Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURE DROP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Impact of aspect ratio on flow boiling of water in rectangular microchannels

In this paper we focus on the impact of varying the aspect ratio of rectangular microchannels, on the overall pressure drop involving water boiling. An integrated system comprising micro-heaters, sensors and microchannels has been realized on (110) silicon wafers, following CMOS compatible process steps. Rectangular microchannels were fabricated with varying aspect ratios (width [W] to depth [H]) but constant hydraulic diameter of 142{+-}2{mu}m and length of 20 mm. The invariant nature of the hydraulic diameter is confirmed through two independent means: physical measurements using profilometer and by measuring the pressure drop in single-phase fluid flow. The experimental results show that the pressure drop for two-phase flow in rectangular microchannels experiences minima at an aspect ratio of about 1.6. The minimum is possibly due to opposing trends of frictional and acceleration pressure drops, with respect to aspect ratio. In a certain heat flux and mass flux range, it is observed that the two-phase pressure drop is lower than the corresponding single-phase value. This is the first study to investigate the effect of aspect ratio in two-phase flow in microchannels, to the best of our knowledge. The results are in qualitative agreement with annular flow model predictions. These results improve the possibility of designing effective heat-sinks based on two-phase fluid flow in microchannels. (author)

42 ENGINEERING↗

Comparison of High Aspect Ratio Cooling Channel Designs for a Rocket Combustion Chamber

An analytical investigation on the effect of high aspect ratio (height/width) cooling channels, considering different coolant channel designs, on hot-gas-side wall temperature and coolant pressure drop for a liquid hydrogen cooled rocket combustion chamber, was performed. Coolant channel design elements considered were: length of combustion chamber in which high aspect ratio cooling was applied, number of coolant channels, and coolant channel shape. Seven coolant channel designs were investigated using a coupling of the Rocket Thermal Evaluation code and the Two-Dimensional Kinetics code. Initially, each coolant channel design was developed, without consideration for fabrication, to reduce the hot-gas-side wall temperature from a given conventional cooling channel baseline. These designs produced hot-gas-side wall temperature reductions up to 22 percent, with coolant pressure drop increases as low as 7.5 percent from the baseline. Fabrication constraints for milled channels were applied to the seven designs. These produced hot-gas-side wall temperature reductions of up to 20 percent, with coolant pressure drop increases as low as 2 percent. Using high aspect ratio cooling channels for the entire length of the combustion chamber had no additional benefit on hot-gas-side wall temperature over using high aspect ratio cooling channels only in the throat region, but increased coolant pressure drop 33 percent. Independent of coolant channel shape, high aspect ratio cooling was able to reduce the hot-gas-side wall temperature by at least 8 percent, with as low as a 2 percent increase in coolant pressure drop. The design with the highest overall benefit to hot-gas-side wall temperature and minimal coolant pressure drop cooling can now be done in relatively short periods of time with multiple iterations.

Wadel, Mary F.↗

Comprehensive experimental investigation on biomass-glass beads binary fluidization: A data set for CFD model validation

Fluidization behavior of biomass and glass beads binary mixtures in a bubbling fluidized bed was experimentally investigated. Mixtures containing different mass fraction of Loblolly Pine white wood and glass beads were fluidized at different fluidization velocities. The particle properties were characterized in a QICPIC that uses a dynamic image processing method to measure both particle size and sphericity. The minimum fluidization velocity was determined using the pressure drop method. An image processing method was developed to capture the dynamic expanded bed height at a very high frequency. The effect of biomass mass fraction and inlet gas velocity on mixing and segregation behavior was studied and analyzed through pressure drop measurements. Pressure drop fluctuations and expanded bed height fluctuations via fast Fourier transform were analyzed and compared. Here, the complete and accurate experimental data reported in this study could provide a benchmark data set for various computational fluid dynamics models validation, calibration, and identification.

