Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Powered By”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Modeling the AC Power Flow Equations with Optimally Compact Neural Networks: Application to Unit Commitment

Nonlinear power flow constraints render a variety of power system optimization problems computationally intractable. Emerging research shows, however, that the nonlinear AC power flow equations can be successfully modeled using neural networks. These neural networks can be exactly transformed into mixed integer linear programs and embedded inside challenging optimization problems, thus replacing nonlinearities that are intractable for many applications with tractable piecewise linear approximations. Such approaches, though, suffer from an explosion of the number of binary variables needed to represent the neural network. Accordingly, this paper develops a technique for training an "optimally compact'' neural network, i.e., one that can represent the power flow equations with a sufficiently high degree of accuracy while still maintaining a tractable number of binary variables. We demonstrate the use of this neural network as an approximator of the nonlinear power flow equations by embedding it in the AC unit commitment problem, transforming the problem from a mixed integer nonlinear program into a more manageable mixed integer linear program. We use the 14-, 57-, and 89-bus networks as test cases and compare the AC-feasibility of commitment decisions resulting from the neural network, DC, and linearized power flow approximations. Our results show that the neural network model outperforms both the DC and linearized power flow approximations when embedded in the unit commitment problem. The neural network formulation most often selects a feasible unit commitment schedule, and furthermore, it only s

AC power flow↗

REJUVENATING THE MATTER POWER SPECTRUM. III. THE COSMOLOGY SENSITIVITY OF GAUSSIANIZED POWER SPECTRA

It was recently shown that applying a Gaussianizing transform, such as a logarithm, to the nonlinear matter density field extends the range of useful applicability of the power spectrum by a factor of a few smaller. Such a transform dramatically reduces nonlinearities in both the covariance and the shape of the power spectrum. Here, analyzing Coyote Universe real-space dark-matter density fields, we investigate the consequences of these transforms for cosmological parameter estimation. The power spectrum of the log-density provides the tightest cosmological parameter error bars (marginalized or not), giving a factor of 2-3 improvement over the conventional power spectrum in all five parameters tested. For the tilt, n{sub s} , the improvement reaches a factor of five. Similar constraints are achieved if the log-density power spectrum and conventional power spectrum are analyzed together. Rank-order Gaussianization seems just as useful as a log transform to constrain n{sub s} , but not other parameters. Dividing the overdensity by its dispersion in few-Mpc cells, while it diagonalizes the covariance matrix, does not seem to help with parameter constraints. We also provide a code that emulates these power spectra over a range of concordance cosmological models.

79 ASTRONOMY AND ASTROPHYSICS↗

Laser power meters as an X-ray power diagnostic for LCLS-II

For the LCLS-II X-ray instruments, laser power meters are being developed as compact X-ray power diagnostics to operate at soft and tender X-ray photon energies. These diagnostics can be installed at various locations along an X-ray free-electron laser (FEL) beamline in order to monitor the transmission of X-ray optics along the beam path. In addition, the power meters will be used to determine the absolute X-ray power at the endstations. Here, thermopile power meters, which measure average power, and have been chosen primarily for their compatibility with the high repetition rates at LCLS-II, are evaluated. Here, a number of characteristics in the soft X-ray range are presented including linearity, calibrations conducted with a photodiode and a gas monitor detector as well as ultra-high-vacuum compatibility tests using residual gas analysis. The application of these power meters for LCLS-II and other X-ray FEL sources is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as a Type-5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type-5 WTG interfaces with the electric grid via a synchronous generator driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type-5 WTG in a power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration shows that a Type-5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to a Type-3 WTG in high-wind conditions. The developed model provides further insight into how Type-5 WTGs can benefit the smooth transition to power systems with high integration levels of inverter-based resources.

grid strength↗

Equivalent Test Bed in PSCAD and PSLF for Studying Advanced Power Systems Controller Performance

With increasing popularity of sustainable energy resources, research on power electronic-based renewable generation modeling is gaining impetus to enhance reliability of electric grids with high penetrations of renewable energy. A set of generic and public models for renewable energy are available in commercial positive sequence power system simulation software. However, advanced controller models applicable for renewable resources are typically not included in these tools. To ensure the integrity of the newly developed controller models for renewables in positive sequence simulators for large power systems, it is necessary to validate the dynamic performance of the proposed model with detailed electromagnetic models. This paper creates an equivalent test bed in PSCAD and PSLF for validating the performance of advanced controllers associated with renewable energy sources. To demonstrate the usefulness of the test-bed, a user-defined synthetic inertia (SI) controller model was developed in PSLF and validated through the proposed test bed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing Grid Resilience during Wildfires in Socioeconomic Vulnerable Regions using Powered and Non-Powered Hydro Dams

