Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLUGGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Scalable synthesis of palladium icosahedra in plug reactors for the production of oxygen reduction reaction catalysts

We have synthesized Pd icosahedra with uniform, controllable sizes in plug reactors separated by air. The oxygen contained in the air segments not only contributed to the generation of a reductant from diethylene glycol in situ, but also oxidized elemental Pd back to the ionic form by oxidative etching and thus slowed down the reduction kinetics. Compared to droplet reactors involving silicone oil or fluorocarbon, the use of air as a carrier phase could reduce the production cost by avoiding additional procedures for the separation of products from the oil. The average diameters of the Pd icosahedra could be readily controlled in the range of 12–20 nm. The Pd icosahedra were further employed as seeds for the production of Pd@Pt 2–3L core-shell icosahedra, which could serve as a catalyst toward the oxygen reduction reaction with greatly enhanced activity. As a result, we believe that the plug reactors could be extended to other types of noble-metal nanocrystals for their scale-up production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Embolization of the Gastroduodenal Artery Before Selective Internal Radiotherapy: A Prospectively Randomized Trial Comparing Platinum-Fibered Microcoils with the Amplatzer Vascular Plug II

The Amplatzer Vascular Plug II (AVP II) is a novel device for transcatheter vessel occlusion, for which only limited comparative data exist. Embolotherapy of the gastroduodenal artery (GDA) is essential before internal radiotherapy (SIRT) in order to prevent radiation-induced peptic ulcerations due to migration of yttrium-90 microspheres. The purpose of this study was to compare the vascular anatomical limitations, procedure time, effectiveness, and safety of embolization of the GDA with coils versus the AVP II. Fifty patients stratified for SIRT were prospectively randomized for embolization of the GDA with either coils or the AVP II. The angle between the aorta and the celiac trunk, diameter of the GDA, fluoroscopy time and total time for embolization, number of embolization devices, complications, and durability of vessel occlusion at follow-up angiography for SIRT were recorded. A t-test was used for statistical analysis. Embolizations with either coils or the AVP II were technically feasible in all but two patients scheduled for embolization of the GDA with the AVP II. In both cases the plug could not be positioned due to the small celiac trunk outlet angles of 17{sup o} and 21{sup o}. The mean diameter of the GDA was 3.7 mm (range, 2.2-4.8 mm) for both groups. The procedures differed significantly in fluoroscopy time (7.8 min for coils vs. 2.6 min for the AVP II; P < 0.001) and embolization time (23.1 min for coils vs. 8.8 min for the AVP II; P < 0.001). A mean of 6.0 {+-} 3.2 coils were used for GDA embolization, while no more than one AVP II was needed for successful vessel occlusion (P < 0.001). One coil migration occurred during coil embolization, whereas no procedural complication was encountered with the use of the AVP II. Vessel reperfusion was noted in only one patient, in whom coil embolization was performed. In conclusion, embolization of the GDA with the AVP II is safe, easy, rapid, and highly effective; only an extremely sharp-angled celiac trunk outlet represented an anatomical limitation for device deployment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The AMPLATZER Vascular Plug 4: Preliminary Experience

The purpose of this communication is to describe our preliminary experience with the AMPLATZER Vascular Plug 4 (AVP 4) in peripheral vascular embolization. The AVP 4 was used for peripheral vascular embolization in five patients with renal pseudoaneurysm (n = 2), postsurgical peritoneal bleeding (n = 1), posttraumatic gluteal hemorrhage (n = 1), and intercostal pseudoaneurysm (n = 1). Occlusion time was recorded. Patients were followed up clinically and by imaging for 1 month after the procedure. All treated vessels or vascular abnormalities were successfully occluded within 3 min for low-flow circulation and over 8 min for high-flow circulation. At 1-month follow-up, all patients were symptom-free. All deployed devices remained in the original locations and desirable configurations. In conclusion, the AVP 4 seems to be safe and effective for occluding peripheral vessels and vascular abnormalities. Because of its compatibility with 0.038-in. catheters, it can be deployed through a diagnostic catheter following angiography without exchanging a sheath or guiding catheter. Compared with the previous generation of vascular plugs, the AVP 4 allows for faster procedure times and decreased exposure to radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aneurysm of an Anomalous Systemic Artery Supplying the Normal Basal Segments of the Left Lower Lobe: Endovascular Treatment with the Amplatzer Vascular Plug II and Coils

