Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power system operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Continuous-time look-ahead flexible ramp scheduling in real-time operation

This paper develops a novel continuous-time look-ahead optimization model for co-optimizing balancing energy and flexible ramp products in real-time power systems operation. In addition, a continuous-time day-ahead operation model is developed to commit and schedule an adequate subset of generating units for providing balancing energy and ramping requirements in real-time operation. The up and down flexible ramp products are defined as continuous-time decision trajectories that continuously supply the real-time up and down ramping requirements of the system. The deliverability of flexible ramp products is secured through reserving the respective power requirements in generation capacity constraints of generating units. A function space solution method is proposed to reduce the dimensionality of day-ahead and real-time models through projecting them into finite-dimensional function spaces spanned by Bernstein polynomials, where the real-time operation decisions are modeled with a higher accuracy level than day-ahead decisions. Simulations are conducted on the IEEE-RTS system using CAISO load data, and the numerical results showcase the effectiveness of the proposed model in supplying the energy and flexible ramp requirements and avoiding ramping scarcity in the system, while reducing the operation costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Economical and Engineering Aspects of Proactive Demand Participation: Centralized versus Bilateral Control Structure

The electric grid of the U.S. is evolving from a system characterized by large and centralized fossil-fueled power plants and passive customers to a network with high penetration of distributed energy resources and proactive customers. This project facilitated the evolution of the U.S. electric power grid by enabling proactive participation of demands in electricity market at the power distribution system level. This project has three major achievements. First, we designed a centralized distribution system operator managed electricity market and developed a three-phase alternating current optimal power flow algorithm to coordinate the operation of large-scale flexible loads and distributed energy resources. Second, we designed a decentralized bilateral coordinate framework for retail electricity market, where each participating customer is capable of making decisions regarding energy production and consumption based on information received from transactive neighbors. Third, the impacts of centralized and decentralized demand-side participation scheme on power system operations were evaluated with both large-scale simulations and hardware-in-the-loop demonstrations. The major activities and specific accomplishments of the technical tasks are summarized in Section II. The detailed design of centralized/hierarchical and decentralized/bilateral retail electricity markets and the comparison between the two markets are described in Section III. The accomplishments and conclusions of the project are presented in Section IV. The major findings of the project falls into three areas, hierarchical distribution system operator managed electricity market, bilateral electricity market and decentralized market coordination, and comparison of centralized and decentralized market coordination mechanisms. In the area of hierarchical distribution system operator managed electricity market design, an integrated wholesale and retail electricity market was shown to be highly effective in extracting the operational flexibility from distributed energy resources to provide services to the wholesale market. A chordal conversion based convex iteration algorithm is not only computationally efficiency but also achieves global optimal solution in coordinating the operations of a large number of heterogeneous distributed energy resources.In the area of decentralized market coordination approach, we showed that bilateral transactions among proactive customers and decentralized transaction clearing mechanism based on simultaneous second-price sealed-bid auction can encourage truthful bidding strategies from the market participations. In addition, the individual customers can rely on a portfolio optimization approach to maximize their returns while minimizing risks. In the area of comparison of centralized and decentralized market coordination mechanisms, we found that the centralized market design results in higher social welfare and lower wholesale market clearing price for electricity. In general, centralized market design favors distributed energy resources and fixed loads. The decentralized market design mostly benefits flexible loads and conventional generators.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Space environmental interactions with biased spacecraft surfaces

Large, high-voltage space power systems are being proposed for future space missions. These systems must operate in the charged-particle environment of space, and interactions between this environment and the high-voltage surfaces are possible. Ground simulation testing has indicated that dielectric surfaces that usually surround biased conductors can influence these interactions. For positive voltages greater than 100 V, it has been found that the dielectrics contribute to discharges. Using these experimental results a large, high-voltage power system operating in geosynchronous orbit was analyzed with the NASCAP code. Results of this analysis indicated that very strong electric fields exist in these power systems. A technology investigation is required to understand the interactions and develop techniques to alleviate any impact on power system performance.

Stevens, N. J.↗

Allocation Mechanisms in Rationed Markets

Economic theory has come to play an important role in power system operations through the design of wholesale markets that are central to their operation. Furthermore, transactive energy places economic theory as a cornerstone in its operational concept as it seeks to integrate the technical needs of the power system with the preferences of its participants. Traditionally the mechanism employed is the continuous double-auction but de-pending on the circumstances the power system find itself in, this mechanism may or may not be the most appropriate, i.e. a one-size fits all market institution cannot be recommended without regard for the features of the underlying trading environment. This paper seeks to explain the economic rationale that guides the choice of a market institution and takes recourse to a theoretical demonstration in the context of a rationed power system scenario where demand exceeds generation (due to any number of events such as outages, microgrid operation, etc) and electrical energy must be rationed to better understand which types of mechanisms are most appropriate.

