Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV system performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

A Performance Model for Photovoltaic Modules with Integrated Microinverters

Photovoltaic (PV) systems using microinverters are becoming increasingly popular in the residential system market, as such systems offer several advantages over PV systems using central inverters. PV modules with integrated microinverters, termed AC modules, are emerging to fill this market space. Existing test procedures and performance models designed for separate DC and AC components are unusable for AC modules because these do not allow ready access to the intermediate DC bus. Sandia National Laboratories' Photovoltaics and Distributed Systems department has developed a set of procedures to test, characterize, and model PV modules with integrated microinverters. The resulting empirical model is able to predict the output AC power of with RMS error of 1-2%. This document describes these procedures and provides the results of model validation efforts.

14 SOLAR ENERGY↗

Agrivoltaic Racking Design Optimization Based on Wind and Snow Loading Finite Element Analysis

The racking structure of photovoltaic (PV) systems plays a critical role in ensuring the PV panels generate power properly as it provides integral structural support and sometimes even solar tracking ability. Distinct applications of PV systems require variations of racking structure designs, which yield different mechanical performances under external loading conditions from the environment, such as heavy wind and snow. Past works, such as Reddy et al. [1], have analyzed the pressure effects of wind and snow loading on the racking structure of conventional rooftop and utility PV systems, but there is little knowledge of how various agrivoltaic racking systems perform, in terms of stress and strain, under the same loading conditions. There is also a knowledge gap in the industry on a set of optimized agrivoltaic racking design standards. This study investigates the mechanical performance of various existing racking systems and proposes novel designs that are optimized for agrivoltaics applications under wind and snow loading.

Liao, Quanhuan↗

Albedo Data for Bifacial PV Systems Update

For use by the PV and financial communities to better estimate the performance and to reduce the risk of bifacial PV systems, data sets of ground albedo and associated meteorological data were developed by using existing measurement network data and data contributed by the PV industry. The data sets include time-series data as well as summary information of tabular monthly and yearly data and plots of monthly and hourly albedo values. Complete information is presented in a user’s guide and data are available for download from NREL’s DuraMAT website.

albedo↗

Albedo Data Sets for Bifacial PV Systems: Preprint

For use by the PV and financial communities to better estimate the performance and to reduce the risk of bifacial PV systems, data sets of ground albedo and associated meteorological data were developed by using existing measurement network data and data contributed by the PV industry. The data sets include time-series data as well as summary information of tabular monthly and yearly data and plots of monthly and hourly albedo values. Complete information is presented in a user’s guide and data are available for download from NREL’s DuraMAT website.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Optimal PV Inverter Control in Distribution Systems via Data-Driven Distributionally Robust Optimization

Distribution systems with high penetration of uncertain solar generation call for advanced control strategies of photovoltaics (PVs) inverters. This paper proposes a data-driven distributionally robust optimization (DDDRO) approach to optimally controlling the PV inverters to improve the system operation performance under solar power uncertainties. In the proposed DDDRO approach, a Wasserstein ball-based method is proposed to construct the distributional ambiguity set to model the uncertainties of PV generation through partial observations of historical data without knowing exact probability distributions. We further reformulate the computationally intractable DDDRO model to a mixed integer second order cone programming (MISOCP) problem. The effectiveness and out-of-sample performance of the proposed approach have been demonstrated on a modified IEEE 33-node system. We conduct a comparative study to compare the proposed method with traditional chance constrained programming (CCP). It shows that the proposed DDDRO approach can provide a less conservative yet robust solution to minimize the worse-case expectation of the total network loss while maintaining nodal voltages in a secure range.

