Measurement of parity-violating γ -ray asymmetry in the capture of polarized cold neutrons on protons
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Discussions are presented of the associations between cosmic gamma ray bursts and transient X-ray sources, and the release of gravitational binding energy during the formation of neutron stars. The model for studying the associations is described along with the release of neutrinos during the collapse of white dwarfs.
Alkali antimonides have a long history as visible-light-sensitive photocathodes. This work focuses on the process of fabrication of the bi-alkali photocathodes, K{sub 2}CsSb. In-situ synchrotron x-ray diffraction and photoresponse measurements were used to monitor phase evolution during sequential photocathode growth mode on Si(100) substrates. The amorphous-to-crystalline transition for the initial antimony layer was observed at a film thickness of 40 Å . The antimony crystalline structure dissolved upon potassium deposition, eventually recrystallizing upon further deposition into K-Sb crystalline modifications. This transition, as well as the conversion of potassium antimonide to K{sub 2}CsSb upon cesium deposition, is correlated with changes in the quantum efficiency.
The Large Area Telescope (LAT) on board the Fermi Gamma-ray Space Telescope discovered a rapid ({approx}5 days duration), high-energy (E > 100 MeV) gamma-ray outburst from a source identified with the blazar PKS 1502+106 (OR 103, S3 1502+10, z = 1.839) starting on 2008 August 5 ({approx}23 UTC, MJD 54683.95), and followed by bright and variable flux over the next few months. Results on the gamma-ray localization and identification, as well as spectral and temporal behavior during the first months of the Fermi all-sky survey, are reported here in conjunction with a multiwaveband characterization as a result of one of the first Fermi multifrequency campaigns. The campaign included a Swift ToO (followed up by a 16 day observation on August 7-22, MJD 54685-54700), VLBA (within the MOJAVE program), Owens Valley Radio Observatory (OVRO) 40 m, Effelsberg-100 m, Metsaehovi-14 m, RATAN-600, and Kanata-Hiroshima radio/optical observations. Results from the analysis of archival observations by {integral}, XMM-Newton, and Spitzer space telescopes are reported for a more complete picture of this new gamma-ray blazar. PKS 1502+106 is a sub-GeV peaked, powerful flat spectrum radio quasar (luminosity at E > 100 MeV, L{sub g}amma, is about 1.1 x 10{sup 49} erg s{sup -1}, and black hole mass likely close to 10{sup 9} M{sub sun}), exhibiting marked gamma-ray bolometric dominance, in particular during the asymmetric outburst (L{sub g}amma/L{sub opt} {approx} 100, and 5 day averaged flux F{sub E>100MeV} = 2.91 +- 1.4 x 10{sup -6} ph cm{sup -2} s{sup -1}), which was characterized by a factor greater than 3 of flux increase in less than 12 hr. The outburst was observed simultaneously from optical to X-ray bands (F{sub 0.3-10{sub keV}} = 2.18{sup +0.15}{sub -0.12} x 10{sup -12} erg cm{sup -2} s{sup -1}, and hard photon index {approx}1.5, similar to past values) with a flux increase of less than 1 order of magnitude with respect to past observations, and was likely controlled by Comptonization of external-jet photons produced in the broad-line region (BLR) in the gamma-ray band. No evidence of a possible blue bump signature was observed in the optical-UV continuum spectrum, while some hints for a possible 4 day time lag with respect to the gamma-ray flare were found. Nonetheless, the properties of PKS 1502+106 and the strict optical/UV, X-, and gamma-ray cross-correlations suggest the contribution of the synchrotron self-Compton (SSC), in-jet, process should dominate from radio to X-rays. This mechanism may also be responsible for the consistent gamma-ray variability observed by the LAT on longer timescales, after the ignition of activity at these energies provided by the BLR-dissipated outburst. Modulations and subsequent minor, rapid flare events were detected, with a general fluctuation mode between pink-noise and a random-walk. The averaged gamma-ray spectrum showed a deviation from a simple power law, and can be described by a log-parabola curved model peaking around 0.4-0.5 GeV. The maximum energy of photons detected from the source in the first four months of LAT observations was 15.8 GeV, with no significant consequences on extragalactic background light predictions. A possible radio counterpart of the gamma-ray outburst can be assumed only if a delay of more than three months is considered on the basis of opacity effects at cm and longer wavelengths. The rotation of the electric vector position angle observed by VLBA from 2007 to 2008 could represent a slow field ordering and alignment with respect to the jet axis, likely a precursor feature of the ejection of a superluminal radio knot and the high-energy outburst. This observing campaign provides more insight into the connection between MeV-GeV flares and the moving, polarized structures observed by the VLBI.
