Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV grid integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Multi-Timescale Integrated Dynamics and Scheduling for Solar (MIDAS-Solar) (Final Technical Report)

Solar photovoltaic (PV) installations have experienced unprecedented growth in the United States. PV will become not only an energy producer but also a necessary provider of ancillary services at multiple timescales. Conventional methods to simulate power systems operations - such as long-term production simulation (which typically considers schedules from hours to minutes by using an optimization framework) and short-term transient studies (which simulate dynamics from seconds to sub-seconds using state variables and differential equations) - are not sufficient for studying the multiple-timescale variation of solar generation and its impact on system reliability. Long-term system economics and short-term system dynamics are highly coupled, particularly when the penetration level of renewable generation is extremely high, because the uncertainty and variability of solar generation will impact both power system steady-state and dynamic performance. This project helps meet and exceed the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office goal of systems integration by directly addressing this stability and reliability challenge for power grid planning and operation. We have developed a temporally comprehensive, closed-loop simulation model, named Multi-timescale Integrated Dynamics and Scheduling (MIDAS), that seamlessly simulates power system operations from economic scheduling (day-ahead to hours) to dynamic response analysis (seconds to sub-seconds). For schedules with very high levels of inverter-based resources (IBRs), up to and including 100%, the stability of grid controls has been evaluated through electromagnetic transient (EMT) simulations and power-hardware-in-the-loop (PHIL) simulations of key transient events at key schedule points. Specifically, MIDAS provides: 1) a closed-loop simulation framework for simulating timescales from economic scheduling to dynamic stability analysis; 2) machine learning-based stability assessment; 3) EMT modeling and analysis for large-scale power systems; 4) MIDAS PHIL test bed. We worked with Hawaii Electric Companies to apply the MIDAS study framework to a Maui grid study. The entire island's transmission system was modeled in detail - from a yearly scheduling model, to a second-level frequency dynamic model, down to a sub-second-scale EMT model to address critical stability issues. The project demonstrated how MIDAS can help system planners and operators assess system reliability and stability while the power grid is marching toward a high-renewable, high-IBR future. In this Maui grid study, we found that 100% instantaneous IBR operation is achievable in EMT simulation and PHIL testing, and grid planners and operators might need new analysis/simulation tools to assess grid reliability and stability in the scheduling stage. MIDAS will bring Maui and other systems closer to 100% clean and stable energy futures. (In this study, we examined transient stability. Other topics necessary for 100% IBR operation, such as protection and resource adequacy, were not examined.)

100% Renewables↗

Analysis of 0.1-Hz Var Oscillations in Solar Photovoltaic Power Plants

Oscillations with very low frequency at 0.1 Hz, have been observed in voltage and var in practical solar photovoltaic (PV) systems when power exporting ramps up to a certain level. Here, this letter provides an explanation on the formation of 0.1-Hz oscillations and identifies three critical factors that lead to the oscillations: communication delay between the plant-level control and the inverter-level control, high volt/var sensitivity at a high power exporting level, and the volt-var feedback system consisting of the plant control, inverter control and the grid impact. Furthermore, a critical feature of the 0.1-Hz oscillation is also explained: why oscillations appear only in voltage and var, but not in real power.

14 SOLAR ENERGY↗

Assessing geothermal/solar hybridization – Integrating a solar thermal topping cycle into a geothermal bottoming cycle with energy storage

Geothermal and concentrating solar power (CSP) technologies typically use heat at different temperatures in their commercial deployments. This enables a technically viable hybridization of a solar topping cycle and a geothermal bottoming cycle at locations where both resources are available. In this article, an underperforming geothermal power system based at Burley, Idaho is used as a baseline to investigate the technical and economic potential of such a hybrid cycle. A direct thermal energy storage (TES) system is also integrated to overcome the intermittency of the solar resource. Design and off-design behavior of key components are modelled to simulate the annual performance of the hybrid system on an hourly basis. The sizing of the solar field and thermal storage is investigated and is seen to significantly impact the annual electricity generation and efficiency. Various cost scenarios for the solar field and thermal energy storage are investigated. An economic metric - levelized cost of electricity (LCOE) - is used to optimize the solar field sizing and TES capacity. The hybrid plant converts the additional solar heat input into additional work with an efficiency of 32.9%. Retrofitting a geothermal plant with solar and eight hours of energy storage can achieve an LCOE of 0.136 $/kWhe in current cost scenarios and 0.081 $/kWhe in a future cost reduction scenario. Although the hybrid system cannot directly compete with current PV systems without batteries, it has an LCOE 32% lower than that of a PV-battery system. This paper provides insights into the research and development of the future grid with a high renewable energy penetration and encourages further study of energy hybridization for improved efficiencies and economics.

