040226_AnnularFuel_FuelPerformance_LRSv2

This slide deck summarizes a comparative fuel performance assessment of four annular fuel concepts for pressurized water reactor applications against a reference 17×17 fuel design. Overall, annular fuel geometry improves several key thermal-mechanical performance metrics, with the large-annulus configuration providing the most favorable balance of benefits. Relative to the reference design, annular fuel reduces peak fuel temperature by lowering thermal resistance through a thinner fuel pellet and smaller heat-conduction path. At the same time, the reduced fuel volume raises local burnup and correspondingly increases fission gas release. Despite this, rod internal pressure at end of life decreases because the annular geometry provides greater internal void volume. Annular designs also tend to delay fuel-cladding gap closure, although this advantage diminishes in thin-gap configurations where the smaller initial gap accelerates closure. Similarly, hoop stress and hoop strain are generally reduced for annular fuel, but both increase as the initial gap becomes smaller, indicating a potential cladding integrity concern for thin-gap designs. Corrosion performance shows no meaningful variation among the concepts considered. Taken together, the results indicate that annular fuel can offer significant performance advantages in a PWR environment, with large-annulus designs emerging as the strongest candidate while thin-gap geometries introduce more challenging mechanical margins.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Air Source Heat Pumps in Very Cold Climates

Air source heat pumps (ASHPs) in heating mode use a refrigeration cycle to remove heat from the outside air and transfer it into a building. Therefore, ASHPs have the potential to save energy compared to conventional heat sources that create the heat as opposed to transferring it from outside. Many cold climate ASHPs available on the market today can operate at outside temperatures of -25 degrees C (-13 degrees F) or even lower. As a result of technological advances and other factors, there is growing interest in ASHPs in cold climates, including very cold regions such as Alaska. However, guidance on the selection, installation, and operation of ASHPs in these very cold climates is limited, as significant data gaps exist regarding the performance of ASHPs in very cold environments. To address these data gaps and guide future innovations, our research team has studied the field performance of several ASHP installations in Alaska and done lab evaluations of several ASHP models using a cold chamber. While a cold chamber cannot fully reflect field conditions, it allowed for changing one variable at a time and gaining additional understanding of the behavior of ASHPs that would be difficult to gain from field studies only. This study focused on two main variables: the temperature in the chamber (representing the outdoor temperature) and the level of thermal loading of the ASHP. The results from the field as well as the lab show that ASHPs can operate with relatively high efficiency even in very cold climates if used in appropriate situations and in an appropriate way. It was found that not only the outside temperature, but also the level of thermal loading is a significant factor affecting the ASHP efficiency and needs to be carefully considered when sizing and operating ASHPs in very cold climates.

air source heat pump↗

Evaluating the impact of functional groups on membrane‐mediated CO 2 / N 2 gas separations using a common polymer backbone

Abstract Polymeric membranes have shown tremendous promise for the separation of CO 2 from flue gas streams. However, few systematic studies have been conducted to better understand the impact that chemical functionalities have on membrane‐based gas separation performance. To address this gap, we herein describe the synthesis and gas separation performance of a series of vinyl‐addition polynorbornenes bearing various CO 2 ‐philic functional groups. To facilitate direct comparison between functional groups, each material was designed to maintain a common polymer backbone. Though the incorporation of CO 2 ‐philic moieties within a dense polymeric membrane is frequently hypothesized to enhance CO 2 solubility, and thereby increase CO 2 /N 2 selectivity, our results demonstrate that the incorporation of CO 2 ‐philic groups onto a common polymer backbone do not necessarily result in increased gas separation performance. Experimental and computational results demonstrate that the incorporation of amidoxime groups onto a polynorbornene backbone increase CO 2 /N 2 selectivity, whereas commonly employed ethereal side chains only increased permeability.

Higgins, Morgan A.↗

Optical study of the band structure of wurtzite GaP nanowires

We investigated the optical properties of wurtzite (WZ) GaP nanowires by performing photoluminescence (PL) and time-resolved PL measurements in the temperature range from 4 K to 300 K, together with atom probe tomography to identify residual impurities in the nanowires. At low temperature, the WZ GaP luminescence shows donor-acceptor pair emission at 2.115 eV and 2.088 eV, and Burstein-Moss band-filling continuum between 2.180 and 2.253 eV, resulting in a direct band gap above 2.170 eV. Sharp exciton α-β-γ lines are observed at 2.140–2.164–2.252 eV, respectively, showing clear differences in lifetime, presence of phonon replicas, and temperature-dependence. The excitonic nature of those peaks is critically discussed, leading to a direct band gap of ∼2.190 eV and to a resonant state associated with the γ-line ∼80 meV above the Γ{sub 8C} conduction band edge.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of the thermal conductivity of molten LiF-NaF-KF with experiments, theory, and equilibrium molecular dynamics

