001, respectively). The mean extent of prostate protrusion was 3.5 mm in AUR cases vs. 1.0 mm in controls (p < 0.001). Odds ratios did not change substantially after adjustment for potential confounders. On multivariate analysis, the extent of prostate protrusion seemed to be a stronger risk factor for AUR than bladder overlap. Conclusion: The risk of AUR is not associated with dose delivered to different regions of the prostate. However, a higher dose to the bladder neck and a larger extent of prostate protrusion into the bladder are risk factors for the development of AUR after I-125 prostate brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pretreatment Nomogram to Predict the Risk of Acute Urinary Retention After I-125 Prostate Brachytherapy

Purpose: Acute urinary retention (AUR) after iodine-125 (I-125) prostate brachytherapy negatively influences long-term quality of life and therefore should be prevented. We aimed to develop a nomogram to preoperatively predict the risk of AUR. Methods: Using the preoperative data of 714 consecutive patients who underwent I-125 prostate brachytherapy between 2005 and 2008 at our department, we modeled the probability of AUR. Multivariate logistic regression analysis was used to assess the predictive ability of a set of pretreatment predictors and the additional value of a new risk factor (the extent of prostate protrusion into the bladder). The performance of the final model was assessed with calibration and discrimination measures. Results: Of the 714 patients, 57 patients (8.0%) developed AUR after implantation. Multivariate analysis showed that the combination of prostate volume, IPSS score, neoadjuvant hormonal treatment and the extent of prostate protrusion contribute to the prediction of AUR. The discriminative value (receiver operator characteristic area, ROC) of the basic model (including prostate volume, International Prostate Symptom Score, and neoadjuvant hormonal treatment) to predict the development of AUR was 0.70. The addition of prostate protrusion significantly increased the discriminative power of the model (ROC 0.82). Calibration of this final model was good. The nomogram showed that among patients with a low sum score (<18 points), the risk of AUR was only 0%-5%. However, in patients with a high sum score (>35 points), the risk of AUR was more than 20%. Conclusion: This nomogram is a useful tool for physicians to predict the risk of AUR after I-125 prostate brachytherapy. The nomogram can aid in individualized treatment decision-making and patient counseling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of nanochannel structure on helium-vacancy cluster evolution and helium retention

In the fusion reactors, plasma facing materials (PFMs) will be bombarded by large amounts of energetic particles, including helium (He) atoms. These metal-insoluble He atoms are prone to self-trapping or are trapped by vacancies, dislocation cores or grain boundaries, aggregating to form high concentration He bubbles which leads to serious degradation of the PFMs’ properties. Studying the initial stages of He-defect interactions becomes increasingly important because it not only helps us understand the formation mechanism of He bubbles but also provides insight to help design new irradiation-resistant PFMs. As such, in this work we used the positron annihilation Doppler broadening spectroscopy (DBS) and secondary ion mass spectrometry (SIMS) to explore the evolutions of the interactions between vacancy-type defects and He and the retention of He in the nanochannel W film irradiated with 190 keV He + ions to different fluences under different temperatures. It is found that the presence of a nanochannel structure accelerates the release of He from the film even at low irradiation fluences, and the release of He is significantly enhanced at higher fluences, thus inhibiting or delaying the formation of large He-vacancy clusters in the nanochannel W film. Both irradiation fluence and temperature have significant influence on the formation and evolution of He-vacancy clusters, and the evolution of these microstructure also causes hardness changes.

36 MATERIALS SCIENCE↗

Deuterium retention and blistering in tungsten foils

To investigate deuterium retention and the onset of blistering, deuterium was implanted in cold rolled tungsten foils at fluences ranging from 3x1020 to 3x1022 D/m2. Ion energies were 300 eV and 2000 eV in order to be below and above the tungsten theoretical damage energy threshold. While there were energy dependent phenomena, blistering occurs regardless of ion energy. Both plastically and elastically deformed blisters were observed, as manifest in before and after micrographs. The fraction of plastically deformed blisters did not saturate at the fluences used in these studies. However, the size of the largest blister that relaxes during TDS does saturate at ~7 µm. A simple conceptual model is presented that identifies that deuterium released from elastically deformed blisters appears at ~600 K in the thermal desorption spectra, which is consistent with large vacancy clusters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The retention time of inorganic mercury in the brain — A systematic review of the evidence