15 GEOTHERMAL ENERGY↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices: Preprint

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Sustainable Campus with PEV and Microgrid

Market penetration of electric vehicles (EVs) is gaining momentum, as is the move towards increasingly distributed, clean and renewable electricity sources. EV charging shifts a significant portion of transportation energy use onto building electricity meters. Hence, integration strategies for energy-efficiency in buildings and transport sectors are of increasing importance. This paper focuses on a portion of that integration: the analysis of an optimal interaction of EVs with a building-serving transformer, and coupling it to a microgrid that includes PV, a fuel cell and a natural gas micro-turbine. The test-case is the Nanyang Technological University (NTU), Singapore campus. The system under study is the Laboratory of Clean Energy Research (LaCER) Lab that houses the award winning Microgrid Energy Management System (MG-EMS) project. The paper analyses three different case scenarios to estimate the number of EVs that can be supported by the building transformer serving LaCER. An approximation of the actual load data collected for the building into different time intervals is performed for a transformer loss of life (LOL) calculation. The additional EV loads that can be supported by the transformer with and without the microgrid are analyzed. The numbers of possible EVs that can be charged at any given time under the three scenarios are also determined. The possibility of using EV fleet at NTU campus to achieve demand response capability and intermittent PV output leveling through vehicle to grid (V2G) technology and building energy management systems is also explored.

Singh, Reshma↗

Investigating capacity credit sensitivity to reliability metrics and computational methodologies

Assigning capacity value to renewable energy sources (RES) is a challenge faced in planning their integration with the grid. The difficulties stem from the natural characteristics of variability and intermittency of wind and solar sources. The capacity credit (CC) analysis evaluates the system’s actual power output compared with a constant capacity generator, i.e., conventional generator and determines an effective capacity to use for planning and operation. Herein this paper presents different factors that could affect the CC of a system. Two methods are proposed to determine the CC, namely equivalent firm capacity (EFC) and effective load carrying capability (ELCC). Since these methods are based on satisfying reliability criteria, daily loss of load expectation (LOLE), hourly loss of load (LOLH), and expected energy not served (EENS) have been employed as indices. To obtain the CC value, both methods apply two techniques: traditional and optimization. Genetic algorithm (GA) is the optimization approach used in this paper. Then, this work compares the two techniques and shows the superior performance of the optimization approach. Two hybrid systems, stand-alone (SA) and grid-connected (GC) modes, are proposed and used as case studies. The hybrid systems consist of photovoltaic (PV), wind turbine (WT), and battery energy storage system (BESS). In this work, three different scenarios are used to compare capacity credit: system as a whole, only wind, and no batteries. Finally, sensitivity analysis is carried out to examine the impact of varying the wind speed, solar irradiation, and load. It is demonstrated that the choice of reliability index plays an important role in determining the capacity credit and it is shown that EENS is a more comprehensive and consistent index of reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration of DER Adoption Forecasting into Distribution Planning: Cooperative Research and Development Final Report, CRADA Number CRD-11-00430 (Project H)

The objective of this project is to improve distributed energy resources (DER) technology, time, and locational impact analysis by incorporating customer adoption intentions and preferences into distribution planning and operations. The National Renewable Energy Laboratory (NREL) shall collaborate with EPRI staff to contribute to the development of methodology, literature review, analysis, and write-up for two sections of a report "Identification and Overview of Methods for Mapping DER Adoption Forecasts” and “Comparative Analysis of Methods for Mapping DER Adoption Forecasts."

14 SOLAR ENERGY↗

Opportunities for Clean Energy in Natural Gas Well Operations: Preprint

The oil and gas industry is increasingly seeking operational improvements to reduce both costs and emissions. Currently, oil and gas directly and indirectly contributes forty-two percent of global greenhouse gas emissions, with over twenty percent of the industry’s emissions coming from operations. Given the opportunity for emissions reductions, this study describes techno-economic analysis evaluating opportunities for distributed energy generation and storage technologies – including solar photovoltaics (PV), distributed wind energy, and battery energy storage – to support companies’ energy cost savings targets, clean energy goals, and energy resiliency needs at hypothetical upstream well sites in the Marcellus Shale in Pennsylvania, both grid-connected and off-grid. These technologies reduce the site’s consumption of grid electricity and natural gas and thus help reduce Scope 1 and 2 emissions associated with electricity and natural gas. For each scenario, a cost of avoided emissions was calculated; these values can be compared to internal organizational value placed on emissions reductions, compared to other emissions reduction strategies such as energy efficiency, reducing flaring, and direct carbon capture and sequestration, and compared to existing (albeit limited) U.S. carbon markets such as California’s Low Carbon Fuel Standard. The study also explores the ability of these electric clean energy technologies to support site resiliency against utility outages.

