Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

SU-F-J-202: Secondary Radiation Measurements for Charged Particle Therapy Monitoring: Fragmentation of Therapeutic He, C and O Ion Beams Impinging On a PMMA Target

Purpose: In Charged Particle Therapy (CPT), besides protons, there has been recently a growing interest in 4He, 12C and 16O beams. The secondary radiation produced in the interaction of those beams with a patient could be potentially used for on-line monitoring of range uncertainties in order to fully exploit the advantages of those light ions resulting from increased Radio Biological Effectiveness, reduced multiple scattering and Oxygen Enhancement Ratio. The study and precise characterization of secondary radiation (beta+, prompt gamma, charged fragments) is the cornerstone of any R&D activity aiming for online monitoring development and purpose of the analysis presented here. Methods: We present the measurements of the secondary radiation generated by He, C and O beams impinging on a beam stopping PMMA target. The data has been collected at the Heidelberg Ionbeam Therapy center (HIT), where several millions of collisions were recorded at different energies, relevant for therapeutical applications. Results: The experimental setup, as well as the analysis strategies will be reviewed. The detected particle fluxes as a function of the primary beam energy and the emission angle with respect to the beam direction will be presented and compared to the results of other available measurements. In addition, the energy spectra and emission shapes of charged secondary particles will be shown and discussed in the context of the primary beam range monitoring technique that is being developed by the ARPG collaboration, within the INSIDE project funded by the Italian research ministry. The implications for dose monitoring applications will be discussed, in the context of the current (or planned) state-of- the-art detector solutions. Conclusion: The characterization of the radiation produced by 12C, 4He and 16O beams fully supports the feasibility of on-line range monitoring in the clinical practice of CPT by means of secondary particles detection.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ionizing radiation measurements on LDEF: A0015 Free flyer biostack experiment

This report covers the analysis of passive radiation detectors flown as part of the A0015 Free Flyer Biostack on LDEF (Long Duration Exposure Facility). LET (linear energy transfer) spectra and track density measurements were made with CR-39 and Polycarbonate plastic nuclear track detectors. Measurements of total absorbed dose were carried out using Thermoluminescent Detectors. Thermal and resonance neutron dose equivalents were measured with LiF/CR-39 detectors. High energy neutron and proton dose equivalents were measured with fission foil/CR-39 detectors.

Benton, E. V.↗

Atmospheric Radiation Measurement Program: Accomplishments from the Science Program and User Facility (2008)

The Earth’s surface temperature is determined by the balance between incoming solar radiation and thermal (or infrared) radiation emitted by the Earth back to space. Changes in atmospheric composition, including greenhouse gases, clouds, and aerosols, can alter this balance and produce significant climate change. Global climate models (GCMs) are the primary tool for quantifying future climate change; however, there remain significant uncertainties in the GCM treatment of clouds, aerosols, and their effects on the Earth’s energy balance. The ARM Climate Research Facility has become the standard for ground-based climate research observations while ARM scientists lead the world in research related to the interactions of clouds and radiation. Highlights in this summary illustrate how the ARM Program has achieved specific advances in: measurements of key components of the Earth’s climate system, radiation calculations in climate models, and the representation of clouds in climate models. As this and future work is implemented in more climate models, ARM research will help to reduce uncertainties in climate predictions.

54 ENVIRONMENTAL SCIENCES↗

Determination of neutral beam energy fractions from collisional radiative measurements on DIII-D

Neutral beams based on positive ion source technology are a key component of contemporary fusion research. An accurate assessment of the injected beam species mix is important for determining the actual plasma heating and momentum input as well as proper interpretation of beam-based diagnostics. On DIII-D, the main ion charge-exchange spectroscopy system is used to extract well-resolved intensity ratios of the Doppler-shifted D{sub {alpha}} emission from the full, half, and third energy beam components for a variety of beam operational parameters. In conjunction with accurate collisional-radiative modeling, these measurements indicate the assumed species mix and power fractions can vary significantly and should be regularly monitored and updated for the most accurate interpretation of plasma performance. In addition, if stable active control of the power fractions can be achieved through appropriate source tuning, the resulting control over the deposition profile can serve as an additional experimental knob for advanced tokamak studies, e.g., varying the off axis beam current drive without altering the beam trajectory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accuracy of earth albedo estimates from wide-angle radiation measurements

