Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Process Automation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Technology for Innovation in Radiation Oncology

Radiation therapy is an effective, personalized cancer treatment that has benefited from technological advances associated with the growing ability to identify and target tumors with accuracy and precision. Given that these advances have played a central role in the success of radiation therapy as a major component of comprehensive cancer care, the American Society for Radiation Oncology (ASTRO), the American Association of Physicists in Medicine (AAPM), and the National Cancer Institute (NCI) sponsored a workshop entitled “Technology for Innovation in Radiation Oncology,” which took place at the National Institutes of Health (NIH) in Bethesda, Maryland, on June 13 and 14, 2013. The purpose of this workshop was to discuss emerging technology for the field and to recognize areas for greater research investment. Expert clinicians and scientists discussed innovative technology in radiation oncology, in particular as to how these technologies are being developed and translated to clinical practice in the face of current and future challenges and opportunities. Technologies encompassed topics in functional imaging, treatment devices, nanotechnology, and information technology. The technical, quality, and safety performance of these technologies were also considered. A major theme of the workshop was the growing importance of innovation in the domain of process automation and oncology informatics. The technologically advanced nature of radiation therapy treatments predisposes radiation oncology research teams to take on informatics research initiatives. In addition, the discussion on technology development was balanced with a parallel conversation regarding the need for evidence of efficacy and effectiveness. The linkage between the need for evidence and the efforts in informatics research was clearly identified as synergistic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The statistical analysis techniques to support the NGNP fuel performance experiments

This paper describes the development and application of statistical analysis techniques to support the Advanced Gas Reactor (AGR) experimental program on Next Generation Nuclear Plant (NGNP) fuel performance. The experiments conducted in the Idaho National Laboratory’s Advanced Test Reactor employ fuel compacts placed in a graphite cylinder shrouded by a steel capsule. The tests are instrumented with thermocouples embedded in graphite blocks and the target quantity (fuel temperature) is regulated by the He–Ne gas mixture that fills the gap volume. Three techniques for statistical analysis, namely control charting, correlation analysis, and regression analysis, are implemented in the NGNP Data Management and Analysis System for automated processing and qualification of the AGR measured data. The neutronic and thermal code simulation results are used for comparative scrutiny. The ultimate objective of this work includes (a) a multi-faceted system for data monitoring and data accuracy testing, (b) identification of possible modes of diagnostics deterioration and changes in experimental conditions, (c) qualification of data for use in code validation, and (d) identification and use of data trends to support effective control of test conditions with respect to the test target. Analysis results and examples given in the paper show the three statistical analysis techniques providing a complementary capability to warn of thermocouple failures. It also suggests that the regression analysis models relating calculated fuel temperatures and thermocouple readings can enable online regulation of experimental parameters (i.e. gas mixture content), to effectively maintain the fuel temperature within a given range.

99 GENERAL AND MISCELLANEOUS↗

Method for analyzing passive silicon carbide thermometry with a continuous dilatometer to determine irradiation temperature

Silicon carbide is used as a passive post-irradiation temperature monitor because the irradiation defects will anneal out above the irradiation temperature. The irradiation temperature is determined by measuring a property change after isochronal annealing, i.e., lattice spacing, dimensions, electrical resistivity, thermal diffusivity, or bulk density. However, such methods are time-consuming since the steps involved must be performed in a serial manner. This work presents the use of thermal expansion from continuous dilatometry to calculate the SiC irradiation temperature, which is an automated process requiring minimal setup time. Analysis software was written that performs the calculations to obtain the irradiation temperature and removes possible user-introduced error while standardizing the analysis. In addition, this method has been compared to an electrical resistivity and isochronal annealing investigation, and the results revealed agreement of the calculated temperatures. These results show that dilatometry is a reliable and less time-intensive process for determining irradiation temperature from passive SiC thermometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CHARMM-GUI Nanomaterial Modeler for Modeling and Simulation of Nanomaterial Systems