42 ENGINEERING↗

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Opportunities for Clean Energy in Natural Gas Well Operations

The oil and gas industry is increasingly seeking operational improvements to reduce both costs and emissions while improving resilience against electric grid outages. This study describes techno-economic analysis of opportunities for distributed energy generation and storage technologies to support companies’ energy cost savings, clean energy, and energy resiliency goals. Specifically, the analysis evaluates solar photovoltaics (PV), distributed wind energy, and battery energy storage at hypothetical upstream well sites in the Marcellus Shale in Pennsylvania, both grid-connected and off-grid. Results indicate opportunity for solar PV to reduce operational costs. Additionally, these technologies reduce the site’s consumption of grid electricity and natural gas and thus can help reduce Scope 1 and 2 emissions associated with electricity and natural gas consumption. For each emissions reduction scenario, a cost of avoided emissions was calculated; these values can be compared to internal organizational value placed on emissions reductions, compared to other emissions reduction strategies such as energy efficiency, reducing flaring, and direct carbon capture and sequestration, and compared to existing (albeit limited) U.S. carbon markets such as California’s Low Carbon Fuel Standard. Results indicate that the associated costs of emissions reductions via distributed renewables are competitive with these options and markets. The study also explores the ability of these electric clean energy technologies to support site resiliency against utility outages.

42 ENGINEERING↗

Opportunities for Clean Energy in Natural Gas Well Operations

The oil and gas industry is increasingly seeking operational improvements to reduce both costs and emissions while improving resilience against electric grid outages. This study describes techno-economic analysis of opportunities for distributed energy generation and storage technologies to support companies' energy cost savings, clean energy, and energy resiliency goals. Specifically, the analysis evaluates solar photovoltaics (PV), distributed wind energy, and battery energy storage at hypothetical upstream well sites in the Marcellus Shale in Pennsylvania, both grid-connected and off-grid. Results indicate opportunity for solar PV to reduce operational costs. Additionally, these technologies reduce the site's consumption of grid electricity and natural gas and thus can help reduce Scope 1 and 2 emissions associated with electricity and natural gas consumption. For each emissions reduction scenario, a cost of avoided emissions was calculated; these values can be compared to internal organizational value placed on emissions reductions, compared to other emissions reduction strategies such as energy efficiency, reducing flaring, and direct carbon capture and sequestration, and compared to existing (albeit limited) U.S. carbon markets such as California's Low Carbon Fuel Standard. Results indicate that the associated costs of emissions reductions via distributed renewables are competitive with these options and markets. The study also explores the ability of these electric clean energy technologies to support site resiliency against utility outages.

42 ENGINEERING↗

GaAsP/Si Tandem Solar Cells: Pathway to Low-Cost, High-Efficiency Photovoltaics

Si is the dominant PV technology, now and for the foreseeable future, due to its extensive manufacturing infrastructure, supply chain, feedstock availability, and highly optimized degree of fabrication processes, which altogether has produced an economic scenario where PV electricity generation is often cheaper than conventional fossil based generation. In many places, the overarching goal of grid parity has been achieved, but further improvement in performance-cost metrics are still needed to sustain the continued LCOE reductions needed to not only compete with conventional generation, but displace it on a global scale; a matter of critical importance if we stand any hope of slowing climate change. Nevertheless, single-junction Si PV is already nearing its physical limit, both in performance and cost, and is thus cannot meet these long-term goals alone. To this end, we are working on the development of monolithic III-V/Si tandem solar cells, which improve upon the performance of pure Si by providing enhanced utilization (reduced thermalization) of high-energy photons. This architecture nominally combines the substantial existing knowledge base, manufacturing infrastructure, and low cost of Si PV with the high efficiencies afforded by the well-established multijunction approach — the only proven way to break the single-junction limit. Although the metal-halide perovskite/Si tandem architecture has garnered substantial attention in recent years, serious questions regarding reliability and service lifetime remain, whereas III-V PV has a proven track record, including in the harsh concentrator and space environments. Additionally, there are multiple fabrication approaches to producing III-V/Si tandem cells, but we are focused on monolithic epitaxial integration as it is the most likely to yield the lowest ultimate LCOE in a fully mature, scaled technology. In this work we have produced multiple generations of GaAsP/Si tandem solar cells, demonstrating a more than 10% absolute AM1.5G efficiency improvement within the time frame of the project, including two verified world records. We have done this using industry-standard fabrication methods, showing that this platform can ultimately be manufactured at scale using existing or only slightly upgraded Si and III-V tooling. Our scientific and engineering advances across a range of fundamental and applied areas – III-V/Si heteroepitaxial integration, defect control in metamorphic III-V epitaxy, fundamental materials-oriented solar cell design and modeling methodology, and more – have created clear pathways for continued advances toward the goal of >30% AM1.5G cell efficiency (and >25% module) and will serve to inform the broader research community for well beyond this immediate application. Techno-economic modeling indicates that our approach can indeed meet SunShot/SETO LCOE targets, but as with any “post-Si” technology there are difficult, but not insurmountable barriers, requiring continued focused research and development efforts.

