Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power system restoration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Scaling a Smart Sub-metered Electrical Data Solution for the Center

Currently, there is no single Center-level point solution that enables facility systems data to be collected and stored from buildings on-site, on-demand, and through a faceted search capability that would enable the cultivation of deeper insights into incipient facility-related issues that would otherwise be overlooked. Such insights would represent a powerful and very valuable tool to aid in data-driven decision making and informing actionable steps for remediation and resolution of these problems. Access to electrically sub-metered data via hardware upgrades is in the process of being restored for Building N232, Sustainability Base, but this is only the first step. The native software capabilities that were originally part of a proposed Agencywide Smart Center initiative project can unlock the ability to access actionable insights. This work would also nicely complement many initiatives that are actively being pursued, under consideration, or pending submission to this same call at the Center. This project is poised to support an NRSAA with Verdigris Technologies, as well as in support of an Agencywide Smart Center initiative. Monitoring electrical consumption usage at the most granular level in Bldg. N232 will be instrumental in accurately quantifying potential utility costs and investments, and monitoring usage trends, as it is being converted into hoteling spaces, to help. This will also help with determining how the capability can scale more broadly across the Center and Agency at large.

Rodney Alexander Martin↗

Scaling a Smart Sub-metered Electrical Data Solution for the Center

Currently, there is no single Center-level point solution that enables facility systems data to be collected and stored from buildings on-site, on-demand, and through a faceted search capability that would enable the cultivation of deeper insights into incipient facility-related issues that would otherwise be overlooked. Such insights would represent a powerful and very valuable tool to aid in data-driven decision making and informing actionable steps for remediation and resolution of these problems. Access to electrically sub-metered data via hardware upgrades is in the process of being restored for Building N232, Sustainability Base, but this is only the first step. The native software capabilities that were originally part of a proposed Agencywide Smart Center initiative project can unlock the ability to access actionable insights. This work would also nicely complement many initiatives that are actively being pursued, under consideration, or pending submission to this same call at the Center. This project is poised to support an NRSAA with Verdigris Technologies, as well as in support of an Agencywide Smart Center initiative. Monitoring electrical consumption usage at the most granular level in Bldg. N232 will be instrumental in accurately quantifying potential utility costs and investments, and monitoring usage trends, as it is being converted into hoteling spaces, to help. This will also help with determining how the capability can scale more broadly across the Center and Agency at large.

Rodney Alexander Martin↗

FIDVR Capability of Hybrid Grid-Forming PV Power Plants During Feeder Restoration

Grid-forming inverters must optimally transfer power from dc-coupled photovoltaic arrays and batteries into an ac grid. Further, they must be able to restore single-phase induction motors (SPIMs) and withstand fault-induced delayed voltage-recovery (FIDVR) events. These resilience and reliability challenges are addressed here by: (i) engineering a controller to optimally operate dc-coupled hybrid resources; (ii) modeling residential air-conditioning compressors for restoration/FIDVR studies; and (iii) analyzing SPIM thermal-relay performance under limited inverter currents and designing an electronic protection for stalled SPIMs. Furthermore, these contributions are demonstrated via electromagnetic-transient simulations and can be helpful to understand recommendations by the North American Electric Reliability Corporation.

14 SOLAR ENERGY↗

Cybersecurity Challenges in Low-Inertia Power-Electronics-Dominated Grids

Here, the low inertia characteristics of the power electronics dominated grid (PEDG) introduces challenges while restoring voltage and frequency to their nominal values. These stability challenges create new cybersecurity vulnerabilities that are not thoroughly discussed in the literature. Cyber events such as false data injection (FDI), denial of service (DoS), man-in-the-middle attacks, stealthy attacks, and advanced persistent threats target PEDG to disrupt grid stability or gain financial benefits. The low inertia of PEDG (< 2s) compared to traditional grids (~10s) exacerbates these vulnerabilities. In response to stealthy attacks on state variables that supervisory layers cannot detect until significant harm occurs, the low inertia characteristics of PEDG offer substantial stealthy attack surfaces. To counteract such threats, PEDG must be equipped with ultra-fast real-time anomaly detection system and trajectory prediction mechanism to achieve effective cyberattack resiliency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mitigating Data Center Impact on Grid Stability: A Coordinated Control Strategy Using Verrus StabiliGrid Architecture