Xue, Yaosuo↗

Representing DC-Coupled PV+Battery Hybrids in a Capacity Expansion Model

Recent technology cost and performance improvements and the federal investment tax credit (ITC) have driven growing interest in coupling solar photovoltaic (PV) and battery systems. Combining these technologies into co-located or hybridized PV+battery systems has the potential to lower costs and increase energy output relative to multiple independent systems. In this work, we provide an overview of PV+battery systems and demonstrate methods for incorporating them into NREL’s Regional Energy Deployment System (ReEDS) capacity expansion model. Although the methods are applied to a specific model, we anticipate that the approaches used here can be useful for informing PV+battery method development for other capacity expansion models. The implemented method relies heavily on the native representations of PV and battery technologies; therefore, the focus of this work is on capturing and parameterizing the interactions between them for a configuration in which the PV and battery technologies share a single bi-directional inverter. This work also demonstrates the impacts of including PV+battery systems in the ReEDS optimization for the conterminous United States through 2050. In particular, we perform parametric sensitivities for input assumptions that are uncertain and expected to influence PV+battery deployment levels, including (a) the cost of PV+battery systems relative to independent PV and battery systems, (b) the battery component’s qualification for the ITC, and (c) future cost trajectories for PV and battery systems. We find that PV+battery deployment could occur throughout the conterminous United States if there are cost savings associated with DC coupling PV and battery technologies. If even modest (5%) cost savings can be achieved (through a shared inverter and balance-of-system costs), then approximately one-third of utility-scale PV deployment through 2050 adopts the DC-coupled hybrid configuration, resulting in total PV+battery deployment that exceeds the magnitude of PV+battery projects in U.S. interconnection queues in 2020. If greater cost savings can be achieved through DC coupling (e.g., due to a growing amount of shared balance-of-system costs, reduced financial risk, or modularity) or more rapid cost and performance improvements are realized for PV and battery technologies, then total PV+battery deployment and the share of PV and battery deployment that adopts the hybrid configuration grows (to >50%). In all cases, growing PV+battery deployment primarily displaces independent PV and battery technologies, indicating the strong competition between the hybrid and independent configurations comprising technologies with similar performance characteristics.

14 SOLAR ENERGY↗

Photovoltaic Data Acquisition (PVDAQ) Public Datasets

The NREL PVDAQ is a large-scale time-series database containing system metadata and performance data from a variety of experimental PV sites and commercial public PV sites. The datasets are used to perform on-going performance and degradation analysis. Some of the sets can exhibit common elements that effect PV performance (e.g. soiling). The dataset consists of a series of files devoted to each of the systems and an associated set of metadata information that explains details about the system hardware and the site geo-location. Some system datasets also include environmental sensors that cover irradiance, temperatures, wind speeds, and precipitation at the site.

Array↗

Scientific frontiers of agrivoltaic cropping systems

Agrivoltaic (AV) systems integrate agriculture with electricity conversion through photovoltaic (PV) modules. Compared with conventional ground-mounted PV systems, AV systems can reduce land-use competition and offer agronomic and economic advantages, such as more stable crop production and additional farm income. However, AV systems can decrease agricultural performance and are typically 20-90% costlier to install than conventional PV systems. Here, in this Review, we analyse the implementation of AV cropping systems to preserve agricultural activities and highlight challenges and barriers. The global electricity potential of AV systems is ~66-385 PWh annually, depending on PV technology and installation density, if deployed in the most suitable areas, without accounting for grid availability. Scaling up has been hindered by crop selection for shading conditions, decreased energy conversion per unit of land area and issues with social acceptance, landscape impact and environmental sustainability. These issues can be addressed by developments such as wavelength-selective PV; system configurations, such as optimizing module spacing to reduce shading; and operational methods, such as optimizing tracking strategies and integrating agricultural infrastructure. Cross-sector policies can support AV systems by addressing the needs of diverse stakeholders over shared land resources. Further development will require collaboration among the design, performance, deployment and systems research communities.

14 SOLAR ENERGY↗

Design of Thermophotovoltaic Cells for Optimal System Efficiency, Accounting for Photon Reuse from Front and Back Contacts

We develop a model showing how reflection from both the front and back contacts of thermophotovoltaic (TPV) cells affects the system efficiency. From this foundation we determine the design rules for front grids for TPV cells, and assess the consequences of those rules on cell design and system performance. We show that these design rules are different and more complex than the corresponding design rules for solar photovoltaic (PV) cells, and can lead to substantially different grid design and system performance than if the simpler solar PV design rules were used.