14 SOLAR ENERGY↗

Integration of a DER Management System in Riverside. Final report

The tasks in this project covered various aspects, including algorithm development, algorithm integration into a commercial Active Network Management (ANM) platform, hardware-in-the-loop (HIL) testing in an industry-standard testing platform, pilot demonstration in Riverside, California, and also cost and benefit analysis. The DERMS platform in this project can host different algorithms developed on different platforms (e.g., MATLAB and Python) and it can interact with different hardware devices (e.g., different PV inverters, battery inverters, and different sensors). The DER control solution are based on an advanced model-free, layered, and clustered DER control paradigm. At the core of the DER control algorithms was the concept of Extremum Seeking (ES), which is a model-free probing-based control technique. The ES-based control algorithms were tested on major real-world inverters; both individually and in a cluster. It was shown that even legacy equipment (or when paired with a few additional advanced equipment) can support such advanced control. The monitoring algorithms utilize a heterogeneous set of legacy and advanced sensor measurements, such as behind-the-meter DER sensors, distribution-level Phase Measurement Units, distribution-substation Supervisory Control and Data Acquisition (SCADA), and line current sensors, with their limited availability; in order to infer practical network conditions. Sensor data are utilized to achieve resource forecasting, phase identification, and distribution system state estimation. The technology that was developed and demonstrated in this project could be transformational to utilities, including the smaller municipal utilities such as in Riverside, which may not have the resources to deploy advanced distribution system and DERMS solutions in order to support high penetration of solar power integration. This project created a real-world prototype to provide utilities with an assessment of smart grid monitoring and control technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Introducing the 9500 Node Distribution Test System to Support Advanced Power Applications: An Operations-Focused Approach

The 9500 Node Test System is a representative section of distribution power system model developed as a part of the GridAPPS-D™ project, an effort funded by DOE as a part of the Grid Modernization Lab Consortium (GMLC) program. The test system was developed to fulfill a growing need to represent the rapidly evolving state of electric distribution systems by combining elements of legacy infrastructure systems, modern feeder topologies, and an anticipated future with smart grid technologies. It also provides a network model capable of supporting the simulation of operational scenarios such as the ones in a utility distribution control center. This test system allows the evaluation of the performance of advanced power applications in real-time, such as one that simulates the operations of an Advanced Distribution Management Systems (ADMS), Distributed Energy Resource Management Systems (DERMS), etc. in a Distribution control center. This model is an extension of the widely used IEEE 8500 Node Test Feeder and is currently being validated to become an IEEE test case to help increase adoption and widespread usage among both academia and industry. It is a full-size model representative of a section of a utility’s distribution system with multiple feeders fed from different substations. The model includes multiple distribution circuits, a sub-transmission system, multiple substations, behind the meter customer rooftop photovoltaics (PV), and multiple utility-scale distributed energy resources. To enable accurate simulations of operational scenarios, the 9500 Node Test System is designed to support procedure-based operations, with the ability to realistically demonstrate switching operations, feeder reconfiguration, adjustment of volt-var control equipment, dispatch of distributed generation, and response to planned and unplanned outages. The 9500 Node Test System includes three radial distribution feeders with 12.3 MVA of average load, consisting of both medium voltage and low voltage equipment each supplied by a different distribution substation. The three distribution feeders are connected to each other through Normally-Open switches which can be closed when needed to simulate restoration scenarios due to a fault. One feeder represents today’s grid with low penetration of customer-side renewables. The second represents a potential future grid with microgrids and 100% renewable penetration. The third has no customer generation resources, a district steam plant, and a utility-scale solar farm. The three diverse circuits were created to allow the simulation of both today’s situation as well as potential future scenarios. All three feeders have customers connected by low-voltage secondary triplex lines. This test system meets all requirements outlined in the report for creating a simulation environment that would enable discussion between key technical stakeholders as well as having the potential to accelerate operational application development and their subsequent testing and integration. The new model is a possible representation of what we believe the distribution grid may look like in the future: a high penetration of renewables, reconfigurable radial and mesh topology, numerous DERs, islanded microgrids, and significantly increased data and measurement density. The system supports both the solution of existing and newer algorithms but also enables the evaluation of applications in a realistic operational environment defined by task oriented procedural steps that represent the interaction between the control center operator and field personnel.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Combined Cycle Integrated Thermal Energy Storage “CiTES” (Final Scientific/Technical Report)

