Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

SYNCA: A Synthetic Cyclotron Antenna for the Project 8 Collaboration

Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for measuring the kinetic energy of charged particles through a precision measurement of the frequency of the cyclotron radiation generated by the particle's motion in a magnetic field. The Project 8 collaboration is developing a next-generation neutrino mass measurement experiment based on CRES. One approach is to use a phased antenna array, which surrounds a volume of tritium gas, to detect and measure the cyclotron radiation of the resulting β-decay electrons. To validate the feasibility of this method, Project 8 has designed a test stand to benchmark the performance of an antenna array at reconstructing signals that mimic those of genuine CRES events. To generate synthetic CRES events, a novel probe antenna has been developed, which emits radiation with characteristics similar to the cyclotron radiation produced by charged particles in magnetic fields. This paper outlines the design, construction, and characterization of this Synthetic Cyclotron Antenna (SYNCA). Furthermore, we perform a series of measurements that use the SYNCA to test the position reconstruction capabilities of the digital beamforming reconstruction technique. Finally, we find that the SYNCA produces radiation with characteristics closely matching those expected for cyclotron radiation and reproduces experimentally the phenomenology of digital beamforming simulations of true CRES signals.

47 OTHER INSTRUMENTATION↗

Post irradiation examination of a uranium-zirconium hydride TRIGA fuel element

Low-enriched (LEU) U-ZrH fuel, with a 235 U content less than 20% of the total uranium, is being evaluated for possible use in different types of reactors, including space nuclear systems, light water reactors (LWRs) and micro-reactors. As a result, it is beneficial to better understand the macrostructural and microstructural changes that occur in this fuel during irradiation. This paper reports the results of the post irradiation examination of an LEU U-ZrH fuel element (30 wt.% U, <20% 235 U) using neutron radiography, precision gamma scanning, chemical analysis, optical metallography and scanning electron microscopy combined with energy dispersive spectroscopy and wavelength dispersive spectroscopy, where the fuel element was irradiated in a Training, Research, Isotope, General Atomics (TRIGA) reactor. Results of microstructural characterization indicated some dehydriding and cracking of the U-ZrH fuel occurred during irradiation; an axial and radial burnup gradient existed in the fuel during irradiation, as measured by gamma scanning and chemical analysis; negligible microstructural changes transpired during irradiation, based on comparison of irradiated and as-fabricated U-ZrH fuel microstructures; and, negligible, fission product-rich, phases could be resolved in a U-ZrH fuel that was irradiated to a calculated 20% depletion of 235 U.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

[Microfabricated X-ray Optics Technology Development for the Constellation X-Mission]

MIT has previously developed advanced methods for the application of silicon microstructures (so-called microcombs) in the precision assembly of foil x-ray optics in support of the Constellation-X Spectroscopy X-ray Telescope (SXT) technology development at the NASA Goddard Space Flight Center (GSFC). During the first year of the above Cooperative Agreement, MIT has developed a new, mature, potentially high- yield process for the manufacturing of microcombs that can be applied to a range of substrates independent of thickness. MIT also developed techniques to extract microcomb accuracy from an assembly truss metrology test stand and to extend the dynamic range of its Shack-Hartmann foil metrology tool. The placement repeatability of foil optics with microcombs in the assembly truss has been improved by a factor of two to approximately 0.15 micron. This was achieved by electric contact determination in favor of determining contact through force measurements. Development work on a stress-free thin foil holder was also supported by this agreement and successfully continued under a different grant.

Schattenburg, Mark L.↗

The Physical Conditions of a Lensed Star-Forming Galaxy at Z=1.7

We report rest-frame optical Keck/NIRSPEC spectroscopy of the brightest lensed galaxy yet discovered, RCSGA 032727-132609 at z=1.7037. From precise measurements of the nebular lines, we infer a number of physical properties: redshift ' extinction, star formation rate ' ionization parameter, electron density, electron temperature, oxygen abundance, and N/O, Ne/O, and Ar/O abundance ratios, The limit on [O III] 4363 A tightly constrains the oxygen abundance via the "direct" or Te method, for the first time in an average-metallicity galaxy at z approx.2. We compare this result to several standard "bright-line" O abundance diagnostics, thereby testing these empirically-calibrated diagnostics in situ. Finally, we explore the positions of lensed and unlensed galaxies in standard diagnostic diagrams, to explore the diversity of ionization conditions and mass-metallicity ratios at z=2.

