Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Polarity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Polar Cap Area and Boundary Motion During Substorms

The area of the polar cap as a function of local time and substorm phase was measured using images from the Polar Ultraviolet Imager (UVI) for different interplanetary magnetic field (IMF) orientations during three substorms in January 1997. We measured changes in the polar cap area and motion of the poleward and equatorward boundary of the auroral oval as determined by UVI images. It was found that the polar cap boundary is strongly influenced by thinning of the oval, decrease in polar cap structures, the poleward expansion of the substorm at midnight and the fading of luminosity below the instrument sensitivity threshold. Generally these effects dominate over the latitudinal motion of the auroral oval at its equatorward edge. A new feature is that the polar cap region clears of precipitation during the substorm growth phase, which expands the size of the polar cap but may not necessarily be related to an expansion of the open flux. We present a new finding that the increase in polar cap area prior to onset and the decrease in the area following it are independent of the strength of the southward IMF component. For one case the polar cap area increased while the southward component of the IMF was no less than -0.5 nT. These observations have strong implications for models that use the polar cap area to estimate the magnitude of energy storage in the lobe magnetic field and loss during substorms.

Brittnacher, M.↗

Dynamics of the Auroral Luminosity Boundary of the Polar Cap During Substorms

The area of the polar cap during substorms has been measured using images from the Polar Ultraviolet Imager (UVI) for different interplanetary magnetic field (IMF) conditions. Changes in the poleward boundary of auroral luminosity have been analyzed in relation to substorm phase and IMF orientation. Reconnection models of flux transport into the polar cap during the substorm growth phase, and loss from the polar cap during the expansion phase, provide a framework by which these UVI observations can be analyzed. By comparison of the observations with the model predictions we can determine to what extent these models accurately predict the polar cap dynamics, and also where anomalous behavior calls for a new understanding of the dynamics beyond what these models provide. It was found that the polar cap boundary near noon and midnight usually shifted down in latitude by 1-2 degrees and 3-4 degrees respectively, increasing the area of the polar cap during the substorm growth phase as predicted. However, this growth phase phenomenon also unexpectedly occurs independently of the IMF Bz component, as shown for a substorm on January 9, 1997. The polar cap area also increased due to motion of the dawn and dusk aurora to lower latitudes, although the latitudinal shifts were asymmetric, not always concurrent, and continued well into the substorm expansion phase. The polar cap area decreased immediately following the expansion phase due to the poleward motion of the aurora on the nightside, consistent with the model prediction. What is not explained by the models is that the poleward auroral boundary in the nightside region sometimes reached very high latitudes (greater than 80 degrees MLat) greatly decreasing the polar cap area, independent of the magnitude of the substorm.

Brittnacher, M. J.↗

HST NICMOS Observations of the Polarization of NGC 1068

We have observed the polarized light at 2 microns in the center of NGC 1068 with HST (Hubble Space Telescope) NICMOS (Near Infrared Camera Multi Object Spectrometer) Camera 2. The nucleus is dominated by a bright, unresolved source, polarized at a level of 6.0 +/- 1.2% with a position angle of 122 degrees +/- 1.5 degrees. There are two polarized lobes extending tip to 8" northeast and southwest of the nucleus. The polarized flux in both lobes is quite clumpy, with the maximum polarization occurring in the southwest lobe at a level of 17% when smoothed to 0.23" resolution. The perpendiculars to the polarization vectors in these two lobes point back to the intense unresolved nuclear source to within one 0.076" Camera 2 pixel, thereby confirming that this source is the origin of the scattered light and therefore the probable AGN (Active Galactic Nuclei) central engine. Whereas the polarization of the nucleus is probably caused by dichroic absorption, the polarization in the lobes is almost certainly caused by scattering, with very little contribution from dichroic absorption. Features in the polarized lobes include a gap at a distance of about 1" from the nucleus toward the southwest lobe and a "knot" of emission about 5" northwest of the nucleus. Both features had been discussed by groundbased observers, but they are much better defined with the high spatial resolution of NICMOS. The northeast knot may be the side of a molecular cloud that is facing the nucleus, which cloud may be preventing the expansion of the northeast radio lobe at the head of the radio synchrotron-radiation-emitting jet. We also report the presence of two ghosts in the Camera 2 polarizers.