The Phase I of this project confirmed the technical feasibility of a Combined Cycle integrated Thermal Energy Storage “CiTES” system, calculated the key performance parameters like power efficiency and costs, and proved its commercial value with full-year simulations for several US electricity markets with high degree of variable renewable generation and volatile hourly electricity prices. The core element of this project is the Electro Thermal Energy Storage (ETES) technology from Siemens Gamesa Renewable Energy GmbH, using thermally stable and inexpensive volcanic rocks as storage material and air as heat transfer medium. This technology is backed by more than 10 years of experience and a 440MMBTU (130MWh-th) pilot plant in Hamburg, Germany, which is in operation since 2019. The integration of this thermal storage in an existing combined cycle power plant (CCPP) is typical power plant technology without any major technology risks. It allows the storage of inexpensive renewable energy during times of surplus renewable generation and the discharge of this energy in times of high energy demand when the fossil plant is in operation. This supplements the fossil power generation with CO2-emission-free energy. The secondary effect of the CiTES system is that a small part of the stored thermal energy is used to keep the heat recovery steam generator (HRSG) and steam turbine (ST) of the combined cycle power plant in hot and ready-to-start condition. This enables the plant to start rapidly when fossil generation is required to satisfy demand as soon variable generation drops off in the evenings or during cloud cover and calm wind periods. Without pre-warming of the HRSG and ST, the CCPP would need several hours for a cold or warm start, burn a lot of gas and release high NOx emissions during start and wouldn’t be able to use the short times of high energy prices in an efficient or economical manner. The economic parameters of CiTES were determined by a full year “8760” simulation using a data set calculation for each of the hours of the year, and historical electricity and gas prices. For consistency, the simulations were focused on the pre-COVID year 2019. The financially most attractive markets were in the Energy Reliability Council of Texas (ERCOT) region, which allowed substantial value generation with arbitrage (charge with cheap energy during renewable surplus times and discharge when energy is needed and expensive). The improvement of flexibility with the CiTES system by pre-heating and warm-keeping of the CCPP allowed for additional power generation during short time periods when demand is high but renewable generation is down; when the hourly energy prices are highest in these markets. The simulations are based on 2019 data, when ERCOT had 27GW of installed photovoltaic (PV) and wind generation. They showed that the created revenue with the prototypically sized CiTES system of 1,000MMBTU (300MWh-th) falls a little bit short of what is expected from a commercially viable investment. The system has optimization opportunities for cost reduction and increased effectiveness which will be realized during a potential Phase II Pre-FEED study following this project. Furthermore, it is safe to assume that a lot of renewable generation capacity will be added all over the US in the coming years. As an example, ERCOT is predicting to more than double its renewable generation from 27GW in 2019 to a forecasted 63GW in 2023. This will increase the amount of renewable overproduction exponentially. This rapid increase of local overproduction and the need to curtail renewable generation is well documented by the California ISO (www.CAISO.com / managing oversupply). However, the simulations also revealed a weakness in the structure of the electricity markets in the US. More specifically, when electricity prices are very low and approaching negative levels, the owners of Variable Renewable Energy (VRE) will curtail a part of their facility to stabilize the price by reducing supply. This results in a situation in which storage facilities, which are integrated in existing fossil assets and don’t have the behind-the-meter benefit of a VRE, won’t be able to purchase low cost – otherwise curtailed – renewable energy off the grid. A special tariff, which motivates VRE owners to sell otherwise curtailed renewable energy to storage facilities (Hydrogen, thermal, pumped hydro, etc.) can solve this issue. The implementation of such a regulating tariff by Independent System Operators, thus avoiding renewable curtailment, is a pre condition for successful commercialization for renewable energy storage technologies. With this advancement of design and technology and improvements in the market environment, it can be expected that the Combined Cycle integrated Thermal Energy Storage proves itself as an important innovation to keep highly efficient, natural gas-based power generation economically successful and relevant for the power industry in the United States of America.

