Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Rating Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Numerical study of the effects of icing on viscous flow over wings

The progress made during the period 1 Jan. - 30 Jun. 1993 on the numerical study of the effects of icing on viscous flow over wings is summarized. The tasks performed were development of 3-D boundary layer methods for accurate estimates of the velocity field and surface heat transfer rates in the vicinity of the leading edge ice shape; studies of the effects of icing on 3-D highlift system performance; and continued improvement and validation of the 3-D Navier-Stokes solver. Results are discussed.

Sankar, L. N.↗

Manipulation of mass transport rates using bead-in-a-tube method

In ultralow Pu analyses, the gold standard is thermal ionization mass spectrometry (TIMS), which requires pure sources to achieve its performance. This purity is achieved through step-wise purifications. In this work single anion-exchange beads were trapped in tubing to allow for dynamic solution cycling over the surface of the beads to improve the rates of metal complex uptake. Rates of Pu sorption on single ~900 µm SIR-1200 and ~620 µm Reillex-HPQ beads were determined for single beads trapped in a tube with syringe pump driven dynamic solution cycling over the bead, improving sorption and desorption rates. A static control was used as a comparison. Using 238Pu to enable facile activity-based measurements, rates were determined by measuring the residual Pu after contact with beads using liquid scintillation analysis (LSA) for fixed periods of time. Syringe pump driven dynamic solution cycling results in ~5 and ~15-fold improvements in the sorption rates for SIR-1200 and Reillex-HPQ. Impacts on desorption were also examined.

Bead-in-a-tube, Mass Transport Rates↗

An Effectively Activated Hierarchical Nano-/Microspherical Li 1.2 Ni 0.2 Mn 0.6 O 2 Cathode for Long-Life and High-Rate Lithium-Ion Batteries

Rechargeable lithium-ion batteries with high energy and high power density are required in the application of electric vehicles and portable electronics. Herein, we introduce a type of spherical Li-rich cathode material, Li1.2Ni0.2Mn0.6O2, assembled from uniform nanocubes by a facile polyvinylpyrrolidone (PVP)-assisted hydrothermal method. The material with a hierarchical nano-/microstructure exhibits stable high-rate performance. Furthermore, the precipitant (i.e., urea) and the structure-directing agent (i.e., PVP) effectively activated the Li2MnO3 components in the microscale material to achieve a high specific capacity of 298.5 mAh g-1 in the first cycle. This Li-rich cathode material still delivered 243 mAh g-1 at 0.1 C after 200 cycles and the capacity retentions at 0.5, 1, 2, and 5mC were 94.4, 78.7, 76.3, and 67.8 % after 150 cycles, respectively. The results make this Li-rich nano-/microstructure a promising cathode material for long-life and high-performance lithium-ion batteries.

25 ENERGY STORAGE↗

Improved thermonuclear rate of 42 Ti( p , γ ) 43 V and its astrophysical implication in the rp process

Context. Accurate 42 Ti(p,γ) 43 V reaction rates are crucial for understanding the nucleosynthesis path of the rapid capture process (rp process) that occurs in X-ray bursts. Aims. We aim to improve the thermonuclear rates of 42 Ti(p,γ) 43 V based on more complete resonance information and a more accurate direct component, together with the recently released nuclear masses data. We also explore the impact of the newly obtained rates on the rp process. Methods. We reevaluated the reaction rate of 42 Ti(p,γ) 43 V by the sum of the isolated resonance contribution instead of the Hauser-Feshbach statistical model. We used a Monte Carlo method to derive the associated uncertainties of new rates. The nucleosynthesis simulations were performed via the NuGrid post-processing code ppn. Results. The new rates differ from previous estimations due to the use of a series of updated resonance parameters and a direct S factor. Compared with the previous results from the Hauser-Feshbach statistical model, which assumes compound nucleus 43 V with a sufficiently high-level density in the energy region of astrophysical interest, large differences exist over the entire temperature region of rp-process interest, up to two orders of magnitude. We consistently calculated the photodisintegration rate using our new nuclear masses via the detailed balance principle, and found the discrepancies among the different reverse rates are much larger than those for the forward rate, up to ten orders of magnitude at the temperature of 10 8 K. Using a trajectory with a peak temperature of 1.95×10 9 K, we performed the rp-process nucleosynthesis simulations to investigate the impact of the new rates. Our calculations show that the adoption of the new forward and reverse rates result in abundance variations for Sc and Ca of 128% and 49%, respectively, compared to the variations for the statistical model rates. On the other hand, the overall abundance pattern is not significantly affected. The results of using new rates also confirm that the rp-process path does not bypass the isotope 43 V. Conclusions. Our study found that the Hauser-Feshbach statistical model is inappropriate to the reaction rate evaluation for 42 Ti(p,γ) 43 V. The adoption of the new rates confirms that the reaction path of 42 Ti(p,γ) 43 V(p,γ) 44 Cr(β + ) 44 V is a key branch of the rp process in X-ray bursts.