Simpson, Janet P.↗

Polar Cap Disturbances: Mesosphere and Thermosphere-Ionosphere Response to Solar-Terrestrial Interactions

The Polar Cap is the Upper-Atmosphere cum Mag-netosphere region which is enclosed by the poleward boundary of the Auroral Oval and is threaded by open geomagnetic tield lines. In this region, there is normally a steady precipition (Polar "drizzle") of low energy (w 300eV) electrons that excite optical emissions from the ionosphere. At times, enhanced ionization patches are formed near the Dayside Cusp regions that drift across the Polar Cap towards the Night Sector of the Auroral Oval. Discrete auroral arcs and auroras formed during Solar Magnetic Cloud (SMC)/Coronal Mass Ejection (CME) events are also observed in the Polar Cap. Spectrophotometric observations of all these Polar Cap phenomena provide a measure of the average energy as well a energy flux of the electrons precipitating in the Polar Cap region during these disturbances. Such measurements also point to modulations of the Polar Cap Mesosphere-Lower Thermosphere (MLT) air density and temperature by zonally symmetric tides whose Hough functions peak in the Polar region. MLT cooling during Stratospheric Warming events and their relation to Polar Vortex and associated Gravity wave activities are also observed at the Polar Cap sites.

Sivjee, G.↗

The Bess-Polar II Long Duration Flight Above Antarctica

The Balloon-borne Experiment with a Superconducting Spectrometer, BESS, has been developed to study elementary particle phenomena in the early universe through measurements of low energy antiprotons to investigate their origin and through a search for antihelium. The BESS collaboration carried out nine northern latitude flights between 1993 and 2002. BESS-Polar is an advanced program of the BESS collaboration to study these topics with much greater precision using long duration flights above Antarctica. The BESS-Polar spectrometer was successfully developed to accumulate much larger numbers of events during long duration flights around the South Pole. Approximately a factor of four reductions in the amount of material in the particle beam enables measurement of much lower energy antiprotons down to 100 MeV (at top of atmosphere). The first BESS-Polar flight (BESS-Polar I) of 8.5 days was carried out above Antarctica in December 2004. recording 900 million cosmic-ray events. The second BESS-Polar flight (BESS-Polar 11) was successfully carried out in the austral summer season of 2007-2008. Based on experience with BESS-Polar I, the spectrometer was improved in performance and achieved long term stability during the flight. A newly constructed magnet with a larger liquid He capacity and improved thermal insulation and an upgraded data storage system with larger capacity of hard disk drives (HDDs) enabled longer observation time. BESS-Polar II was launched on December 22, 2007 from Williams Field, McMurdo Station, in Antarctica. The spectrometer worked properly and observed cosmic rays for about 24.5 days at float altitude, recording 4.6 billion events on the HDDs until the limit of the magnet operation was reached on January 16, 2008. The flight was terminated and the spectrometer was safely landed on the West Antarctic ice sheet (1000 km from the South Pole) on January 21, 2008. Here, the BESS-Polar instrument is discussed, highlighting improvements made for BESS-Polar II, and overviews of the flight and performance are reported.