42 ENGINEERING↗

Antimisting kerosene: Low temperature degradation and blending

The inline filtration characteristics of freshly blended and degraded antimisting fuels (AMK) at low temperature are examined. A needle valve degrader was modified to include partial recirculation of degraded fuel and heat addition in the bypass loop. A pressure drop across the needle valve of up to 4,000 psi was used. The pressure drop across a 325 mesh filter screen placed inline with the degrader and directly downstream of the needle valve was measured as a function of time for different values of pressure drop across the needle valve. A volume flux of 1 gpm/sq in was employed based on the frontal area of the screen. It was found that, at ambient temperatures, freshly blended AMK fuel could be degraded using a single pass degradation at 4,000 psi pressure drop across the needle valve to give acceptable filterability performance. At fuel temperatures below -20 C, degradation becomes increasingly difficult and a single pass technique results in unacceptable filtration performance. Recirculation of a fraction of the degraded fuel and heat addition in the bypass loop improved low temperature degradation performance. The problem is addressed of blending the AMK additive with Jet A at various base fuel temperatures.

Yavrouian, A.↗

Development of a Kalman filter estimator for simulation and control of particulate matter distribution of a diesel catalyzed particulate filter

The knowledge of the temperature and particulate matter mass distribution is essential for monitoring the performance and durability of a catalyzed particulate filter. A catalyzed particulate filter model was developed, and it showed capability to accurately predict temperature and particulate matter mass distribution and pressure drop across the catalyzed particulate filter. However, the high-fidelity model is computationally demanding. Therefore, a reduced order multi-zone particulate filter model was developed to reduce computational complexity with an acceptable level of accuracy. In order to develop a reduced order model, a parametric study was carried out to determine the number of zones necessary for aftertreatment control applications. The catalyzed particulate filter model was further reduced by carrying out a sensitivity study of the selected model assumptions. The reduced order multi-zone particulate filter model with 5 × 5 zones was selected to develop a catalyzed particulate filter state estimator considering its computational time and accuracy. Next, a Kalman filter–based catalyzed particulate filter estimator was developed to estimate unknown states of the catalyzed particulate filter such as temperature and particulate matter mass distribution and pressure drop (Δ P) using the sensor inputs to the engine electronic control unit and the reduced order multi-zone particulate filter model. A diesel oxidation catalyst estimator was also integrated with the catalyzed particulate filter estimator in order to provide estimates of diesel oxidation catalyst outlet concentrations of NO 2 and hydrocarbons and inlet temperature for the catalyzed particulate filter estimator. The combined diesel oxidation catalyst–catalyzed particulate filter estimator was validated for an active regeneration experiment. The validation results for catalyzed particulate filter temperature distribution showed that the root mean square temperature error by using the diesel oxidation catalyst–catalyzed particulate filter estimator is within 3.2 °C compared to the experimental data. Similarly, the Δ P estimator closely simulated the measured total Δ P and the estimated cake pressure drop error is within 0.2 kPa compared to the high-fidelity catalyzed particulate filter model.

Engineering↗

RSRM 10 percent Scale Model Drilled Hole Plate Tests

The RSRM 10% Scaled Model under design will make use of drilled hole liners to provide mass addition along the axial length of the model. The model will have two sets of liners in use at a time. The outer most liner is a flow distribution tube, the purpose of which is to help distribute the flow evenly over each model segment. The inner most liner will simulate the propellant burning surface at a burn time of 80 seconds. This liner will replicate as closely as possible the actual geometry of the full scale RSRM at the 80 second burn time. In order to obtain the correct mass flow rate for the burn time selected, it is necessary to determine the porosity of the holes drilled in each liner and the performance of those holes. The pressure drop across the liners directly effects the uniformity of the flow in the axial direction for a given model section. It is desired to have a pressure drop across the liners which is greater than the axial pressure drop in a given section. However, the pressure drop across the liner also has a bearing on the structural soundness of the model. The performance of the model was determined analytically, but there was some uncertainty as to the value of the discharge coefficient used. This uncertainty was the impetus for these drilled hole plate tests. Experimentally obtaining the discharge coefficients for sample plates of the porosity to be used in the model would increase the fidelity of the model design. These tests were developed in order to provide the required information with the least amount of testing time and hardware.