Molecular modeling and simulation are invaluable tools for nanoscience that predict mechanical, physicochemical, and thermodynamic properties of nanomaterials and provide molecular-level insight into underlying mechanisms. However, building nanomaterial-containing systems remains challenging due to the lack of reliable and integrated cyberinfrastructures. Here we present Nanomaterial Modeler in CHARMM-GUI, a web-based cyberinfrastructure that provides an automated process to generate various nanomaterial models, associated topologies, and configuration files to perform state-of- the-art molecular dynamics simulations using most simulation packages. The nanomaterial models are based on the interface force field, one of the most reliable force fields (FFs). The transferability of nanomaterial models among the simulation programs was assessed by single-point energy calculations, which yielded 0.01% relative absolute energy differences for various surface models and equilibrium nanoparticle shapes. Three widely used Lennard-Jones (LJ) cutoff methods are employed to evaluate the compatibility of nanomaterial models with respect to conventional biomolecular FFs: simple truncation at r = 12 Å (12 cutoff), force-based switching over 10 to 12 Å (10-12 fsw), and LJ particle mesh Ewald with no cutoff (LJPME). The FF parameters with these LJ cutoff methods are extensively validated by reproducing structural, interfacial, and mechanical properties. As a result, we find that the computed density and surface energies are in good agreement with reported experimental results, although the simulation results increase in the following order: 10-12 fsw <12 cutoff < LJPME. Nanomaterials in which LJ interactions are a major component show relatively higher deviations (up to 4% in density and 8% in surface energy differences) compared with the experiment. Nanomaterial Modeler's capability is also demonstrated by generating complex systems of nanomaterial-biomolecule and nanomaterial-polymer interfaces with a combination of existing CHARMM-GUI modules. We hope that Nanomaterial Modeler can be used to carry out innovative nanomaterial modeling and simulations to acquire insight into the structure, dynamics, and underlying mechanisms of complex nanomaterial-containing systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase evolution and amorphous stability upon solid-state reaction in superlattice like Ge–Sb–Te combinatorial thin-film

In this paper, the superlattice-like (SLL) Ge–Sb–Te combinatorial thin films were prepared by using a high-throughput ion beam sputtering system. The phase evolution and amorphous stability of such films undergoing heat treatment as a function of the coating sequence and modulation period were systematically studied. The composition structure diagram was constructed via an automated process of data obtained by high-throughput synchrotron micro-X-ray diffraction and lab-based micro-X-ray fluorescence. Furthermore, the element distribution and microstructure in the depth direction of the SLL thin films were characterized with time-of-flight secondary ion mass spectrometry and transmission electron microscopy, respectively. These studies demonstrated that the coating sequence has a significant effect on the element distribution in the as-deposited SLL thin films and the structure of the final product upon solid-state reaction. Reducing the modulation period of the SLL thin film improves the stability of the amorphous Ge–Sb–Te phase. This work lays a solid foundation for the rational design of SLL Ge–Sb–Te thin films to improve their performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pipe Parity Analysis of Seawater Desalination in the United States: Exploring Costs, Energy, and Reliability via Case Studies and Scenarios of Emerging Technology

As climate change-induced variables exacerbate water scarcities, the use of seawater reverse osmosis (SWRO) membrane desalination technology for treating seawater could potentially provide a long-term drought-proof source of drinking water. This study carried out a technoeconomic assessment (TEA) for three SWRO desalination plants in the U.S. and one in Israel to set baselines for the cost and energy consumption for seawater desalination. In addition, a breakeven curve for implementing SWRO desalination was estimated in relation to the cost of water conservation measures to meet drought-induced reduction of the traditional water supply. The results show that the cost of SWRO water production scales with the plant capacity while energy intensity is not dramatically different across the plants. The higher cost in some U.S. plants is due to high capital investment, including land acquisition and permitting. Variations in plant capacity utilization have the greatest impact on the levelized cost of water (LCOW) over the plant service life, suggesting the importance of reducing fouling and maintenance-related downtime. Scenario analysis of fixed labor cost reduction through process automation indicates investments in automation and sensing technology could result in long-term savings. Breakeven analysis shows the decision to adopt SWRO is highly dependent on the local cost associated with water conservation to meet water supply reduction. Moreover, a small reduction in SWRO cost can influence a shift toward the adoption of SWRO over water conservation measures. Incorporation of future water demand, water conservation potential, and water stress data around the nation indicates SWRO desalination could be an important contributor to the future municipal drinking water portfolio in the U.S.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Computational Framework for Machine-Learning-Enabled 13 C Fluxomics