Sasaki, Makoto↗

Tracking the Martian CO2 Polar Ice Caps in Infrared Images

Researchers at NASA s Jet Propulsion Laboratory have developed a method for automatically tracking the polar caps on Mars as they advance and recede each year (see figure). The seasonal Mars polar caps are composed mainly of CO2 ice and are therefore cold enough to stand out clearly in infrared data collected by the Thermal Emission Imaging System (THEMIS) onboard the Mars Odyssey spacecraft. The Bimodal Image Temperature (BIT) histogram analysis algorithm analyzes raw, uncalibrated data to identify images that contain both "cold" ("polar cap") and "warm" ("not polar cap") pixels. The algorithm dynamically identifies the temperature that separates these two regions. This flexibility is critical, because in the absence of any calibration, the threshold temperature can vary significantly from image to image. Using the identified threshold, the algorithm classifies each pixel in the image as "polar cap" or "not polar cap," then identifies the image row that contains the spatial transition from "polar cap" to "not polar cap." While this method is useful for analyzing data that has already been returned by THEMIS, it has even more significance with respect to data that has not yet been collected. Instead of seeking the polar cap only in specific, targeted images, the simplicity and efficiency of this method makes it feasible for direct, onboard use. That is, THEMIS could continuously monitor its observations for any detections of the polar-cap edge, producing detections over a wide range of spatial and temporal conditions. This effort can greatly contribute to our understanding of long-term climatic change on Mars.

Wagstaff, Kiri L.↗

Linear Polarizer Design for Application in the Far-Ultraviolet Spectral Range

New mission concepts that are under consideration by NASA call for the design and implementation of Far Ultraviolet (FUV) polarizer technologies that have not been developed yet. A team that includes members from the NASA Goddard Space Flight Center (GSFC), Arizona State University (ASU), and Woodruff Consulting, worked on the design and development of a polarizer design that produce very high extinction ratios in the FUV spectral range (100-200 nm). This polarizer consists of reflecting light through a series of mirrors from a combination of two silicon carbide (SiC) and two lithium fluoride (LiF) crystals positioned at angles of incidence (relative to surface normal) close to the average LiF Brewster’s angle in the FUV. The output is a highly linearly polarized beam. This polarizer concept was fabricated and tested in the existing McPherson 225 Vacuum Ultraviolet (VUV) spectrometer located in the Optics Branch at NASA-GSFC. Initial testing using a MgF2 crystal at the Brewster’s angle as an analyzer has shown that this design can produce state-of-the-art extinction ratios at the Hydrogen Lyman-Alpha (Ly-α) wavelength of 121.6 nm, and that the measured extinction ratio of the two crossed polarizers, ≈114, is mostly limited by the MgF2 analyzer. A polarizer with such a performance at this wavelength has never been reported and it signifies a breakthrough in FUV polarization technology. The levels of effectiveness paired with the polarizer’s compact design allows for a new polarizer capability that would one day be implemented in a future FUV spectropolarimetry space mission.

Far Ultraviolet (FUV)↗

Exploring the Neutron Substructure with Advanced Polarized Helium-3 Targets (Or: How I Learned to Stop Worrying and Love Spectroscopy)