Purinton, David C.↗

Carbonate formation on Mars: Latest experiments

Laboratory simulations of Martian CO2 storage address whether carbonate formation could have reduced CO2 pressure from a hypothetical greater than 1 bar to the present 7 mbar in less than or equal to 3 to 4 billion years. This problem is addressed with experiments and analysis designed to verify and improve previous kinetic measurements, reaction mechanisms, and product characterizations, with the goal of improving existing models of Martian CO2 history. A sensitive manometer monitored the pressure drop of CO2 due to uptake by powdered silicate for periods of 3 to 100+ days. Pressure drops for diopside 1 and basalt show rapid short-term (approximately one day) CO2 uptake and considerably slower long-term pressure drops. Curves for diopside 2, olivine 1, and olivine 2 are qualitatively similar to those for diopside 1, whereas quartz and plagioclase show near-zero short-term pressure drops and very slow long-term signals, indistinguishable from a leak (less than 10(exp 11) mol/sq m/s).

Stephens, S. K.↗

LLNL HEPA Filter Support of Nuclear Facility Safety R&D (FY12)

The ceramic HEPA filter project has been a successful and innovative project. This report contains information from the work from FY12 funding, as well as remaining FY11 funding. Of note, a total of 12 patents for the ceramic HEPA filter program have been filed, and an additional record of invention has been prepared with a provisional patent to follow. This project supports development of a ceramic HEPA filter technology to benefit DOE nuclear facilities by providing lower life-cycle costs and reducing or eliminating costs associated with Safety Class and Safety Significant systems in nuclear facilities. The satisfactory performance of ceramic filters in a fire could significantly reduce costs of support systems associated with mitigating a release, such as fire suppression, fire detection and alarm, and internal building structure. In nuclear safety, the best way to provide protection to public, workers and the environment is to provide a barrier between the hazard and the receptors. A passive engineered design feature is the best barrier for that purpose. Advanced ceramic HEPA filters provide an excellent barrier between radioactive material in a nuclear facility and everything downwind. Both university (Cal Poly) student teams did very well. As summarized in this report, they successfully added and upgraded instrumentation and controls to the High Temperature Test Unit (HTTU) for the ceramic filter project. They also succeeded in adding viewing ports, remotely controlled closed circuit television, a flame impingement system and a helium filter gasket leak detection system. Details can be found in Ref. 3 - 6. The HTTU has flexible capabilities and can also be used to test other types of filters or filter components in the future, if so desired. At LLNL, research to improve filter media coating (Fig. 1) is being conducted to maintain filtration efficiency while improving performance (reducing pressure drop). Improvements in the individual filter element are necessary to maintain filtration efficiency while decreasing pressure drop. The path forward for an optimal ceramic HEPA filter meeting DOE’s needs is to improve the filtration media. This task utilized the LLNL/DOE developed innovations along with progress in previous activities to prepare multiple ceramic filter elements and refine the technical details for depositing advanced filtration materials to the ceramic filter to meet desired filter performance. The ceramics filter elements were tested for pressure drop at the required air flow rate using an air flow test system. The filtration efficiency and pressure drop of the ceramic filter elements will be measured as part of the development process.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental and numerical investigation of sands and Geldart A biomass co-fluidization

This study investigated the fluidization of sands and small Geldart A biomass mixtures. The mixture fluidized like Geldart A type particles with a uniform bed expansion regime before bubbling. The video recorded color distance between pure sands and sands–biomass mixtures was used to estimate the sands–biomass mixing. The coarse-grained computational fluid dynamics–discrete element method with a hybrid drag model which couples the Syamlal–O'Brien drag and a filtered drag can capture the mixing while the simulation with Gidaspow drag predicted a segregated bed. The simulations were further validated with experimental measured pressure drops. The time averaged pressure drop equals the weight of the bed material, however, its fluctuation is about three times of the bed material fluctuation.

42 ENGINEERING↗

Experimental Investigation of Hydraulic Fracturing and Stress Sensitivity of Fracture Permeability Under Changing Polyaxial Stress Conditions

Understanding and predicting fracture propagation and subsequent fluid flow characteristics is critical to geoenergy technologies that engineer and/or utilize favorable geological conditions to store or extract fluids from the subsurface. Fracture permeability decreases nonlinearly with increasing normal stress, but the relationship between shear displacement and fracture permeability is less well understood. We utilize the new Geo–Reservoir Experimental Analogue Technology (GREAT cell), which can apply polyaxial stress states and realistic reservoir temperatures and pressures to cylindrical samples and has the unique capability to alter both the magnitude and orientation of the radial stress field by increments of 11.25° during an experiment. We load synthetic analogue materials and real rock samples to stress conditions representative of 500–1,000 m depth, investigate the hydraulic stimulation process, and then conduct flow experiments while changing the fluid pressure and the orientation of the intermediate and minimum principal stresses. High–resolution circumferential strain measurements combined with fluid pressure data indicate fracture propagation can be both stable (no fluid pressure drop) and unstable (fluid pressure drop). The induced fractures exhibit both opening and shear displacements during their creation and/or during fluid flow with changing radial stress states. Flow tests during radial stress field rotation reveal that fracture normal effective stress has first–order control on fracture permeability but increasing fracture offset can lead to elevated permeabilities at maximum shear stress. Here, the results have implications for our conceptual understanding of fracture propagation as well as fluid flow and deformation around fractures.