An anomalous systemic artery originating from the descending thoracic aorta supplying the normal basal segments of the lower lobe of the left lung without sequestration is a rare congenital anomaly. The published surgical treatments include lobectomy, segmentectomy, anastomosis, and ligation. In addition, endovascular treatment with coils has been reported. A second-generation occluder, the Amplatzer Vascular Plug II (AVP II), has a central plug and two occlusion disks and a finer, more densely woven nitinol wire, thus enabling faster embolization. This published case is the first successful occlusion of an aneurysm of an anomalous systemic artery with the AVP II and fibered coils, with 10 months of follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of Nozzle Radial Position, Separation Angle, and Gas Flow Partitioning on the Mixing, Eye Area, and Wall Shear Stress in Ladles Fitted with Dual Plugs

Mixing time, slag eye area, and wall shear stress in a ladle fitted with dual plugs have been studied as a function of operating variables, namely, gas flow rate, radial nozzle position, separation angle between nozzles and flow rate partitioning. While the mixing time and slag eye area have been experimentally investigated in a scaled water model (with and without a top slag layer), the shear stress on the vessel wall has been studied computationally via a RANS-based turbulent, three-dimensional coupled Eulerian–Lagrangian (VOF-DPM), multiphase flow model. Experimental and computational results have indicated that the mixing, eye area, and wall shear stress depend on the gas flow rate, i.e., while mixing efficiency increases with the increasing gas flow rate, the slag eye area, and wall shear stress, in contrast, become more pronounced with the increasing gas flow, leading to an undesirable operating regime. The radial nozzle position, separation angle between the nozzles and flow rate partitioning at any given flow rate also influence the ladle process performance, influencing the mixing, eye area, and wall shear stress, albeit to a varied degree. Within the range of operating conditions studied, an expected inverse correspondence between mixing time and shear behavior was observed. Experimental and computational results in conjunction have indicated that the best arrangement of porous plugs or gas injection nozzles for superior ladle process performance is dependent on the gas flow rate and is specific to the desired objective (i.e., decreasing the mixing time, or slag eye area and wall shear stress). Hence, a unique gas injection practice cannot and should not be suggested as the optimum for ladle metallurgy in steelmaking. Nevertheless, if the mixing time is the parameter of primary interest, a nozzle configuration with equal flow partitioning (1:1) between the nozzles and identical nozzle radial positions (0.7R/0.7R, 45 deg) should suffice for both low and high gas flow rates. In contrast, a nonidentical nozzle radial position (0.7R/0.5R, 90 deg) and an unequal gas flow rate per nozzle (1:3) appear preferable if both ladle eye and shear stresses, rather than mixing, are the issues of concern.

36 MATERIALS SCIENCE↗

Heat activates the AAA+ HslUV protease by melting an axial autoinhibitory plug

At low temperatures, protein degradation by the AAA+ HslUV protease is very slow. New crystal structures reveal that residues in the intermediate domain of the HslU 6 unfoldase can plug its axial channel, blocking productive substrate binding and subsequent unfolding, translocation, and degradation by the HslV 12 peptidase. Biochemical experiments with wild-type and mutant enzymes support a model in which heat-induced melting of this autoinhibitory plug activates HslUV proteolysis.

59 BASIC BIOLOGICAL SCIENCES↗

Nanoscopic Plugs Block Hydrogen Crossover in Submicron Thick Proton-Conducting SiO 2 Membranes for Water Electrolysis

Zero-gap electrolyzers based on submicron thick proton-conducting oxide membranes (POMs) represent a promising approach to increasing the efficiency of H 2 production from water electrolysis while moving away from conventional perfluorosulfonic acid (PFSA) membranes. A critical barrier to the commercialization of such electrolyzers is that the ultrathin nature of POMs, which is necessary to achieve low cell resistance, makes them more susceptible to defects that can lead to unacceptably high rates of H 2 crossover. Herein, we demonstrate an approach to mitigate this problem through selective deposition of carbon-containing silicon oxide (SiO x C y ) “nanoplugs” into the defects of submicron thick SiO 2 membranes using a facile electrochemically mediated deposition process. Selective deposition of nanoplugs within the defects was verified by multiple characterization techniques, while scanning electrochemical microscopy (SECM) was used to confirm selective plugging of H 2 -crossover hotspots associated with defects at identical locations. Thanks to the use of nanoplugs, the H 2 permeance of 250 nm thick SiO 2 membranes was reduced by 5 to 6 orders of magnitude compared to the unmodified atomic layer deposition (ALD) SiO 2 membranes while having negligible impact on the ionic resistance of the membrane. These plug-modified membranes also enabled safe and stable operation of a zero-gap full cell electrolysis cell, in contrast to cells lacking nanoplugs that produced anode effluent streams having H 2 concentrations near or exceeding the lower flammability limit (LFL) of H 2 . Furthermore, beyond water electrolysis, this defect-sealing strategy has the potential to be broadly implemented in other applications, such as fuel cells and flow batteries, offering a versatile solution to mitigate crossover-related performance losses.