79 ASTRONOMY AND ASTROPHYSICS↗

High-resolution whole-brain DCE-MRI using constrained reconstruction: Prospective clinical evaluation in brain tumor patients

Purpose: To clinically evaluate a highly accelerated T1-weighted dynamic contrast-enhanced (DCE) MRI technique that provides high spatial resolution and whole-brain coverage via undersampling and constrained reconstruction with multiple sparsity constraints. Methods: Conventional (rate-2 SENSE) and experimental DCE-MRI (rate-30) scans were performed 20 minutes apart in 15 brain tumor patients. The conventional clinical DCE-MRI had voxel dimensions 0.9 × 1.3 × 7.0 mm{sup 3}, FOV 22 × 22 × 4.2 cm{sup 3}, and the experimental DCE-MRI had voxel dimensions 0.9 × 0.9 × 1.9 mm{sup 3}, and broader coverage 22 × 22 × 19 cm{sup 3}. Temporal resolution was 5 s for both protocols. Time-resolved images and blood–brain barrier permeability maps were qualitatively evaluated by two radiologists. Results: The experimental DCE-MRI scans showed no loss of qualitative information in any of the cases, while achieving substantially higher spatial resolution and whole-brain spatial coverage. Average qualitative scores (from 0 to 3) were 2.1 for the experimental scans and 1.1 for the conventional clinical scans. Conclusions: The proposed DCE-MRI approach provides clinically superior image quality with higher spatial resolution and coverage than currently available approaches. These advantages may allow comprehensive permeability mapping in the brain, which is especially valuable in the setting of large lesions or multiple lesions spread throughout the brain.

60 APPLIED LIFE SCIENCES↗

Searches for a sterile-neutrino admixture in detecting tritium decays in a proportional counter: New possibilities

An experiment aimed at searches for an admixture of a sterile neutrino whosemass is 1 to 8 keV via detecting electrons from tritium decay in a proportional counter is proposed. The admixture in question can be discovered by a specific distortion of the energy spectrum of these electrons. For the above masses, the distortion extends over the whole spectrum; therefore, use can bemade of detectors that have a relatively low energy resolution (about 10 to 15%). A classic proportional counter is a simple and natural choice of detector for the decays of a gaseous tritium. The approach that we propose is novel in two respects. On one hand, the proportional counter used is made as a discrete unit in the form of a fully fused quartz tube. This permits a readout of current signals directly from the anode filament and ensures a high stability in the case of long-term measurements. At the same time, the application of state-of-the-art digital data-acquisition methods will make it possible to perform measurements under conditions of high counting rates—up to 10{sup 6} Hz. As a result, the energy spectrum of electrons from tritium decays that is formed by 10{sup 12} counts could be accumulated within about a month. This data sample would make it possible to set an upper limit in the range of 10{sup −3}–10{sup −5} on a sterile-neutrino admixture at a confidence level of three standard deviations (3σ) for m{sub s} in the range of 1–8 keV, this being one to two orders of magnitude more stringent than present-day limits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fluid dynamic simulation and analysis of water-cooling systems for the Electron-Ion Collider

The Electron-Ion Collider is the newest large-scale project at Brookhaven National Laboratory. The collider’s purpose is to provide further advancements in the knowledge of the universe’s origin by accelerating particles near the speed of light. Our project for this 3.8 km ring was to create a thermal hydraulic steady-state simulation design of the water-cooling system to be cost-effective and energy efficient, as envisioned by Charlie Foltz, the EIC Infrastructure Division Director. The system would include a supply and return header, which cools several thousand components of the ring. The water would then be returned and cooled down using a system of cooling towers and plate and frame heat exchangers. Due to the size of the system and the complexity of the network analysis, a fluid dynamic simulation software, AFT Fathom, was used. Since previous methods of maintaining systems relied on building upon smaller real-life models and implementing empirical data, this flow model was unique and first of a kind in the domain of accelerator design, construction and operation. Therefore, our hydraulic team piloted a new method to perform network analysis on a large scale cooling system. We successfully created several test scenarios for system behavior in a shorter time compared to the method of performing hand calculations. Cooling specifications for heat rejection, pressure drop, flow rate, and pipe sizing were changed based on the individual systems of the vacuum, radio frequency (RF), magnet and power supply, and cryogenics sections. Finally, we used DOE guidelines to perform life-cycle cost analysis with net present value and carbon saving analysis on the systems where pipe size could be optimized.