Molten salts are being proposed for numerous advanced energy applications, including advanced nuclear reactors, concentrating solar power plants, thermal energy storage, and fusion reactors. Accurate knowledge of the thermophysical properties of molten salts directly impact the performance of these energy systems and are essential for design and safety analyses. Thermal conductivity data for fluoride molten salts and mixtures are especially lacking. In this work, experimental measurements of thermal conductivity using the steady-state variable gap technique were performed on eutectic LiF-NaF-KF from 834 to 1195 K. The experiment accounts for radiative, convective, and conductive heat losses. In addition, theoretical and molecular dynamics models are used, from 750 K up to 1300 K, to estimate the thermal conductivity for comparison with the experimental results. The results of experiments show a weak negative deviation of thermal conductivity with temperature, unlike previous experimental results in the literature. The measured thermal conductivity magnitudes agree with the theoretical and molecular dynamics predictions, aside from the data above 1100 K, where heat losses and radiative errors are the most significant, having a 16% maximum deviation from theory. These experimental results provide new thermal conductivity data for the LiF-NaF-KF system and further validation of the predictive models. The theoretical model was used to map the composition and temperature dependent thermal conductivity of LiF-NaF-KF and the mapping’s deviation from a linear additivity estimation of thermal conductivity. Additionally, this mapping showed the highest deviations from linearity for KF-LiF rich mixtures and increasing deviation with temperature. Notably, the deviation from linearity near the LiF-NaF-KF eutectic composition was around 25%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Statistical uncertainty of eddy covariance CO 2 fluxes inferred using a residual bootstrap approach

High-frequency eddy-covariance measurements of net ecosystem CO 2 exchange (NEE) with the atmosphere are valuable resources for model parameterization, calibration, and validation. However, uncertainties in measured data, i.e., data gaps and inherent random errors, create problems for researchers attempting to quantify uncertainties in model projections of terrestrial ecosystem carbon cycling. Here, we demonstrate that a model-data fusion method (residual bootstrap) produces defensible annual NEE sums, through mimicking the behavior of random errors, filling missing values, and simulating gap-filling biases. This study estimated annual NEE sums for 53 site-years based on nine eddy-covariance tower sites in the USA, and found that our annual estimates were, in most cases, comparable in magnitude with those obtained from AmeriFlux gap-filled data. Additionally, compared to the AmeriFlux standardized gap-filling, our approach provides better NEE estimates for moderate to longer, and more frequent, data gaps. Annual accumulated uncertainties in NEE at the 95% confidence level were ±30gCm -2 year -1 for evergreen needleleaf forests; ±60gCm -2 year -1 for deciduous broadleaf forests; and ±80gCm -2 year -1 for croplands. The residual bootstrap performed worst when gap length was greater than one month or data exclusion greater than 90% during the growing season, common to other gap-filling techniques. However, this study produced robust results for most site years when monthly data coverage during the growing season is not extremely low. We therefore suggest that the inclusion of NEE uncertainty estimates and better estimation for moderate to longer, and more frequent, data gaps as provided by the residual bootstrap approach can be beneficial for ecosystem model evaluation.

54 ENVIRONMENTAL SCIENCES↗

Overview of Aeroacoustic Testing of the High-Lift Common Research Model

This paper presents an overview of the experimental data obtained in a 2020/2021 aeroacoustic test of the high-lift variant of the common research model. The breadth of the aerodynamic and acoustic measurements is highlighted along with some key results. Aerodynamic data were observed to be consistent with previous observations, and the acoustic measurements were repeatable once some background noise and shear layer issues were resolved. The primary purpose of the test was to evaluate the noise reduction potential of slat noise reduction devices, and a slat-gap filler was found to produce substantial noise reduction over a broad frequency range. The gap filler was designed to meet practical implementation considerations at full scale and constructed out of shape-memory alloys that would allow the slat to be articulated. However, additional structural testing will be required to demonstrate the performance of the gap filler during slat deployment and retraction. Over 3,500 test points were collected during the test, and only a small fraction of the experimental data has been processed in a preliminary manner. Nonetheless, the results presented demonstrate the quality of the dataset and reveal some insights about slat noise.

