Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Plant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Planning for Nuclear Power Plant Site Visits - 20481

The U.5. Department of Energy Office of Integrated Waste Management (DOE-IWM) is planning for future large-scale transport of commercial spent nuclear fuel (SNF) and high-level radioactive waste (HLW) to eventual disposal and/or storage facilities. As part of its planning efforts, DOE conducts evaluations of removing SNF from nuclear power plant sites. Site visits are a pivotal piece in the site evaluations that are conducted by DOE, and significant planning efforts are undertaken to design and implement site visits. Site visits typically include three days of surveys and meetings, including one day each for the nuclear power plant site visit, evaluating near-site transportation infrastructure, and meeting with community engagement panels or advisory boards. This paper outlines DOE-IWM's planning process for conducting nuclear power plant site visits and summarizes the key activities carried out to prepare for a site visit, including a discussion of the background research conducted prior to a site visit. Additionally, the paper describes the development of reference databases for site visits, the identification of unique site characteristics, and the use of geographic information system (GIS) applications to enhance the quality of the information collected during a site visit. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High-Temperature Multi-Process Sensor Development and Demonstration at Coalfired Power Plants

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Solar pond power plant feasibility study for Davis, California

The feasibility of constructing a solar pond power plant at Davis, California was studied. Site visits, weather data compilation, soil and water analyses, conceptual system design and analyses, a material and equipment market survey, conceptual site layout, and a preliminary cost estimate were studied. It was concluded that a solar pond power plant is technically feasible, but economically unattractive. The relatively small scale of the proposed plant and the high cost of importing salt resulted in a disproportionately high capital investment with respect to the annual energy production capacity of the plant. Cycle optimization and increased plant size would increase the economical attractiveness of the proposed concept.

Wu, Y. C.↗

NASA's PEM Fuel Cell Power Plant Development Program for Space Applications

NASA embarked on a PEM fuel cell power plant development program beginning in 2001. This five-year program was conducted by a three-center NASA team of Glenn Research Center (lead), Johnson Space Center, and Kennedy Space Center. The program initially was aimed at developing hardware for a Reusable Launch Vehicle (RLV) application, but more recently had shifted to applications supporting the NASA Exploration Program. The first phase of the development effort, to develop breadboard hardware in the 1-5 kW power range, was conducted by two competing vendors. The second phase of the effort, to develop Engineering Model hardware at the 10 kW power level, was conducted by the winning vendor from the first phase of the effort. Both breadboard units and the single engineering model power plant were delivered to NASA for independent testing. This poster presentation will present a summary of both phases of the development effort, along with a discussion of test results of the PEM fuel cell engineering model under simulated mission conditions.

Hoberecht, Mark↗

Dynamic Simulation of a Sub-Critical Coal Fired Power Plant

In order to address the demanding operating conditions for remaining coal-fired power plants, a dynamic model and a suite of tools have been developed for studying load cycling and to find optimization opportunities. A sub-critical steam cycle power plant was modeled in a flow-sheet modeling tool, APROS™. The model represented the firing system, economizer, evaporator, superheat, and reheat systems. Four loads from 100% TMCR to 25% TMCR were calibrated and tested such that low-to-high cycling could be studied. The model was run through various load cycles; one of which is presented here. This modeling is a prototype for general use in developing cutting edge controls products and for maximizing economic, low-emissions, and efficient operation of the existing coal power fleet.

Braun, Timothy↗

Probing-Based Inertia Estimation Method Using Hybrid Power Plants

With the displacement of synchronous generation by inverter-based resources (IBRs), power systems could face the challenge of reduced inertia since IBRs do not inherently contribute to system inertia. Therefore, there is rising interest in monitoring system inertia in real-time applications for situational awareness. In addition, there is a growing number of IBRs that provide fast frequency responses (FFR) in the form of synthetic inertia and P-f droop. It is desirable to quantify the contribution of these FFR controls as equivalent inertia. This paper proposes a probing-based inertia estimation method using a PV-battery hybrid power plant in the Kauai island power system. The method is validated under different operating conditions.

