Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “QUALITY FACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Coupling, Q-Factor, and Integration Aspects of Microsphere Applications

With suggested applications varying from microlaser and cavity QED through optical locking of diode lasers to modulators and sensors, high-Q silica microspheres with whispering-gallery (WG) modes so far remain the subject of tabletop feasibility demonstrations. Despite the uniquely high quality-factor and submillimeter dimensions suitable for tight packaging, this novel type of high-finesse cavity still has to be adapted to fiber- and integrated-optic hardware. In the visible and near infrared-band experiments (633-850nm) measuring the ringdown time tau of free oscillations, Q = (0.6 to 0.8 ) x 10(exp 10) has been obtained in silica spheres of diameter -800 microns (corresponding tau = 3 to 4 microseconds). It was proved that under normal laboratory conditions, quality-factor is subject to deterioration within several-minute scale down to (2 ... 3 ) x 10(exp 9). The responsible mechanism was identified as adsorption of a monolayer of atmospheric water, so that preservation of the ultimate Q requires manipulation in dry environment, or fast packaging into sealed devices. Larger Q can be expected closer to minimum of attenuation in fused silica alpha = 0.2 dB/km; Q greater than or equal to 1 x 10(exp 11) at lambda=1.55 microns, with corresponding energy storage time tau approx. 0.1ms. Experiments are currently underway to determine whether this high Q can be realized experimentally. The evident difficulty is that OH-related optical absorption has its peaks located near the reported minimum of attenuation in silica. We can also mention here that some of proposed fiber materials, yet not ready for fiber drawing, have been predicted to have smaller attenuation than fused silica and may be suitable for microsphere fabrication (sodium-magnesium silicate glass, alpha = 0.06dB/km). WG modes possess very small radiative loss (it does not prevent Q-10(exp 20) and more) and therefore are electromagnetically isolated and cannot be excited by free-space beams. If no modification (such as grating) is made on the sphere surface, the coupling has to he provided by an appropriate near-field device. A systematic theoretical approach has been recently developed to quantify the performance of near-field couplers for WG modes. Efficient coupling can be obtained upon fulfillment of two main conditions: (1) mode matching and (2) sufficient coupling strength to provide the buildup of a WG mode with a given intrinsic loss. In other words, the wave in the coupler has to be phase-matched and sufficiently overlapped with the WG mode to provide enough buildup in the cavity. If the coupling efficiency is characterized by the fractional depth K(sup 2) of the resonance dip in intensity transmittance observed upon varying the frequency of the exciting wave in the coupler.

Ilchenko, V. S.↗

Porous silicon ring resonator for compact, high sensitivity biosensing applications

A ring resonator is patterned on a porous silicon slab waveguide to produce a compact, high quality factor biosensor with a large internal surface area available for enhanced recognition of biological and chemical molecules. The porous nature of the ring resonator allows molecules to directly interact with the guided mode. Quality factors near 10,000 were measured for porous silicon ring resonators with a radius of 25 μm. A bulk detection sensitivity of 380 nm/RIU was measured upon exposure to salt water solutions. Specific detection of nucleic acid molecules was demonstrated with a surface detection sensitivity of 4 pm/nM.

47 OTHER INSTRUMENTATION↗

Anomalous bulk viscosity of two-phase fluids and implications for planetary interiors

The irreversible entropy production is calculated for the imposition of a pressure perturbation on a two-phase medium composed of a dilute suspension of droplets (or snowflakes) and a liquid phase of other materials. An absence of metastability is assumed, allowing the relaxation to be dominated by the solute finite diffusivity. The fluid medium was found to display a behavior suggestive of a bulk viscosity near 10 trillion P, a finding that is significant for studies of dissipation in planetary cores for tidal or seismic disturbances. A minimum quality factor for acoustic or tidal pressure oscillations and the accompanying frequency are calculated. An example is provided in terms of helium rain clouds in the deep interiors of giant planets. Additionally, a tidal quality factor of 10 to the 15th is found necessary to account for Io volcanism and resurfacing on Enceladus.