Large data centers, which now represent a significant and growing share of the total U.S. grid load, can inadvertently destabilize the electrical grid when they disconnect simultaneously during brief voltage disturbances. The July 10, 2024, Eastern Interconnection incident, in which a sub-100-millisecond transmission fault triggered the cascading loss of approximately 1,500 MW of data center load, illustrates this vulnerability. While commercial battery energy storage systems (BESS) deployed in data centers provide device-level fault ride-through per IEEE 1547, they lack coordination with facility protection logic and uninterruptible power supplies (UPS), limiting their effectiveness as grid-stabilizing assets. This report presents the Verrus StabiliGrid architecture, a coordinated control framework that integrates BESS, UPS, and point-of-interconnection (POI) protection settings to enable data centers to ride through both undervoltage and overvoltage grid contingencies without disconnecting. The four-step strategy encompasses: (1) high-resolution power quality monitoring to detect the grid state during events such as undervoltage, overvoltage, underfrequency, and overfrequency; (2) POI protection settings that allow for extended ride-through and grid-connected operation during grid contingencies; (3) grid state-driven autonomous dispatch of assets to improve grid resilience by reducing power draw during undervoltage or absorbing more power during overvoltage events; and (4) coordinated post-recovery dispatch of data center assets to restore firm load to pre-contingency levels. Validated through controller-hardware-in-the-loop (C-HIL) simulations at the National Laboratory of the Rockies, results show grid import restoration to pre-fault levels within 100 milliseconds of voltage recovery. This work advances the ability of data centers to transition from passive, disturbance-sensitive loads to active participants in grid stability, a capability increasingly required by emerging NERC and ERCOT regulatory frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilience Evaluation and Enhancement for Island City Integrated Energy Systems

Extreme natural hazards, such as hurricanes or earthquakes, have a high probability of threatening energy supply security and causing high-order contingencies to island city-integrated energy systems (IC-IESs). To better evaluate and enhance resilience, a novel approach is proposed in this work for IC-IESs. The resilience of an IC-IES is analyzed from both the system level and the component level. At the system level, the impacts of extreme natural disasters are quantified. At the component level, the importance of individual components is analyzed through pre-failure and post-failure indices. The pre-failure index identifies the system’s weak links before an energy interruption, and the post-failure index determines the optimal repair strategy to restore the service. The proposed indices are solved by the impact increment method (IIM), which significantly improves computational efficiency without much affecting result accuracy. Numerical simulation studies are conducted on the modified Barry Island IES and IES E123-G48-H32 test systems. Furthermore, the results validate the effectiveness of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Examination of the Extreme Cold Weather Event Affecting the Power System in Texas - February 2021 [Slides]

This presentation examines the extreme cold weather event that affected the power system in Texas in February 2021. The Texas load-shedding events were caused by a combination of record-high demand and cold weather issues that reduced the output from all types of generation. While some wind turbines were shutting down due to cold temperatures and icing and a lack of cold-weather packages, hourly wind output was accurately predicted. Extreme weather events historically drive grid reliability. Additional examination of more extreme events is needed to understand their impacts on the power system. As a national lab, NREL has the capabilities and facilities to help the industry address these types of challenges. NREL also has significant simulation and analysis capabilities (such as NAERM) that can help understand the impacts of extreme events. NREL also developed the Advanced Research on Integrated Energy Systems (ARIES) Research Platform, which enables evaluation of technologies that smooth grid operations during events like this.