43 PARTICLE ACCELERATORS↗

Design Optimization Tool for Synthetic Jet Actuators Using Lumped Element Modeling

The performance specifications of any actuator are quantified in terms of an exhaustive list of parameters such as bandwidth, output control authority, etc. Flow-control applications benefit from a known actuator frequency response function that relates the input voltage to the output property of interest (e.g., maximum velocity, volumetric flow rate, momentum flux, etc.). Clearly, the required performance metrics are application specific, and methods are needed to achieve the optimal design of these devices. Design and optimization studies have been conducted for piezoelectric cantilever-type flow control actuators, but the modeling issues are simpler compared to synthetic jets. Here, lumped element modeling (LEM) is combined with equivalent circuit representations to estimate the nonlinear dynamic response of a synthetic jet as a function of device dimensions, material properties, and external flow conditions. These models provide reasonable agreement between predicted and measured frequency response functions and thus are suitable for use as design tools. In this work, we have developed a Matlab-based design optimization tool for piezoelectric synthetic jet actuators based on the lumped element models mentioned above. Significant improvements were achieved by optimizing the piezoceramic diaphragm dimensions. Synthetic-jet actuators were fabricated and benchtop tested to fully document their behavior and validate a companion optimization effort. It is hoped that the tool developed from this investigation will assist in the design and deployment of these actuators.

Gallas, Quentin↗

Comparison and Application of Battery Modeling Methods for Conceptual Electric Aircraft

Growing interest in design and optimization of electrified aircraft propulsion concepts prompts the need for accurate, flexible, and efficient methods to model battery systems. Presented in this paper are three battery modeling methods that have been used at NASA’s Glenn Research Center, each representing different mathematical or electrical approaches. Thévenin equivalent circuit, normalization, and curve-fitting methods are compared against battery cell test data for the X-57 Maxwell electric aircraft technology demonstrator. The methods are then applied in a simple multidisciplinary optimization context using NASA’s Six-Passenger Electric Quadrotor concept to determine their applicability and performance. The normalization method achieves the highest accuracy for steady and unsteady discharge rates with a voltage mean error percentage of 0.423% and 1.186%, respectively. Optimal quadrotor mission range between the models varies up to 0.5 nmi, identifying current battery modeling methods as a potentially significant contributor to mission analysis error. A set of relevant tools and techniques for conceptual battery modeling are identified in this paper, with conclusions made on the utility of each modeling approach for various design challenges.

power↗

Characterizing Radiation-Induced Chromium Redox Chemistry

The redox behavior of Cr(III) and Cr(VI) in nuclear environments were studied by analyzing aqueous irradiated chromium ions using UV-Visible spectroscopy. The formation of different chromium oxidation states can occur through gamma radiolysis of chromium solutions. Characterization of radiation-induced chromium is not well understood, and yet important as chromium can make its way into the primary coolant of reactors because of the corrosion of stainless steel reactor components. Furthermore, Cr(VI) is toxic and not suitable for environmental release, therefore Cr speciation is important. Fricke dosimetry was performed to collect doses rates, specific extinction coefficients were obtained from various analytical methods for the two oxidation states of chromium. Chromium samples--conditioned at various pH's and concentration to understand the effects--were then irradiated using a Coblat-60 gamma irradiator. Three optical spectroscopy analytical methods were used , including direct oxidation state measurements and complexation by either EDTA or DPC. Complexation by EDTA was found to not be a reliable method. Radiolytic oxidation of Cr(III) to Cr(VI), and reduction of Cr(VI) to Cr(III) were clearly seen, except for Cr(III) samples were a pH less than or equal to 2, where no change occurred.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A performant energy-conserving particle reweighting method for Particle-in-Cell simulations

A new particle-based reweighting method is developed and demonstrated in the Aleph Particle-in-Cell with Direct Simulation Monte Carlo (PIC-DSMC) program. Novel splitting and merging algorithms ensure that modified particles maintain physically consistent positions and velocities. This method allows a single reweighting simulation to efficiently model plasma evolution over orders of magnitude variation in density, while accurately preserving energy distribution functions (EDFs). Demonstrations on electrostatic sheath and collisional rate dynamics show that reweighting simulations achieve accuracy comparable to fixed weight simulations with substantial computational time savings. This highly performant reweighting method is recommended for modeling plasma applications that require accurate resolution of EDFs or exhibit significant density variations in time or space.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of the apparent thermal conductivity of multi-layer insulation between 20 K and 90 K