Stevenson, D. J.↗

Evaluation of 2 possible further developments of the UK in-flight radiation warning meter for SSTS

A mass reduction of the moderator and the response to the nucleon flux, responsible for the tissue-star component of the total-dose equivalent rate using a high atomic number material, are discussed. Radiation situations at SST cruising altitudes (approximately 20 km) due to solar proton flares were simulated in the stratosphere and on the ground. Actual stratospheric situations due to galactic cosmic radiation with a limited range of quality factor values (2-4) were encountered during slow ascents by balloons to 36 km. Synthetic situations obtained from high and low energy acclerator radiations were used to obtain radiation distributions having a larger range of quality factor values (11/2-9) than experienced in the stratosphere. The measurements made in these simulations related to the directly ionizing, neutron and tissue-star components of dose-equivalent rate. Due to the restricted range of neutron spectra encountered in the stratosphere, a significant mass reduction of the moderator by 4 kg was made, with the moderator clad with cadmium or some other slow neutron absorber.

Wilson, I. J.↗

Correction of Q Factor Effects for Simultaneous Collection of Elemental Analysis and Relaxation Times by Nuclear Magnetic Resonance

A new method for measurement of elemental analysis by nuclear magnetic resonance (NMR) of unknown samples is discussed in this report as a quick and robust means to measure elemental ratios without the use of internal or external calibration standards. The determination of elemental ratios was done by normalizing the signal intensities by the frequency dependent quality factor (Q) and the gyromagnetic ratios (γ) for each measured nucleus. The correction for the frequency dependence was found by characterizing the output signal of the probe as a function of the quality factor (Q) and the frequency, and the correction for γ was discussed in a previous study. A Carr–Purcell–Meiboom–Gill (CPMG) pulse sequence was used for evaluation of the relative signal intensities, which allows for derivation of elemental ratios, and was correspondingly used to simultaneously measure the T 2 * of samples for an added parameter for more accurate identification of unknown samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Commissioning of the prototype C75 cavities in a CEBAF cryomodule

Prototype cavities have been built at Jefferson Lab to increase the energy of future refurbished CEBAF cryomodules to 75 MeV in the most cost efficient way. Three such cavities, named "C75", have been built from ingot Nb material of different purity and have been processed and tested. The two better performing cavities have been assembled into a "cavity pair" and installed in the latest refurbished original CEBAF cryomodule. The cryomodule was installed and commissioned in CEBAF. The results from the commissioning of the C75 cavities, compared with the original CEBAF cavities, are presented in this article. The vertical test performance of the C75 cavities was preserved in the cryomodule with one of the cavities achieving the performance specification of an accelerating gradient of 19 MV/m with a quality factor of ~8×109 at 2.07 K. The performance in terms of microphonics and tuner operation was similar to that of original CEBAF cavities, as expected, and the high-order modes are properly damped. The quality factor of the two C75 cavities was the highest achieved in a CEBAF cryomodule, possibly due to the better magnetic flux expulsion of ingot Nb than standard fine-grain Nb.

Drury, Michael A.↗

Film Deposition, Cryogenic RF Testing and Materials Analysis of a Nb/Cu Single Cell SRF Cavity

In this study, we present preliminary results on using a cathodic-arc-discharge Nb plasma ion source to establish a Nb film-coated single-cell Cu cavity for SRF research. The polycrystalline Cu cavity was fabricated and mirror-surface-finished by a centrifugal barrel polishing (CBP) process at Jefferson Lab. Special pre-coating processes were conducted, in order to create a template-layer for follow-on Nb grain thickening. A sequence of cryogenic RF testing demonstrated that the Nb film does show superconductivity. But the quality factor of this Nb/Cu cavity is low as a result of high residual surface resistance. We are conducting a thorough materials characterization to explore if some microstructural defects or hydrogen impurities, led to such a low quality factor.