13 C metabolic flux analysis (MFA) has emerged as a powerful tool for synthetic biology. This optimization-based approach suffers long computation time and unstable solutions depending on the initial guess. Here, we develop a machine-learning-based framework for 13 C fluxomics. Specifically, training and test data sets are generated by metabolic network decomposition and flux sampling, in which flux ratios at metabolic nodes and simulated labeling patterns of metabolites are used as training targets and features, respectively. To improve prediction accuracy and simplify the model, automated processes are developed for flux ratio selection based on solvability and feature screening based on importance. We found that predictive performance can be significantly improved using both amino acids and central carbon metabolites in comparison with amino acids alone. Together with measured external fluxes, the predicted flux ratios determine the mass balance system, yielding global flux distributions. This approach is validated by flux estimation using both simulated and experimental data in comparison with canonical 13 C MFA. The approach represents a reliable fluxomics method readily applicable to high-throughput metabolic phenotyping, which highlights the advances of intelligent learning algorithms in synthetic biology, specifically in the Test and Learn stage of the Design-Build-Test-Learn cycle.

13C metabolic flux analysis↗

High-Throughput Characterization and Optimization of Polyamide Hydrolase Activity Using Open Port Sampling Interface Mass Spectrometry

Enzymatic biodegradation of polymers, such as polyamides (PA), has the potential to cost-effectively reduce plastic waste, but enhancements in degradation efficiency are needed. Engineering enzymes through directed evolution is one pathway toward identification of critical domains needed for improving activity. However, screening such enzymatic libraries (100s-to-1000s of samples) is time-consuming. Here we demonstrate the use of robotic autosampler (PAL) and immediate drop on demand technology (I.DOT) liquid handling systems coupled with open-port sampling interface-mass spectrometry (OPSI-MS) to screen for PA6 and PA66 hydrolysis by 6-aminohexanoate-oligomer endo-hydrolase (nylon hydrolase, NylC) in a high-throughput (8–20 s/sample) manner. The OPSI-MS technique required minimal sample preparation and was amenable to 96-well plate formats for automated processing. Enzymatic hydrolysis of PA characteristically produced soluble linear oligomer products that could be identified by OPSI-MS. Incubation temperatures and times were optimized for PA6 (65 °C, 24 h) and PA66 (75 °C, 24 h) over 108 experiments. In addition, the I.DOT/OPSI-MS quantified production of PA6 linear dimer (8.3 ± 1.6 μg/mL) and PA66 linear monomer (13.5 ± 1.5 μg/mL) by NylC with a lower limit of detection of 0.029 and 0.032 μg/mL, respectively. For PA6 and PA66, linear oligomer production corresponded to 0.096 ± 0.018% and 0.204 ± 0.028% conversion of dry pellet mass, respectively. The developed methodology is expected to be utilized to assess enzymatic hydrolysis of engineered enzyme libraries, comprising hundreds to thousands of individual samples.

47 OTHER INSTRUMENTATION↗

Investigation of a tellurium-packed column for isolation of astatine-211 from irradiated bismuth targets and demonstration of a semi-automated system

Astatine-211 is an attractive radionuclide for use in targeted alpha therapy of blood-borne diseases and micrometastatic diseases. Efficient isolation methods that can be adapted to robust automated 211 At isolation systems are of high interest for improving the availability of 211 At. Based on the early studies of Bochvarova and co-workers involving isolation of 211 At from irradiated thorium targets, we developed a method for 211 At isolation from bismuth targets using tellurium-packed columns. Dissolution of irradiated bismuth targets is accomplished using HNO 3 ; however, 211 At is not captured on the Te column material in this matrix. Our method involves slow addition of aqueous NH 2 OH·HCl to the Bi target dissolved in HNO 3 to convert to a HCl matrix. The amount of NH 2 OH·HCl was optimized because (1) the quantity of NH 2 OH·HCl used appears to affect the radiolabeling yield of phenethyl- closo -decaborate(2-) (B10)-conjugated antibodies and (2) reducing the volume of NH 2 OH·HCl solution can effectively shorten the overall isolation time. A proof-of-concept semi-automated process has been demonstrated using targets containing ~0.96 GBq (~26 mCi) of 211 At. High isolation yields (88–95%) were obtained. Radiochemical purity of the isolated 211 At was assessed by radio-HPLC. Concentrations of Bi and Te contaminants in the 211 At and the astatinated antibodies were evaluated using ICP-MS.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Mass spectrometry-based monitoring of millisecond protein–ligand binding dynamics using an automated microfluidic platform