As we seek to understand the smallest, physical aspects of our universe, we cannot simply rely on our senses to probe the world around us as we did in the past. The smallest physical elements of our universe behave in strange, probabilistic ways and are completely invisible to the naked eye/ear/etc. So, we design clever experiments (such as scattering experiments) to probe these minute realms. Then, just as with the larger, observable world, we devise models and equations to describe what we think is happening. Due to the nature of the physical universe at the quantum scale and with the aid of symmetries such as Lorentz invariance, we can write down equations that describe the scattering, but the expressions contain functions, which we call ?form factors? and ?structure functions?, that we cannot compute from first principles. We can, however, formulate models that make predictions for these functions. By comparing our predictions with the observed data, we can gain insight into the validity of our models and thus a better physical understanding of what is happening at these minuscule scales. Studying the constituents inside of the nucleus of an atom adds another layer of difficulty if we can?t remove those components from the nucleus. This is the case with the neutron. When not bound in the nucleus with protons and other neutrons, the neutron will decay into a proton after about 15 minutes. So, we?re forced to study the neutron while it is still bound in the nucleus of an atom such as helium-3 (3He). For the last 1,000 years (rounding up), our group has developed high quality, polarized 3He targets made of an aluminosilicate glass. These targets are made in order to perform experiments at Jefferson Lab (JLab), experiments which let us determine the form factors and structure functions of the neutron by scattering polarized electrons from polarized neutrons (or rather polarized 3He). The specific experiments reported on in this thesis push the bounds of our understanding of the internal structure of the neutron. Good science is often about pushing experimental techniques to a new level. Toward that goal we study our polarized 3He targets both to advance the technology and to choose the best ones for our experiments. We do this using a process called nuclear magnetic resonance (NMR) to gauge the maximum polarization of a target and how fast the polarization decays with time. While these tests primarily provide us information that make analysis of our experimental scattering data possible, they also let us determine whether or not a target-cell is useful or even, dare I say, of spectacular quality. Our latest targets utilize a novel convection design allowing 3He to be polarized and quickly moved in front of the electron-beam, making it possible to use larger targets with higher electron-beam currents than ever before. This means more electrons scatter and we get more data. And by studying our targets in detail prior to using them in our experiments, we have found techniques to take effects which could have been detrimental to target quality and turn them to our advantage! It?s a real case of making lemonade out of lemons. We also use laser spectroscopy to study the absorption lines of alkali-metals in the target (potassium and rubidium, specifically). We add these alkali-metals to our target to facilitate polarizing the 3He. We can use the measurement of these pressure broadened absorption lines to determine the 3He density inside of the target with great precision. Historically, we understood the width of these lines would be dependent on the temperature of the target. Specifically, if I raise the temperature, the width should get bigger. I found that was not the case, which was very confusing at first, though very exciting now that I realize the data are self-consistent and suggestive of unexpected behavior. This thesis details the development of high quality, glass, polarized 3He targets for the 2020 An 1 /dn 2 and 2023 Gn E experiments, which utilized the first 3He convection targets and broke records in target quality. This thesis also covers the initial development of metal windows for the next-generation of 3He target-cells. Finally, this thesis documents the temperature dependence of the width of potassium (K) and rubidium (Rb) absorption lines as measured with laser spectroscopy.

Jantzi, Christopher↗

Accurate determination of the electron spin polarization in magnetized iron and nickel foils for Møller polarimetry

The Møller polarimeter in Hall A at Jefferson Lab in Newport News, VA, has provided reliable measurements of electron beam polarization for the past two decades. Past experiments have typically required polarimetry at the 1% level of absolute uncertainty which the Møller polarimeter has delivered. However, the upcoming proposed experimental program including MOLLER and SoLID have stringent requirements on beam polarimetry precision at the level of 0.4% (The MOLLER Collaboration, 2014; The SoLID collaboration, 2019), requiring a systematic re-examination of all the contributing uncertainties. Møller polarimetry uses the double polarized scattering asymmetry of a polarized electron beam on a target with polarized atomic electrons. The target is a ferromagnetic material magnetized to align the spins in a given direction. In Hall A, the target is a pure iron foil aligned perpendicular to the beam and magnetized out of plane parallel or antiparallel to the beam direction. The acceptance of the detector is engineered to collect scattered electrons close to 90° in the center of mass frame where the analyzing power is a maximum (-7/9). One of the leading systematic errors comes from determination of the target foil polarization. Polarization of a magnetically saturated target foil requires knowledge of both the saturation magnetization and g', the electron g-factor which includes components from both spin and orbital angular momentum from which the spin fraction of magnetization is determined. Target foil polarization has been previously addressed in a 1997 publication “A precise target for Møller polarimetry” by de Bever et al. (1997) at a level of precision sufficient for experiments up to this point. Several shortcomings with the previous published value require revisiting the result prior to MOLLER. Here, we utilize the existing world data to provide a best estimate for target polarization for both nickel and iron foils including uncertainties in magnetization, high-field and temperature dependence, and fractional contribution to magnetization from orbital effects. We determine the foil electron spin polarization at 294 K to be 0.08020 ± 0.00018 (@4 T applied field) for iron and 0.018845+/-0.000053 (@2 T applied field) for nickel. Finally, we conclude with a brief discussion of additional systematic uncertainties to Møller polarimetry using this technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarization-dependent electrocaloric and pyroelectric effects in ferroelectric BaTiO 3 thin films