Aeroacoustics↗

A guide to performing CO 2 electrolysis in zero-gap electrolyzers

Recent advances in the technology readiness level (TRL) of low-temperature electrochemical CO 2 reduction (eCO2R) have demonstrated that the technology has potential for industrial deployment. However, industrial deployment of eCO2R still requires advances to reach cost parity with existing thermal catalytic pathways. Technoeconomic analysis of eCO2R suggests that research and development will require a decrease in both capital expenditures and operational expenditures to be cost competitive. Here, to decrease the capital expenditures of the system will require increasing the durability to >3 years, while decreasing the operational expenditures will require an increase in energy efficiency due to the cost of electricity being the driving operational cost of a unit.

Energy↗

Disentangling the gap between pure and mixed-gas performance of thin film composite membranes through improved cell design and testing methods

Testing thin film composite (TFC) membrane coupons at low stage-cuts (≤5%) in a sweep-gas permeation system is a common practice to obtain mixed-gas separation properties for benchmarking performance and making scale-up decisions. However, even under these idealized conditions, mixed-gas permeance and selectivity can be more than 30% lower than their pure-gas values, partially due to concentration polarization, an effect that typically intensifies with increased membrane permeance. This study investigates the effect of cell design on mixed-gas testing using PolyActive TM TFC membranes with pure-gas CO 2 permeance of 1700 – 3100 gas permeance unit (GPU), covering the permeance range of most state-of-the-art CO 2 /N 2 separation membranes. Here, we designed and 3D-printed a counter-current permeation cell with enhanced feed and sweep flow efficiency, resulting in a 33 – 41% increase in mixed-gas CO 2 permeance compared to traditional permeation cells. Furthermore, we compared sweep-gas and vacuum permeation methods using traditional permeation cells, revealing that the latter delivers 41% higher mixed-gas CO 2 permeance, because vacuuming effectively minimizes the downstream concentration polarization. These findings highlight the importance of cell design and permeation apparatus selection in lab-scale mixed-gas testing, with strong implications for module design and process optimization at the industrial scale.

mixed gas performance↗

PBX 9502 air-gap tests

A small number of simple air-gap tests were performed on 1-inch diameter PBX 9502 cylinders to determine an approximate threshold for detonation failure. The primary diagnostics were streak imaging and dent measurements in a steel witness plate. Relight was found to occur, with negligible excess transit time, for air gaps up to 1 mm. Relight did not occur with a 3-mm air gap.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Quantitative Performance Assessment of Proxy Apps and Parents (Report for ECP Proxy App Project Milestone ADCD-504-11)

The ECP Proxy Application Project has an annual milestone to assess the state of ECP proxy applications. Our FY21 milestone (ADCD-504-11) proposed to: "Assess the performance and fidelity of proxy applications, including those in the ECP Proxy App Suite, relative to the ECP Application workload on heterogeneous platforms. Use proxy applications and selected ECP applications to assess the utility of critical elements of the Exascale toolchain, especially tools used to collect performance data. Identify gaps in coverage and/or common situations in which proxies may fail to adequately represent ECP applications." To satisfy this milestone, the following specific tasks were completed: Study ability of MACSio to represent I/O workloads of adaptive mesh codes; Prepare report on assessed performance and debugging tools; Perform cosine similarity study on Intel and P9 and submit paper; Complete LDMS/GPU subcontract, complete and receive report; Complete validation of LDMS data collection for GPUs and submit paper; and Perform cosine similarity study on GPUs.

97 MATHEMATICS AND COMPUTING↗

Bridging the Gap Between Pure and Mixed-Gas Performance of Thin-Film Composite Membranes

This study examines the influence of cell design on mixed-gas testing with PolyActive™ TFC membranes, featuring pure-gas CO₂ permeance of 1700–3100 GPU, representative of state-of-the-art CO₂/N₂ separation membranes. By designing and 3D-printing a counter-current permeation cell with optimized flow efficiency, we achieved a 33–41% increase in mixed-gas CO₂ permeance compared to traditional cells. Additionally, a comparison of sweep-gas and vacuum permeation methods revealed that vacuum operation mitigates downstream polarization, enhancing mixed-gas CO₂ permeance by 41%. These results underscore the critical role of permeation cell design and testing methods in accurately evaluating membrane performance, with significant implications for scaling up TFC membranes and optimizing industrial processes.

3D printing↗

Elevating optical activity: Efficient on-edge lithography of three-dimensional starfish metamaterial

We present an approach for extremely fast, wafer-scale fabrication of chiral starfish metamaterials based on electron beam- and on-edge lithography. A millimeter sized array of both the planar chiral and the true 3D chiral starfish is realized, and their chiroptical performances are compared by circular dichroism measurements. We find optical activity in the visible and near-infrared spectral range, where the 3D starfish clearly outperforms the planar design by almost 2 orders of magnitude, though fabrication efforts are only moderately increased. The presented approach is capable of bridging the gap between high performance optical chiral metamaterials and industrial production by nanoimprint technology.