Rigby, Jane↗

Physical Conditions of a Lensed Star-Forming Galaxy at Z=1.7

We report rest-frame optical Keck/NIRSPEC spectroscopy of the brightest lensed galaxy yet discovered, RCSGA 032727-132609 at z=1.7037. From precise measurements of the nebular lines, we infer a number of physical properties: redshift, extinction, star formation rate, ionization parameter, electron density, electron temperature, oxygen abundance, and N/O, Ne/O, and Ar/O abundance ratios. The limit on [O III] 4363 A tightly constrains the oxygen abundance via the "direct" or Tc method, for the first time in all metallicity galaxy at z approx.2. We compare this result to several standard "bright-line" O abundance diagnostics, thereby testing these empirically calibrated diagnostics in situ. Finally, we explore the positions of lensed and unlensed galaxies in standard diagnostic diagrams, and explore the diversity of ionization conditions and mass-metallicity ratios at z=2.

Rigby, Jane↗

Rapid quantitative analysis of trace elements in plutonium alloys using a handheld laser-induced breakdown spectroscopy (LIBS) device coupled with chemometrics and machine learning

Here, we present the first reported quantification of trace elements in plutonium via a portable laser-induced breakdown spectroscopy (LIBS) device and demonstrate the use of chemometric analysis to enhance the handheld device's sensitivity and precision. Quantification of trace elements such as iron and nickel in plutonium metal via LIBS is a challenging problem due to the complex nature of the plutonium optical emission spectra. While rapid analysis of plutonium alloys has been demonstrated using portable LIBS devices, such as the SciAps Z300, their detection limits for trace elements are severely constrained by their achievable pulse power and length, light collection optics, and detectors. In this paper, analytical methods are evaluated as a means to circumvent the detection constraints. Three chemometric methods often used in analytical spectroscopy are evaluated; principal component regression, partial least-squares regression, and artificial neural networks. These models are evaluated based on goodness-of-fit metrics, root mean-squared error, and their achievable limits of detection (LoDs). Partial least squares proved superior for determining content of iron and nickel in plutonium metal, yielding LoDs of 15 and 20 ppm, respectively. These results of identifying the undesirable trace elements in plutonium components are critical for applications such as fabricating radioisotope thermoelectric generators or nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Solid-State Pathway Control via Reaction-Directing Heteroatoms: Ordered Pyridazine Nanothreads through Selective Cycloaddition

Nanothreads are one-dimensional nanomaterials comprised of a primarily sp 3 hydrocarbon backbone. They are typically formed through cycloaddition reactions induced by compression of small molecules to high pressures. Although nanothreads have been synthesized from a range of small molecule precursors (e.g., benzene, pyridine, aniline), the ability to control reaction pathways to produce atomically precise nanothreads with distinct chemical structures remains a difficult challenge. In this study, we show how heteroatoms incorporated within starting precursors can serve as “thread directing” groups by selecting for specific cycloaddition reaction pathways. By using a less-reactive diazine group within a six-membered aromatic ring, we successfully predict and synthesize the first carbon nanothread material derived from pyridazine (1,2-diazine, C 4 H 4 N 2 ). Compared with previous nanothreads, the synthesized polypyridazine, shows a predominantly uniform chemical structure with exceptional long-range order, allowing for structural characterization using vibrational spectroscopy and X-ray diffraction. The results demonstrate how thread-directing groups can be used for precise reaction pathway control and the formation of chemically precise nanothreads with a high degree of structural order.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Revealing Parallel Inter‐ and Intra‐Ligand Charge Transfer Dynamics in [Ru(L) 2 (dppz)] 2+ Molecular Lightswitch with N K‐Edge X‐Ray Absorption Spectroscopy