In many regions around the world, wildfires have become a growing threat, exacerbated by factors such as climate change, droughts, and urban sprawl. These wildfires often wreak havoc on power infrastructure, leading to extended power outages, which can have devastating consequences for communities, especially in socioeconomically vulnerable areas. Ensuring grid resiliency in the face of these challenges is of paramount importance. One innovative approach to mitigating the impact of wildfires on the power grid is the utilization of hydropower facilities including both powered and non-powered hydro dams. While powered hydro dams along with additional infrastructure like energy storage and solar photovoltaic can provide resilience during wildfire-related outages, non-powered dams, originally constructed for purposes other than electricity generation, also offer a unique opportunity to bolster grid resilience. In this paper, we aim to explore the efficacy of hydro-dams in general to provide resiliency during wildfire-induced outages.

Wildfires, Resilience, Grid Resiliency, Hydropower↗

Alternatives to MARVEL Power Conversion -- Comparison of Stirling Engine Thermal Efficiency and Design to Other Power Conversion Cycles

PRESENTATION for CONFERENCE PAPER: The Microreactor Applications, Research, Validation, and Evaluation (MARVEL) Reactor is a small liquid-metal thermal reactor that will be built at the Idaho National Laboratory to demonstrate design and operating processes for microreactors, microgrid integration, and process heat applications. Power conversion in the MARVEL design is provided by Stirling engines, which have disadvantages in nuclear environments. Compared to Stirling engine performance, some alternative power cycles can increase power production when coupled to a liquid-metal thermal reactor. In this paper, the thermal efficiency of MARVEL’s power production with Stirling engines is compared to the thermal efficiency of power production with MARVEL and alternative power cycles. Those cycles include a superheated Rankine cycle, open and closed Brayton cycles, and a supercritical carbon dioxide cycle. All cycles (except the Stirling engines) were modeled with an intermediate helium loop to meet MARVEL’s principal design criteria. All models are simple designs with conservative assumptions for consistent comparison. Detailed optimization will depend largely on reactor location and application, and the relative merit of each cycle is discussed for different environmental conditions. The study informs significant early decisions on power cycle design and economics for deployment of advanced microreactors as they move from theory and concept to execution.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Active Power Controls from Wind Power: Bridging the Gaps

This paper details a comprehensive study undertaken by the National Renewable Energy Laboratory, Electric Power Research Institute, and the University of Colorado to understand how the contribution of wind power providing active power control (APC) can benefit the total power system economics, increase revenue streams, improve the reliability and security of the power system, and provide superior and efficient response while reducing any structural and loading impacts that may reduce the life of the wind turbine or its components. The study includes power system simulations, control simulations, and actual field tests using turbines at NREL's National Wind Technology Center (NWTC). The study focuses on synthetic inertial control, primary frequency control, and automatic generation control, and analyzes timeframes ranging from milliseconds to minutes to the lifetime of wind turbines, locational scope ranging from components of turbines to large wind plants to entire synchronous interconnections, and additional topics ranging from economics to power system engineering to control design.

17 WIND ENERGY↗

Power Sector Transformation Pathways: Exploring Objectives, Factors, and Technology Innovations to Inform Power Sector Pathway Decisions