58 GEOSCIENCES↗

TU-H-CAMPUS-IeP2-03: Development of 3D Printed Coronary Phantoms for In-Vitro CT-FFR Validation Using Data from 320- Detector Row Coronary CT Angiography

Purpose: To validate Computed Tomography Fractional Flow Reserve (CT-FFR) measurements with accurate 3D printed coronary phantoms. Methods: DICOM data from four phases in two patients imaged with a standard 320 × 0.5mm coronary CT acquisition (70–80% cardiac cycle) underwent semi-automated segmentation using a research workstation. Both patients had a >50% stenosis from the clinical image interpretation. Each volume was saved as a Stereo Lithographic (STL) file with 250 micron resolution. The 3D geometries were qualitatively assessed; the best of the four phases was 3D printed using a Stratasys Eden260V printer in Tango+, a rubber-like material that roughly emulates mechanical properties of human vasculature. We connected the model to a programmable pump and measured the pressure drop using pressure sensors embedded proximal and distal to the arterial stenosis. Next, the STL files used for the 3D printed models were uploaded in the ANSYS meshing tool (ICEM CFD 16.1). A standard meshing process was applied and the meshed geometry was directly imported in the ANSYS Fluent for Computational Flow Dynamics simulations. The CFD simulations were used to calculate the CT-FFR and compared to the bench top FFR measured in the 3D printed phantoms. Results: FFR-CT measurements and phantoms were completed in within an hour after the segmentation. Patient 1 had a 60% stenosis that resulted in a CT-FFR of 0.68. The second case had a 50% stenosis and a CT-FFR of 0.75. The average bench top FFR measurements were 0.72 and 0.80, respectively. Conclusion: This pilot investigation demonstrated the use of a bench-top coronary model for CT-FFR validation. The measurements and the CFD simulations agreed within 6%. Project supported by Support: Toshiba America Medical Systems Corp.and NIH grant R01-EB002873. Project supported by Toshiba America Medical Systems Corp.and partial support from NIH grant R01-EB002873.

60 APPLIED LIFE SCIENCES↗

Filtration Performance Results: Sierra Peaks Material No. 4

Sandia National Laboratories (SNL) assessed the filtration performance of materials from Sierra Peaks to identify alternatives which may perform similarly to materials used in FDA-approved N95 respirators. This work is meant to characterize the aerosol performance of materials to give Sierra Peaks information for them to determine if they elect to submit masks made using these materials for follow-on N95 certification testing at an accredited facility. The R&D testbed used is a large-scale filtration system designed to test commercial filter boxes. System modifications were performed to simulate, where possible, parameters defined by the National Institute for Occupational Safety and Health (NIOSH) for certification of filter materials for N95 respirators (NIOSH 2019). The system is a pull-through design. Air enters through a Laminar Flow Element (LFE) and the volumetric flow is measured based on the pressure drop across the LFE. Pressure is measured via a Pressure Transducer (PT). The air then passes through a High Efficiency Particulate Air (HEPA) filter to purge the air of ambient airborne particulates. Test aerosol is injected into the flow shortly after and mixing is induced via a coarse mesh. The airflow is allowed to fully develop prior to arriving at the test section. The aerosol then passes through the test material mounted in a box in the test section. Pressure drop across the test article is measured and aerosol sampling probes measure the aerosol concentrations upstream and downstream of the sample. The air passes through a second HEPA filter prior to being exhausted to ambient by a blower. A Topas aerosol generator is used to produce the test aerosol from Sodium Chloride (NaC1) dissolved in deionized (DI) water. Generated aerosol passes through a heated mixing chamber and a desiccant dryer to produce nanosized solid-state particulates. A dilution loop allows for the aerosol concentration to be regulated. The aerosol sampling probes upstream and downstream of the test section are aligned with the flow path. These are ducted directly to the aerosol sizing and counting instruments. A Laser Aerosol Spectrometer (LAS) was used for data collection in the original configuration of the system and was also used for initial testing in this project. Because the lower measurement range for the LAS is 90 nanometers (nm), the LAS was switched out for a more complicated Scanning Mobility Particle Sizer (SMPS) spectrometer system. The SMPS is comprised of an Electrostatic Classifier (EC), Differential Mobility Analyzer (DMA), and a Condensation Particle Counter (CPC). This enabled data collection at 75 nm, the particle size called out in the NIOSH guidelines.