17 WIND ENERGY↗

Accelerating Resilience of the Community through Holistic Engagement and use of Renewables (ARCHER) Planning Framework

The primary objective of the Accelerating Resilience of the Community through Holistic Engagement and Use of Renewables (ARCHER) initiative was to identify and incorporate the unique variations in energy burden, social vulnerability, living conditions, and access to essential services that differ across communities. By accounting for these localized factors—down to the neighborhood level—the project supports more targeted and effective investments in community resilience. The framework seeks to establish practical planning guidance, methods, and performance measures for community energy resilience, integrate community-level and electric utility system resilience planning, and assess its effectiveness through comparison with conventional and operational planning approaches. A key component of the project was its data exchange platform, which is used to evaluate and demonstrate the tools, methodologies, and planning approaches developed through ARCHER. This open-source platform enables developers and vendors of distribution and outage management systems to build upon the research by incorporating its concepts into their own tools and workflows. This capability is enabled by the transparent availability of data, functional requirements, and the underlying information model. The project yielded several important insights. First, meaningful engagement with communities is essential to achieving comprehensive resilience outcomes. Second, resilience planning is most effective when electric grid considerations and broader community needs are addressed in a coordinated manner. Third, the use of platforms that allow for real-time input from communities can enhance utility responsiveness during restoration activities. Fourth, a structured and systematic planning approach can successfully translate ARCHER concepts into practice. Fifth, the development of an integrated metric that reflects both grid performance and community impacts provides a more holistic basis for evaluating resilience. Finally, incorporating community engagement and equity considerations into grid operations is critical, particularly during severe weather events that result in extended outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Depolarization self-compensation in high-power lasers enabled by a mid-cavity quartz rotator

Depolarization from thermal stress remains a major limitation in high-average-power laser amplifiers, often addressed by complex, costly active methods or by using magneto-optical effects to restore the polarization. We demonstrate a passive polarization self-compensation technique using a quartz rotator in a relay-imaged, multi-pass amplifier geometry. A detailed theoretical framework is presented and validated experimentally, showing a 47 × reduction in depolarized light in a relay-imaged 4-pass cavity. This approach employs a high-damage-threshold, reciprocal material and avoids the use of polarizers or active controls, thereby simplifying system design and reducing costs. Scalability is discussed for realistic inertial fusion energy driver designs, including effectiveness for broadband lasers and thick gain media.

Batysta, František [Lawrence Livermore National La↗

Spinoff 2005

Topics covered include: Lighting the Way for Quicker, Safer Healing; Discovering New Drugs on the Cellular Level; Hydrogen Sensors Boost Hybrids; Today s Models Losing Gas?; 3-D Highway in the Sky; Popping a Hole in High-Speed Pursuits; Monitoring Wake Vortices for More Efficient Airports; From Rockets to Racecars; All-Terrain Intelligent Robot Braves Battlefront to Save Lives; Keeping the Air Clean and Safe--An Anthrax Smoke Detector; Lightning Often Strikes Twice; Technology That's Ready and Able to Inspect Those Cables; Secure Networks for First Responders and Special Forces; Space Suit Spins; Cooking Dinner at Home--From the Office; Nanoscale Materials Make for Large-Scale Applications; NASA s Growing Commitment: The Space Garden; Bringing Thunder and Lightning Indoors; Forty-Year-Old Foam Springs Back With New Benefits; Experiments With Small Animals Rarely Go This Well; NASA, the Fisherman's Friend; Crystal-Clear Communication a Sweet-Sounding Success; Inertial Motion-Tracking Technology for Virtual 3-D; Then Why Do They Call Earth the Blue Planet?; Valiant 'Zero-Valent' Effort Restores Contaminated Grounds; Harnessing the Power of the Sun; Water and Air Measures That Make 'PureSense'; Remote Sensing for Farmers and Flood Watching; Pesticide-Free Device a Fatal Attraction for Mosquitoes Making the Most of Waste Energy Washing Away the Worries About Germs Celestial Software Scratches More Than the Surface A Search Engine That's Aware of Your Needs Fault-Detection Tool Has Companies 'Mining' Own Business; Software to Manage the Unmanageable; Tracking Electromagnetic Energy With SQUIDs; Taking the Risk Out of Risk Assessment; Satellite and Ground System Solutions at Your Fingertips; Structural Analysis Made 'NESSUSary'; Software of Seismic Proportions Promotes Enjoyable Learning; Making a Reliable Actuator Faster and More Affordable; Cost-Cutting Powdered Lubricant NASA s Radio Frequency Bolt Monitor: A Lifetime of Spinoffs Going End to End to Deliver High-Speed Data; Advanced Joining Technology: Simple, Strong, and Secure; Big Results From a Smaller Gearbox; Low-Pressure Generator Makes Cleanrooms Cleaner; and The Space Laser Business Model.