transactive energy, power system economics, econom↗

An analysis of I/O efficient order-statistic-based techniques for noise power estimation in the HRMS sky survey's operational system

Noise power estimation in the High-Resolution Microwave Survey (HRMS) sky survey element is considered as an example of a constant false alarm rate (CFAR) signal detection problem. Order-statistic-based noise power estimators for CFAR detection are considered in terms of required estimator accuracy and estimator dynamic range. By limiting the dynamic range of the value to be estimated, the performance of an order-statistic estimator can be achieved by simpler techniques requiring only a single pass of the data. Simple threshold-and-count techniques are examined, and it is shown how several parallel threshold-and-count estimation devices can be used to expand the dynamic range to meet HRMS system requirements with minimal hardware complexity. An input/output (I/O) efficient limited-precision order-statistic estimator with wide but limited dynamic range is also examined.

Zimmerman, G. A.↗

Integration of Variable Generation and Cost-Causation (Fact Sheet)

Variable renewable energy generation sources, such as wind and solar energy, provide benefits such as reduced environmental impact, zero fuel consumption, and low and stable costs. Advances in both technologies can reduce capital costs and provide significant control capabilities. However, their variability and uncertainty - which change with weather conditions, time of day, and season - cancause an increase in power system operating costs compared to a fully controllable power plant. Although a number of studies have assessed integration costs, calculating them correctly is challenging because it is difficult to accurately develop a baseline scenario without variable generation that properly accounts for the energy value. It is also difficult to appropriately allocate costs giventhe complex, nonlinear interactions between resources and loads.

14 SOLAR ENERGY↗

Stochastic correlation analysis to rank the impact of intermittent wind generation on unreliability margins of power systems

Power systems are vulnerable to extreme contingencies (like an outage of a major generating substation or transmission line) that can cause significant generation and load loss and can lead to further cascading outages of other transmission facilities and generators in the system. Power systems operators take time-ahead actions (real time to day ahead) actions based on forecasted data as well as telemetry. However, there is a probability of extreme swings in wind generation that can push the power system that is already close to system boundaries into unreliable states. Increasing penetration on wind generation and uncertainties in short term forecast can move the system into operational states that can violate N-1 reliability criteria. While the power system planning accounts for worst case analyses to mitigate such emergencies, it is necessary to understand the spatial and temporal correlation of load buses with intermittent wind generation. The ranking of wind generators based on stochastic correlation to unreliability margins of load buses provides an insight of system vulnerabilities that can be corrected by appropriate emergency controls. A Monte-Carlo simulation of wind uncertainty forecast is performed to identify the probability distributions of unreliability margins. Ranking of wind generators is performed based on stochastic correlation analysis of the wind power generated and the load losses at the buses. This helps in not only identifying weak buses in the power system but also in identifying the vulnerable wind locations to plan for system reinforcements. Power system modeling and hybrid simulation to calculate unreliability margins are performed using DCAT and demonstrated on the 32-bus Nordic test system.

generators, wind forecasting, wind power generatio↗

How Do Wind and Solar Power Affect Grid Operations: The Western Wind and Solar Integration Study

The Western Wind and Solar Integration Study is one of the largest regional wind and solar integration studies to date, examining the operational impact of up to 35% wind, photovoltaics, and concentrating solar power on the WestConnect grid in Arizona, Colorado, Nevada, New Mexico, and Wyoming. This paper reviews the scope of the study, the development of wind and solar datasets, and the results to date on three scenarios.

17 WIND ENERGY↗

Western Wind and Solar Integration Study

The Western Wind and Solar Integration Study (WWSIS) is one of the largest regional wind and solar integration studies to date. It was initiated in 2007 to examine the operational impact of up to 35% energy penetration of wind, photovoltaics (PV), and concentrating solar power (CSP) on the power system operated by the WestConnect group of utilities in Arizona, Colorado, Nevada, New Mexico, and Wyoming (see study area map). WestConnect also includes utilities in California, but these were not included because California had already completed a renewable energy integration study for the state. This study was set up to answer questions that utilities, public utilities commissions, developers, and regional planning organizations had about renewable energy use in the west: (1) Does geographic diversity of renewable energy resource help mitigate variability; (2) How do local resources compare to out-of-state resources; (3) Can balancing area cooperation help mitigate variability; (4) What is the role and value of energy storage; (5) Should reserve requirements be modified; (6) What is the benefit of forecasting; and (7) How can hydropower help with integration of renewables? The Western Wind and Solar Integration Study is sponsored by the U.S. Department of Energy (DOE) and run by NREL with WestConnect as a partner organization. The study follows DOE's 20% Wind Energy by 2030 report, which did not find any technical barriers to reaching 20% wind energy in the continental United States by 2030. This study and its partner study, the Eastern Wind Integration and Transmission Study, performed a more in-depth operating impact analysis to see if 20% wind energy was feasible from an operational level. In DOE/NREL's analysis, the 20% wind energy target required 25% wind energy in the western interconnection; therefore, this study considered 20% and 30% wind energy to bracket the DOE analysis. Additionally, since solar is rapidly growing in the west, 5% solar was also considered in this study. The goal of the Western Wind and Solar Integration Study is to understand the costs and operating impacts due to the variability and uncertainty of wind, PV, and CSP on the grid. This is mainly an operations study, (rather than a transmission study), although different scenarios model different transmission build-outs to deliver power. Using a detailed power system production simulation model, the study identifies operational impacts and challenges of wind energy penetration up to 30% of annual electricity consumption.

