Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Portal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Splenic Arterial Embolization in the Treatment of Severe Portal Hypertension Due to Pancreatic Diseases: The Primary Experience in 14 Patients

ObjectiveThis retrospective study reports our experience using splenic arterial particle embolization and coil embolization for the treatment of sinistral portal hypertension (SPH) in patients with and without gastric bleeding.MethodsFrom August 2009 to May 2012, 14 patients with SPH due to pancreatic disease were diagnosed and treated with splenic arterial embolization. Two different embolization strategies were applied; either combined distal splenic bed particle embolization and proximal splenic artery coil embolization in the same procedure for acute hemorrhage (1-step) or interval staged distal embolization and proximal embolization in the stable patient (2-step). The patients were clinically followed.ResultsIn 14 patients, splenic arterial embolization was successful. The one-step method was performed in three patients suffering from massive gastric bleeding, and the bleeding was relieved after embolization. The two-step method was used in 11 patients, who had chronic gastric variceal bleeding or gastric varices only. The gastric varices disappeared in the enhanced CT scan and the patients had no gastric bleeding during follow-up.ConclusionsSplenic arterial embolization, particularly the two-step method, proved feasible and effective for the treatment of SPH patients with gastric varices or gastric variceal bleeding.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Portal Vein Embolization with Contralateral Application of Stem Cells Facilitates Increase of Future Liver Remnant Volume in Patients with Liver Metastases

ObjectivesThis study aimed to evaluate the progress of future liver remnant volume (FLRV) in patients with liver metastases after portal vein embolization (PVE) with the application of hematopoietic stem cells (HSCs) and compare it with a patients control group after PVE only.MethodsTwenty patients (group 1) underwent PVE with contralateral HSC application. Subsequently, CT volumetry with the determination of FLRV was performed at weekly intervals, in total three weeks. A sample of twenty patients (group 2) who underwent PVE without HSC application was used as a control group.ResultsThe mean of FLRV increased by 173.2 mL during three weeks after the PVE/HSC procedure, whereas by 98.9 mL after PVE only (p = 0.015). Furthermore, the mean daily growth of FLRV by 7.6 mL in group 1 was significantly higher in comparison with 4.1 mL in group 2 (p = 0.007).ConclusionsPVE with the application of HSC significantly facilitates growth of FLRV in comparison with PVE only. This method could be one of the new suitable approaches to increase the resectability of liver tumours.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Segment 2/3 Hypertrophy is Greater When Right Portal Vein Embolisation is Extended to Segment 4 in Patients with Colorectal Liver Metastases: A Retrospective Cohort Study

Background: In patients with colorectal cancer liver metastases (CRLM), right portal vein embolisation (RPVE) is used to increase the volume of the future remnant liver (FRL) before major hepatic resection. It is not established whether embolisation of segment 4 in addition RPVE (RPVE + 4) induces greater hypertrophy of the FRL. Limitations of prior studies include heterogenous populations and use of hypertrophy metrics sensitive to baseline variables. Methods: From 2010 to 2015, consecutive patients undergoing RPVE or RPVE + 4 for CRLM, who had not undergone prior major hepatic resection and in whom imaging was available, were included in a retrospective study. Data were extracted from hospital electronic records. Volumetric assessments of segments 2–3 were made on cross-sectional imaging before and after embolisation and corrected for standardised liver volume. Results: Ninety-nine patients underwent PVE, and 60 met the inclusion criteria. Thirty-eight patients underwent RPVE, and 22 underwent RPVE + 4. Forty-five patients had undergone median 6 cycles of prior chemotherapy. Eighteen patients had FRL metastases at PVE, and 16 had undergone subsegmental metastasectomy in the FRL. Assessments of the degree of hypertrophy (DH) of segments 2/3 were made at median 35 (interquartile range 30–49) days after PVE. RPVE + 4 resulted in a significantly greater increase in DH than RPVE (7.7 ± 1.8% vs 11.3 ± 2.6%, p = 0.011). No confounding association between baseline variables and the decision to undertake RPVE or RPVE + 4 was identified. Median survival was 2.4 years and was not influenced by segment 4 embolisation. Conclusion: RPVE + 4 results in greater DH of segments 2/3 than RPVE in people with CLRM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Future Liver Remnant Indocyanine Green Plasma Clearance Rate as a Predictor of Post-hepatectomy Liver Failure After Portal Vein Embolization