hybrid power plant↗

Time-dependent scenario modeling for the ST-E1 fusion power plant

ST-E1 is a low aspect ratio fusion power plant being designed by Tokamak Energy targeting 1.5 GW of fusion power. Characterization of the ST-E1 flat-top scenario is described elsewhere McNamara et al (2026 Nucl. Fusion 66 086008); here we focus on addressing the question of how to ramp-up the ST-E1 plasma from an initial state following breakdown and flux-surface formation to the target flat-top state. Being low-aspect ratio, the available solenoid flux of ST-E1 is limited. Therefore, particular consideration is placed on developing ramp-up scenarios that predominantly use inductive flux provided by external vertical field coils. Through time-dependent modeling with METIS, we show that this is possible when the ramp-up is performed at relatively high plasma density: although auxiliary current drive efficiency is reduced, this is significantly outweighed by (1) higher electron-ion collisional equilibration, (2) higher fusion power once ions become sufficiently hot, (3) higher poloidal beta for increased vertical-field flux, and (4) potentially favorable exhaust compatibilities. Ultimately, we show the target ST-E1 flat-top performance can be reached after a ramp-up period lasting 150 s using less than 40 Vs of solenoid flux (with vertical field providing ∼ 90 Vs of flux). The sensitivity to model assumptions are presented, with the general observation that deleterious effects can be mitigated through minor alterations of the auxiliary power temporal waveform and/or total auxiliary power level. The impact of a solenoid and the auxiliary power mix (electron cyclotron heating only versus electron and ion cyclotron heating) on the ST-E1 ramp-up success are also discussed in appendices. On this latter topic, we show that the effect of direct-ion heating during ramp-up is obscured by the uncertainty in the pedestal dynamics, identifying a clear line of future work required to make a definite decision on the ST-E1 auxiliary power mix.

current ramp-up↗

The Co-Firing of Pine Biomass and Waste Coal in 100 and 600 MW Power Plants: A Sustainable Approach to Reduce GHG Emissions

Climate change is a global issue that has gained much attention recently. Co-firing biomass with coal/waste coal reduces the electricity sector’s GHG emissions sustainably. This study uses commercial software to model waste coal and biomass co-firing in 100 MW and 600 MW power plants. The objective is to assess the effects of fluid types (subcritical and supercritical), plant capacities (100 MW and 600 MW), boiler types (pulverized coal and circulating fluidized bed boilers), biomass and waste coal co-firing ratios (0:100, 20:80, 40:60, 60:40, 80:20, and 100:0), and carbon capture and storage efficiencies (0%, 90%, 95%, and 97%) on performance parameters such as net plant efficiency, heat rate, net plant CO2 and SO2, and particulate matter emissions. The feedstocks selected for this investigation include anthracite waste coal and loblolly pine biomass. As the biomass fraction increases from 0% to 100%, co-fired power plants net efficiency increases by 3–8%. Supercritical plants had a 6% higher net plant efficiency than the subcritical plants. The study found that the biomass’s high heating value decreased the fuel flow rate and reduced plant CO2 emissions by 10–16%. With 100% biomass power plant feed and 90% carbon capture and storage efficiency, CO2 emissions drop by 83% and SO2 and PM emissions drop to zero.

Bhoi, Prakashbhai R. (ORCID:0000000333104888)↗

Machine Learning-Assisted Stability Boundary Determination of Multiport Autonomous Reconfigurable Solar Power Plants

The multiport autonomous reconfigurable solar (MARS) power plant is a promising solution to integrate renewable resources and energy storage systems into the alternating current (ac) power grid and an high-voltage direct current (HVdc) link. In the MARS system, various input power sources are connected to the individual submodules (SMs) through direct current (dc)–dc converters. However, the presence of external power sources can result in unbalanced capacitor voltages of SMs, thereby violating stability constraints under multiple/diverse operating conditions. This article aims to address the gap by accurately determining the stability boundary of the MARS system. As such, a novel machine learning (ML)-assisted energy balancing control (EBC) criterion is proposed. Further, in conjunction with a refined EBC, this approach ensures balanced capacitor voltages across various types of SMs, significantly enhancing the overall system efficiency. The proposed EBC criterion effectively controls EBC activation and deactivation, achieving remarkable accuracy. Both power systems computer aided design (PSCAD)/electromagnetic transients including direct current (EMTDC) simulations and control hardware-in-the-loop (cHIL) tests are conducted to validate the feasibility and efficiency of the proposed method. By combining the EBC and ML-assisted EBC criterion, efficient energy management is achieved for systems featuring multiple input power sources, such as MARS. This approach enables the system to fully exploit its potential across an expanded operational range while upholding high-efficiency standards.

