Quasitrapped electrons in the low L region. Preliminary results of a rocket observation on 22 January 1972

Suprathermal electrons in the energy range 5 - 100 keV were measured with thin-window proportional counters on board a sounding rocket. The flux of the electrons was found to increase with altitude in the range .100 - 550 km, corresponding to L = 1.15 - 1.22, the angular distribution to be peaked in the direction perpendicular to the geomagnetic line of force, and the energy to be represented by a power law.

Hayakawa, S.↗

Electron contamination in a mid-latitude soft X-ray astronomy experiment during an intense magnetic storm

A large area X-ray sky survey payload was launched from White Sands Missile Range (106 deg W 32 deg N) on 1 Nov. 1972 at 0530 hours U.T. The launch time coincided with intense geomagnetic activity (3 hour K sub p index = 8) following a solar flare. The data have been analyzed to determine possible contamination of X-ray data by large fluxes of low energy electrons that can precipitate down to low altitudes during magnetic storms. There is clear evidence in the data for low energy electrons of 10 - 50 keV contributing appreciably at about 200 km altitude in the 1 - 10 keV X-ray energy channels of the proportional counters used for the X-ray observations. The McIlwain parameters L and B for this altitude at White Sands are 1.25 and 0.46G, respectively.

Naranan, S.↗

Study of X-ray optics

The testing is reported of a polished Kanigen coated beryllium mirror in a soft X-ray telescope to be flown on a Skylark sounding rocket. This test involved inserting the telescope in a 220 foot long vacuum line and taking photographs of an X-ray resolution source. These photographs were then used to evaluate the performance of the telescope mirror as a function of distance from the focal plane and the angular distance off the telescope axis. A second test was made in which a point source was used to study the imaging characteristics by means of a pinhole and proportional counter placed in the telescope focal plane. A third test was conducted using a position sensitive detector. The efficiency and resolution was increased by polishing.

Froechtenigt, J. F.↗

High angular resolution cosmic X-ray astronomy observations in the energy range 0.15-2 keV and XUV observations of nearby stars from an attitude controlled rocket

The construction of a two dimensional focusing Wolter Type I mirror system for X-ray and XUV astronomical observations from an Astrobee F sounding rocket is described. The mirror design goal will have a one degree field, a 20-arc seconds resolution, an effective area of about 50 sq cm at 1 keV and 10 sq cm at 0.25 keV on axis. A star camera provides aspect data to about 15-arc seconds. Two detectors are placed at the focus with an interchange mechanism to allow a detector change during flight. The following specific developments are reported: (1) position sensitive proportional counter development; (2) channel plate multiplier development; (3) telescope mirror development and payload structure; (4) Australian rocket flight results; (5) Comet Kohoutek He I observation; and (6) Vela, Puppis A, and Gem-Mon bright patch observations.

Garmire, G. P.↗

Inorganic chemical investigation by X-ray fluorescence analysis - The Viking Mars Lander

The inorganic chemical investigation experiment added in August 1972 to the Viking Lander scientific package uses an energy-dispersive X-ray fluorescence spectrometer in which four sealed, gas-filled proportional counters detect X-rays emitted from samples of the Martian surface materials irradiated by X-rays from radioisotope sources (Fe-55 and Cd-109). The instrument is inside the Lander body, and samples are to be delivered to it by the Viking Lander Surface Sampler. Instrument design is described along with details of the data processing and analysis procedures. The results of the investigation will characterize the surface materials of Mars as to elemental composition with accuracies ranging from a few tens of parts per million (at the trace-element level) to a few per cent (for major elements) depending on the element in question.