PurposeTo evaluate the utility of future liver remnant plasma clearance rate of indocyanine green (ICGK-F) for predicting post-hepatectomy liver failure (PHLF) compared with percentage future liver remnant volume-to-total liver volume ratio (%FLR) after portal vein embolization (PVE).Materials and MethodsPVE procedures in 20 patients (15 patients underwent PVE with absolute ethanol; 5 patients with gelatin particles) from 2010 to 2017 were analyzed. %FLR = future liver remnant volume (ml)/[total liver volume (ml) − tumor volume (ml)] × 100; ICGK-F = plasma clearance rate of indocyanine green (ICGK) × %FLR/100 were calculated before and after PVE. PHLF was categorized according to the criteria of the International Study Group of Liver Surgery. For predicting PHLF, we compared the ICGK-F and %FLR after PVE between the grade A PHLF group and the non-grade A PHLF (grades B and C) group.ResultsAll PVE procedures were successful. While the ICGK-F of the grade A PHLF group (median 0.073, n = 16) was about twice that of the non-grade A PHLF group (median 0.043, n = 4), showing a significant difference (Mann–Whitney U test: P = 0.002), there was no significant difference in %FLR between the grade A PHLF group and the non-grade A PHLF group (Mann–Whitney U test: P = 0.335).ConclusionICGK-F was significantly higher in the grade A PHLF group than in the non-grade A PHLF group (grades B and C), and ICGK-F was more useful for predicting PHLF than %FLR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Time Series Evaluation of Radiation Portal Monitor Data for Point Source Discrimination.

A novel algorithm approach to evaluating data from PVT-based Radiation Portal Monitor (RPM) systems is established. Time series of data from RPMs are evaluated for the presence of sources of interest by comparing the background to the vehicle spectrum at each successive time step, isolating the contribution of anomalous radiation. At each time in the data sequence, a “spectral distance” index is calculated using this method. This method may dramatically reduce systematic fluctuations due to background attenuation by a vehicle (the so-called “shadow shielding” effect), and allow for time-series matched filtering for discrimination of compact anomalous sources. This is attempted by using a wavelet filter function of similar size to the expected source profile on the output of the spectral distance method. Performance of this method is shown by analysis (injection studies) of a number of real drive-through data sets taken at a U.S. port of entry. Spectra from isotopes of interest are injected into the data set, and the resultant “benign” and “injected” data sets are analyzed with gross-counting, spectral distance, and spatial algorithms. The combination of spectral and spatial analysis methods showed a significant increase to detection performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single Photon Emission Computed Tomography-Based Three-Dimensional Conformal Radiotherapy for Hepatocellular Carcinoma With Portal Vein Tumor Thrombus

Purpose: To evaluate the safety and efficacy of three-dimensional conformal radiotherapy (3D-CRT) using single photon emission computed tomography (SPECT) in unresectable hepatocellular carcinoma (HCC) with portal vein tumor thrombus (PVTT). Methods and Materials: Patients with HCC with PVTT in the first branch and/or main trunk were selected for this study. The optimal beam directions for 3D-CRT were explored using a Tc-99m-galactosyl human serum albumin SPECT image for guidance. The SPECT image was classified as either wedge type or localized type. The clinical target volume to a total dose of 45 or 50 Gy per 18-20 fractions included the main tumor and PVTT in the wedge type and PVTT alone in the localized type. Results: Twenty-six patients were enrolled: 18 with wedge type and 8 with localized type. Mean tumor size was 7.1 cm (range, 4.4-12.3 cm). Clinical target volumes of wedge type vs. localized type were 111.2 cm{sup 3} vs. 48.4 cm{sup 3} (p = 0.010), respectively. Mean dose to normal liver and mean dose to functional liver were 1185 cGy and 988 cGy (p = 0.001) in wedge type and 1046 cGy and 1043 cGy (p = 0.658) in localized type, respectively. Despite an incidence of Child-Pugh B and C of 57.7%, no patients experienced radiation-induced liver disease. The progression of PVTT was inhibited, with an incidence of 92.2%; survival rates at 1 and 2 years were 44% and 30%, respectively. Conclusion: Single photon emission computed tomography-based 3D-CRT enables irradiation of both the main tumor and PVTT with low toxicity and promising survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Treatment Responses in Cases of Radiation Therapy to Portal Vein Thrombosis in Advanced Hepatocellular Carcinoma