Characterizing protein-ligand binding dynamics is crucial for understanding protein function and developing new therapeutic agents. We have developed a novel microfluidic platform that features rapid mixing of protein and ligand solutions, variable incubation times, and on-chip electrospray ionization to perform label-free, solution-based monitoring of protein-ligand binding dynamics. This platform offers many advantages including automated processing, rapid mixing, and low sample consumption.

Environmental Molecular Sciences Laboratory↗

CRYOGENIC CONTROLS FOR FERMILAB'S SRF CAVITIES AND TEST FACILITY

A new superconducting radio frequency (SRF) cavities test facility is now operational at Fermilab's Meson Detector Building (MDB). The Cryogenic Test Facility (CTF), located in a separate building 500 m away, supplies the facility with cryogens. The design incorporates ambient temperature pumping for superfluid helium production, as well as three 0.6 kW at 4.5 K refrigerators, five screw compressors, a helium purifier, helium and nitrogen inventory, cryogenic distribution system, and a variety of test cryostats.To control and monitor the vastly distributed cryogenic system, a flexible scheme has been developed. Both commercial and experimental physics tools are used. APACS+, a process automation control system from Siemens-Moore, is at the heart of the design. APACS+ allows engineers to configure an ever evolving test facility while maintaining control over the plant and distribution system. APACS+ nodes at CTF and MDB are coupled by a fiber optic network. DirectLogic205 PLCs by KOYO are used as the field level interface to most I/O.The top layer of this system uses EPICS (Experimental Physics and Industrial Control System) as a SCADA/HMI. Utilities for graphical display, control loop setting, real time/historical plotting and alarming have been implemented by using the world-wide library of applications for EPICS.OPC client/server technology is used to bridge across each different platform.This paper presents this design and its successful implementation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design of an Automated System for Synthesis of [18 F] FDG for PET Investigation at IFIN-HH Bucharest

A novel apparatus constructed at IFIN-HH is described for automated synthesis of radiopharmaceuticals labeled with {sup 18}F for use in positron emission tomography (PET) investigations. [18 F] fluoride was produced at the IFIN-HH cyclotron by irradiation of H{sub 2}O enriched 97% in {sup 18}O with 13 MeV deuterons, or 8 MeV protons. The irradiated H{sub 2}O was transferred (injected) into the radiochemical fully-automated processing systems which ensured the separation of {sup 18}F from H{sub 2}O, the labeling with {sup 18}F, and finally purified by filtration with selective absorbants. The system is easy to operate and contains a programmable logical controller that manages the entire operation program stored in its internal memory. The computer is used to assist the operator during the different steps of synthesis and to allow visualization of the process and printing the report. The device was used for used for the production of 2-[18 F] FLUORO-2-DEOXY-D-GLUCOSE at the IFIN-HH cyclotron, one of the most used radiopharmaceutical in PET investigations. The synthesis module is configured so that is flexible enough to accomplish other nucleophile reactions of labeling with short lived radioisotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Gallium nitride L3 photonic crystal cavities with an average quality factor of 16 900 in the near infrared

Photonic crystal point-defect cavities were fabricated in a GaN free-standing photonic crystal slab. The cavities are based on the popular L3 design, which was optimized using an automated process based on a genetic algorithm, in order to maximize the quality factor. Optical characterization of several individual cavity replicas resulted in an average unloaded quality factor Q = 16 900 at the resonant wavelength λ∼1.3 μm, with a maximal measured Q value of 22 500. The statistics of both the quality factor and the resonant wavelength are well explained by first-principles simulations including fabrication disorder and background optical absorption.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Validation of Geant4 hadronic generators versus thin target data