The instantaneous resolution and accuracy that can be expected from two inversion techniques to be used in the Earth Radiation Budget Experiment (ERBE) are examined. It is shown that measurement errors are magnified by the numerical filter and that this magnification is a function of the magnitude of the inversion factor. By using singular value decomposition, these magnitudes can be reduced to improve the estimates. A simulation of the estimation process using an albedo field derived from scanning radiometer data shows that retaining 6 of the 13 singular values gives the best results. If there are no bidirectional model errors the medium-field-of-view data give the best estimates. However, when bidirectional model errors are considered, the wide-field-of-view measurements give better estimates since they are less sensitive to these errors.

Green, R. N.↗

Development of an experiment for visible radiation measurements from a satellite

The inversion problem, I.E., determining the atmospheric turbidity from polarimetry of radiation emerging from the earth's atmosphere, is presented. A major theoretical advance was made by finding a successful approximation for the forward peak scattering of aerosols together with a simplified characterization of particle size distributions. An engineering model of a multibarreled photopolarimeter suitable for operation from a satellite was evaluated in laboratory and high altitude jet aircraft tests. Comparison of the data from flights over the Mexican desert with theoretical curves for a Rayleigh atmosphere with negligible turbidity is in agreement.

Sekera, Z.↗

Parameter estimation applied to Nimbus 6 wide-angle longwave radiation measurements

A parameter estimation technique was used to analyze the August 1975 Nimbus 6 Earth radiation budget data to demonstrate the concept of deconvolution. The longwave radiation field at the top of the atmosphere is defined from satellite data by a fifth degree and fifth order spherical harmonic representation. The variations of the major features of the radiation field are defined by analyzing the data separately for each two-day duty cycle. A table of coefficient values for each spherical harmonic representation is given along with global mean, gradients, degree variances, and contour plots. In addition, the entire data set is analyzed to define the monthly average radiation field.

Green, R. N.↗

A Survey of Radiation Measurements Made Aboard Russian Spacecraft in Low-Earth Orbit

The accurate prediction of ionizing radiation exposure in low-Earth orbit is necessary in order to minimize risks to astronauts, spacecraft and instrumentation. To this end, models of the radiation environment, the AP-8 trapped proton model and the AE-8 trapped electron model, have been developed for use by spacecraft designers and mission planners. It has been widely acknowledged for some time now by the space radiation community that these models possess some major shortcomings. Both models cover only a limited trapped particle energy region and predictions at low altitudes are extrapolated from higher altitude data. With the launch of the first components of the International Space Station with numerous constellations of low-Earth orbit communications satellites now being planned and deployed, the inadequacies of these trapped particle models need to be addressed. Efforts are now underway both in the U.S. and in Europe to refine the AP-8 and AE-8 trapped particle models. This report is an attempt to collect a significant fraction of data for use in validation of trapped radiation models at low altitudes.

Benton, E. R.↗

The Observed Variance Between Predicted and Measured Radiation Dose in Breast and Prostate Patients Utilizing an In Vivo Dosimeter