14 SOLAR ENERGY↗

Impedance Analysis and PHIL Demonstration of Reactive Power Oscillations in a Wind Power Plant Using a 4-MW Wind Turbine

This paper presents impedance-based analysis, mitigation, and power-hardware-in-the-loop (PHIL) demonstration of reactive power oscillations in a wind power plant using a 4-MW Type III wind turbine drivetrain. Because such low-frequency oscillations result from interactions among slower control loops of wind turbines regulating phasor quantities—active and reactive power output of the wind turbine and the magnitude of voltages at the point of interconnection (POI)—a new type of admittance is defined in terms of phasor quantities for their analysis. The so-called power-domain admittance of a wind turbine is defined as the transfer function from the frequency and magnitude of voltages at the POI to the active and reactive power output of the turbine. The power-domain admittance responses of the 4-MW wind turbine are measured using a 7-MVA grid simulator to identify the source of the reactive power oscillations. Power-domain impedance analysis and PHIL experiments are performed to explain how a resonant mode manifests as turbine-to-turbine and plant-to-grid reactive power oscillations. It is discovered that weaker grids exhibiting high inductive impedance mitigate oscillations in the reactive power output of wind power plants; however, a higher grid impedance does not help in damping turbine-to-turbine reactive power oscillations. This paper presents a simple droop-based solution to eliminate both turbine-to-turbine and plant-to-grid reactive power oscillations.

17 WIND ENERGY↗

Data Curation for Machine Learning Applied to Geothermal Power Plant Operational Data for GOOML: Geothermal Operational Optimization with Machine Learning: Preprint

Geothermal Operational Optimization with Machine Learning (GOOML) is a transferable and extensible component-based geothermal asset modeling framework that considers complex steamfield relationships and identifies optimization prospects using a data-driven approach to physics-guided, data-centric machine learning. This framework has been used to develop digital twins that provide steamfield operators with operational environments to analyze and understand historical and forecasted power production, explore new steamfield configuration possibilities, and seek optimal asset management in real world applications. To create, test, and apply the GOOML framework, diverse time-series datasets spanning multiple years were sourced from various geothermal power plant components within several complex real-world geothermal operations. These operations are based in the United States and New Zealand and include a variety of technologies, end-uses and configurations, collectively covering nearly all relevant operating conditions for modern geothermal fields. Datasets were acquired from multiple sources to ensure that machine learning experiments generalized properly to various operating conditions. It was found that the data varied in quality, format, and completeness. To ensure consistency between the various datasets, a standardized data curation process was developed to reliably streamline data preparation. This paper will discuss best practices as learned from the GOOML data curation process which takes the following steps: 1) acquisition of large quantities of data from power plant operators, 2) digestion of data to gain an initial understanding of what is included, 3) data transformation, which includes converting the data into a standardized machine-readable format so that they can be visualized, quality checked, and cleaned, 4) quality assurance and quality control, involving identification of significant data gaps and apparent anomalies through mapping of data features to real world componentry via the GOOML historical model, followed by discussion with modelers and power plant operators to identify additional data needs and to resolve issues, 5) use in machine learning algorithms, and 6) repetition of steps one through five until all data needs are met and data are deemed suitable for producing trustworthy modeling results which may be disseminated, ideally along with the curated dataset. This iterative process is focused on improving the quality of the data rather than tuning machine learning model parameters and supports a shift towards data-centric AI as a means to improving real-world applicability of geothermal machine learning projects.

access↗

Energy Storage and Power Plant Decommissioning

The report examines three fossil-fuel power plant decommissioning strategies to assess the role of energy storage in enabling an equitable clean energy transition future. The analysis showed how storage could enable reduction of fossil-fuel sources from the grid while enabling increased renewable energy integration into the electric grid. The report offers recommendations for future work, including the need to further develop the non-energy benefit attributes of energy storage systems with a focus on the benefits accrued to local communities to understand past decisions and inform future decision-making tools that account for environmental, economic, and social impacts, particularly those on disadvantaged communities.

20 FOSSIL-FUELED POWER PLANTS↗

Gas Turbine Energy Conversion Systems for Lunar and Planetary Nuclear Power Plants Including Ground Based Applications Using LiFTR "Liquid Fluoride Thorium Reactor" Technology

The background and motivation for this presentation is the Advanced Nuclear Power named in Energy Policy Act of 2005 (Gen IV Nuclear Systems Initiative), Thorium Energy Independence & Security Act of 2008 (S.3680), Gen IV Candidate Advanced Nuclear Power Plants, and high temperature gas turbine power plants offer large thermal efficiency improvement over steam plants.