36 MATERIALS SCIENCE↗

Barrier infrared detector

A superlattice-based infrared absorber and the matching electron-blocking and hole-blocking unipolar barriers, absorbers and barriers with graded band gaps, high-performance infrared detectors, and methods of manufacturing such devices are provided herein. The infrared absorber material is made from a superlattice (periodic structure) where each period consists of two or more layers of InAs, InSb, InSbAs, or InGaAs. The layer widths and alloy compositions are chosen to yield the desired energy band gap, absorption strength, and strain balance for the particular application. Furthermore, the periodicity of the superlattice can be "chirped" (varied) to create a material with a graded or varying energy band gap. The superlattice based barrier infrared detectors described and demonstrated herein have spectral ranges covering the entire 3-5 micron atmospheric transmission window, excellent dark current characteristics operating at least 150K, high yield, and have the potential for high-operability, high-uniformity focal plane arrays.

Ting, David Z.↗

PAVE: An In Situ Framework for Scientific Visualization and Machine Learning Coupling

Machine learning (ML) has emerged as a tool for understanding data at scale. However, this new methodology comes at a cost because ML requires the use of even more HPC resources to generate ML algorithms. In addition to the compute resources required to develop ML algorithms, ML does not sidestep one of the biggest challenges on leading-edge HPC systems: the increasing gap between compute performance and I/O bandwidth. This has led to a strong push towards in situ, processing the data as it is generated, strategies to mitigate the I/O bottleneck. Unfortunately, there are no in situ frameworks dedicated to coupling scientific visualization and ML at scale to develop ML algorithms for scientific visualization. To address the ML and in situ visualization gap, we introduce PAVE. PAVE is an in situ framework which addresses the data management needs between visualisation and machine learning tasks. We demonstrate our framework with a case study that accelerates physically-based light rendering, path-tracing, through the use of a conditional Generative Adversarial neural Network (cGAN). PAVE couples the training over path-traced images resulting in a generative model able to produce scene renderings with accurate light transport and global illumination of a quality comparable to offline approaches in a more efficient manner.

Kim, Mark B.↗

Energy-Storing Cryogenic Carbon Capture™ for Utility and Industrial-scale Processes (Final Report)

This project leverages work completed under funding from previous U.S. Department of Energy (DOE) projects and other sources of funding around the Cryogenic Carbon Capture Process™ (CCC). The purpose of this project is to further develop a perturbation of the CCC process that stores energy called the Cryogenic Carbon Capture™ Energy Storing (CCC-ES) process. The successful completion of the tasks in this project has prepared the CCC-ES process for scaling and developed initial plans and a feasibility analysis for an engineering-scale or small-commercial scale system that can store at least 10 MWh of energy. The specific areas of work in this project are: (1) Develop a conceptual, site-specific integrated process flow diagram: Sustainable Energy Solutions (SES) developed a conceptual, site-specific plan including a process flow diagram for integrating CCC-ES at a specific location. The proposed system was based on a typical engineering-scale CCC system designed to capture 30-50 metric tonnes of CO 2 per day (TPD), with modifications and additional changes and equipment put in place to add the energy storage element to the system. The 30-50 TPD scale corresponds to the required 10 MWh of stored energy. This task includes updating simulation software for transient analysis. SES also coordinated with the Jim Bridger Power Plant in Point of Rocks, Wyoming to get site-specific data. Using these data, SES completed site-specific preliminary process flow diagrams, estimated capital and operating costs for the CCC-ES system, and used the upgraded software package to estimate the primary figures of merit. (2) Complete a technoeconomic analysis (TEA): SES completed a full-scale TEA of the CCC-ES system to meet specific success criteria. This TEA used process information from the host site selected above. (3) Technology and data gap assessment for the CCC-ES process: As part of the technology gap assessment, SES performed an assessment of the best alternative energy storage solutions including figures of merit and operational strengths and weaknesses. SES then compared the proposed system with a discussion of how it addresses the weaknesses of alternative systems, showing for example a cost of stored energy at less than $50/MWh and with a roundtrip efficiency of greater than 95%. This assessment includes technical and other risk analyses and technology gaps with research and development needs to commercialize the process by 2030. Finally, work includes a commercialization roadmap/development pathway outlining the major milestones to move to a commercially operating CCC-ES system. (4) Phase II pre-FEED project plan: SES completed a project plan for the Phase II pre-FEED analysis using the same host site as in the Phase I conceptual study.

03 NATURAL GAS↗