Purpose: Report the results of using a permanently implantable dosimeter in radiation therapy: determine specific adverse events, degree of migration, and acquire dose measurements during treatment to determine difference between expected and measured dose. Methods and Materials: The Dose Verification System is a wireless, permanently implantable metal-oxide semiconductor field-effect transistor dosimeter using a bidirectional antenna for power and data transfer. The study cohort includes 36 breast (33 patients received two devices) and 29 prostate (21 patients received two devices) cancer patients. A total of 1,783 and 1,749 daily dose measurements were obtained on breast and prostate patients, respectively. The measurements were compared with the planned expected dose. Biweekly computed tomography scans were obtained to evaluate migration and the National Cancer Institute's Common Toxicity Criteria, version 3, was used to evaluate adverse events. Results: Only Grade I/II adverse events of pain and bleeding were noted. There were only four instances of dosimeter migration of >5 mm from known factors. A deviation of {>=}7% in cumulative dose was noted in 7 of 36 (19%) for breast cancer patients. In prostate cancer patients, a {>=}7% deviation was noted in 6 of 29 (21%) and 8 of 19 (42%) during initial and boost irradiation, respectively. The two patterns of dose deviation were random and systematic. Some causes for these differences could involve organ movement, patient movement, or treatment plan considerations. Conclusions: The Dose Verification System was not associated with significant adverse events or migration. The dosimeter can measure dose in situ on a daily basis. The accuracy and utility of the dose verification system complements current image-guided radiation therapy and intensity-modulated radiation therapy techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Atmospheric effects on radiation measurements

Two essentially distinct regions of the electromagnetic spectrum are discussed: (1) the scattering region in which the radiation energy is provided by the incident solar flux; and (2) the infrared region in which emission by the earth's surface and atmospheric gases supply radiative energy. In each of these spectral regions the atmosphere performs its dual function with respect to a remote sensing measurement of surface properties. The atmosphere acts both as a filter and as a noise generator removing and obscuring sought after information. Nevertheless, with proper application of concepts such as have been considered, it will be possible to remove these unwanted atmospheric effects and to improve identification techniques being developed.

Jurica, G. M.↗

Criticality detection method based on FP gamma radiation measurement

A method is proposed to evaluate the extent of subcriticality of an accident-damaged nuclear reactor. In this method the radiation ratio of two FP rare gas nuclides, {sup 88}Kr and {sup 133}Xe, is measured. From the measured value, the value in the core is estimated by correcting for the time required by the gases to diffuse from the core to the measuring point. A simple expression for neutron multiplication factor has been derived, which uses the corrected {sup 88}Kr-to-{sup 133}Xe radiation ratio and the {sup 88}Kr-to-{sup 133}Xe fission yield ratios from {sup 244}Cm and {sup 235}U but no information on the amount or distribution of fissile materials, making the proposed method very simple. The method has the advantage that FP rare gases can easily leak from the reactor core through many openings and gaps, reaching germanium counters without reacting with other materials. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Emittance of RSI Coatings Determined from Radiation Measurements in Arc Jet Tests

Simultaneous measurements were made on three surface insulation coatings for total surface radiation and radiation at discrete wavelengths between 0.88 and 4.5 microns. The mullite coating radiated all the applied heat at convective heat rates of 204 and 295 kw/sq m. Radiation from the ceramic mullite fiber coating was 170 kw/sq m at a heat rate of 454 kw/sq m. Effective total emissivity and spectral emissivity values were evaluated; all three coatings were significantly non-grey. Effective total emissivity values were 0.79 for mullite, 0.50 for ceramic mullite fiber, and 0.78 for silica composite.

Wakefield, R. M.↗

Vintage electronics for trusted radiation measurements and verified dismantlement of nuclear weapons

Information barriers are trusted measurement systems to confirm the authenticity of nuclear warheads based on their radiation signatures. Traditional inspection systems rely on complex electronics both for data acquisition and processing. Several research efforts have produced prototype systems, but it has proven difficult to demonstrate that hidden switches and side channels do not exist. After almost thirty years of research and development, no viable and widely accepted system has emerged. We pursue a fundamentally different approach: Our prototype of an inspection system uses vintage hardware built around a 6502 processor. The processor uses 8-micron technology and has only about 4,200 transistors. Vintage electronics may have a number of important advantages for applications where two parties need to simultaneously establish trust in the hardware used. CPUs designed in the distant past, at a time when their use for sensitive measurements was never envisioned, drastically reduce concerns that the other party implemented backdoors or hidden switches on the hardware level. We demonstrate the performance of a prototype system using an Apple IIe and a custom-made open-source data-processing board connected to a standard sodiumiodide radiation detector for low-resolution gamma spectroscopy. Data processing and analysis is exclusively done on the Apple IIe hardware. We show that subtle differences in radiation signatures can be detected in 2–3 minutes based on the result of a simple chi-squared test. Vintage electronics may therefore offer a new path toward fieldable, trusted information barriers.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Measured Radiation Patterns of the Boeing 91-Element ICAPA Antenna With Comparison to Calculations