In this paper we examine the influence of controllable polarization reversal and built-in electric fields on pyroelectric and electrocaloric effects in a BaTiO 3 thin film using a modified indirect method. We find that the magnitude of the sample's change in polarization with temperature is sensitive to the degree of polarization reversal. The pyroelectric response is small at low fractions of switched polarization and grows larger by several factors as larger fractions of polarization are reversed. This polarization reversal-sensitive pyroelectric behavior is the result of an internal built-in field, which has the effect of destabilizing low fractions of switched polarization and producing diminished pyroelectric effect. Greater fractions of switched polarization are more stable against backswitching and permit a larger pyroelectric response. Our findings highlight a characterization method for polarization-dependent pyroelectric effects in ferroelectric thin films, where built-in field effects are also present.

36 MATERIALS SCIENCE↗

Conceptual design of DIII-D experiments to diagnose the lifetime of spin polarized fuel

Abstract In magnetic fusion experiments, the cross sections for the D-T and D- 3 He fusion reactions are increased by as much as 50% if the fuel remains spin polarized parallel to the magnetic field. The goal of this study is to assess the feasibility of lifetime measurements of spin polarization, in magnetic fusion relevant conditions, on the DIII-D tokamak using relative changes in charged fusion product (CFP) loss measurements that depend upon the differential fusion cross section d σ /dΩ. Relative measurements that capture changes in the escaping CFP pitch, poloidal, and energy distributions are studied in two realistic TRANSP calculated plasma scenarios: (a) vector-polarized 3 He and D pellets are injected into a hot hydrogen plasma to produce thermonuclear reactions, and (b) a tensor-polarized deuterium pellet is injected into an L-mode hydrogen background plasma that includes unpolarized 3 He neutral beam injection. Ideal CFP signals in both scenarios show substantial pitch sensitivity to polarization for 14.7 MeV proton detection at a poloidal angle of − 56 ∘ (on the outer wall in the ion ∇ B direction), and strong sensitivity to polarization for 3.6 MeV alpha flux detection by an array of poloidal detectors. Energy-resolved measurements of 14.7 MeV protons are also sensitive to the degree of polarization for the − 56 ∘ port in the beam-plasma scenario. A realistic assessment of CFP signals in the thermonuclear scenario show count rates in the range of 2 × 10 4 cps for pitch-resolved proton detection and 2 × 10 5 cps for alpha flux measurements. Reduced chi-squared χ r 2 calculations show polarization lifetime measurements are feasible for either proton or alpha detection of both enhanced or suppressed polarization for the thermonuclear scenario. Measurements of gamma rays produced in the weak D + 3 He → γ + 5 Li branch complement the CFP measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Polarization fraction of Planck Galactic cold clumps and forecasts for the Simons Observatory

ABSTRACT We measure the mean-squared polarization fraction of a sample of 6282 Galactic cold clumps at 353 GHz, consisting of Planck Galactic cold clump (PGCC) catalogue category 1 objects [flux densities measured with signal-to-noise ratio (S/N) > 4]. At 353 GHz, we find the mean-squared polarization fraction, which we define as the mean-squared polarization divided by the mean-squared intensity, to be (4.79 ± 0.44) × 10−4 equation to an $11\, \sigma$ detection of polarization. We test if the polarization fraction depends on the clumps’ physical properties, including flux density, luminosity, Galactic latitude, and physical distance. We see a trend towards increasing polarization fraction with increasing Galactic latitude, but find no evidence that polarization depends on the other tested properties. The Simons Observatory, with angular resolution of order 1 arcmin and noise levels between 22 and $54\, \mu$K−arcmin at high frequencies, will substantially enhance our ability to determine the magnetic field structure in Galactic cold clumps. At $\ge 5\, \sigma$ significance, we predict the Simons Observatory will detect at least ∼12 000 cold clumps in intensity and ∼430 cold clumps in polarization. This number of polarization detections would represent a two orders of magnitude increase over the current Planck results. We also release software that can be used to mask these Galactic cold clumps in other analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Semi-inclusive deep-inelastic scattering on a polarized spin-1 target. II. Deuteron and spectator nucleon tagging