Purpose: To review the response to radiation therapy for hepatocellular carcinoma (HCC) with portal vein thrombosis (PVT) and determine the factors favoring its efficacy. Methods and Materials: Patients with HCC and PVT referred for radiation therapy between 1997 and 2005 were retrospectively reviewed. Patients who had undergone treatment to primary HCC before radiation or had extrahepatic metastasis were excluded. A radiation dose of 60 Gy with 2 to 3Gy per fraction was prescribed. Clinical features before therapy were investigated, and the most significant imaging change after radiotherapy was regarded as the treatment response. Survival times were compared and the hazard ratios of independent variables were determined. Results: The treatment response rate of the 326 patients included in the study was 25.2% (n = 82). The median survival times were 13.3, 11.6, 9.0, 4.5, and 2.1 months for complete response, partial response, vascular transformation, no response, and the lost follow-up patients, respectively. Statistically significant differences in survival were not found among responder groups (p = 0.224-0.916) but were found between responders and nonresponders (p = 0.002). The most significant independent variables associated with survival (p < 0.001) were performance status and radiation dose. Minor independent factors were ascites, alfa-fetoprotein, albumin, and HBsAg (p = 0.009-0.038). In patients with favorable performance status, those with no more than one minor risk factor had a superior prognosis after radiation therapy (p = 0.013). This result was verified by a review of similar patients in 2006. Conclusion: Radiation therapy is the treatment of choice for selected HCC patients with PVT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of Target Volume Changes During Breast Radiotherapy Using Implanted Fiducial Markers and Portal Imaging

Purpose: To determine target volume changes by using volume and shape analysis for patients receiving radiotherapy after breast conservation surgery and to compare different methods of automatically identifying changes in target volume, position, size, and shape during radiotherapy for use in adaptive radiotherapy. Methods and Materials: Eleven patients undergoing whole breast radiotherapy had fiducial markers sutured into the excision cavity at the time of surgery. Patients underwent imaging using computed tomography (for planning and at the end of treatment) and during treatment by using portal imaging. A marker volume (MV) was defined by using the measured marker positions. Changes in both individual marker positions and MVs were identified manually and using six automated similarity indices. Comparison of the two types of analysis (manual and automated) was undertaken to establish whether similarity indices can be used to automatically detect changes in target volumes. Results: Manual analysis showed that 3 patients had significant MV reduction. This analysis also showed significant changes between planning computed tomography and the start of treatment for 9 patients, including single and multiple marker movement, deformation (shape change), and rotation. Four of the six similarity indices were shown to be sensitive to the observed changes. Conclusions: Significant changes in size, shape, and position occur to the fiducial marker-defined volume. Four similarity indices can be used to identify these changes, and a protocol for their use in adaptive radiotherapy is suggested.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of CT on Rails With Electronic Portal Imaging for Positioning of Prostate Cancer Patients With Implanted Fiducial Markers

Purpose: The objective of this investigation was to measure the agreement between in-room computed tomography (CT) on rails and electronic portal image (EPI) radiography. Methods and Materials: Agreement between the location of the center of gravity (COG) of fiducial markers (FMs) on CT and EPI images was determined in phantom studies and a patient cohort. A secondary analysis between the center of volume (COV) of the prostate on CT and the COG of FMs on CT and EPI was performed. Agreement was defined as the 95% probability of a difference of {<=}3.0 mm between images. Systematic and random errors from CT and EPI are reported. Results: From 8 patients, 254 CT and EPI pairs were analyzed. FMs were localized to within 3 mm on CT and EPI images 96.9% of the time in the left-right (LR) plane, 85.8% superior-inferior (SI), and 89% anterior-posterior (AP). The differences between the COV on CT and the COG on EPI were not within 3 mm in any plane: 87.8% (LR), 64.2% (SI), and 70.9% (AP). The systematic error varied from 1.2 to 2.9 mm (SI) and 1.8-2.9 mm (AP) between the COG on EPI and COV on CT. Conclusions: Considerable differences between in-room CT and EPI exist. The phantom measurements showed slice thickness affected the accuracy of localization in the SI plane, and couch sag that occurs at the CT on rails gantry could not be totally corrected for in the AP plane. Other confounding factors are the action of rotating the couch and associated time lag between image acquisitions (prostate motion), EPI image quality, and outlining uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility and Efficacy of Single Photon Emission Computed Tomography-Based Three-Dimensional Conformal Radiotherapy for Hepatocellular Carcinoma 8 cm or More With Portal Vein Tumor Thrombus in Combination With Transcatheter Arterial Chemoembolization