Toulmin, P., III↗

Instrument to measure energy and charge of low energy interplanetary particles

An experiment to measure the charge composition and energy spectra of ultra low energy charged particles in interplanetary space has been developed and launched on the IMP 8 (Explorer 50) satellite on Oct. 26, 1973. The instrument consists of two separate sensors sharing common electronics. One of these sensors uses a thin window gas proportional counter to measure the rate of energy loss and a totally depleted silicon surface barrier detector to measure total energy of incoming particles. The energy range for two dimensional analysis extends from 300 KeV to 2.5 MeV for protons and 60 KeV/nucleon to 25 MeV/nucleon for iron with excellent resolution of individual chemical elements. The other sensor combines electrostatic deflection with total energy measurements in silicon surface barrier detectors to give the ionic charge and kinetic energy of the particle.

Tums, E.↗

Measurement of elemental abundance of very low energy solar cosmic rays

Heavy interplanetary particles (Z from 3 to 30) have been observed during a solar flare period between October 29 and November 4, 1972. The nuclear abundance has been determined by a two parameter analysis of a thin window proportional counter - solid state detector device aboard the Explorer 47 (IMP-7) satellite. Energy spectra are given for C, O and Fe. The elemental abundance relative to oxygen is determined for carbon, neon, magnesium, silicon and the iron group in the energy range 0.62 to 6.9 MeV/nucleon. For the Fe/O ratio no energy dependence could be observed within the error limits.

Hovestadt, D.↗

A rocket borne instrument for the study of soft X-ray emission from cosmic X-ray sources

Details about a rocket-borne instrument designed for studying the various characteristics of soft X-ray emission from cosmic X-ray sources in the energy range of 0.2 to 3 keV are presented. The X-ray detector consists of a bank of four multilayer, wall-less proportional counters, each with an area of 400 sq cm. The detectors are covered by windows of 1.4-micron polypropylene and are maintained at a constant pressure in flight using a gas control system. Two of the detectors are equipped with 0.4- by 10-deg collimators for mapping the spatial distribution of soft X-rays from extended X-ray sources. A pair of balanced filters consisting of oxygen and CF4 are used for detecting oxygen emission lines.

Agrawal, P. C.↗

A new magnetic spectrometer system for cosmic ray studies

The balloon flight prototype or a cosmic ray superconducting magnet experiment designed for operation on the Space Shuttle is described. The physical and operating parameters of the scintillation, Cerenkov, emulsion and multiwire proportional counters used in the system for charge and rigidity measurements is given as well as the on-board data handling procedures.

Golden, R. L.↗

Observations of solar X-ray bursts in the energy range 5-15 keV

Bursts of solar X-rays in the energy range 5-15 keV are associated with flares and are due to thermal emission from a hot coronal plasma. The results of the first study of a large sample of separate bursts, 197 events associated with subflares, and of a few events of importance 1 are presented. The observations were made by a proportional counter on the satellite OSO-7 from October, 1971 to June, 1972. In most cases, the temperature characterizing the X-ray spectrum rises impulsively at the onset of the burst and then declines slowly throughout the remainder of the burst. The emission measure rises exponentially with a time scale of 30-100 sec and then declines slowly on a time scale of the order of 1,000 sec. It is shown that the growth of the thermal energy in the flare plasma throughout the burst can be due to the heating of new cool material.

Datlowe, D. W.↗

Observation of X-ray emission from M31

Observation of X-ray emission from M31 in the 0.5- to 5.0-keV band, using rocket-borne proportional counters. The integrated flux corresponds to (2.2 plus or minus 0.6) x 10 to the 39th ergs/sec at M31, and is confined chiefly to a region coinciding with the optical image of the galaxy. The spectrum has a slope similar to the bright Galactic X-ray sources. The intensity, spectral, and spatial data suggest that the bulk of X-ray emission from M31, and by inference from most normal galaxies, is due to a small group of highly luminous sources, in agreement with the Galactic X-ray luminosity function.

Bowyer, S.↗

Measurement of supersmall quantities of Ar37 and H3

The results of measurements made on supersmall quantities of Ar-37 and H-3 by a low-background installation based on miniature proportional counters are presented. The article considers the sensitivity limit for the recording of Ar-37 and H-3.