In photoactive metal complexes the localization of photoexcited charges dictates the site of chemical reactivity, but few studies measure the charge redistribution in these systems with spatial precision. Herein, we track the inter- and intra-ligand charge transfer processes that underpin light-driven charge separation in the well-studied “molecular lightswitch” [Ru(bpy) 2 dppz] 2+ (aqueous [Ruthenium II (2,2′-bipyridine)2(dipyrido[3,2-a:2′,3′-c]phenazine)] 2+ [Cl − ] 2 ) by probing the electronic structure of ligand nitrogen atoms in real-time using ultrafast X-ray absorption spectroscopy and first principles calculations. We confirm the localization of excited electron density on the phenazine N atoms of dppz and we newly identify two parallel electron transfer pathways to populate this state. Sub-70 fs electron transfer to the phenazine portion of dppz is observed and attributed to intra-ligand electron transfer following Ru-to-dppz metal-to-ligand charge transfer (MLCT) excitation. This fast charge transfer was not reported in prior ultrafast studies. The slower (ca. 2 ps) charge transfer reported extensively in time-resolved optical absorption and emission studies is reassigned here to inter-ligand electron “hopping” between nearly isoenergetic ligand moieties following Ru-to-bpy MLCT excitation. In conclusion, the results demonstrate much faster charge separation than previously identified in this well-studied system, highlighting how extended azaacene ligand motifs promote the competitive charge transfer processes needed to drive light-driven electron transfer chemistry.

Donor-acceptor systems↗

Spectrally and Radiometrically Stable Wide-Band on Board Calibration Source for In-Flight Data Validation in Imaging Spectroscopy Applications

The quality of the quantitative spectral data collected by an imaging spectrometer instrument is critically dependent upon the accuracy of the spectral and radiometric calibration of the system. In order for the collected spectra to be scientifically useful, the calibration of the instrument must be precisely known not only prior to but during data collection. Thus, in addition to a rigorous in-lab calibration procedure, the airborne instruments designed and built by the NASA/JPL Imaging Spectroscopy Group incorporate an on board calibrator (OBC) system with the instrument to provide auxiliary in-use system calibration data. The output of the OBC source illuminates a target panel on the backside of the foreoptics shutter both before and after data collection. The OBC and in-lab calibration data sets are then used to validate and post-process the collected spectral image data. The resulting accuracy of the spectrometer output data is therefore integrally dependent upon the stability of the OBC source. In this paper we describe the design and application of the latest iteration of this novel device developed at NASA/JPL which integrates a halogen-cycle source with a precisely designed fiber coupling system and a fiber-based intensity monitoring feedback loop. The OBC source in this Airborne Testbed Spectrometer was run over a period of 15 hours while both the radiometric and spectral stabilities of the output were measured and demonstrated stability to within 1% of nominal.

visible spectrometers↗

Development of Fast Decay-Energy Spectroscopy With Magnetic Microcalorimeters

Decay energy spectroscopy (DES) is an increasingly important radiometric technique arising from the unique thermal detection physics and the precision of low-temperature microcalorimetry. DES can enable high-precision analysis of very small amounts of radioactive material with simple and rapid sample preparation, making it a key new tool for nuclear safeguards, nuclear forensics, the improvement of nuclear data, measurements of absolute activity, and other applications. For problems in nuclear safeguards and nuclear forensics it is highly desirable to increase the count rates achievable in DES, while maintaining simple and rapid sample preparation. Here, in this report, we describe progress in a new project to achieve high count rates in DES by taking advantage of the physics of magnetic microcalorimetry. We describe the results of initial modeling and experiment to validate the idea, a sample fabrication technique suitable for nuclear materials laboratories, the preparation and initial tests of paramagnetic Au-Er alloy in thin foil form, and the development of a sensing coil geometry that will perform well with the increased-thickness sensor used in the new technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reversible long-range domain wall motion in an improper ferroelectric

Reversible ferroelectric domain wall movements beyond the 10 nm range associated with Rayleigh behavior are usually restricted to specific defect-engineered systems. Here, we demonstrate that such long-range movements naturally occur in the improper ferroelectric ErMnO 3 during electric-field-cycling. We study the electric-field-driven motion of domain walls, showing that they readily return to their initial position after having traveled distances exceeding 250 nm. By applying switching spectroscopy band-excitation piezoresponse force microscopy, we track the domain wall movement with nanometric spatial precision and analyze the local switching behavior. Phase field simulations show that the reversible long-range motion is intrinsic to the hexagonal manganites, linking it to their improper ferroelectricity and topologically protected structural vortex lines, which serve as anchor point for the ferroelectric domain walls. Our results give new insight into the local dynamics of domain walls in improper ferroelectrics and demonstrate the possibility to reversibly displace domain walls over much larger distances than commonly expected for ferroelectric systems in their pristine state, ensuring predictable device behavior for applications such as tunable capacitors or sensors.