36 MATERIALS SCIENCE↗

A Phenomenological Model for Cavitation

A phenomenological model of cavitation is presented, based on observations that both large relative negative pressures and large negative time derivatives of pressure are required for cavitation onset. We simulated two cavitation experiments to generate cavitation scaling parameters for relative pressure drop and rate of pressure drop. Our results show the model, while simple, is effective at reproducing results from laboratory experiments of cavitation. The parameters were then used in conjunction with a human surrogate computational model to predict, at any position within the head, the probability of intracranial cavitation caused by exposure to a blast event. The results suggest that the magnitude of blast overpressure observed in field data is sufficient to cause intracranial cavitation. Our analysis indicates that the helmeted head, when compared to the unhelmeted head configuration, results in a decrease but not elimination of cavitation exposure. When density functions of cavitation probability versus cumulative brain volume are combined with an injury severity model, the results show helmet efficacy at low and moderate risk levels. However, the convergence of unhelmeted and helmeted probability density functions at high-to-excessive risk thresholds indicates the helmet offers diminishing protection at elevated exposure levels, relative to the unhelmeted baseline. Future investigation and collaboration with neuroscience subject matter experts are needed to contextualize the current computational results. While the present work contributes specific and quantified predictions of intracranial cavitation location and severity, more research is required to apply our results to clinical settings with population-based brain injury subjects and controls. The relationship between our intracranial cavitation predictions with their anticipated clinical sequelae remains a topic in need of exploration.

60 APPLIED LIFE SCIENCES↗

Heat Exchanger Intensification Through Powder Processing and Enhanced Design (HIPPED)

High intensity, supercritical CO 2 heat exchangers capable of operating at temperatures between 800 and 1100 ˚C and pressures greater than 80 bar are considered a critical component for high efficiency power generation and a range of next-generation industrial processes. A novel heat exchanger concept was proposed in this project. The proposed concept involved a plate-type architecture with three-dimensional fins, called twisted s-shaped fins, that capitalize on additive manufacturing. Four manufacturing processes were studied to realize the complex envisioned design: press and sinter of metallic powders, directed energy deposition, laser powder bed fusion, and a novel powder bed process involving a photoreactive polymer called SEAM (scalable expeditious additive manufacturing), that later was developed at MSU. The team was able to manufacture subscale heat exchangers using laser powder bed fusion (LPBF) and SEAM. The team settled on using SEAM as a final manufacturing approach due to its very low cost. The SEAM-manufactured heat exchanger, however, when tested under pressure, exhibited leaks and the process still requires further development beyond the timeline of the project. To support the heat exchanger design and testing, the team developed a new high temperature flow loop allowing testing under high temperature and pressure. Computational modeling of the heat exchanger was also performed for the twisted s-shaped fins and the computations were validated with experimental data. The new twisted fins resulted in enhanced heat transfer and reduced pressure drop. To further minimize pressure drop in the plate heat exchanger, the team also developed a simplified model for flow maldistribution in the manifolds, providing a new tool for designers that eliminates the need for complex CFD calculations. A technoeconomic analysis was also developed to contrast SEAM with LPBF, this tool indicated that SEAM is several times less costly and offer significant promises as a rapid low cost additive manufacturing process for metallic systems.