NASA has the need to efficiently store cryogenic propellants in space for long periods of time. One method to improve storage efficiency is to use multi-layer insulation (MLI), a technique that minimizes the boiling rate due to radiation heat transfer. Typically, the thermal performance of MLI is determined by measuring the rate of evaporation of liquid nitrogen from a calibrated cryostat. The main limitation with this method is that testing conditions are restricted by the boiling temperature of the LN{sub 2}, which may not match the requirements of the application. The Multi-Layer Insulation Thermal Conductivity Experiment (MIKE) at the National High Magnetic Field Laboratory is capable of measuring the effective thermal conductivity of MLI at variable boundary temperatures. MIKE uses cryo-refrigerators to control boundary temperatures in the calorimeter and a calibrated thermal link to measure the heat load. To make the measurements requested by NASA, MIKE needed to be recalibrated for the 20 K to 90 K range. Also, due to the expectation of a lower heat transfer rate, the heat load support rod material was changed to one with a lower thermal conductivity to ensure the temperature difference seen on the cold rod could be measurable at the estimated heat load. Presented are the alterations to MIKE including calibration data and heat load measurements on new load-bearing MLI supplied by NASA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flight evaluation of height response characteristics for the hover bob-up task and comparison with proposed criteria

The CH-47B variable-stability helicopter was used to evaluate a range of height-response configurations while performing a precision hover bob-up task. The purpose of the study was to assess the validity of results obtained in previous ground-based and in-flight simulations in the context of a precision bob-up task and to provide additional flight data for inclusion in revisions to specifications for helicopter handling qualities. Height response characteristics were implemented using explicit model-following techniques, and the resulting CH-47B dynamics were validated using time-domain and frequency-domain data-analysis methods. The tests complemented the previous investigations by providing detailed pilot comments and ratings, and performance and control-utilization data that relate exclusively to the hover bob-up task. The results are compared with those from previous investigations and with new criteria that have been proposed for handling qualities requirements for helicopters.

Hindson, W. S.↗

Comparison of Heterogeneous Hydroformylation of Ethylene and Propylene over RhCo 3 /MCM-41 Catalysts

The reaction mechanisms of heterogenous hydroformylation of ethylene and propylene were compared at 413-453 K using RhCo 3 /MCM-41 as catalysts. The reaction rates of propylene for both hydroformylation and the undesired side reaction of hydrogenation were found to be about one order of magnitude lower than those for ethylene in flow reactor studies. The difference in the kinetic behavior between ethylene and propylene was investigated by measuring the reaction orders and apparent activation energies, and these macro-kinetic observables were analyzed using the degree of rate control (DRC) method. In situ diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) experiments were performed to characterize the surface intermediates formed during the reactions. When the reactant was changed from ethylene to propylene, the IR peak corresponding to adsorbed CO exhibited a significant increase, while the IR peaks of alkyl group decreased in magnitude. Combined with the DRIFTS results, DRC analysis indicates that the first step of olefin hydroformylation, the formation of an alkyl group on the catalyst surface, plays a key role in the difference between ethylene and propylene. This step is kinetically non-relevant when ethylene is the reactant, but it is one of the rate-controlling steps for propylene. Furthermore, the low concentration of the adsorbed propyl group, which is a common intermediate shared by both hydroformylation and hydrogenation of propylene, decreases the rates of both reaction pathways as compared to ethylene.

10 SYNTHETIC FUELS↗

Electrochemical Ammonia Compression

An electrochemical (EC) compressor is a solid-state compression device. For decades, researchers have been studying EC compressors for applications for a variety of energy systems. As the world transitions away from fossil fuel energy sources, EC compression emerges as a promising technique for energy storage, specifically energy stored in the form of pressurized ammonia. Ammonia is also a commonly used refrigerant. The present studies examine the viability of EC compression for ammonia storage and refrigeration. EC ammonia compression increases the concentration of an ammonia-hydrogen mixture via the input of electrical energy and a series of chemical reactions. A polymer electrolyte membrane separates the low-concentration side from the high-concentration side of the device. On the low-pressure (anode) side hydrogen atoms oxidize and react with ammonia molecules, forming positively charge ammonium ions. The ions traverse the membrane electrolytically. The ammonium ions are reduced and revert back to hydrogen and ammonia upon reaching the high-pressure (cathode). An external circuit provides the current needed to sustain the reactions. In this project, we studied the performance of the ammonia EC compressor under a variety of different conditions. We replicated preliminary data and using a small cell with 5 cm2 of active area. We demonstrated the operation of larger cells with 100 cm2 of active area. Further, we used a commercially available hydrogen EC compressor stack to analyze the scaled-up compressor performance. While previous experiments examined only the transient EC compressor performance, we developed test facilities that allowed the compressor to reach steady state. We analyzed the effects of pressure and current on the EC compressor performance. We measured the flow rates of gas leaving the compressors and analyzed the composition using gas chromatography. We tested methods of separating ammonia from the effluent vapor, which contained hydrogen and water vapor. We found that back diffusion adversely affected the performance, especially when we maintained high pressure lifts.