14 SOLAR ENERGY↗

System performance predictions for Space Station Freedom's electric power system

Space Station Freedom Electric Power System (EPS) capability to effectively deliver power to housekeeping and user loads continues to strongly influence Freedom's design and planned approaches for assembly and operations. The EPS design consists of silicon photovoltaic (PV) arrays, nickel-hydrogen batteries, and direct current power management and distribution hardware and cabling. To properly characterize the inherent EPS design capability, detailed system performance analyses must be performed for early stages as well as for the fully assembled station up to 15 years after beginning of life. Such analyses were repeatedly performed using the FORTRAN code SPACE (Station Power Analysis for Capability Evaluation) developed at the NASA Lewis Research Center over a 10-year period. SPACE combines orbital mechanics routines, station orientation/pointing routines, PV array and battery performance models, and a distribution system load-flow analysis to predict EPS performance. Time-dependent, performance degradation, low earth orbit environmental interactions, and EPS architecture build-up are incorporated in SPACE. Results from two typical SPACE analytical cases are presented: (1) an electric load driven case and (2) a maximum EPS capability case.

Kerslake, Thomas W.↗

Techno-economic implications and cost of forecasting errors in solar PV power production using optimized deep learning models

Accurate solar Photovoltaic (PV) power forecasting is important for enhancing both the performance and economic feasibility of PV systems. This study evaluates several deep learning models, including Dense Neural Networks (DNN), Long Short-Term Memory (LSTM), Convolutional Neural Networks (CNN), and a hybrid LSTMCNN model, for predicting PV power production one day in advance. Prior to optimization, the models exhibited relatively high errors, with the best model (DNN) achieving a Root Mean Square Error (RMSE) of 31.13 kW and a coefficient of determination (R 2 ) of 62.15 %. After employing Bayesian optimization, the LSTM-CNN model demonstrated the best performance, with the RMSE reduced to 9.79 kW and R 2 improved to 97.62 %, showcasing significant enhancement in predictive accuracy. Here, the economic evaluation considered three cases: rewards for underestimation (0.08 USD/kWh), no rewards, and penalties for both over-and underestimation (120 % of the utility tariff). In the rewards scenario, the LSTM-CNN model reduced the Levelized Cost of Electricity (LCOE) by 4 %, while in the penalty scenario, a backup diesel generator would have increased the LCOE by 49 %. Additionally, the LSTM-CNN model minimized financial losses, achieving the lowest penalties and maximizing net cash flow compared to other models, demonstrating its overall technical and economic superiority.

Deep learning↗

A high efficiency photovoltaic module integrated converter with the asymmetrical half-bridge flyback converter

A module integrated converter (MIC) for a photovoltaic (PV) cell is important part of power conditioning system (PCS). It performs maximum power point tracking of a PV cell to generate the power as much as possible from solar energy. There are several methods for connection between the PV modules and the MICs. In order to avoid partial shading effects, converter-per-module approach was proposed. The MIC that performs maximum power point tracking (MPPT), if it is low efficiency, is no use. The MIC whose output is connected to the output of PV module was proposed for high efficiency. However, there are some problems. In this study, an asymmetrical half-bridge flyback converter is proposed instead of the original flyback converter with same method to solve the problems. The proposed MIC was built to verify the performance. The new topology using soft switching technique showed good performance for the efficiency. At the higher power, the efficiency of the proposed converter is higher than existing converter. (author)

14 SOLAR ENERGY↗

Energy and economic assessment of desiccant cooling systems coupled with single glazed air and hybrid PV/thermal solar collectors for applications in hot and humid climate

This paper presents a detailed analysis of the energy and economic performance of desiccant cooling systems (DEC) equipped with both single glazed standard air and hybrid photovoltaic/thermal (PV/t) collectors for applications in hot and humid climates. The use of 'solar cogeneration' by means of PV/t hybrid collectors enables the simultaneous production of electricity and heat, which can be directly used by desiccant air handling units, thereby making it possible to achieve very energy savings. The present work shows the results of detailed simulations conducted for a set of desiccant cooling systems operating without any heat storage. System performance was investigated through hourly simulations for different systems and load combinations. Three configurations of DEC systems were considered: standard DEC, DEC with an integrated heat pump and DEC with an enthalpy wheel. Two kinds of building occupations were considered: office and lecture room. Moreover, three configurations of solar-assisted air handling units (AHU) equipped with desiccant wheels were considered and compared with standard AHUs, focusing on achievable primary energy savings. The relationship between the solar collector's area and the specific primary energy consumption for different system configurations and building occupation patterns is described. For both occupation patterns, sensitivity analysis on system performance was performed for different solar collector areas. Also, this work presents an economic assessment of the systems. The cost of conserved energy and the payback time were calculated, with and without public incentives for solar cooling systems. It is worth noting that the use of photovoltaics, and thus the exploitation of related available incentives in many European countries, could positively influence the spread of solar air cooling technologies (SAC). An outcome of this work is that SAC systems equipped with PV/t collectors are shown to have better performance in terms of primary energy saving than conventional systems fed by vapour compression chillers and coupled with PV cells. All SAC systems present good figures for primary energy consumption. The best performances are seen in systems with integrated heat pumps and small solar collector areas. The economics of these SAC systems at current equipment costs and energy prices are acceptable. They become more interesting in the case of public incentives of up to 30% of the investment cost (Simple Payback Time from 5 to 10 years) and doubled energy prices. (author)