14 SOLAR ENERGY↗

The Potential Impact of Offshore Wind Energy on a Future Power System in the U.S. Northeast

This study aims to understand and quantify the potential impact of offshore wind on a future electricity system in the U.S. Northeast. In this analysis, a detailed representation of the Northeast power system is adopted, using a generation portfolio for 2024 paired with offshore wind nameplate capacities of 0 gigawatts (GW), 2 GW, and 7 GW. The analysis identifies points of offshore wind interconnection in the ISO-New England and New York Independent System Operator control areas and uses hourly wind profiles from the Wind Integration National Dataset Toolkit. Hourly simulations of the 2024 power system operations show an ability to accommodate the prescribed offshore wind capacities by adapting the system's generation dispatch. Curtailment levels of offshore wind range between 4% and 5%. Offshore wind generation displaces primarily natural-gas combined-cycle generation; however, requires increased flexibility from combined cycles through more frequent start-ups. The number of hours with transmission congestion increases because of offshore wind injection, with varying impact on a subregional level. Offshore wind's capacity credit was found to be 14.5%-28.3% and is lower than estimated in other large-scale power system studies, in part because this study considered a different weather year and a power system representation with higher shares of solar PV and onshore wind. The reliability contribution of resources is a topic area identified for more research and collaboration. The 7-GW scenario shows a reduction in locational marginal price of 11%, with production cost savings of up to 18% compared to the 0-GW scenario.

17 WIND ENERGY↗

Eastern Wind Integration and Transmission Study - Preliminary Findings

The Eastern Wind Integration and Transmission Study is one of the largest regional wind integration studies to date, examining the operational impact of 20% and 30% wind energy in the Eastern Interconnect and the transmission expansion needed to achieve those wind energy penetrations. This paper reviews the scope of the study, the development of wind datasets, the transmission expansion analysis, and the results to date of the wind integration analysis for the four scenarios.

17 WIND ENERGY↗

PSI (PowerSimulations.jl) [SWR-23-104]

PowerSimulations.jl is a Julia-based BSD- licensed power system operations simulation tool developed as a flexible and open source software for quasi-static power systems simulations including Production Cost Models. PowerSimulations.jl tackles the issues of developing a simulation model in a modular way providing tools for the formulation of decision models and emulation models that can be solved independently or in an interconnected fashion. For further information regarding the Sienna modeling framework at NREL, see: https://www.nrel.gov/analysis/sienna.html

Lara Aguilar, Jose Daniel↗

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?: Preprint

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converterinterfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. An interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a variedlength transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

14 SOLAR ENERGY↗

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converter-interfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. A potential interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a varied-length transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

grid-following inverters↗

Design and Implementation of Real-Time Off-Grid Detection Tool Based on FNET/GridEye

Real-time situational awareness tools are of critical importance to power system operators, especially during emergencies. The availability of electric power has become a linchpin of most post disaster response efforts as it is the primary dependency for public and private sector services, as well as individuals. Knowledge of the scope and extent of facilities impacted, as well as the duration of their dependence on backup power, enables emergency response officials to plan for contingencies and provide better overall response. Based on real-time data acquired by Frequency Disturbance Recorders (FDRs) deployed in the North American power grid, a real-time detection method is proposed. This method monitors critical electrical loads and detects the transition of these loads from an on-grid state, where the loads are fed by the power grid to an off-grid state, where the loads are fed by an Uninterrupted Power Supply (UPS) or a backup generation system. The details of the proposed detection algorithm are presented, and some case studies and off-grid detection scenarios are also provided to verify the effectiveness and robustness. Meanwhile, the algorithm has already been implemented based on the Grid Solutions Framework (GSF) and has effectively detected several off-grid situations.

Guo, Jiahui↗

Cyber Security of the Electric Power Grid

Economic security and quality of life in modern society depend on the reliable supply and delivery of electric power. New cyber security vulnerabilities are emerging that introduce new risks to the Nation’s electric power grid. This presentation will describe issues, trends, and research opportunities for enhancing the cyber security of control systems associated with electric power system operations.

computer security↗