Reports from human case studies indicate a half-life for inorganic mercury in the brain in the order of years—contradicting older radioisotope studies that estimated half-lives in the order of weeks to months in duration. This study systematically reviews available evidence on the retention time of inorganic mercury in humans and primates to better understand this conflicting evidence. A broad search strategy was used to capture 16,539 abstracts on the Pubmed database. Abstracts were screened to include only study types containing relevant information. 131 studies of interest were identified. Only 1 primate study made a numeric estimate for the half-life of inorganic mercury (227–540 days). Eighteen human mercury poisoning cases were followed up long term including autopsy. Brain inorganic mercury concentrations at death were consistent with a half-life of several years or longer. 5 radionucleotide studies were found, one of which estimated head half-life (21 days). This estimate has sometimes been misinterpreted to be equivalent to brain half-life—which ignores several confounding factors including limited radioactive half-life and radioactive decay from surrounding tissues including circulating blood. No autopsy cohort study estimated a half-life for inorganic mercury, although some noted bioaccumulation of brain mercury with age. Modelling studies provided some extreme estimates (69 days vs 22 years). Estimates from modelling studies appear sensitive to model assumptions, however predications based on a long half-life (27.4 years) are consistent with autopsy findings. In summary, shorter estimates of half-life are not supported by evidence from animal studies, human case studies, or modelling studies based on appropriate assumptions. Evidence from such studies point to a half-life of inorganic mercury in human brains of several years to several decades. This finding carries important implications for pharmcokinetic modelling of mercury and potentially for the regulatory toxicology of mercury.

60 APPLIED LIFE SCIENCES↗

Chemometric Analysis of Gas Chromatography – Mass Spectrometry Data using Fast Retention Time Alignment via a Total Ion Current Shift Function

A critical comparison of methods for correcting severely retention time shifted gas chromatography-mass spectrometry (GC-MS) data is presented. The method reported herein is an adaptation to the Piecewise Alignment Algorithm to quickly align severely shifted one-dimensional (1D) total ion current (TIC) data, then applying these shifts to broadly align all mass channels throughout the separation, referred to as a TIC shift function (SF). The maximum shift varied from (-) 5 s in the beginning of the chromatographic separation to (+) 20 s toward the end of the separation, equivalent to a maximum shift of over 5 peak widths. Implementing the TIC shift function (TIC SF) prior to Fisher Ratio (F-Ratio) feature selection and then principal component analysis (PCA) was found to be a viable approach to classify complex chromatograms, that in this study were obtained from GC-MS separations of three gasoline samples serving as complex test mixtures, referred to as types C, M and S. The reported alignment algorithm via the TIC SF approach corrects for large dynamic shifting in the data as well as subtle peak-to-peak shifts. The benefits of the overall TIC SF alignment and feature selection approach were quantified using the degree-of-class separation (DCS) metric of the PCA scores plots using the type C and M samples, since they were the most similar, and thus the most challenging samples to properly classify. The DCS values showed an increase from an initial value of essentially zero for the unaligned GC-TIC data to a value of 7.9 following alignment; however, the DCS was unchanged by feature selection using F-Ratios for the GC-TIC data. The full mass spectral data provided an increase to a final DCS of 13.7 after alignment and two-dimensional (2D) F-Ratio feature selection.

02 PETROLEUM↗

Induction of galectin-1 by TGF-β1 accelerates fibrosis through enhancing nuclear retention of Smad2