14 SOLAR ENERGY↗

Performance evaluation of photovoltaic/thermal–HDH desalination system

The efficiency of photovoltaic (PV) panel drops with increase in cell temperature. The temperature of the PV panel can be controlled with various cooling techniques. In the proposed work the PV panel is cooled by circulating water and the recovered heat energy is used to run a humidification and dehumidification desalination to produce distilled water from sea water (or) brackish water. This work deals with a detailed analysis of performance of combined power and desalination (Photovoltaic/Thermal–Humidification and Dehumidification) system. A mathematical model of PV/thermal–humidification dehumidification plant was developed and simulations were carried out in MATLAB environment. The performance of photovoltaic/ thermal desalination (Photovoltaic/Thermal–Humidification and Dehumidification) system was investigated under various solar radiation levels (800–1000 W/m{sup 2}). For each solar radiation level the effect of mass flow rate of coolant water (30–110 kg/h) on water outlet temperature, PV efficiency, PVT thermal efficiency, distilled water production, and plant efficiency was studied. Results show that under each solar radiation level increasing coolant flow rate increases efficiency of PV panel and reduces the plant efficiency. The highest PV efficiency (16.598%) was reached under 800 W/m{sup 2} at mass flow rate of 110 kg/h and the highest plant efficiency (43.15%) was reached under 800 W/m{sup 2} at a mass flow rate of 30 kg/h. The maximum amount of distilled water production rate (0.82 L/h) was reached under 1000 W/m{sup 2} at water mass flow rate of 30 kg/h.

14 SOLAR ENERGY↗

Power conditioning subsystems for photovoltaic central-station power plants - Technology and performance

Central-Station (CS) Photovoltaic (PV) systems have the potential of economically displacing significant amounts of centrally generated electricity. However, the technical viability and, to some extent, the economic viability of central-station PV generation technology will depend upon the availability of large power conditioners that are efficient, safe, reliable, and economical. This paper is an overview of the technical and cost requirements that must be met to develop economically viable power conditioning subsystems (PCS) for central-station power plants. The paper also examines various already commercially available PCS hardware that may be suitable for use in today's central PV power stations.

Krauthamer, S.↗

ESPC ESA Case Study: Energy Affordability at the National Institute of Standards and Technology

The U.S. Department of Commerce (DOC) National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland, installed a 5 MW-DC photovoltaic (PV) system under an energy savings performance contract energy sales agreement (ESPC ESA). The project was implemented using the U.S. Department of Energy (DOE) ESPC ENABLE contract vehicle. This project provides an example of the benefits of using an ESPC ESA to reduce project costs and provide the best value to the government, allowing the system owner to monetize tax incentives such as the federal investment tax credit (ITC) and Modified Accelerated Cost Recovery System (MACRS), and use or sell the solar renewable energy certificates (SRECs).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

System Advisor Model: Flat Plate Photovoltaic Performance Modeling Validation Report

The System Advisor Model (SAM) is a free software tool that performs detailed analysis of both system performance and system financing for a variety of renewable energy technologies. This report provides detailed validation of the SAM flat plate photovoltaic performance model by comparing SAM-modeled PV system generation data to actual measured production data for nine PV systems ranging from 75 kW to greater than 25 MW in size. The results show strong agreement between SAM predictions and field data, with annualized prediction error below 3% for all fixed tilt cases and below 8% for all one axis tracked cases. The analysis concludes that snow cover and system outages are the primary sources of disagreement, and other deviations resulting from seasonal biases in the irradiation models and one axis tracking issues are discussed in detail.

14 SOLAR ENERGY↗