Abstract not provided
N/A
Time resolved, in-situ, energy dispersive x-ray diffraction was performed in an electrolysis cell during electrochemical loading of palladium foil cathodes with hydrogen and deuterium. Concentrations of H:Pd (D:Pd) up to 1:1 in 0.1 M LiOH (LiOD) in H{sub 2}O (D{sub 2}O) electrolyte were obtained, as determined by both the Pd lattice parameter and cathode resistivity. In addition, some indications on the kinetics of loading and deloading of hydrogen from the Pd surface were obtained. The alpha-beta phase transformations were clearly delineated but no new phases at high concentration were determined.
Double-perovskite oxide Sr{sub 2}MgTeO{sub 6} has been synthetized, and its crystal structure was probed by the technique of X-ray diffraction at room temperature. The structure is monoclinic, space group I2/m. Temperature-induced phase transitions in this compound were investigated by Raman spectroscopy up to 550 °C. Two low-wavenumber modes corresponding to external lattice vibrations merge at temperature of around 100 °C, indicating a phase transition from the monoclinic (I2/m) to the tetragonal (I4/m) structure. At 300 °C, changes in the slopes of temperature dependencies of external and O–Te–O bending modes are detected and interpreted as a second phase transition from the tetragonal (I4/m) to the cubic (Fm-3m) structure.
Abstract not provided
The identification of low-energy counterparts for {gamma}-ray sources is one of the biggest challenges in modern {gamma}-ray astronomy. Recently, we developed and successfully applied a new association method to recognize {gamma}-ray blazar candidates that could be possible counterparts for the unidentified {gamma}-ray sources above 100 MeV in the second Fermi Large Area Telescope Catalog. This method is based on the infrared colors of the recent Wide-Field Infrared Survey Explorer (WISE) all-sky survey. In this Letter, we applied our new association method to the case of unidentified INTEGRAL sources (UISs) listed in the fourth soft gamma-ray source catalog. Only 86 UISs out of the 113 can be analyzed due to the sky coverage of the WISE Preliminary Data Release. Among these 86 UISs, we found that 18 appear to have a {gamma}-ray blazar candidate within their positional error region. Finally, we analyzed Swift archival data available for 10 out of these 18 {gamma}-ray blazar candidates, and we found that 7 out of 10 are clearly detected in soft X-rays and/or in the optical-ultraviolet band. We cannot confirm the associations between the UISs and the selected {gamma}-ray blazar candidates due to the discrepancies between the INTEGRAL and the soft X-ray spectra. However, the discovery of the soft X-ray counterparts for the selected {gamma}-ray blazar candidates adds an important clue to help us understand their origin and to confirm their blazar nature.
Purpose: To assess whether X-ray acoustic computed tomography (XACT) is more sensitive to X-ray absorption than that of the conventional X-ray imaging. Methods: First, a theoretical model was built to analyze the X-ray absorption sensitivity of XACT imaging and conventional X-ray imaging. Second, an XACT imaging system was developed to evaluate the X-ray induced acoustic signal generation as well as the sensitivity improvement over transmission x-ray imaging. Ultra-short x-ray pulses (60-nanosecond) were generated from an X-ray source operated at the energy of 150 kVp with a 10-Hz repetition rate. The X-ray pulse was synchronized with the acoustic detection via a x-ray scintillation triggering to acquire the X-ray induced acoustic signal. Results: Theoretical analysis shows that X-ray induced acoustic signal is sensitive only to the X-ray absorption, while completely insensitive to out the X-ray scattering and fluorescence. XACT has reduced background and increased contrast-to-noise ratio, and therefore has increased sensitivity compared to transmission x-ray imaging. For a 50-μm size, gadolinium insertion in tissue exposed to 40 keV X-rays; the sensitivity of XACT imaging is about 28.9 times higher than that of conventional X-ray imaging. Conclusion: X-ray acoustic computer tomography (XACT) as a new imaging modality combines X-ray absorption contrast and high ultrasonic resolution in a single modality. It is feasible to improve the imaging sensitivity with XACT imaging compared with conventional X-ray imaging. Taking advantage of the high ultrasonic resolution, it is possible to perform 3-D imaging with a single x-ray pulse with arrays of transducers without any mechanical motion of the imaging system. This single-shot capability offers the potential of reducing radiation dose by a factor of 1000, and imaging 100 times faster when compared to the conventional X-ray CT, and thus revolutionizing x-ray imaging applications in medicine and biology. The authors gratefully acknowledge the Department of Defense Prostate Cancer Research Programs W81XWH-13-1-0481 (LX), the National Institutes of Health 1R01 CA133474 and 1R21 A153587, and SRFDP (20124407120012) for funding.
