Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Plastic scintillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

265 records · Page 15

Use of relativistic rise in ionization chambers for measurement of high energy heavy nuclei

A balloon-borne instrument has been constructed to measure the energy spectra of cosmic-ray heavy nuclei in the range of about 0.3 to about 100 GeV/amu. It makes use of the relativistic rise portion of the Bethe-Bloch curve in ionization chambers for energy determination in the 10- to 100-GeV/amu interval. The instrument consists of six layers of dual-gap ionization chambers for energy determination above 10 GeV/amu. Charge is determined with a NE114 scintillator and a Pilot 425 plastic Cerenkov counter. A CO2 gas Cerenkov detector (1 atm; threshold of 30 GeV/amu) calibrates the ion chambers in the relativistic rise region. The main emphasis of the instrument is the determination of the change of the ratio of Iron (26) to the Iron secondaries (21-25) in the energy range of 10 to 100 GeV/amu. Preliminary data from a balloon flight in the fall of 1982 from Palestine, TX is presented.

Barthelmy, S. D.↗

Production and validation of scintillating structural components from low-background Poly(ethylene naphthalate)

Poly Ethylene Naphthalate (PEN) is an industrial polymer plastic which is investigated as a low background, transparent, scintillating and wavelength shifting structural material. PEN scintillates in the blue region and has excellent mechanical properties both at room and cryogenic temperatures. Thus, it is an ideal candidate for active structural components in experiments for the search of rare events like neutrinoless double-beta decay or dark matter recoils. Such optically active structures improve the identification and rejection efficiency of backgrounds events, like this improving the sensitivity of experiments. This paper reports on the production of radiopure and transparent PEN plates These structures can be used to mount germanium detectors operating in cryogenic liquids (LAr, LN). Thus, as first application PEN holders will be used to mount the Ge detectors in the LEGEND-200 experiment. The whole process from cleaning the raw material to testing the PEN active components under final operational conditions is reported.

47 OTHER INSTRUMENTATION↗

Neutron Measurements for Radiation Protection in Low Earth Orbit - History and Future

The neutron environment inside spacecraft has been of interest from a scientific and radiation protection perspective since early in the history of manned spaceflight. With 1:.1e exception of a few missions which carried plutonium-fueled radioisotope thermoelectric generators, all of the neutrons inside the spacecraft are secondary radiations resulting from interactions of high-energy charged particles with nuclei in the Earth's atmosphere, spacecraft structural materials, and the astronaut's own bodies. Although of great interest, definitive measurements of the spacecraft neutron field have been difficult due to the wide particle energy range and the limited available volume and power for traditional techniques involving Bonner spheres. A multitude of measurements, however, have been made of the neutron environment inside spacecraft. The majority of measurements were made using passive techniques including metal activation fo ils, fission foils, nuclear photoemulsions, plastic track detectors, and thermoluminescent detectors. Active measurements have utilized proton recoil spectrometers (stilbene), Bonner Spheres eRe proportional counter based), and LiI(Eu)phoswich scintillation detectors. For the International Space Station (ISS), only the plastic track! thermoluminescent detectors are used with any regularity. A monitoring program utilizing a set of active Bonner spheres was carried out in the ISS Lab module from March - December 200l. These measurements provide a very limited look at the crew neutron exposure, both in time coverage and neutron energy coverage. A review of the currently published data from past flights will be made and compared with the more recent results from the ISS. Future measurement efforts using currently available techniques and those in development will be also discussed.

Golightly, M. J.↗

Steps toward FNCL Cell Replacement (FY2021 Mid-Year Annual Report)

Evaluate compact replacement cells for the Fast Neutron Collar (FNCL). The current cells are 4x4x4 in 3 of EJ-309 instrumented with 8” tall PMTs, and the replacements are 4x4x3 in 3 cells instrumented with 1” tall SiPM arrays. The replacement cell materials are stilbene (organic crystal), EJ-309 (liquid scintillator), and EJ-299-33M (PSD-capable plastic).