30 DIRECT ENERGY CONVERSION↗

Initial comparison of single cylinder Stirling engine computer model predictions with test results

A NASA developed digital computer code for a Stirling engine, modelling the performance of a single cylinder rhombic drive ground performance unit (GPU), is presented and its predictions are compared to test results. The GPU engine incorporates eight regenerator/cooler units and the engine working space is modelled by thirteen control volumes. The model calculates indicated power and efficiency for a given engine speed, mean pressure, heater and expansion space metal temperatures and cooler water inlet temperature and flow rate. Comparison of predicted and observed powers implies that the reference pressure drop calculations underestimate actual pressure drop, possibly due to oil contamination in the regenerator/cooler units, methane contamination in the working gas or the underestimation of mechanical loss. For a working gas of hydrogen, the predicted values of brake power are from 0 to 6% higher than experimental values, and brake efficiency is 6 to 16% higher, while for helium the predicted brake power and efficiency are 2 to 15% higher than the experimental.

Tew, R. C., Jr.↗

Labyrinth seal forces on a whirling rotor

An experimental investigation of air labyrinth seal forces on a subsynchronously whirling model rotor is described and test results are given for diverging, converging, and straight two-strip seals. The effects of pressure drop, back pressure, whirl direction, and whirl frequency are shown. These results provide basic experimental data needed in the development of design methods for predicting and preventing self-excited whirl of turbine rotors and other machines having labyrinth seals. The total dynamic seal forces on the whirling model rotor are measured accurately by means of a novel active damping and stiffness system that is adjusted to obtain neutral whirl stability of the model rotor system. In addition, the whirling pressure pattern in the seal annulus is measured for a few test conditions and the corresponding pressure forces on the rotor are compared with the total measured forces. This comparison shows that either radial and axial pressure gradients in the seal annulus or drag forces on the rotor are significant.

Wright, D. V.↗

Combustion Stability Characteristics of the Project Morpheus Liquid Oxygen / Liquid Methane Main Engine

The project Morpheus liquid oxygen (LOX) / liquid methane (LCH4) main engine is a Johnson Space Center (JSC) designed ~5,000 lbf-thrust, 4:1 throttling, pressure-fed cryogenic engine using an impinging element injector design. The engine met or exceeded all performance requirements without experiencing any in- ight failures, but the engine exhibited acoustic-coupled combustion instabilities during sea-level ground-based testing. First tangential (1T), rst radial (1R), 1T1R, and higher order modes were triggered by conditions during the Morpheus vehicle derived low chamber pressure startup sequence. The instability was never observed to initiate during mainstage, even at low power levels. Ground-interaction acoustics aggravated the instability in vehicle tests. Analysis of more than 200 hot re tests on the Morpheus vehicle and Stennis Space Center (SSC) test stand showed a relationship between ignition stability and injector/chamber pressure. The instability had the distinct characteristic of initiating at high relative injection pressure drop at low chamber pressure during the start sequence. Data analysis suggests that the two-phase density during engine start results in a high injection velocity, possibly triggering the instabilities predicted by the Hewitt stability curves. Engine ignition instability was successfully mitigated via a higher-chamber pressure start sequence (e.g., ~50% power level vs ~30%) and operational propellant start temperature limits that maintained \cold LOX" and \warm methane" at the engine inlet. The main engine successfully demonstrated 4:1 throttling without chugging during mainstage, but chug instabilities were observed during some engine shutdown sequences at low injector pressure drop, especially during vehicle landing.

Melcher, John C.↗

Atmospheric, Non-Combusting Droplet Sizing and Spray Imaging Results From a Non-Proprietary Aero Gas Turbine Engine Pressure Swirl Atomizer using Shadowgraphy and Planar Laser Scatter

Members from industry and federal agencies of the United States have developed a collaborating group focused on improving the understanding of the atomization processes common to gas turbine engines. The group is aimed on providing high quality data using x-ray diagnostics in the internal geometry and the near-field dense spray as well as optical diagnostics in the visible spectrum, downstream of the nozzle. This paper reports results from one of the two non-proprietary injectors designs from the group: the primary-secondary injector. In particular, we characterize the spray from only the primary, pressure-swirl atomizing circuit using water through the nozzle. We observed Sauter mean diameter decreased with increased water pressure drop across the nozzle. SMD was also collected at three axial distances and showed decreased size with distance from the nozzle. Planar laser sheet droplet scattering provided qualitative assessment of the spray. Higher water pressure drops provided better atomization than lower pressure drops. The addition of swirling air flow through the injector alleviates and improves the atomization quality, particularly at the lower water pressure drops.

optical diagnostics↗