We develop the theoretical framework for semi-inclusive deep-inelastic scattering on a polarized spin-1 target and apply it to scattering on the polarized deuteron with spectator nucleon tagging. In Part I (previous article), we present the general form of the semi-inclusive cross section and polarization observables for the spin-1 target. In Part II (this article), we consider deep-inelastic scattering on the polarized deuteron with spectator nucleon tagging as a special case of target fragmentation. Methods of light-front quantization are employed to separate nuclear and hadronic structure in the high-energy process and achieve a composite description. The light-front wave function of the polarized deuteron is obtained from a rotationally covariant three-dimensional wave function in the center-of-mass frame of the proton-neutron system. The tagged structure functions are computed in the impulse approximation. The momentum and spin distribution of the active nucleon are controlled by the deuteron polarization and the detected spectator momentum (𝐷/𝑆 wave ratio). The cross section and spin asymmetries are evaluated for general deuteron polarization (vector and tensor, longitudinal and transverse) as functions of the spectator momentum. Tensor-polarized spin asymmetries of order unity are achieved for spectator momenta of approximately 300 MeV, which select configurations with a large 𝐷 wave. Sum rules for the tagged spin structure functions are derived. The results can be used for simulations of spectator tagging in future polarized fixed-target experiments (Jefferson Lab) or at the Electron-Ion Collider.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A New Linear Polarizer Design for Application in the Far-Ultraviolet Spectral Range

New mission concepts that are under consideration by NASA (such as the Polstar MIDEX mission concept) call for the design and implementation of Far Ultraviolet (FUV) polarizer technologies that have not been developed yet. A team that includes members from the NASA Goddard Space Flight Center (GSFC), Arizona State University (ASU), and Woodruff Consulting, worked on the design and development of a polarizer design that may produce extinction ratios higher than have ever been reported before in the FUV spectral range (100-200 nm). This polarizer consists of transmitting linearly polarized light through a series of reflections from a combination of two silicon carbide (SiC) and two lithium fluoride (LiF) crystals positioned at angles of incidence (relative to surface normal) close to the LiF Brewster’s angle. The performance of this polarizer concept was fabricated and tested with an existing McPherson 225 Vacuum Ultraviolet (VUV) spectrometer located in the Optics Branch at NASA-GSFC. Initial testing has shown that in the FUV spectral range, this design can produce state-of-the-art extinction ratios at the Hydrogen Lyman-Alpha (Ly-α) wavelength of 121.6 nm. A polarizer with such a performance has never been reported and it signifies a breakthrough in FUV polarization technology. The levels of effectiveness paired with the design’s compact design allows for a new polarizer capability that would one day be implemented in a future spectropolarimetry space mission. In addition, this polarizer concept could potentially be used to characterize the optical properties of new mirror coatings that will be used in a future Habitable World Observatory (HWO) mission concept as proposed by the 2020 Decadal Survey.2

Far Ultraviolet (FUV), polarimetry, instrumentatio↗

Linear Polarizer Design for Application in the Far-Ultraviolet Spectral Range

New mission concepts that are under consideration by NASA (such as the Polstar MIDEX mission concept) call for the design and implementation of Far Ultraviolet (FUV) polarizer technologies that have not been developed yet. A team that includes members from the NASA Goddard Space Flight Center (GSFC), Arizona State University (ASU), and Woodruff Consulting, worked on the design and development of a polarizer design that may produce extinction ratios higher than have ever been reported before in the FUV spectral range (100-200 nm). This polarizer consists of transmitting linearly polarized light through a series of reflections from a combination of two silicon carbide (SiC) and two lithium fluoride (LiF) crystals positioned at angles of incidence (relative to surface normal) close to the LiF Brewster’s angle. The performance of this polarizer concept was fabricated and tested with an existing McPherson 225 Vacuum Ultraviolet (VUV) spectrometer located in the Optics Branch at NASA-GSFC. Initial testing has shown that in the FUV spectral range, this design can produce state-of-the-art extinction ratios at the Hydrogen Lyman-Alpha (Ly-α) wavelength of 121.6 nm. A polarizer with such a performance has never been reported and it signifies a breakthrough in FUV polarization technology. The levels of effectiveness paired with the design’s compact design allows for a new polarizer capability that would one day be implemented in a future spectropolarimetry space mission. In addition, this polarizer concept could potentially be used to characterize the optical properties of new mirror coatings that will be used in a future Habitable World Observatory (HWO) mission concept as proposed by the 2020 Decadal Survey.2