Zahn, Manuel [Norwegian Univ. of Science and Techn↗

Absolute contrast estimation for soft X-ray photon fluctuation spectroscopy using a variational droplet model

Abstract X-ray photon fluctuation spectroscopy using a two-pulse mode at the Linac Coherent Light Source has great potential for the study of quantum fluctuations in materials as it allows for exploration of low-energy physics. However, the complexity of the data analysis and interpretation still prevent recovering real-time results during an experiment, and can even complicate post-analysis processes. This is particularly true for high-spatial resolution applications using CCDs with small pixels, which can decrease the photon mapping accuracy resulting from the large electron cloud generation at the detector. Droplet algorithms endeavor to restore accurate photon maps, but the results can be altered by their hyper-parameters. We present numerical modeling tools through extensive simulations that mimic previous x-ray photon fluctuation spectroscopy experiments. By modification of a fast droplet algorithm, our results demonstrate how to optimize the precise parameters that lift the intrinsic counting degeneracy impeding accuracy in extracting the speckle contrast. These results allow for an absolute determination of the summed contrast from multi-pulse x-ray speckle diffraction, the modus operandi by which the correlation time for spontaneous fluctuations can be measured.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling of transient interference phenomena in colinear laser spectroscopy

Colinear laser spectroscopy of fast atomic beams has been established as one of the main tools to perform precision experiments with atoms containing short-lived nuclei. Although highly sensitive, the spectral resolution of these techniques is typically limited to several MHz. Here, we study the use of transient interference phenomena to potentially improve the experimental resolution. Previous attempts to implement Ramsey-type measurements with fast beams were limited by the lack of understanding of the observed line shapes. Additionally, by using a simple model, we provide a satisfactory description of the previously observed line shapes and propose alternative experimental schemes to improve the resolution in fast ion-beam experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Single-molecule infrared spectroscopy with scanning tunneling microscopy

Probing vibrations at the single-molecule level is essential for achieving bond-specific chemical control in realistic heterogeneous environments. Here, we introduce a new measurement scheme that integrates frequency-tunable infrared excitation with scanning tunneling microscopy to characterize vibration-mediated nuclear motions of single molecules. We first validated the technique by monitoring the infrared-induced rotation of the ethynyl radical and then applied it to mapping pyrrolidine’s conformational dynamics. The resulting broadband spectra captured fundamental vibrational modes together with rich overtone and combination bands inaccessible by conventional methods, which we confirmed with isotopic substitutions. Density functional theory calculations showed that delocalized modes coupled with pyrrolidine ring puckering drive the structural transition, revealing altered selection rules compared with traditional infrared spectroscopy. Here, this new experimental platform enables molecular vibrations and transformations to be probed with atomic precision.

Liang, Kangkai [University of California, San Dieg↗

Ultrasonic Resonance Techniques for Materials Research

Mechanical resonances are directly related to the physical behavior of a system at the bulk and microscopic levels. In materials science, resonant ultrasound spectroscopy (RUS) has long been a preferred nondestructive method to study mechanical resonances of solids and precisely measure quantitative material properties, namely elasticity. In recent years, advances in computational power and hardware have enabled RUS to be relevant for an increasing range of applications, such as advanced manufacturing. An extension of this technique, nonlinear RUS (NRUS), has been demonstrated to provide unmatched sensitivity to early-stage damage. NRUS was originally developed to probe geologic materials but has become a vital tool in nondestructive evaluation and materials research, offering a powerful means of quantifying and characterizing microstructural nonlinearity in a broad range of materials. This review summarizes recent developments and growth opportunities in RUS and NRUS techniques, modeling, and applications across a wide range of material systems including metals, composites, geomaterials, and explosives.