The power and heating sectors are responsible for around 30% of global CO2 emissions and this share is likely to grow as countries move towards electrification of the transportation and building sectors. Therefore, enabling forward-thinking, long term strategies in the power sector is a crucial area for international collaboration and support. The rapid transition of power systems toward modern, low-carbon pathways and technologies will be necessary to meet key climate goals while also enabling other critical objectives such as economic development, energy access, and energy system resiliency, among others. Many developed and developing countries are well-poised to champion power sector transformation (PST), however, further support is needed to identify pathways and implement critical near and long-term actions. To address this need, the Low Emission Development Strategies Global Partnership (LEDS GP) together with an expert team including Agora Energiewende, Energy Innovation, European Climate Foundation, Fraunhofer Institute for Systems and Innovation Research , Prayas Energy Group and LEDS Latin America and Caribbean Platform, developed a framework identifying four key pathways that can be integrated and combined to support low-carbon PST. These four pathways are: (1) Distributed Energy Resource Revolution, (2) Bulk Power Transformation, (3) Transmission and Distribution Interactivity, and (4) Distributed Transactional Future. To support exploration of pathways, this study examines PST objectives and factors that may lead countries or jurisdictions to place a greater relative emphasis on certain pathways as well as a framework and complementary tool for considering the emphasis in a hands on manner. The report provides case studies on application of the approach to bring life to the topic. The case studies include Haiti, Kenya, Mexico, Southeast Asia, and the European Union, among others. The report also presents actions to-be-taken in the near-, medium- and long-term to support the realization of pathways and long-term transformation of the power sector. The report, together with a complementary spreadsheet tool developed under the effort, can be used to enable stakeholder engagement and visioning for the power sector over the long-term, taking into account key factors and potential innovations. It can also be used to understand and inform relevant analysis tools and models based on which pathways are emphasized, and to identify key actions in the near- and medium-term to avoid lock-in of carbon-intensive technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hydrogen and Power Co-Production Using Direct sCO 2 Power Cycles

This report presents the techno-economic analysis (TEA) results of integrating a modified autothermal reforming (ATR) hydrogen (H 2 ) production plant with a natural gas-fired, utility-scale power plant based on the direct supercritical carbon dioxide (sCO 2 ) power cycle. In this study, the H 2 production and the power plant are fully integrated in terms of heat, fuel, and carbon capture and storage (CCS). The ATR process has significant waste heat available for heat integration with a direct-fired sCO 2 power plant that benefits the power plant efficiency. The off-gas stream from the modified ATR process is primarily carbon dioxide (CO 2 ), carbon monoxide (CO), and residual H 2 . As supplemental fuel, it has beneficial heating value in the CO and H 2 that can be used in the direct sCO 2 power cycle. Finally, the direct sCO 2 power plant can isolate the CO 2 produced at the facility for CCS.

08 HYDROGEN↗

The Power Curve Working Group's Assessment of Wind Turbine Power Performance Prediction Methods

A wind turbine power curve is often only strictly valid for a subset of all atmospheric conditions (i.e., the inner range), while wind turbines also operate in other scenarios (i.e., the outer range). Hence, modeling the power output in real-world conditions is a fundamental challenge. For example, the power deviation matrix (PDM) in Figure 1 displays an overprediction of power production using a reference power curve when wind speed (WS) and turbulence intensity (TI) are both low. Many experts use the PDM approach to observe any systematic bias in power curves and correct this in energy yield models. The mission of the Power Curve Working Group (PCWG) is to bring together wind industry stakeholders to help identify, validate, and develop ways to improve modeling of wind turbine performance in all atmospheric conditions.

17 WIND ENERGY↗

Orion Power Transfer: Impacts of a Battery-on-Bus Power System Architecture

The Orion Multi-Purpose Crew Vehicle (MPCV) has the capability to transfer power to a co-manifested payload (CPL) during transit from low-Earth orbit to the lunar vicinity. This paper discusses a time-phased parametric power analysis to determine the Orion power transfer capability limit. Charge and discharge curves were generated for various power transfer conditions and measured against various minimum system voltage limits. The Orion electrical power system (EPS) utilizes an unregulated bus architecture, which has important implications when the system is operating under very high load demand conditions, such as during power transfer. This analysis highlights three important effects of this architecture. First, increasing load demand decreases the maximum state of charge (SOC) the batteries can reach when charging. Second, increasing load demand also decreases the allowable battery depth of discharge. These two together can significantly reduce the effective useable capacity of the batteries. Finally, low battery voltage decreases the power generation of the solar arrays. This can lead to significantly longer recharge times or even push the system out of energy balance. These effects have important implications for mission design and vehicle operations and must be accounted for when conducting sizing and design of an unregulated spacecraft EPS.

Electrical Power System↗

Thermal Analysis of the Advanced Modular Power Systems (AMPS) Power Electronic Modules

In an effort to transform future space power system architectures and operations, the Advanced Modular Power Systems (AMPS) project is currently developing an interface standard for power electronic modules to enable modular architectures for space power systems. Each architecture would consist of one or more modular electronic units (MEU) that would comprise of a tailored combination of modules. The standard currently comprises modules enabling switchgear, power conversion, and data interfacing. The objective of the AMPS project is to enable the modularity and interchangeability of different architectures using these standardized modules in hopes of reducing complexity and cost, increasing inherent redundancy and reliability, and minimizing power system redesign for future programs. A key enabler to these future modular architectures will be the thermal management system, which has to contend with acquiring heat from the electronics modules at the card level and then transporting that heat to the radiator of the larger system. The focus of this paper, therefore, will be the thermal design and analysis of multiple AMPS power electronics modules and the development of their thermal-vacuum test.