Purpose: To assess the feasibility and efficacy of single photon emission computed tomography-based three-dimensional conformal radiotherapy (SPECT-B 3D-CRT) for large hepatocellular carcinoma (HCC) with portal vein tumor thrombus (PVTT). Methods and Materials: HCC patients with PVTT in the first branch or main trunk, 8 cm or greater in size, were admitted to the study. SPECT, using Tc-99m-galactosyl human serum albumin, was used in radiation treatment planning to explore the optimal irradiation beam angle. SPECT enabled the minimum possible irradiation of functional liver (FL). Clinical target volume (CTV) included the main tumor and PVTT. SPECT-B 3D-CRT targeted the CTV to a total dose of 45 Gy/18 fractions. HCC outside the CTV was treated by transcatheter arterial chemoembolization (TACE). Results: Nineteen cases were enrolled in this study. The mean maximum dimension, mean CTV, and mean dose to FL were 11.0 cm (range, 8.0-20.0), 435 cm{sup 3} (range, 60-2,535), and 1,102 cGy (range, 691-1,695), respectively. Follow-up SPECT demonstrated radiation-induced dysfunctional liver. Despite the inclusion of 6 cases of Child-Pugh B or C, no patients experienced Grade 3 or worse radiation-induced liver disease. The cumulative non-progression rates of PVTT and PVTT plus main tumor were 78.0 and 43.2%, respectively. Survival rates at 1 and 2 years were 47.4 and 23.7%, respectively. Conclusions: SPECT-B 3D-CRT with TACE appears to be tolerable to cirrhotic liver and to provide promising prognosis for patients with HCC sized 8 cm or more, in comparison with previous treatment methods. A longer follow-up period is required to evaluate these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Portal Hypertension in Children With Wilms' Tumor: A Report From the National Wilms' Tumor Study Group

Purpose: This analysis was undertaken to determine the cumulative risk of and risk factors for portal hypertension (PHTN) in patients with Wilms' tumor (WT). Methods and Materials: Medical records were reviewed to identify cases of PHTN identified with late liver/spleen/gastric toxicities in a cohort of 5,195 patients treated with National Wilms' Tumor Studies (NWTS) protocols 1 to 4. A nested case control study (5 controls/case) was conducted to determine relationships among doxorubicin, radiation therapy (RT) dose to the liver, patient gender, and PHTN. Conditional logistic regression was used to estimate adjusted hazard ratios (HR) of PHTN associated with these factors. Results: Cumulative risk of PHTN at 6 years from WT diagnosis was 0.7% for patients with right-sided tumors vs. 0.1% for those with left-sided tumors (p = 0.002). Seventeen of 19 cases were evaluable for RT. The majority of cases (16/17 [94%]) received right-flank RT either alone or as part of whole-abdomen RT and received >15 Gy to the liver. Fifteen of 17 (88%) patients received a higher dose to the liver than they would have with modern WT protocols. Controlling for RT dose, the HR was 3.0 for patients who received doxorubicin (p = 0.32) and 2.8 for females (p = 0.15). Controlling for doxorubicin, the 95% lower confidence bound on the HR associating PHTN with a minimum liver RT dose of >15 Gy vs. <=15 Gy was 2.5 (p = 0.001); it was 2.4 for a maximum liver dose of >15 Gy vs. <=15 Gy (p = 0.001). Conclusions: There was a strong association between higher doses of liver RT (>15 Gy) and the development of PHTN among WT patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Breast Patient Setup Error Assessment: Comparison of Electronic Portal Image Devices and Cone-Beam Computed Tomography Matching Results