Zhao, Xin↗

Beyond Conventional Sensing: Hybrid Plasmonic Metasurfaces and Bound States in the Continuum

Fano resonances result from the strong coupling and interference between a broad background state and a narrow, almost discrete state, leading to the emergence of asymmetric scattering spectral profiles. Under certain conditions, Fano resonances can experience a collapse of their width due to the destructive interference of strongly coupled modes, resulting in the formation of bound states in the continuum (BIC). In such cases, the modes are simultaneously localized in the nanostructure and coexist with radiating waves, leading to an increase in the quality factor, which is virtually unlimited. In this work, we report on the design of a layered hybrid plasmonic-dielectric metasurface that facilitates strong mode coupling and the formation of BIC, resulting in resonances with a high quality factor. We demonstrate the possibility of controlling Fano resonances and tuning Rabi splitting using the nanoantenna dimensions. We also experimentally demonstrate the generalized Kerker effect in a binary arrangement of silicon nanodisks, which allows for the tuning of the collective modes and creates new photonic functionalities and improved sensing capabilities. Our findings have promising implications for developing plasmonic sensors that leverage strong light-matter interactions in hybrid metasurfaces.

36 MATERIALS SCIENCE↗

Properties of Superconducting Mo, Mo2n and Trilayer Mo2n-Mo-Mo2n Thin Films

We present measurements of the properties of thin film superconducting Mo, Mo2N and Mo2N/Mo/Mo2N trilayers of interest for microwave kinetic inductance detector (MKID) applications. Using microwave resonator devices, we investigate the transition temperature, energy gaps, kinetic inductance, and internal quality factors of these materials. We present an Usadel-based interpretation of the trilayer transition temperature as a function of trilayer thicknesses, and a 2-gap interpretation to understand the change in kinetic inductance and internal resonance quality factor (Q) as a function of temperature.

Superconducting↗

Modeling frequency instability in high-quality resonant experiments

Modern resonant sensing tools can achieve increasingly high quality factors, which correspond to extremely narrow linewidths. In such systems, time variation of the resonator’s natural frequency can potentially impact its ability to accumulate power and its resulting sensitivity. One such example is the Dark SRF experiment, which utilizes superconducting radio frequency (SRF) cavities with quality factors of Q ∼ 10 10 . Microscopic deformations of the cavity lead to stochastic jittering of its resonant frequency with amplitude 20 times its linewidth. Naively, one may expect this to lead to a large suppression in accumulated power. In this work, we study in detail the effects of frequency instability on high-quality resonant systems, utilizing the Dark SRF experiment as a case study. We show that the timescale of jittering is crucial to determining its effect on power accumulation. Namely, when the resonant frequency varies sufficiently quickly, the system accumulates power as if there were no jittering at all. This implies that the sensitivity of a jittering resonator is comparable to that of a stable resonator. In the case of Dark SRF, we find that jittering only induces a ∼ 10 % loss in power. Our results allow the dark-photon exclusion bound from Dark SRF’s pathfinder run to be refined, leading to a constraint that is an order of magnitude stronger than previously reported (corresponding to a signal-to-noise ratio that is four orders of magnitude larger). This result represents the world-leading constraint on dark photons over a wide range of masses below 6 μ eV and translates to the best laboratory-based limits on the photon mass m γ < 2.9 × 10 - 48 g .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active tuning of high-Q dielectric metasurfaces

Here, we demonstrate the active tuning of all-dielectric metasurfaces exhibiting high-quality factor (high-Q) resonances. The active control is provided by embedding the asymmetric silicon meta-atoms with liquid crystals, which allows the relative index of refraction to be controlled through heating. It is found that high quality factor resonances (Q = 270 ± 30) can be tuned over more than three resonance widths. Our results demonstrate the feasibility of using all-dielectric metasurfaces to construct tunable narrow-band filters.