25 ENERGY STORAGE↗

General methods for determining the linear stability of coronal magnetic fields

A time integration of a linearized plasma equation of motion has been performed to calculate the ideal linear stability of arbitrary three-dimensional magnetic fields. The convergence rates of the explicit and implicit power methods employed are speeded up by using sequences of cyclic shifts. Growth rates are obtained for Gold-Hoyle force-free equilibria, and the corkscrew-kink instability is found to be very weak.

Craig, I. J. D.↗

NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system

Purpose: The GE SIGNA PET/MR is a new whole body integrated time-of-flight (ToF)-PET/MR scanner from GE Healthcare. The system is capable of simultaneous PET and MR image acquisition with sub-400 ps coincidence time resolution. Simultaneous PET/MR holds great potential as a method of interrogating molecular, functional, and anatomical parameters in clinical disease in one study. Despite the complementary imaging capabilities of PET and MRI, their respective hardware tends to be incompatible due to mutual interference. In this work, the GE SIGNA PET/MR is evaluated in terms of PET performance and the potential effects of interference from MRI operation. Methods: The NEMA NU 2-2012 protocol was followed to measure PET performance parameters including spatial resolution, noise equivalent count rate, sensitivity, accuracy, and image quality. Each of these tests was performed both with the MR subsystem idle and with continuous MR pulsing for the duration of the PET data acquisition. Most measurements were repeated at three separate test sites where the system is installed. Results: The scanner has achieved an average of 4.4, 4.1, and 5.3 mm full width at half maximum radial, tangential, and axial spatial resolutions, respectively, at 1 cm from the transaxial FOV center. The peak noise equivalent count rate (NECR) of 218 kcps and a scatter fraction of 43.6% are reached at an activity concentration of 17.8 kBq/ml. Sensitivity at the center position is 23.3 cps/kBq. The maximum relative slice count rate error below peak NECR was 3.3%, and the residual error from attenuation and scatter corrections was 3.6%. Continuous MR pulsing had either no effect or a minor effect on each measurement. Conclusions: Performance measurements of the ToF-PET whole body GE SIGNA PET/MR system indicate that it is a promising new simultaneous imaging platform.

60 APPLIED LIFE SCIENCES↗

Field Testing of Self-Healing Metallic Coatings for Internal Corrosion Protection of Natural Gas Pipelines

Internal corrosion occurs in natural gas pipelines primarily due to the presence of water, carbon dioxide, and hydrogen sulfide. Internal corrosion can eventually result in leakage, cracks, and rupture of the pipeline. The objective of this work is to mitigate internal corrosion in steel pipelines transporting natural gas using cold spray coatings. The corrosion behavior of carbon steel coated with self-healing zinc chromium (ZnCr) and zinc niobium (ZnNb) cold spray coatings was investigated in a natural gas environment. For comparison purposes, hot-dip galvanized steel (HDGS) was tested under the same conditions as cold spray coatings. The field test was performed at the NW Natural gas storage facility in Mist, Oregon. The field test was conducted in a 6-inch diameter pipe transporting wet natural gas out of an underground storage well at 500 psi and 4.4 °C. The coupons were tested for 15 and 32 days under stagnant and flow conditions, respectively. Weight loss method was used to measure the corrosion rate of metallic coatings. Post-corrosion surface characterization was performed on the specimen using a scanning electron microscopy (SEM) equipped with energy dispersive X-ray spectroscopy (EDS). Crystalline phases were determined by X-ray diffraction (XRD). The field-test results confirmed that the metallic coatings provided corrosion protection of carbon steel exposed to wet natural gas under stagnant and flow conditions. The formation of the ZnCO 3 layer on top of ZnNb and ZnCr coatings led to passivation of the coatings which helps to reduce the self-corrosion. These layers form a barrier for diffusion of corrosive species to the surface.

03 NATURAL GAS↗