Purpose: To quantify the differences in setup errors measured with the cone-beam computed tomography (CBCT) and electronic portal image devices (EPID) in breast cancer patients. Methods and Materials: Repeat CBCT scan were acquired for routine offline setup verification in 20 breast cancer patients. During the CBCT imaging fractions, EPID images of the treatment beams were recorded. Registrations of the bony anatomy for CBCT to planning CT and EPID to digitally reconstructed-radiographs (DRRs) were compared. In addition, similar measurements of an anthropomorphic thorax phantom were acquired. Bland-Altman and linear regression analysis were performed for clinical and phantom registrations. Systematic and random setup errors were quantified for CBCT and EPID-driven correction protocols in the EPID coordinate system (U, V), with V parallel to the cranial-caudal axis and U perpendicular to V and the central beam axis. Results: Bland-Altman analysis of clinical EPID and CBCT registrations yielded 4 to 6-mm limits of agreement, indicating that both methods were not compatible. The EPID-based setup errors were smaller than the CBCT-based setup errors. Phantom measurements showed that CBCT accurately measures setup error whereas EPID underestimates setup errors in the cranial-caudal direction. In the clinical measurements, the residual bony anatomy setup errors after offline CBCT-based corrections were {Sigma}{sub U} = 1.4 mm, {Sigma}{sub V} = 1.7 mm, and {sigma}{sub U} = 2.6 mm, {sigma}{sub V} = 3.1 mm. Residual setup errors of EPID driven corrections corrected for underestimation were estimated at {Sigma}{sub U} = 2.2mm, {Sigma}{sub V} = 3.3 mm, and {sigma}{sub U} = 2.9 mm, {sigma}{sub V} = 2.9 mm. Conclusion: EPID registration underestimated the actual bony anatomy setup error in breast cancer patients by 20% to 50%. Using CBCT decreased setup uncertainties significantly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiotherapy Plus Transarterial Chemoembolization for Hepatocellular Carcinoma Invading the Portal Vein: Long-Term Patient Outcomes

Purpose: We have evaluated the clinical outcomes of patients after transarterial chemoembolization (TACE) and 3-dimensional conformal radiotherapy for hepatocellular carcinoma (HCC) with portal vein tumor thrombosis (PVTT). Methods and Materials: A registry database of 412 patients treated with TACE and three-dimensional conformal radiotherapy for HCC with PVTT between August 2002 and August 2008 were analyzed retrospectively. The radiotherapy volume included the PVTT, with a 2- to 3-cm margin to cover adjacent HCC. Intrahepatic primary HCC was managed by TACE before or after radiotherapy. Results: Median patient age was 52 years old, and 88.1% of patients were male. Main or bilateral PVTT was observed in 200 (48.5%) patients. Median radiation dose was 40 Gy (range, 21-60 Gy) delivered in 2- to 5-Gy fractions. We found that 3.6% of patients achieved a complete response and that 24.3% of patients achieved a partial response. The response and progression-free rates of PVTT were 39.6% and 85.6%, respectively. Median patient survival was 10.6 months, and the 1- and 2-year survival rates were 42.5% and 22.8%, respectively. Significant independent variables associated with overall survival included advanced tumor stage, alpha-fetoprotein level, degree of PVTT, and response to radiotherapy. Forty-one patients (10.0%) showed grade 3-4 hepatic toxicity during or 3 months after completion of radiotherapy. Grades 2-3 gastroduodenal complications were observed in 15 patients (3.6%). Conclusions: Radiotherapy is a safe and effective treatment for PVTT in patients with HCC. These results suggested that the combination of TACE and radiotherapy is a treatment option for relieving and/or stabilizing PVTT in patients with advanced HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic Prostate Tracking and Motion Assessment in Volumetric Modulated Arc Therapy With an Electronic Portal Imaging Device

Purpose: To assess the prostate intrafraction motion in volumetric modulated arc therapy treatments using cine megavoltage (MV) images acquired with an electronic portal imaging device (EPID). Methods and Materials: Ten prostate cancer patients were treated with volumetric modulated arc therapy using a Varian TrueBeam linear accelerator equipped with an EPID for acquiring cine MV images during treatment. Cine MV images acquisition was scheduled for single or multiple treatment fractions (between 1 and 8). A novel automatic fiducial detection algorithm that can handle irregular multileaf collimator apertures, field edges, fast leaf and gantry movement, and MV image noise and artifacts in patient anatomy was used. All sets of images (approximately 25,000 images in total) were analyzed to measure the positioning accuracy of implanted fiducial markers and assess the prostate movement. Results: Prostate motion can vary greatly in magnitude among different patients. Different motion patterns were identified, showing its unpredictability. The mean displacement and standard deviation of the intrafraction motion was generally less than 2.0 ± 2.0 mm in each of the spatial directions. In certain patients, however, the percentage of the treatment time in which the prostate is displaced more than 5 mm from its planned position in at least 1 spatial direction was 10% or more. The maximum prostate displacement observed was 13.3 mm. Conclusion: Prostate tracking and motion assessment was performed with MV imaging and an EPID. The amount of prostate motion observed suggests that patients will benefit from its real-time monitoring. Megavoltage imaging can provide the basis for real-time prostate tracking using conventional linear accelerators.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Clinical Experience Performing Patient Treatment Verification With an Electronic Portal Imaging Device Transit Dosimeter