Fibrosis is one of the most serious side effects in cancer patients undergoing radio-/ chemo-therapy, especially of the lung, pancreas or kidney. Based on our previous finding that galectin-1 (Gal-1) was significantly increased during radiation-induced lung fibrosis in areas of pulmonary fibrosis, we herein clarified the roles and action mechanisms of Gal-1 during fibrosis. Our results revealed that treatment with TGF-β1 induced the differentiation of fibroblast cell lines (NIH3T3 and IMR-90) to myofibroblasts, as evidenced by increased expression of the fibrotic markers smooth muscle actin-alpha (α-SMA), fibronectin, and collagen (Col-1). We also observed marked and time-dependent increases in the expression level and nuclear accumulation of Gal-1. The TGF-β1-induced increases in Gal-1, α-SMA and Col-1 were decreased by inhibitors of PI3-kinase and p38 MAPK, but not ERK. Gal-1 knockdown using shRNA decreased the phosphorylation and nuclear retention of Smad2, preventing the differentiation of fibroblasts. Gal-1 interacted with Smad2 and phosphorylated Smad2, which may accelerate fibrotic processes. In addition, up-regulation of Gal-1 expression was demonstrated in a bleomycin (BLM)-induced mouse model of lung fibrosis in vivo. Together, our results indicate that Gal-1 may promote the TGF-β1-induced differentiation of fibroblasts by sustaining nuclear localization of Smad2, and could be a potential target for the treatment of pulmonary fibrotic diseases. - Highlights: • Galectin-1 (Gal-1) promotes TGF-β-induced fibroblast differentiation via activation of PI3-kinase and p38 MAPK. • Gal-1 binds to Smad2 and phosphorylated Smad2. • GAl-1 may be a new therapeutic target for attenuating lung fibrotic process.

60 APPLIED LIFE SCIENCES↗

Evaluating Retention Index Score Assumptions to Refine GC–MS Metabolite Identification

As metabolomics grows into a high-throughput and high demand research field, current metrics for the identification of small molecules in gas chromatography–mass spectrometry (GC–MS) still require manual verification. Though steps have been taken to improve scoring metrics by combining spectral similarity (SS) and retention index (RI), the problem persists. A large body of literature has analyzed and refined SS scores, but few studies have explicitly studied improvements to RI scores. Here, in this study, we examined whether uninvestigated assumptions of the RI score are valid and propose ways to improve them. Query RIs were matched to library RI with a generous window of ±35 to avoid unintentional removal of valid compound identifications. Each match was manually verified as a true positive (TP), true negative, or unknown. Metabolites with at least 30 TP identifications were included in downstream analyses, resulting in a total of 87 metabolites from samples of varying complexity and type (e.g., amino acid mixtures, human urine, fungal species, and so on.). Our results showed that the RI score assumptions of normality, consistent variance across metabolites, and a mean error centered at 0 are often violated. We demonstrated through a cross-validation analysis that modifying these underlying assumptions according to empirical metabolite-specific distributions improved the TP and negative rankings. Further, we statistically determined the minimum number of samples required to estimate distributional parameters for scoring metrics. Overall, this work proposes a robust statistical pipeline to reduce the time bottleneck of metabolite identification by improving RI scores and thus minimize the effort to complete manual verification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cu Doping Increases Capacity Retention in LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622) by Altering the Potential of the Ni-Based Redox Couple and Inhibiting Particle Pulverization

To discern the influence of Cu 2+ as a dopant on both the structural and electrochemical characteristics of LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622), Cu 2+ (aq) was added to the coprecipitation synthesis from the constituent ions. At 5 mol % Cu 2+ , a single-phase Cu-NMC product results, evidenced by an increase in d-spacing along the [003] and [104] directions and a slight increase in the crystal volume of the R–3m hexagonal (rock-salt superstructure) lattice. XRD data and high-resolution TEM imaging support Cu 2+ doping primarily on the transition metal 3b Wyckoff sites. Here, galvanostatic cycling of Cu-NMC shows a reversible gravimetric capacity of 102 mAh/g compared to 136 mAh/g for undoped NMC. Despite the lower capacity, the discharge capacity retention of Cu-NMC is 89% after 100 cycles compared to only 70% for NMC. XPS analysis reveals that this lower capacity is due to an increase in the concentration of Ni 3+ ions at the surface, while XRD data collected at the top and bottom of charge show a smaller decrease in crystalline domain size for Cu-NMC (40.5% decrease) compared to NMC (74.7% decrease), translating to pulverization of the secondary particles.

25 ENERGY STORAGE↗

Synchrotron X-ray-Induced Photoreduction of Ferric Myoglobin Nitrite Crystals Gives the Ferrous Derivative with Retention of the O-bonded Nitrite Ligand

Exposure of a single crystal of the nitrite adduct of ferric myoglobin (Mb) at 100 K to high-intensity synchrotron X-ray radiation resulted in changes in the UV-vis spectrum that can be attributed to reduction of the ferric compound to the ferrous derivative. We employed correlated single-crystal spectroscopy with crystallography to further characterize this photoproduct. The 1.55 {angstrom} resolution crystal structure of the photoproduct reveals retention of the O-binding mode for binding of nitrite to the iron center. The data are consistent with cryogenic generation and trapping, at 100 K, of a ferrous d{sup 6} Mb{sup II}(ONO)* complex by photoreduction of the ferric precursor crystals using high-intensity X-ray radiation.