This report presents measured antenna patterns of the Boeing 91-Element Integrated Circuit Active Phased Array (ICAPA) Antenna at 19.85 GHz. These patterns were taken in support of various communication experiments that were performed using the antenna as a testbed. The goal here is to establish a foundation of the performance of the antenna for the experiments. An independent variable used in the communication experiments was the scan angle of the antenna. Therefore, the results presented here are patterns as a function of scan angle, at the stated frequency. Only a limited number of scan angles could be measured. Therefore, a computer program was written to simulate the pattern performance of the antenna at any scan angle. This program can be used to facilitate further study of the antenna. The computed patterns from this program are compared to the measured patterns as a means of validating the model.

Lambert, Kevin M.↗

Future radiation measurements in low Earth orbit

The first Long Duration Exposure Facility (LDEF) mission has demonstrated the value of the LDEF concept for deep surveys of the space radiation environment. This paper will survey the types of measurements that could be done on a second LDEF mission. One of the most surprising discoveries on LDEF1 was the Be-7 that was found imbedded on the windward surface. LDEF2 could follow up on this discovery and search for evidence of other cosmogenic nuclei. Another experiment could be designed to investigate the presence of energetic heavy ions observed on LDEF1. The relative abundance of rare earths can also be used to search for evidence that cosmic rays accelerate in episodes which occur throughout their propagation in the stellar medium. Further investigations of radiation effects could also be undertaken. A second LDEF mission also offers the opportunity for new investigations such as measurements of cosmic ray differential energy spectrum to ultrahigh energies. These and other ideas will be discussed.

Adams, James H., Jr.↗

Two Methods for Retrieving UV Index for All Cloud Conditions from Sky Imager Products or Total SW Radiation Measurements

In the present study, we assess the cloud effects on UV Index (UVI) and total solar radiation (TR) as a function of cloud cover estimations and sunny conditions (from sky imaging products) as well as of solar zenith angle (SZA). These analyses are undertaken for a southern-hemisphere mid-latitude site where a 10-years dataset is available. It is confirmed that clouds reduce TR more than UV, in particular for obscured Sun conditions, low cloud fraction (< 60%) and large SZA (> 60º). Similarly, clouds enhance TR more than UV, mainly for visible Sun conditions, large cloud fraction and large SZA. Two methods to estimate UVI are developed: 1) from sky imaging cloud cover and sunny conditions, and 2) from TR measurements. Both methods may be used in practical operational applications, although Method 2 shows overall the best performance, since TR allows accounting for cloud optical properties. The mean absolute differences of Method 2 estimations with respect to measured values are 0.17 UVI units (for 1-minute data) and 0.79 Standard Erythemal Dose (SED) units (for daily integrations). Method 1 shows less accurate results but it is still suitable to estimate UVI: mean absolute differences are 0.37 UVI units and 1.6 SED.

clouds↗

Study of Shortwave Spectra in Fully 3D Environment: Synergy Between Scanning Radars and Spectral Radiation Measurements

The main theme for our research is the understanding and closure of the surface spectral shortwave radiation problem in fully 3D cloud situations by combining the new ARM scanning radars, shortwave spectrometers, and microwave radiometers with the arsenal of radiative transfer tools developed by our group. In particular, we define first a large number of cloudy test cases spanning all 3D possibilities not just the customary uniform-overcast ones. Second, for each case, we define a "Best Estimate of Clouds That Affect Shortwave Radiation" using all relevant ARM instruments, notably the new scanning radars, and contribute this to the ARM Archive. Third, we test the ASR-signature radiative transfer model RRTMG_SW for those cases, focusing on the near-IR because of long-standing problems in this spectral region, and work with the developers to improve RRTMG_SW in order to increase its penetration into the modeling community.

Wiscombe, Warren J.↗