Source record↗

Design of Muon Campus Full Flow Purifier for Varying Operational Conditions and Horizontal Shipping

The Muon Campus g-2 experiment requires stable helium supply at 5 K to the superconducting magnet. After a short period of operations, the pressure drop across the magnet’s flow supply valve increases due to impurities, resulting in reduced excess capacity concurrently with drop in refrigerator expander efficiency. This requires periodic powering down of the magnet to allow for helium valve “flush” to remove accumulated contamination at the valve as well as warming up the refrigerator expander above 80 K to release contamination. A “mobile” purifier is used for this periodic process but only at 10% of total refrigerator flow such that the purification process is extended. After long duration of running, this purification procedure is required almost every two weeks to restore proper liquid helium supply to the magnet. This shows requirement for full flow purifier which can purify impurities from entire Muon Campus refrigerator system and mitigate existing impurities issue and associated experiment downtime.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Preliminary Aerodynamic Measurements from a Magnetic Suspension and Balance System in a Low-Speed Wind Tunnel

An existing Magnetic Suspension and Balance System (MSBS) has been restored to operation in a small (octagonal test section, 6-inches across flats) low-speed wind tunnel as the first phase of a project to develop new dynamic test capabilities for planetary entry capsules at supersonic speeds. The MSBS and associated wind tunnel were originally designed and built at MIT and were subsequently relocated to NASA Langley Research Center. NASA ceased operations of the system in the late 1990s and it was transferred to Old Dominion University where it had been mothballed until the present work started in 2015. All-new position sensor electronics, electromagnet power supplies, digital controller, and other hardware have been developed, leading to more efficient and reliable operation. Important features of the new hardware will be briefly described. Wind tunnel testing has commenced, focusing first on static aerodynamics of re-entry capsule shapes. Some preliminary results will be reviewed, including comparison to reference data. The proposed extension to dynamic stability testing, using a variety of free-to-pitch approaches will be described. Finally, the preliminary design of the all-new Phase II (supersonic) system will be briefly outlined.

Schoenenberger, Mark↗

Restoration and Reexamination of Apollo Lunar Dust Detector Data from Original Telemetry Files

We are recovering the original telemetry (Figure I) from the Apollo Dust, Thermal, Radiation Environment Monitor (DTREM) experiment, more commonly known as the Dust Detector, and producing full time resolution (54 second) data sets for release through the Planetary Data System (PDS). The primary objective of the experiment was to evaluate the effect of dust deposition, temperature, and radiation damage on solar cells on the lunar surface. The monitor was a small box consisting of three solar cells and thermistors mounted on the ALSEP (Apollo Lunar Surface Experiments Package) central station. The Dust Detector was carried on Apollo's 11, 12, 14 and 15. The Apollo 11 DTREM was powered by solar cells and only operated for a few months as planned. The Apollo 12, 14, and 15 detectors operated for 5 to 7 years, returning data every 54 seconds, consisting of voltage outputs from the three solar cells and temperatures measured by the three thermistors. The telemetry was received at ground stations and held on the Apollo Housekeeping (known as "Word 33") tapes. made available to the National Space Science Data Center (NSSDC) by Yosio Nakamura (University of Texas Institute for Geophysics). We have converted selected parts of the telemetry into uncalibrated and calibrated output voltages and temperatures.

McBride, M. J.↗

Structural Analysis Using NX Nastran 9.0

NX Nastran is a powerful Finite Element Analysis (FEA) software package used to solve linear and non-linear models for structural and thermal systems. The software, which consists of both a solver and user interface, breaks down analysis into four files, each of which are important to the end results of the analysis. The software offers capabilities for a variety of types of analysis, and also contains a respectable modeling program. Over the course of ten weeks, I was trained to effectively implement NX Nastran into structural analysis and refinement for parts of two missions at NASA's Kennedy Space Center, the Restore mission and the Orion mission.