Juhasz, Albert J.↗

Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Coal and Biomass – Integration of Combustor Boiler and DCC

Critical to the future of power generation is the development of a power plant that will be capable of flexible operation to meet the needs of the modern grid, providing resilient, low-emissions power to a grid that is increasingly seeing a large penetration of intermittent wind and solar. The modular Staged, Pressurized Oxy-Combustion (SPOC) process envisioned by and under development at Washington University in St. Louis (WUSTL) has the potential to achieve these goals. The process offers: 1) a modular plant design for improved operational flexibility; 2) fuel-staging combined with pressurized oxy-combustion, which leads to smaller plant size, higher plant efficiency, and lower cost for pollutant and greenhouse gas removal compared with traditional carbon-capture equipped coal power plants; and 3) small modular boilers and pollutant removal units that can be fabricated in shop and assembled on site, further reducing plant capital costs. Under DOE's support (DE-FE0031925), WUSTL is advancing the development of the critical components for the SPOC power plant, including the integrated combustion system and the direct contact cooler (DCC) from Technology Readiness Level (TRL) 4 to TRL-5, which would allow these technologies to be subsequently incorporated into a pilot plant. This talk will present an overview of the SPOC technology, CFD modeling and validation for burner and boiler development, and recent results to evaluate critical components for system integration needed to advance its TRL.

Magalhaes, Duarte↗

Early retirement of power plants in climate mitigation scenarios

International efforts to avoid dangerous climate change aim for large and rapid reductions of fossil fuel CO 2 emissions worldwide, including nearly complete decarbonization of the electric power sector. However, achieving such rapid reductions may depend on early retirement of coal- and natural gas-fired power plants. Here, we analyze future fossil fuel electricity demand in 171 energy-emissions scenarios from Integrated Assessment Models (IAMs), evaluating the implicit retirements and/or reduced operation of generating infrastructure. Although IAMs calculate retirements endogenously, the structure and methods of each model differ; we use a standard approach to infer retirements in outputs from all six major IAMs and—unlike the IAMs themselves—we begin with the age distribution and region-specific operating capacities of the existing power fleet. We find that coal-fired power plants in scenarios consistent with international climate targets (i.e. keeping global warming well-below 2 °C or 1.5 °C) retire one to three decades earlier than historically has been the case. If plants are built to meet projected fossil electricity demand and instead allowed to operate at the level and over the lifetimes they have historically, the roughly 200 Gt CO 2 of additional emissions this century would be incompatible with keeping global warming well-below 2 °C. Thus, ambitious climate mitigation scenarios entail drastic, and perhaps un-appreciated, changes in the operating and/or retirement schedules of power infrastructure.

20 FOSSIL-FUELED POWER PLANTS↗

Synchronous Wind: Evaluating the Grid Impact of Inverterless Grid-Forming Wind Power Plants

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators has attracted substantial attention in power systems research; however, the limited over-current capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. This paper develops the generic model of synchronous wind power generators, also known as Type-5 wind turbines, for power system integration studies. The Type-5 wind turbine interfaces with the electric grid through a synchronous generator; hence, its operation and consequent grid impacts are similar to a conventional power plant. Based on the developed model, a Type-5 wind power plant is integrated into the IEEE 14-bus test bed to evaluate its control and operation with a bulk power system. Finally, the stability properties of Type-5 wind turbine generators are compared with Type-3 wind turbines in GFM control mode through impedance characterization.

grid strength↗

Energy Infrastructure Futures: A Multiscale Evaluation of Projected Power Plant Siting Across the Western Interconnection

The US Western Interconnection is facing unprecedented challenges in the form of less predictable peak demand, increasingly diverse generating resources, and fast-growing loads due to the onset of artificial intelligence, hyperscale computing, and electrification. Projecting where future generation may be developed is critical to maintaining a robust and resilient electric grid under this mounting uncertainty and variability. Using an integrated multisectoral, multiscale modeling framework that links a human-Earth systems model, an hourly load model, a geospatial power plant siting model, and an hourly grid operations model, we evaluate the power plant landscape evolution under eight alternative futures between 2020 and 2055. These futures represent a wide but plausible range of atmospheric conditions, emissions constraints, and economic, technological, and population growth assumptions. We find that local-level development can vary substantially both by generation type and capacity buildout across these futures. Specific regions of the Western Interconnection are projected to see large amounts of capacity development regardless of the future scenario. We additionally determine that projected power plant locations are more heavily influenced by the cost to interconnect to the electric grid than the locational energy value.

Mongird, Kendall↗