Far Ultraviolet (FUV), polarimetry, instrumentatio↗

X-ray and Multiwavelength Polarization of Mrk 501 Since 2022

We present multiwavelength polarization measurements for the luminous blazar Mrk 501 over a 14-month period. The 2 to 8 keV X-ray polarization was measured with the Imaging X-ray Polarimetry Explorer (IXPE) with six 100-ks observations spanning from March 2022 to June 2023. Each IXPE observation was accompanied with simultaneous X-ray data from NuSTAR, Swift/XRT, or XMM-Newton. Complementary optical polarization measurements were also available in the B,V,R,I, J bands as well as radio polarization measurements from 4.85 GHz to 225.5 GHz. Over the six IXPE observations, we find small to no variability in the X-ray polarization degree and angle with IXPE except for the most recent observation in June 2023 with slightly elevated polarization degree at ~3 sigma above the average of the other five observations. The optical and radio measurements show no apparent correlations to the X-ray polarization properties. This is consistent with the energy-stratified shock scenario established from the first two IXPE observations in which the polarized optical and radio emission is likely from different spatial regions than the polarized X-ray emission.

AGN↗

X-ray and Multiwavelength Polarization of Mrk 501 in 2022-2023

We present multiwavelength polarization measurements for the luminous blazar Mrk 501 over a 14-month period. The 2 to 8 keV X-ray polarization was measured with the Imaging X-ray Polarimetry Explorer (IXPE) with six 100-ks observations spanning from March 2022 to June 2023. Each IXPE observation was accompanied with simultaneous X-ray data from NuSTAR, Swift/XRT, or XMM-Newton. Complementary optical polarization measurements were also available in the B,V,R,I, J bands as well as radio polarization measurements from 4.85 GHz to 225.5 GHz. Over the six IXPE observations, we find small to no variability in the X-ray polarization degree and angle with IXPE except for the most recent observation in June 2023 with slightly elevated polarization degree at ~3 sigma above the average of the other five observations. The optical and radio measurements show no apparent correlations to the X-ray polarization properties. This is consistent with the energy-stratified shock scenario established from the first two IXPE observations in which the polarized optical and radio emission is likely from different spatial regions than the polarized X-ray emission.

AGN↗

Identifying Photoinduced Dipolar Polarization and Orbit–Orbit Interaction between Excitons in Organic–Inorganic Hybrid Perovskites

Abstract Photoinduced polarization and orbit–orbit interaction are important issues in hybrid perovskites toward developing optoelectronic functionalities. This paper identifies that photoinduced polarization occurs in hybrid perovskites with mixed‐cation methylammonium (MA)/formamidinium (FA) (MA x FA (1− x ) PbI 3 ) by measuring bulk polarization at 1 MHz in a magnetic field. Interestingly, when the internal dipole moment is increased upon increasing the MA:FA ratio, the photoinduced dipolar polarization can be substantially enhanced, clarifying the controversial issue of whether photoexcitation can induce a dielectric polarization within dipolar polarization regime in hybrid perovskites. Furthermore, upon increasing photoinduced dipolar polarization, it is found that the intrinsic orbit–orbit interaction between excitons can be increased, revealed by monitoring photocurrent change (Δ J sc ) upon switching the photoexcitation between linear and circular polarizations. This presents that organic cations are directly involved in the orbit–orbit interaction within band structures. Clearly, the studies provide an insightful understanding of the dipole moment effects on photoinduced dipolar polarization and orbit–orbit interaction between excitons in hybrid perovskites toward controlling the optoelectronic properties.

Dou, Yixuan↗