42 ENGINEERING↗

The Apollo gamma-ray spectrometer

A gamma-ray spectrometer has been flown on the Apollo 15 and 16 spacecraft to determine the lunar-surface composition and measure the cosmic gamma-ray flux. The instrument included a NaI(Tl) scintillation crystal coupled to a 7.6-cm photomultiplier tube, a plastic mantle for anti-coincidence rejection of charged particles, and 511 channels of analysis. Boom-mounted operation permitted a significant reduction in the background. The data were transmitted on an event-by-event basis. About 22% of the lunar surface was mapped and spectra of the cosmic gamma-ray flux over an energy range of 0.065-27.5 MeV have been obtained.

Harrington, T. M.↗

Low Level Calibration of Liquid Scintillation Counting

Liquid Scintillation Counting (LSC) is an analytical laboratory method that quantifies the concentrations of alpha and beta emitting isotopes. The LSC method can be utilized for the detection of tritium, both environmentally and at nuclear facilities. Most LSC samples are aqueous-based and prepared as a radioactive sample dissolved or suspended in a high efficiency scintillation cocktail that converts radioactive energy into light pulses. When placed in counting vials, the liquid scintillation cocktail allows for optical coupling in which energy is released from the samples radioactive decay, and transferred to the scintillator. That energy is then absorbed to produce excited electrons that fall back to their ground-state and emit a pulse of light that is detected by the liquid scintillation analyzers photomultiplier tubes. Quench is a signal attenuation due to physical, chemical, or color interferences. To compensate for quench, quench standards of a known concentration are implemented at increasing increments of quench per vial to create a quench curve. Quench standards can be purchased pre-made or customized from the manufacturer, however, there are several issues that arise from purchasing the pre-made quench standards. The main issues with ordering pre-made quench standards is that they use higher count values, between 30,000 and 250,000 disintegrations per minute (dpm) of tritium per vial and only come in glass vials. Using higher counting standards in glass vials makes it hard to see lower concentrations in plastic vials. Additionally, when using higher energy standards the accuracy of the calibration readings tend to be lower. On the other hand, making a set of quench standards in-house allows for the customization of the dpm concentration to roughly 1,500-3,000 and preparation in plastic vials. This allows for lower activity readings that results in closer precision of the samples' true concentration. Technical Objectives: Create a quench curve and calibrate the LSA for tritium. Verify the calibration of the quench curve prior to cross sample runs. Check calibration against Quality Control (QC) reference value. Conclusion: a tritium quench curve calibration was performed using a scintillation cocktail with ultima gold (AB and AB/F), acetone (only with AB), and water (only with AB/F). By performing the tritium quench curve calibration, the counting efficiency was correlated to various levels of quench. Calibration checks with quality control standards were also performed to verify that the calibration was correct. The observed results provided acceptable values that matched the quality control standard reference values with an acceptable uncertainty. The next step will be fine tuning and cross comparison checks with legacy instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thin-film scintillators for extended ultraviolet /UV/ response silicon detectors

The preparation and radiometric properties of silicon detectors coated with fluorescent thin films are described. The films are deposited from solutions of clear plastics, such as acrylic resins, polyvinyl toluene or polystyrene, and of organic laser dyes in a common solvent. They are optically clear, mechanically and chemically stable, yet easily applied and removed. Multiple doped films of a few microns thickness exhibit broad-band absorption from less than 250 nm to about 450 nm and narrow band emissions with peaks ranging from 380 nm to 600 nm. Internal quantum efficiencies are close to 100 percent and fluorescence decay times are in the nanosecond range. When deposited on optically denser media, a large fraction of the fluorescent emission is trapped in the substrate. Silicon photodiodes coated with multiple doped films exhibit high external quantum efficiencies and virtually flat photon response in the near UV.