36 MATERIALS SCIENCE↗

Validation of stratospheric ozone observed by the Atmospheric Trace Molecule Spectroscopy (ATMOS) experiment during 1992

Measurements of stratospheric ozone were made by the Atmospheric Trace Molecule Spectroscopy (ATMOS) experiment from onboard the Space Shuttle during the period 8-16 April 1992. The precision and accuracy of the measurements are discussed in the context of establishing the accuracy and compatibility of the measurements relative to other space-based measurements of ozone. Coincident measurements were obtained from the Stratospheric Aerosol and Gas Experiment (SAGE) 2 instrument onboard the Earth Radiation Budget Satellite (ERBS) and three instruments, the Microwave Limb Sounder (MLS), the Cryogenic Limb Array Etalon Spectrometer (CLAES), the Halogen Occultation Experiment (HALOE) onboard the Upper Atmospheric Research Satellite (UARS). Three of the instruments, ATMOS, SAGE-2 and MLS are demonstrated to be consistent to within +10% over the altitude range between 100 hPa and 0.5 hPa (approximately 20 to 60 km), with ATMOS and MLS displaying a zero mean bias and a root mean square deviation (rms) of 3% and SAGE-2 displaying an essentially systematic bias of -5% over the majority of the altitude range, except for below 30 hPa where SAGE-2 displays a large positive systematic bias due to the effect of the aerosol attenuation resulting from the Mt. Pinatubo volcanic eruption in 1991. The comparison with HALOE indicates that ozone levels observed by ATMOS are systematically higher than HALOE by 5 to 25% with a clear gradient in the differences; in contrast the comparison with CLAES displays differences of as much as + 30% with no obvious systematic scaling possible. Comparisons are evaluated in two separate schemes, by geographical coincidence and through zonal averages which illustrate the limitations of both schemes. Latitudinal and longitudinal variation are used to assess the sensitivity of the ATMOS measurements and to confirm the precision and accuracy, which should be less than 4% and 10% respectively.

Abrams, M. C.↗

Scientific Objectives of the Mars Surveyor 2001 Gamma-Ray Spectrometer

The Gamma-Ray Spectrometer (GRS) is one of the instruments on the Mars Surveyor 2001 Orbiter, which is part of NASA's Mars-Surveyor program. The GRS is really an instrument suite consisting of the GRS, a neutron spectrometer (NS), and a high-energy neutron detector (FIEND). Each of these instruments/sensors are remotely mounted at different locations on the spacecraft and connect to a central electronics box. The GRS will achieve global mapping of the elemental composition of the surface and the abundance of hydrogen in the shallow subsurface. It is an updated design using the same technology as the lost Mars Observer mission. The Martian surface is continuously bombarded by cosmic ray particles; their interactions with the constituents of the soil produces nuclear reaction cascades with fast neutrons being the main secondaries. Those neutrons interact in turn with the nuclei of the elements that make up the soil and they eventually get slowed to thermal energies. In this process they leave the nuclei in an excited state that decays via the emission of characteristic gamma rays. All these processes are precisely known and have been simulated by means of numerical models. Thus, remote gamma-ray spectroscopy is a useful method for quantitatively measuring the geochemical composition of the surface down to a few tens of g/sq cm. Additional information is contained in original extended abstract.

Boynton, W. V.↗

Euclid Mission: Mapping the Geometry of the Dark Universe. Mission and Consortium Status

Euclid concept: (1) High-precision survey mission to map the geometry of the Dark Universe (2) Optimized for two complementary cosmological probes: (2a) Weak Gravitational Lensing (2b) Baryonic Acoustic Oscillations (2c) Additional probes: clusters, redshift space distortions, ISW (3) Full extragalactic sky survey with 1.2m telescope at L2: (3a) Imaging: (3a-1) High precision imaging at visible wavelengths (3a-2) Photometry/Imaging in the near-infrared (3b) Near Infrared Spectroscopy (4) Synergy with ground based surveys (5) Legacy science for a wide range of in astronomy

dark energy↗