The GEANT4 toolkit is widely used for simulation of high energy physics (HEP) experiments, in particular, those at the Large Hadron Collider (LHC). The requirements of robustness, stability and quality of simulation for the LHC are demanding. This requires an accurate description of hadronic interactions for a wide range of targets over a large energy range, from stopped particle reactions to low energy nuclear interactions to interactions at the TeV energy scale. This is achieved within the Geant4 toolkit by combining a number of models, each of which are valid within a certain energy domain. Comparison of these models to thin target data over a large energy range indicates the strengths and weaknesses of the model descriptions and the energy range over which each model is valid. Software has been developed to handle the large number of validation tests required to provide the feedback needed to improve the models. An automated process for carrying out the validation and storing/displaying the results is being developed and will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LIQUID: an-open source software for identifying lipids in LC-MS/MS-based lipidomics data

We introduce an open-source software, LIQUID, for semi-automated processing and visualization of LC-MS/MS based lipidomics data. LIQUID provides users with the capability to process high throughput data and contains a customizable target library and scoring model per project needs. The graphical user interface provides visualization of multiple lines of spectral evidence for each lipid identification, allowing rapid examination of data for making confident identifications of lipid molecular species.

Environmental Molecular Sciences Laboratory↗

Velo and REXAN - Integrated Data Management and High Speed Analysis for Experimental Facilities

The Chemical Imaging Initiative at the Pacific Northwest National Laboratory (PNNL) is creating a ‘Rapid Experimental Analysis’ (REXAN) Framework, based on the concept of reusable component libraries. REXAN allows developers to quickly compose and customize high throughput analysis pipelines for a range of experiments, as well as supporting the creation of multi-modal analysis pipelines. In addition, PNNL has coupled REXAN with its collaborative data management and analysis environment Velo to create an easy to use data management and analysis environments for experimental facilities. This paper will discuss the benefits of Velo and REXAN in the context of three examples: PNNL High Resolution Mass Spectrometry - reducing analysis times from hours to seconds, and enabling the analysis of much larger data samples (100KB to 40GB) at the same time · ALS X-Ray tomography - reducing analysis times of combined STXM and EM data collected at the ALS from weeks to minutes, decreasing manual work and increasing data volumes that can be analysed in a single step ·Multi-modal nano-scale analysis of STXM and TEM data - providing a semi automated process for particle detection The creation of REXAN has significantly shortened the development time for these analysis pipelines. The integration of Velo and REXAN has significantly increased the scientific productivity of the instruments and their users by creating easy to use data management and analysis environments with greatly reduced analysis times and improved analysis capabilities.

Kleese van Dam, Kerstin↗

Towards Automatically Matching Security Advisories to CPEs: String Similarity-based Vendor Matching

When a vulnerability is reported by the National Vulnerability Database (NVD), affected products are listed in the structured Common Platform Enumeration (CPE) format. Unfortunately, if the vulnerability is in a software library (e.g., Log4j), it will not include CPEs for each product containing that library. In these cases, security operators need to manually read the vendor's or third-party security advisories to see if their product is affected. However, these advisories do not report affected products in a structured format, which prevents automated processing, This paper makes the first effort towards automatically constructing structured CPEs for the vulnerable products in a non-NVD security advisory from the unstructured data in the advisory. Since this is a very challenging problem, this paper specifically focuses on the initial but key step of matching the un-structured vendor names in security advisories to the structured vendor representations in the standard CPE format. We explore the feasibility of using string similarity to solve the problem. The basic idea is to compare a vendor name from the non-NVD advisory with each vendor in the official CPE dictionary. The CPE vendor with the highest similarity score to the advisory's vendor will be considered as the match. We first conduct an experimental, comparative study of multiple mainstream string similarity metrics for this matching problem. To improve the performance, we then design a new string similarity metric that is adapted from an existing metric by weighing different tokens in the advisory's vendor name differently.

McClanahan, Kylie↗

Automated Realistic Testbed Synthesis for Power System Communication Networks based on Graph Metrics

Communication networks are integral to modern power grid operations and are becoming increasingly critical as grid dynamics speed up and as more controls become closed-loop in form. Focusing on the interdependence between the physical grid and the communication system, we identify several key characteristics and typical graph properties based on analysis of a real communication system for a power grid. Moreover, an automated process was provided for synthetic testbed in the NS-3 simulator for the power system test case, and its network characteristics have been further derived for power system monitoring and control applications

Graph Analysis, Synthetic Testbed, communication n↗