Viehmann, W.↗

Machine learning in nuclear materials research

Nuclear materials are often demanded to function for extended time in extreme environments, including high radiation fluxes with associated transmutations, high temperature and temperature gradients, mechanical stresses, and corrosive coolants. They also have a wide range of microstructural and chemical makeups, resulting in multifaceted and often out-of-equilibrium interactions. Machine learning (ML) is increasingly being used to tackle these complex time-dependent interactions and aid researchers in developing models and making predictions, sometimes with better accuracy than traditional modeling that focuses on one or two parameters at a time. Conventional practices of acquiring new experimental data in nuclear materials research are often slow and expensive, limiting the opportunity for data-centric ML, but new methods are changing that paradigm. Here we review high-throughput computational and experimental data approaches, especially robotic experimentation and active learning that is based on Gaussian process and Bayesian optimization. We show ML examples in structural materials (e.g., reactor pressure vessel (RPV) alloys and radiation detecting scintillating materials) and highlight new techniques of high-throughput sample preparation and characterizations, and automated radiation/environmental exposures and real-time online diagnostics. Herein, this review suggests that ML models of material constitutive relations in plasticity, damage, and even electronic and optical responses to radiation are likely to become powerful tools as they develop. Finally, we speculate on how the recent trends of using natural language processing (NLP) to aid the collection and analysis of literature data, interpretable artificial intelligence (AI), and the use of streamlined scripting, database, workflow management, and cloud computing platforms that will soon make the utilization of ML techniques as commonplace as the spreadsheet curve-fitting practices of today.

36 MATERIALS SCIENCE↗

Cherenkov-dE/dx-range measurements on cosmic ray iron group nuclei

A balloon experiment which combined a large area plastic detector unit with electronic dE/dx-C data is presented. The correlation of the electronic data with the range data of the plastic detector stack was achieved by rotating plastic detector disks which provided in this way the passive plastic detector with an incorporated time determination. The constant flux of cosmic ray particles with charge Z greater than two was used to gauge the time resolving system. Stopping cosmic ray iron group nuclei in the energy range 400 to 700 MeV/nuc are identified using their electronic scintillator and Cherenkov signals and their etch conelengths and range data. The precise knowledge of the particle's trajectory proposes refined pathlength corrections to the electronic data.

Sermund, G.↗

The GRAD high-altitude balloon flight over Antarctica

The Gamma Ray Advanced Detector (GRAD) consists of a n-type germanium detector inside an active bismuth-germanate Compton and charged particle shield with additional active plastic shielding across the aperture. It will be flown on a high-altitude balloon at 36 km altitude at a latitude of 78 deg S over Antarctica for observations of gamma radiation emitted by the radioactive decay of Co-56 in the supernova SN1987A, for assessment of the performance of bismuth-germanate scintillation material in the radiation environment of near space, for gathering information on the gamma-ray background over Antarctica, and for testing fault-tolerant software.

Eichhorn, G.↗

Real-time observation of X-ray diffraction patterns with the Lixiscope

The feasibility of the Lixiscope (Low Intensity X-ray Imaging Scope) is demonstrated for real-time observation of transmission Laue patterns. Making use of the high-gain capability of microchannel plate (MCP) visible-light image intensifier tubes, X-ray images are converted to visible-light images by a scintillator. Pb discs are taped to the center of the Lixiscope input face, and crystal samples are held on a goniometer stage with modeling clay. With a compact size to facilitate off axis viewing, and real-time viewing to allow instantaneous response, the Lixiscope may prove useful in dynamic studies of the effects of plastic flows, stresses, high pressures, and low temperatures.

Chung, D. Y.↗

Development, construction and tests of the Mu2e electromagnetic calorimeter mechanical structures

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the charged lepton flavour violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of the existence of physics beyond the standard model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. In particular, the calorimeter provides excellent electron identification, a fast calorimetric online trigger, and complementary information to aid pattern recognition and track reconstruction. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total expected ionizing dose of 12 krad and a neutron fluence of 5 × 10$^{10}$ n/cm$^{2}$ @ 1 MeV$_{eq}$ (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on scintillating materials, sensors, electronics and on the design of the detector mechanical structures and material choice. The support structure of each 674 crystal matrix is composed of an aluminum hollow ring and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and front-end electronics for the readout of each crystal are inserted in a machined copper holder and make a unique mechanical unit. The resulting 674 mechanical units are supported by a machined plate of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics are hosted in aluminum custom crates positioned on the external lateral surface of the disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system. In this paper we report on the calorimeter mechanical structure design, the mechanical and thermal simulations that have determined the design technological choices, and the status of component production, quality assurance tests and plans for assembly at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