Wolf, Thorsten↗

Hybrid renewable energy systems: the value of storage as a function of PV-wind variability

As shares of variable renewable energy (VRE) on the electric grid increase, sources of grid flexibility will become increasingly important for maintaining the reliability and affordability of electricity supply. Lithium-ion battery energy storage has been identified as an important and cost-effective source of flexibility, both by itself and when coupled with VRE technologies like solar photovoltaics (PV) and wind. In this study, we explored the current and future value of utility-scale hybrid energy systems comprising PV, wind, and lithium-ion battery technologies (PV-wind-battery systems). Using a price-taker model with simulated hourly energy and capacity prices, we simulated the revenue-maximizing dispatch of a range of PV-wind-battery configurations across Texas, from the present through 2050. Holding PV capacity and point-of-interconnection capacity constant, we modeled configurations with varying wind-to-PV capacity ratios and battery-to-PV capacity ratios. We found that coupling PV, wind, and battery technologies allows for more effective utilization of interconnection capacity by increasing capacity factors to 60%–80%+ and capacity credits to close to 100%, depending on battery capacity. We also compared the energy and capacity values of PV-wind and PV-wind-battery systems to the corresponding stability coefficient metric, which describes the location-and configuration-specific complementarity of PV and wind resources. Our results show that the stability coefficient effectively predicts the configuration-location combinations in which a smaller battery component can provide comparable economic performance in a PV-wind-battery system (compared to a PV-battery system). These PV-wind-battery hybrids can help integrate more VRE by providing smoother, more predictable generation and greater flexibility.

14 SOLAR ENERGY↗

Techno-economic Analysis of the Cryogenic Flux Capacitor Compared to Other forms of Hydrogen Production and Storage

The Cryogenic Flux Capacitor (CFC) is a cold, dense energy storage core that is being studied in the cryo-compressed, about 300 bar and 80K, region of gaseous hydrogen (GH2) storage and liquid hydrogen (LH2) region near the normal boiling point. The hydrogens storage is improved by physically bonding the molecules within the nanoscale pores of the aerogel composite blanket material. The process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (~1,000 m2/g) allows its storage performance to easily exceed capacities of high-pressure GH2 storage for an equivalent volume. With the integrated aerogel, subscale tests have shown that storage is increased by about 49% over a simple tank filled with GH2 at the same operating temperature and pressure. For LH2 conditions, the CFC is shown to operate at equivalent densities. For the techno-economic analysis (TEA), the source of hydrogen is compared between onsite steam methane reforming (SMR) and onsite solar photovoltaic (PV) panels providing power to electrolyzers to produce GH2. The TEA compares pure hydrogen burning in a combined cycle gas turbine (CCGT) to hydrogen fuel cells with an overall net power output of 650 MW. The SMR system uses natural gas as an input and includes a carbon capture and storage (CCS) system. The levelized cost of electricity is developed based on the capital cost and operating cost of the systems. Sensitivities are discussed around the cost of natural gas, ranging from 1.93 USD per MMBTU to 6.75 USD per MMBTU, and carbon dioxide disposal, ranging from 7 USD per tonne to 10 USD per tonne. For comparison to the conventional CCGT baseline, a baseload scenario is adopted with 85% capacity factor. The results of the study show that onsite hydrogen generation from SMR is about 1 to 3 USD per kg over the life of the plant and the PV hydrogen production produces at 4 to 5 USD per kg. The cost of storage for CFC is compared to other systems, including high-pressure GH2 and atmospheric LH2. The system is shown to provide the lowest costs for all these options at the grid scale, due to its higher capacity than high-pressure GH2 and ability to operate at 80K, receiving refrigeration from liquid nitrogen systems reducing capital and operating costs when compared LH2 storage systems. SMR is competitive with CCGT at the gas prices, both of which have lower LCOE than the PV system. When accounting for variability in gas prices, the PV and electrolyzer system is less sensitive to these changes and provides the lowest LCOE across the whole range.

08 HYDROGEN↗