Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFLECTOMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environment

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion sensor was also tested in soil at > 1 foot depth. Fe-coated OFS was loaded into a Draka cable, which provides mechanical support during fiber deployment and installation into either acidified soil, top-soil, or sandy soil (50/50).

corrosion↗

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environments

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion was measurable out to > 100 meters (m), which is a significant improvement over our previous work, which showed corrosion sensing at < 10 m. The corrosion sensor was also tested in soil at > 1 foot depth.

corrosion↗

Optical Fiber Sensor Instrumentation for Slagging Coal Gasifiers

Coal gasifier is one of the most promising solutions for clean fossil energy. Refractory thickness monitoring and online real-time temperature measurement is needed for improved reliability and advanced process control for current and future generation power plants. The objective of this program is to design and implement an optical fiber based sensing system that could potentially be used to monitor refractory wall thickness and temperature inside a coal gasifier. For the thickness monitoring, the system should be able to operate at temperatures up to 1000 C. For this temperature range, silica fiber can still work so it is chosen for the sensor design. The measurement is based on a photon counting optical time domain reflectometer. A narrow light pulse is launched into a silica fiber which could be embedded into the gasifier refractory wall, and is partially reflected by the far end of the fiber. The time of flight of the light pulse in the fiber then gives an indication of the position of the fiber end, which is a function of the wall thickness when the fiber is embedded. Results obtained show a measurement accuracy of {+-}2cm in environment of 1000 C with a saw cut fiber end. When the fiber end is corroded by sodium carbide at 900 C, the accuracy is {+-}3cm. For the temperature measurement, a single crystal sapphire fiber sensor is designed. The sapphire fiber guides the broadband light from a light emitting diode to a sapphire wafer functioning as a Fabry-Perot interferometer and the wafer optical thickness is a function of temperature. The returned optical signal is then demodulated by multimode fiber based whitelight interferometry. The system was tested up to 1500 C with a measurement accuracy of {+-}10 C for the entire measurement range.

01 COAL, LIGNITE, AND PEAT↗

Modeling Fast Ion Transport in TAE Avalanches in NSTX

Experiments on the National Spherical Torus Experiment [M. Ono, et al., Nucl. Fusion 40 (2000) 557 ] have found strong bursts of Toroidal Alfven Eigenmode (TAE) activity correlated with abrupt drops in the neutron rate. A fairly complete data set offers the opportunity to benchmark the NOVA [C. Z. Cheng, Phys. Reports 211, 1-51 (1992)] and ORBIT [R. B. White and M. S. Chance, Phys. Fluids 27, 2455 (1984)] codes in the low aspect ratio tokamak (ST) geometry. The internal structure of TAE were modeled with NOVA and good agreement is found with measurements made with an array of five fixed-frequency reflectometers. The fast-ion transport resulting from these bursts of multiple TAE were then modeled with the ORBIT code. The simulations are reasonably consistent with the observed drop in neutron rate. While these results represent our best attempts to find agreement, we believe that further refinements in both the simulation of the TAE structure and in the modeling of the fast ion transport are needed. Benchmarking stability codes against present experiments is an important step in developing the predictive capability needed to plan future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High Speed, Localized Multi-Point Strain Measurements on a Containment Vessel at 1.7 MHz Using Swept-Wavelength Laser-Interrogated Fiber Bragg Gratings

Dynamic elastic strain in ~1.8 and 1.0 m diameter containment vessels containing a high explosive detonation was measured using an array of fiber Bragg gratings. The all-optical method, called real-time localized strain measurement, recorded the strain for 10 ms after detonation with additional measurements being sequentially made at a rate of 1.7 MHz. A swept wavelength laser source provided the repetition rate necessary for such high-speed measurements while also providing enough signal strength and bandwidth to simultaneously measure 8 or more unique points on the vessel’s surface. The data presented here arethen compared with additional diagnostics consisting of a fast spectral interferometer and an optical backscatter reflectometer to show a comparison between the local and global changes in the vessel strain, both dynamically and statically to further characterize the performance of the localized strain measurement. The results are also compared with electrical resistive strain gauges and finite element analysis simulations.