59 BASIC BIOLOGICAL SCIENCES↗

Effect of plastic deformation on deuterium retention and release in tungsten

The effect of severe plastic deformation on the deuterium retention in tungsten exposed to high-flux low-energy plasma (flux ∼ 10{sup 24 }D/m{sup 2}/s, energy ∼ 50 eV, and fluence up to 3 × 10{sup 26 }D/m{sup 2}) at the plasma generator Pilot-PSI was studied by thermal desorption spectroscopy and scanning electron microscopy. The desorption spectra in both reference and plastically deformed samples were deconvolved into three contributions attributed to the detrapping from dislocations, deuterium-vacancy clusters, and pores, respectively. The plastically induced deformation, resulting in high dislocation density, does not change the positions of the three peaks, but alters their amplitudes as compared to the reference material. The appearance of blisters detected by scanning electron microscopy and the desorption peak attributed to the release from pores (i.e., deuterium bubbles) were suppressed in the plastically deformed samples but only up to a certain fluence. Beyond 5 × 10{sup 25 }D/m{sup 2}, the release from the bubbles in the deformed material is essentially higher than in the reference material. Based on the presented results, we suggest that a dense dislocation network increases the incubation dose needed for the appearance of blisters, associated with deuterium bubbles, by offering numerous nucleation sites for deuterium clusters eventually transforming into deuterium-vacancy clusters by punching out jogs on dislocation lines.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Conditions for circular polarisation retention in highly scattering media

We analyse conditions for circular polarisation retention in multiple scattering of light by disordered media. The effect of circular polarisation memory is shown to appear when the depolarisation cross section is much smaller than the transport cross section of elastic scattering. This situation occurs in media composed of large (compared to the wavelength of light) weakly refracting scatterers and of resonant Mie particles. Absorption in the medium is shown to result in a significant increase in the depolarisation length. (light scattering)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Trapping, retention and laser cooling of Th{sup 3+} ions in a multisection linear quadrupole trap

A multisection linear quadrupole trap for Th{sup 3+} ions is described. Multiply charged ions are obtained by the laser ablation method. The possibility of trapping and retention of ∼10{sup 3} ions is demonstrated in macroscopic time scales of ∼30 s. Specific features of cooling Th{sup 3+} ions on the electron transitions with wavelengths of 1088, 690 and 984 nm in Th{sup 3+} ion are discussed; a principal scheme of a setup for laser cooling is presented. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of Incision Location on Transmitter Loss, Healing, Survival, Growth, and Suture Retention of Juvenile Chinook Salmon

Fisheries research involving surgical implantation of transmitters necessitates the use of methods that minimize transmitter loss and fish mortality and optimize healing of the incision. We evaluated the effects of three incision locations on transmitter loss, healing, survival, growth, and suture retention in juvenile Chinook salmon Oncorhynchus tshawytscha. The three incision locations were (1) on the linea alba (LA incision), (2) adjacent and parallel to the LA (muscle-cutting [MC] incision), and (3) extending from the LA towards the dorsum at a 45° angle, between the parallel lines of myomeres (muscle-sparing [MS] incision). A Juvenile Salmon Acoustic Telemetry System acoustic transmitter (0.44 g in air) and a passive integrated transponder tag (0.10 g in air) were implanted into each fish (total N = 936 fish). The fish were held at 12°C or 20°C and were examined weekly for 98 d. The progression of healing among incision locations and the variability in transmitter loss made it difficult to identify one incision location as the best choice. The LA incisions had a much smaller wound extent (area of visible subepidermal tissue) than MC and MS incisions during the first 28 d of the study. In both temperature treatments, apposition of incisions through day 14 was better for LA incisions than for MC and MS incisions. However, MC and MS incisions were less likely than LA incisions to reopen over time and thus were less likely to allow transmitter loss through the incision.

54 ENVIRONMENTAL SCIENCES↗