36 MATERIALS SCIENCE↗

The image quality of ion computed tomography at clinical imaging dose levels

Purpose: Accurately predicting the range of radiotherapy ions in vivo is important for the precise delivery of dose in particle therapy. Range uncertainty is currently the single largest contribution to the dose margins used in planning and leads to a higher dose to normal tissue. The use of ion CT has been proposed as a method to improve the range uncertainty and thereby reduce dose to normal tissue of the patient. A wide variety of ions have been proposed and studied for this purpose, but no studies evaluate the image quality obtained with different ions in a consistent manner. However, imaging doses ion CT is a concern which may limit the obtainable image quality. In addition, the imaging doses reported have not been directly comparable with x-ray CT doses due to the different biological impacts of ion radiation. The purpose of this work is to develop a robust methodology for comparing the image quality of ion CT with respect to particle therapy, taking into account different reconstruction methods and ion species. Methods: A comparison of different ions and energies was made. Ion CT projections were simulated for five different scenarios: Protons at 230 and 330 MeV, helium ions at 230 MeV/u, and carbon ions at 430 MeV/u. Maps of the water equivalent stopping power were reconstructed using a weighted least squares method. The dose was evaluated via a quality factor weighted CT dose index called the CT dose equivalent index (CTDEI). Spatial resolution was measured by the modulation transfer function. This was done by a noise-robust fit to the edge spread function. Second, the image quality as a function of the number of scanning angles was evaluated for protons at 230 MeV. In the resolution study, the CTDEI was fixed to 10 mSv, similar to a typical x-ray CT scan. Finally, scans at a range of CTDEI’s were done, to evaluate dose influence on reconstruction error. Results: All ions yielded accurate stopping power estimates, none of which were statistically different from the ground truth image. Resolution (as defined by the modulation transfer function = 10% point) was the best for the helium ions (18.21 line pairs/cm) and worst for the lower energy protons (9.37 line pairs/cm). The weighted quality factor for the different ions ranged from 1.23 for helium to 2.35 for carbon ions. For the angle study, a sharp increase in absolute error was observed below 45 distinct angles, giving the impression of a threshold, rather than smooth, limit to the number of angles. Conclusions: The method presented for comparing various ion CT modalities is feasible for practical use. While all studied ions would improve upon x-ray CT for particle range estimation, helium appears to give the best results and deserves further study for imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the line Q degradation in hydrogen masers

In hydrogen masers, the atomic resonance quality factor is largely determined by the properties of the Teflon coating on the quartz storage bulb. Normally a good Teflon coating will last many years. On the other hand, there may be a relatively fast degradation of the quality factor if the Teflon coating is bad. A series of observations and measurements performed on an hydrogen maser that had successively a bad and a good Teflon coating are discussed.

Bernier, L. G.↗

Dosimetric results from the Mir orbital station

The Mir Orbital Station provided a unique platform on which to carry out a variety of space radiation dosimetry measurements. A number of experiments were conducted using a combination of passive detectors on the interior of the Mir during 1996-97. Thermoluminescent detectors were used to measure absorbed dose. CR-39 plastic nuclear track detectors were used to measure the LET spectra > or =5 keV.microm(-1). Results from TLDs and CR-39 PNTDs were combined to determine total dose and dose equivalent. Mean dose rate was found to decrease while mean dose equivalent rate and average quality factor increased with increasing shielding. Secondary particles from proton-induced target fragmentation interactions, not primary HZE particles, were found to be the largest contributor to the LET spectrum above 100 keV.microm(-1). During the 1997 measurements, mean quality factor was found to vary from 1.7 to 2.1 as a function of location within the Mir.