Kocharov, G. E.↗

Continued investigation of kinetic aspects of bone mineral metabolism

The total body calcium in humans was determined by measuring expired Ar-37 after neutron irradiation. The excretion of Ar-37 from humans was found to be much slower than the excretion from rats and dogs, and to be related to the age of a person. A study of the uniformity of the Ar-37 production throughout the thickness of the body was studied using phantoms. The results indicate that it should be possible to obtain a uniformity within plus or minus 3% for the production of Ar-37 per unit of calcium by using a bilateral irradiation. New low background, large volume proportional counters were developed and constructed, for more sensitive measurement of Ar-37 in the expired air from patients. A new irradiation enclosure was developed for measuring total body calcium in rats by the Ar-37 method. With this enclosure the Ar-37 production per gram of calcium is constant with a standard deviation of plus or minus 2.8% for any size rat between 100 and 500 grams. The use of Na-22 as measure of bone replacement in the fractured femur of a dog was not successful.

Palmer, H. E.↗

X-ray astronomy

Various experiments in X-ray astronomy are described. The occurrence of lunar occultations of the Crab Nebula were utilized to determine the spatial distribution of X-ray emitting regions in the nebula. Study of the Cygnus Loop included a search for a central X-ray point source for the area and measurement of the energy spectrum of the flux from the supernova remnant. The X-ray morphology of the Perseus cluster of galaxies was studied. X-ray spectra of different points in the cluster were also obtained. In addition, the construction of a high resolution gas fluorescence proportional counter for application to X-ray astronomy is discussed.

Novick, R.↗

Atmospheric X-ray emission experiment for shuttle

An experiment designed to measure the spatial, temporal, and energy distribution of X-ray aurorae produced by precipitating electrons, is presented. The experiment will provide vital data on solar-terrestrial relationships that may lead to defining the transfer mechanism that causes certain terrestrial weather events and climatological behavior. An instrument concept is discussed, and is based on a spatially sensitive multiwire proportional counter, combined with collimators to produce X-ray images of the aurorae. An instrument pointing system, on which the counter can be mounted, will provide the required altitude control, and can be operated by a Spacelab payload specialist for full control over its observing and data taking modes.

Goldberg, R. A.↗

Thin films for X-ray astronomy

A method is described for casting the commercial plastic known as Formvar directly on the surface of water and building up the desired thickness by a lamination of several layers. The thin, plastic films obtained can be used for the entrance window in the proportional counters normally used as X-ray detector in rocket-borne astrophysical experiments. Attention is given to three films, each of which has been flown several times on Aerobee sounding rockets.

Williamson, F.↗

Large area extreme ultraviolet focusing collector

A grazing incidence one-dimensional focusing collector for use in the extreme ultraviolet is described. The collector has a field of view of 1 x 50 deg, a focal length of 3015 cm, and a total unobstructed area of 224 sq cm. The instrument employs an interchangeable detector package of either channel-electron multipliers or proportional counters which yield a limiting sensitivity of 1.0 photons/sq cm sec A at 170 A and 0.05 photons/sq cm sec A at 90 A, respectively, for one second integrations. The design and calibration of the instrument are described in detail. Data obtained by this instrument during recent rocket flights are presented.

Henry, P.↗

Soft X-ray spectroscopy of three extragalactic sources

Soft X-ray spectra (0.5 to 5 KeV) acquired with a rocket-borne argon-methane proportional counter are reported for M87, 3C 273, and NGC 4151. The counter sensitivity range allowed derivation of simultaneous information on the magnitude of soft X-ray absorption and the slope of the hard X-ray spectrum. Error estimation techniques for the free parameters of X-ray spectra are analyzed, and the results are applied to the spectra previously reported for these sources. It is shown that the technique used to analyze the previous spectra can drastically underestimate the magnitude of errors, and it is concluded that the proposed division of extragalactic X-ray sources into two groups according to the magnitude of absorption in their spectra is premature.

Margon, B.↗