Diagnostic use of single-pulse x-ray diffraction (XRD) at pulsed power facilities can be challenging due to factors such as the high flux and brightness requirements for diffraction and the geometric constraints of experimental platforms. By necessity, the x-ray source is usually positioned very close, within a few inches of the sample. On dynamic compression platforms, this puts the x-ray source in the debris field. We coupled x-ray polycapillary optics to a single-shot needle-and-washer x-ray diode source using a laser-based alignment scheme to obtain high-quality x-ray diffraction using a single 16 ns x-ray pulse with the source >1 m from the sample. Additionally, the system was tested on a Mo sample in reflection geometry using 17 keV x-rays from a Mo anode. We also identified an anode conditioning effect that increased the x-ray intensity by 180%. Quantitative measurements of the x-ray focal spot produced by the polycapillary yielded a total x-ray flux on the sample of 3.3 ± 0.5 × 10 7 molybdenum Kα photons.
We report the probable identification of the X-ray counterpart to the {gamma}-ray pulsar PSR J2021+4026 using imaging with the Chandra X-ray Observatory Advanced CCD Imaging Spectrometer and timing analysis with the Fermi satellite. Given the statistical and systematic errors, the positions determined by both satellites are coincident. The X-ray source position is R.A. 20{sup h}21{sup m}30.{sup s}733, decl. +40 Degree-Sign 26'46.''04 (J2000) with an estimated uncertainty of 1.''3 combined statistical and systematic error. Moreover, both the X-ray to {gamma}-ray and the X-ray to optical flux ratios are sensible assuming a neutron star origin for the X-ray flux. The X-ray source has no cataloged infrared-to-visible counterpart and, through new observations, we set upper limits to its optical emission of i' > 23.0 mag and r' > 25.2 mag. The source exhibits an X-ray spectrum with most likely both a power law and a thermal component. We also report on the X-ray and visible light properties of the 43 other sources detected in our Chandra observation.
We have analyzed the new deep XMM-Newton and Chandra observations of the energetic, radio-quiet pulsar J1813–1246. The X-ray spectrum is nonthermal, very hard, and absorbed. Based on spectral considerations, we propose that J1813 is located at a distance further than 2.5 kpc. J1813 is highly pulsed in the X-ray domain, with a light curve characterized by two sharp, asymmetrical peaks, separated by 0.5 in phase. We detected no significant X-ray spectral changes during the pulsar phase. We extended the available Fermi ephemeris to five years. We found two glitches. The γ-ray light curve is characterized by two peaks, separated by 0.5 in phase, with a bridge in between and no off-pulse emission. The spectrum shows clear evolution in phase, being softer at the peaks and hardening toward the bridge. Surprisingly, both X-ray peaks lag behind the γ-ray ones by a quarter of phase. We found a hint of detection in the 30-500 keV band with INTEGRAL, which is consistent with the extrapolation of both the soft X-ray and γ-ray emission of J1813. The unique X-ray and γ-ray phasing suggests a singular emission geometry. We discuss some possibilities within the current pulsar emission models. Finally, we develop an alternative geometrical model where the X-ray emission comes from polar cap pair cascades.
National Security Technologies (NSTec) has developed calibration procedures for X-ray imaging systems using NIST traceable sources. The X-ray sources that are used for calibration are both diode type and diode/fluorescer combinations. Calibrating the X-ray detectors is the key to accurate calibration of the X-ray sources. Both energy dispersive detectors and photodiodes measuring total flux were used. We have developed calibration techniques for the detectors using radioactive sources that are traceable to the National Institute of Standards and Technology (NIST). The German synchrotron at Physikalische Technische Bundestalt (PTB) is used to calibrate silicon photodiodes over the energy range from 50 eV to 60 keV. The measurements on X-ray cameras made using the NSTec X-ray sources have included the quantum efficiency averaged over all pixels, the camera counts per photon per pixel, and response variation across the sensor. The instrumentation required to accomplish the calibrations is described. X-ray energies ranged from 720 eV to 22.7 keV. The X-ray sources produce narrow energy bands, allowing us to determine the properties as a function of X-ray energy. The calibrations were done for several types of imaging devices. There were back illuminated and front illuminated CCD (charge coupled device) sensors, and a CID (charge injection device) type camera. The CCD and CID camera types differ significantly in some of their properties that affect the accuracy of X-ray intensity measurements. All cameras discussed here are silicon based. The measurements of quantum efficiency variation with X-ray energy are compared to models for the sensor structure. Cameras that are not back-thinned are compared to those that are.