long duration↗

Atomic layer deposition of titanium nitride for quantum circuits

Superconducting thin films with high intrinsic kinetic inductance are of great importance for photon detectors, achieving strong coupling in hybrid systems, and protected qubits. We report on the performance of titanium nitride resonators, patterned on thin films (9–110 nm) grown by atomic layer deposition, with sheet inductances of up to 234 pH/. For films thicker than 14 nm, quality factors measured in the quantum regime range from 0.2 to 1.0 × 10 6 and are likely limited by dielectric two-level systems. Additionally, we show characteristic impedances up to 28 kΩ, with no significant degradation of the internal quality factor as the impedance increases. In conclusion, these high impedances correspond to an increased single photon coupling strength of 24 times compared to a 50 Ω resonator, transformative for hybrid quantum systems and quantum sensing.

36 MATERIALS SCIENCE↗

Radiation safety in commercial air traffic - A need for further study

The problem of radiation exposure of crewmembers in high altitude supersonic commercial aircraft is addressed. As a result of recent changes in the quality factors for radiological protection, it is found that worst case estimates of radiation exposure are now well above the exposure limits of the general population, and a reassessment of radiation impact on commercial aviation is needed, if the proposed quality factors are adopted. Calculations are presented from a study on neutron dosage equivalent rates. It is shown that a crew flying at altitudes near 13 km (43,000 ft) for 40 hr/mo would receive exposure levels of 47-75 Sv/yr, and it is suggested that such crewmembers be considered as radiation workers, rather than general population members. However, since present exposure estimates need to be improved, and the maximum permissible dose limits are currently under revision, the final exposure limits are, as yet, unclear, suggesting the need for further study to clarify the work status of commercial aircrews.

Wilson, John W.↗

An analysis of interplanetary space radiation exposure for various solar cycles

The radiation dose received by crew members in interplanetary space is influenced by the stage of the solar cycle. Using the recently developed models of the galactic cosmic radiation (GCR) environment and the energy-dependent radiation transport code, we have calculated the dose at 0 and 5 cm water depth; using a computerized anatomical man (CAM) model, we have calculated the skin, eye and blood-forming organ (BFO) doses as a function of aluminum shielding for various solar minima and maxima between 1954 and 1989. These results show that the equivalent dose is within about 15% of the mean for the various solar minima (maxima). The maximum variation between solar minimum and maximum equivalent dose is about a factor of three. We have extended these calculations for the 1976-1977 solar minimum to five practical shielding geometries: Apollo Command Module, the least and most heavily shielded locations in the U.S. space shuttle mid-deck, center of the proposed Space Station Freedom cluster and sleeping compartment of the Skylab. These calculations, using the quality factor of ICRP 60, show that the average CAM BFO equivalent dose is 0.46 Sv/year. Based on an approach that takes fragmentation into account, we estimate a calculation uncertainty of 15% if the uncertainty in the quality factor is neglected.

NASA Discipline Radiation Health↗

Al 0.68 Sc 0.32 N Lamb wave resonators with electromechanical coupling coefficients near 10.28%

Aluminum scandium nitride (Al 1-x Sc x N/AlScN) (x = 0.32) Lamb wave resonators (LWR) have been fabricated and tested to demonstrate electromechanical coupling coefficients (k t 2 ) in excess of 10%. The resonators exhibited an average k t 2 and unloaded quality factor (Q u ) of 10.28% and 711, respectively, when calculated from the measured data. Applying the Butterworth Van-Dyke (BVD) model to the measured data enabled the extraction of the resonator's lumped element parameters to calculate the motional quality factor (Q m ), which neglects the contributions of the electrical traces. For the best measured resonator response, results from the BVD model showed a Q m of 1184 and a resulting figure-of-merit (FOM = K 2 ·Q m ) of 100. Comparing the response of similar AlScN and AlN resonators shows that the AlScN LWR has a significantly lower motional resistance (R m ), suggesting that AlScN has a strong potential for use in piezoelectric microelectromechanical oscillators.

42 ENGINEERING↗