47 OTHER INSTRUMENTATION↗

High resolution density pedestal measurements during edge localized modes by short-pulse reflectometry in the TCV tokamak

This publication presents high spatio-temporal resolution (mm/μs) density profile measurements of the pedestal top during type I, III, and small edge localized mode (ELM) H-mode plasmas in the Tokamak à Configuration Variable (TCV). These measurements were performed using a novel short-pulse reflectometer. Average inter-ELM density profiles are obtained via conditional averaging using the Dα trace as ELM indicator. Changes to the pedestal density profile gradients prior to type-III ELMs reveal unique pedestal dynamics leading to the ELM crash which can provide important experimental data for validation of non-linear MHD ELM simulations. The small-ELM scenario is found to feature a ∼25-35 kHz quasi-coherent density fluctuation near the separatrix rho_psi ∼0.993-1.05 not observed during a similar type-I ELM discharge. This oscillation is also found in low-field-side magnetic pick- up probes displaying a ballooning character and n=+1 toroidal mode number. This oscillation could help explain the markedly different pedestal dynamics observed in the small-ELM regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chaotic edge density fluctuations in the Alcator C-Mod tokamak

Analysis of the time series obtained with the O-Mode reflectometer [Rhodes et al., 1997 Plasma Phys. Controlled Fusion 40, 493–510 (1998)] and the gas puff imaging [Cziegler et al., Phys. Plasmas 17(5), 056120 (2010)] systems on the Alcator C-Mod tokamak reveals that the turbulent edge density fluctuations are chaotic. Supporting evidence for this conclusion includes the observation of exponential power spectra (which is associated with Lorentzian-shaped pulses in the time series), the population of the corresponding Bandt-Pompe probability distributions [Bandt and Pompe, Phys. Rev. Lett. 88, 174102 (2002)], and the location of the signal on the complexity-entropy plane (C-H plane) [Rosso et al., Phys. Rev. Lett. 99, 154102 (2007)]. The classification of edge turbulence as chaotic opens the door for further work to understand the underlying process and the impact on turbulent transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrostatic-probe measurements of plasma parameters for two reentry flight experiments at 25000 feet per second

Unique plasma diagnostic measurements at high altitudes from two geometrically similar blunt body reentry spacecraft using electrostatic probe rakes are presented. The probes measured the positive ion density profiles (shape and magnitude) during the two flights. The probe measurements were made at eight discrete points (1 cm to 7 cm) from the vehicle surface in the aft flow field of the spacecraft over the altitude range of 85.3 to 53.3 km (280,000 to 175,000 ft) with measured densities of 10 to the 8th power to 10 to the 12th power electrons/cu cm, respectively. Maximum reentry velocity for each spacecraft was approximately 7620 meters/second (25,000 ft/sec). In the first flight experiment, water was periodically injected into a flow field which was contaminated by ablation products from the spacecraft nose region. The nonablative nose of the second spacecraft thereby minimized flow field contamination. Comparisons of the probe measured density profiles with theoretical calculations are presented with discussion as to the probable cause of significant disagreement. Also discussed are the correlation of probe measurements with vehicle angle of attack motions and the good high altitude agreement between electron densities inferred from the probe measurements, VHF antenna measurements, and microwave reflectometer diagnostic measurements.

Jones, W. L., Jr.↗

Material injection alleviation and plasma diagnostic measurements during the RAM C-III flight.

The results of a material injection RF blackout alleviation experiment and of plasma diagnostic measurements using electrostatic probes and an S-band reflectometer in a 25,000 ft/sec reentry flight are presented. Significant alleviation of RF blackout is observed at altitudes of from 270,000 feet to 120,000 feet due to injection of water and Freon E-3 on VHF, S-band, C-band, and X-band frequencies. Electrostatic probe data, attenuation data, and S-band diagnostic data show consistent plasma results. The relative effectiveness of water and Freon E-3 is discussed.

Schroeder, L. C.↗