Modular Power Electronics↗

Wireless power charging using point of load controlled high frequency power converters

An apparatus for wirelessly charging a battery of an electric vehicle is provided with a point of load control. The apparatus includes a base unit for generating a direct current (DC) voltage. The base unit is regulated by a power level controller. One or more point of load converters can be connected to the base unit by a conductor, with each point of load converter comprising a control signal generator that transmits a signal to the power level controller. The output power level of the DC voltage provided by the base unit is controlled by power level controller such that the power level is sufficient to power all active load converters when commanded to do so by any of the active controllers, without generating excessive power that may be otherwise wasted.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BICMOS power detector for pulsed Rf power amplifiers

A BiCMOS power detector for pulsed radio-frequency power amplifiers is proposed. Given the pulse waveform and a fraction of the power amplifier's input or output signal, the detector utilizes a low-frequency feedback loop to perform a successive approximation of the amplitude of the input signal. Upon completion of the successive approximation, the detector returns 9-bits representing the amplitude of the RF input signal. Using the pulse waveform from the power amplifier, the detector can dynamically adjust the rate of the binary search operation in order to return the updated amplitude information of the RF input signal at least every 1ms. The detector can handle pulse waveform frequencies from 50kHz to 10MHz with duty cycles in the range of 5- 50% and peak power levels of -10 to 10dBm. The signal amplitude measurement can be converted to a peak power measurement accurate to within ±0.6dB of the input RF power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant: Preprint

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators has attracted substantial attention in power systems research; however, the limited over-current capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as Type-5 wind turbine generator (WTG), offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high penetration levels of renewable generation. A Type-5 WTG interfaces to the electric grid via a synchronous generator (SG) driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation and the generator shaft remains synchronous to the grid. This paper developed and tested a high-fidelity model of Type-5 WTG under power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration showed that a Type-5 WTGs inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to Type-3 WTG in high wind conditions. The developed model also provides further insight on how Type-5 WTGs can benefit the smooth transition to power systems with high integration level of inverter-based resources.

grid strength↗

Alternatives to MARVEL Power Conversion – Comparison of Stirling Engine Thermal Efficiency and Design to other Power Conversion Cycles

The Microreactor Applications, Research, Validation, and Evaluation (MARVEL) Reactor is a small liquid-metal thermal reactor that will be built at the Idaho National Laboratory to demonstrate design and operating processes for microreactors, microgrid integration, and process heat applications. Power conversion in the MARVEL design is provided by Stirling engines, which have disadvantages in nuclear environments. Compared to Stirling engine performance, some alternative power cycles can increase power production when coupled to a liquid-metal thermal reactor In this paper, the thermal efficiency of MARVEL’s power production with Stirling engines is compared to the thermal efficiency of power production with MARVEL and alternative power cycles. Those cycles include a superheated Rankine cycle, open and closed Brayton cycles, and a supercritical carbon dioxide cycle. All cycles (except the Stirling engines) were modeled with an intermediate helium loop to meet MARVEL’s principal design criteria. All models are simple designs with conservative assumptions for consistent comparison. Detailed optimization will depend largely on reactor location and application, and the relative merit of each cycle is discussed for different environmental conditions. The study informs significant early decisions on power cycle design and economic

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Guest Editorial: Control interactions in power electronic converter dominated power systems

The modern power systems have undergone significant transformations at the generation, transmission, distribution, and utilization levels due to the remarkable advancements in power electronic converter technology. Power electronic converters are now prevalent in various applications, including wind turbine converters, photovoltaic inverters, flexible AC transmission systems (FACTS) and high-voltage DC (HVDC) converters, distributed generators, microgrids, and electric vehicles. The widespread adoption of power electronic converters has revolutionized the power system by providing fast and flexible controllability. However, their unique characteristics, such as fast response, multi-time scale dynamics, reconfigurable control, and varying sizes and capacities, have introduced new stability challenges, fundamentally altering the dynamics of modern power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