NX Nastran↗

Orbiter Interface Unit and Early Communication System

This report describes the Orbiter Interface Unit (OIU) and the Early Communication System (ECOMM), which are systems of electronic hardware and software that serve as the primary communication links for the International Space Station (ISS). When a space shuttle is at or near the ISS during assembly and resupply missions, the OIU sends groundor crew-initiated commands from the space shuttle to the ISS and relays telemetry from the ISS to the space shuttle s payload data systems. The shuttle then forwards the telemetry to the ground. In the absence of a space shuttle, the ECOMM handles communications between the ISS and Johnson Space Center via the Tracking and Data Relay Satellite System (TDRSS). Innovative features described in the report include (1) a "smart data-buffering algorithm that helps to preserve synchronization (and thereby minimize loss) of telemetric data between the OIU and the space-shuttle payload data interleaver; (2) an ECOMM antenna-autotracking algorithm that selects whichever of two phased-array antennas gives the best TDRSS signal and electronically steers that antenna to track the TDRSS source; and (3) an ECOMM radiation-latchup controller, which detects an abrupt increase in current indicative of radiation-induced latchup and temporarily turns off power to clear the latchup, restoring power after the charge dissipates.

Cobbs, Ronald M.↗

Rapid Monitoring and Defense Approach for Resilience Improvement of Grid Cyber Security

Cyber-physical systems and electric utilities significantly depend on the reliability and efficiency of information and operational technology. However, false data injection attacks based on synchrophasor measurement data pose a serious threat to the safe and reliable operation of modern power systems. Here, to mitigate this problem, a rapid monitoring and defense approach is proposed to defend against cyber attacks. Initially, the Time and Frequency based Convolutional neural Network (TFCN) is proposed to detect different types of attacks. Within the TFCN, the advances are that both time and frequency domain information can be fused without extra spectrum analysis methods, and can save detection time to speed the calculation efficiency using the developed time-frequency block. Next, a comprehensive defense strategy is developed for multiple cyber attacks to ensure the stability and resilience of the power system according to the feedback detection results. The advances of this strategy are that different control strategies can be automatically selected to recover the stability to the greatest extent according to the detected attacks. To verify the effectiveness of the proposed approach, the high-speed frequency measurements collected from the wide-area monitoring system are used. The results demonstrate that the cyber attack detection performance can reach 95.57% accuracy, outperforming both traditional and some advanced neural networks. Importantly, the defense strategy is conducted and verified in a modified IEEE 39 bus system as well, which illustrates profound performance in faster stability restoration.

Comprehensive defense strategy↗

Overload protection system for power inverter

An overload protection system for a power inverter utilized a first circuit for monitoring current to the load from the power inverter to detect an overload and a control circuit to shut off the power inverter, when an overload condition was detected. At the same time, a monitoring current inverter was turned on to deliver current to the load at a very low power level. A second circuit monitored current to the load, from the monitoring current inverter, to hold the power inverter off through the control circuit, until the overload condition was cleared so that the control circuit may be deactivated in order for the power inverter to be restored after the monitoring current inverter is turned off completely.

Nagano, S.↗

Vis-SAGA: Visual Analytics for Situational Awareness of Grid Anomalies: Preprint

We describe supporting near real-time situational awareness of the electric distribution system by visualizing novel data from voltage sensors deployed on existing broadband cable television network equipment. Our scalable web-based visual analytics platform supports interactive geospatial exploration, time-series analysis, and summarization of grid behavior during potentially anomalous events. The broadband cable television sensor network provides observability of the electrical distribution system at a higher local spatial resolution than is typically available to most utilities, revealing the operational state of the network and aiding in the detection of abnormal behaviors or deviations from expected patterns, particularly across electric utility service areas. We outline the design and development of interactive geospatial and time-series visualization components and the scalable data services that supply metadata, historical, and real-time streams of sensor data across the network. We evaluate our platform during periods of extreme weather, demonstrating its ability to assist in detecting patterns of operation that affect power availability, quality, resiliency, and service restoration.

cable television↗