Purpose: To prospectively evaluate a 2-dimensional transit dosimetry algorithm's performance on a patient population and to analyze the issues that would arise in a widespread clinical adoption of transit electronic portal imaging device (EPID) dosimetry. Methods and Materials: Eleven patients were enrolled on the protocol; 9 completed and were analyzed. Pretreatment intensity modulated radiation therapy (IMRT) patient-specific quality assurance was performed using a stringent local 3%, 3-mm γ criterion to verify that the planned fluence had been appropriately transferred to and delivered by the linear accelerator. Transit dosimetric EPID images were then acquired during treatment and compared offline with predicted transit images using a global 5%, 3-mm γ criterion. Results: There were 288 transit images analyzed. The overall γ pass rate was 89.1% ± 9.8% (average ± 1 SD). For the subset of images for which the linear accelerator couch did not interfere with the measurement, the γ pass rate was 95.7% ± 2.4%. A case study is presented in which the transit dosimetry algorithm was able to identify that a lung patient's bilateral pleural effusion had resolved in the time between the planning CT scan and the treatment. Conclusions: The EPID transit dosimetry algorithm under consideration, previously described and verified in a phantom study, is feasible for use in treatment delivery verification for real patients. Two-dimensional EPID transit dosimetry can play an important role in indicating when a treatment delivery is inconsistent with the original plan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Implementation of a Model-Based In Vivo Dose Verification System for Stereotactic Body Radiation Therapy–Volumetric Modulated Arc Therapy Treatments Using the Electronic Portal Imaging Device

Purpose: To report findings from an in vivo dosimetry program implemented for all stereotactic body radiation therapy patients over a 31-month period and discuss the value and challenges of utilizing in vivo electronic portal imaging device (EPID) dosimetry clinically. Methods and Materials: From December 2013 to July 2016, 117 stereotactic body radiation therapy–volumetric modulated arc therapy patients (100 lung, 15 spine, and 2 liver) underwent 602 EPID-based in vivo dose verification events. A developed model-based dose reconstruction algorithm calculates the 3-dimensional dose distribution to the patient by back-projecting the primary fluence measured by the EPID during treatment. The EPID frame-averaging was optimized in June 2015. For each treatment, a 3%/3-mm γ comparison between our EPID-derived dose and the Eclipse AcurosXB–predicted dose to the planning target volume (PTV) and the ≥20% isodose volume were performed. Alert levels were defined as γ pass rates <85% (lung and liver) and <80% (spine). Investigations were carried out for all fractions exceeding the alert level and were classified as follows: EPID-related, algorithmic, patient setup, anatomic change, or unknown/unidentified errors. Results: The percentages of fractions exceeding the alert levels were 22.6% for lung before frame-average optimization and 8.0% for lung, 20.0% for spine, and 10.0% for liver after frame-average optimization. Overall, mean (± standard deviation) planning target volume γ pass rates were 90.7% ± 9.2%, 87.0% ± 9.3%, and 91.2% ± 3.4% for the lung, spine, and liver patients, respectively. Conclusions: Results from the clinical implementation of our model-based in vivo dose verification method using on-treatment EPID images is reported. The method is demonstrated to be valuable for routine clinical use for verifying delivered dose as well as for detecting errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Are Lateral Electronic Portal Images Adequate for Accurate On-Line Daily Targeting of the Prostate? Results of a Prospective Study

The purpose of this report was to evaluate the magnitude of the error that would be introduced if only a lateral (LAT) portal image, as opposed to a pair of orthogonal images, was used to verify and correct daily setup errors and organ motion in external beam radiation therapy (EBRT) of prostate cancer. The 3-dimensional (3D) coordinates of gold markers from 12 consecutive prostate patients were reconstructed using a pair of orthogonal images. The data were re-analyzed using only the LAT images. Couch moves from the 2-dimensional (2D)-only data were compared with the complete 3D data set. The 2D-only data provided couch moves that differed on average from the 3D data by 2.3 {+-} 3.0, 0.0 {+-} 0.0, and 0.8 {+-} 1.0 mm in the Lat, AP, and SI directions, respectively. Along AP and SI axes, the LAT image provided positional information similar to the orthogonal pair. The error along the LAT axis may be acceptable provided lateral margins are large enough. A LAT-only setup protocol reduces patient treatment times and increases patient throughput. In most circumstances, with exceptions such as morbidly obese patients, acquisition of only a LAT image for daily targeting of the prostate will provide adequate positional precision.

62 RADIOLOGY AND NUCLEAR MEDICINE↗