ALD SiO2↗

Laterally Mobile, Functionalized Self-Assembled Monolayers at the Fluorous−Aqueous Interface in a Plug-Based Microfluidic System: Characterization and Testing with Membrane Protein Crystallization

This paper describes a method to generate functionalizable, mobile self-assembled monolayers (SAMs) in plug-based microfluidics. Control of interfaces is advancing studies of biological interfaces, heterogeneous reactions, and nanotechnology. SAMs have been useful for such studies, but they are not laterally mobile. Lipid-based methods, though mobile, are not easily amenable to setting up the hundreds of experiments necessary for crystallization screening. Here we demonstrate a method, complementary to current SAM and lipid methods, for rapidly generating mobile, functionalized SAMs. This method relies on plugs, droplets surrounded by a fluorous carrier fluid, to rapidly explore chemical space. Specifically, we implemented his-tag binding chemistry to design a new fluorinated amphiphile, RfNTA, using an improved one-step synthesis of RfOEG under Mitsunobu conditions. RfNTA introduces specific binding of protein at the fluorous-aqueous interface, which concentrates and orients proteins at the interface, even in the presence of other surfactants. We then applied this approach to the crystallization of a his-tagged membrane protein, Reaction Center from Rhodobacter sphaeroides, performed 2400 crystallization trials, and showed that this approach can increase the range of crystal-producing conditions, the success rate at a given condition, the rate of nucleation, and the quality of the crystal formed.

59 BASIC BIOLOGICAL SCIENCES↗

Autonomous plug and play electric vehicle charging scenarios including reactive power provision: a probabilistic load flow analysis

Electric vehicle (EV) charging can have various impacts on low‐voltage distribution systems, along with increasing the uncertainty of network load levels. One method for capturing the statistical uncertainty is probabilistic load flow (PLF). A primary concern of such an approach is determining the correlation between the input variables. Since data are limited, a 1 min resolution bottom‐up time‐variant load model, capturing the changing voltage dependencies of the load, is used for modelling household electrical demand to provide pseudo‐meter data for the three‐phase PLF analysis of a residential distribution network. The correlation between the household and EV charging loads are implicitly taken into account by modelling the EV plug‐in and departure times with the corresponding occupancy model. Two autonomous plug‐and‐play charging scenarios are compared with a standard charging arrangement at both unity and 0.95 capacitive power factors. Four different PLF input correlation scenarios, varying from fully correlated to fully independent, are considered. The proposed charging scenarios and reactive power provision reduce the likelihood of system voltage violations introduced by EVs. The PLF results are verified against those from the initial time‐series analysis providing valuable insight into the uncertainty introduced by EVs and the correlation between household and EV loads.

Melhorn, Alexander C.↗

Study on plasma parameters and dust charging in an electrostatically plugged multicusp plasma device

The effect of the electrostatic confinement potential on the charging of dust grains and its relationship with the plasma parameters has been studied in an electrostatically plugged multicusp dusty plasma device. Electrostatic plugging is implemented by biasing the electrically isolated magnetic multicusp channel walls. The experimental results show that voltage applied to the channel walls can be a controlling parameter for dust charging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A small porous-plug burner for studies of combustion chemistry and soot formation

We have developed and built a small porous-plug burner based on the original McKenna burner design. The new burner generates a laminar premixed flat flame for use in studies of combustion chemistry and soot formation. The size is particularly relevant for space-constrained, synchrotron-based X-ray diagnostics. In this paper, we present details of the design, construction, operation, and supporting infrastructure for this burner, including engineering attributes that enable its small size. We also present data for charactering the flames produced by this burner. These data include temperature profiles for three premixed sooting ethylene/air flames (equivalence ratios of 1.5, 1.8, and 2.1); temperatures were recorded using direct one-dimensional coherent Raman imaging. We include calculated temperature profiles, and, for one of these ethylene/air flames, we show the carbon and hydrogen content of heavy hydrocarbon species measured using an aerosol mass spectrometer coupled with vacuum ultraviolet photoionization (VUV-AMS), and soot-volume-fraction measurements obtained using laserinduced incandescence (LII). In addition, we provide calculated mole-fraction profiles of selected gas-phase species and characteristic profiles for seven mass peaks from AMS measurements. Using these experimental and calculated results, we discuss the differences between standard McKenna burners and the new miniature porous-plug burner introduced here.

47 OTHER INSTRUMENTATION↗

Standard Modular Architecture for Consumer End Plug and Play Interfaces

The growth in load and generation sources at the edge of the grid is driving the innovation in power electronic (PE) grid interfaces at the consumer end to improve the grid resiliency, reliability, security, and cost of the future infrastructure. Novel PE technologies are key enablers for the future grid infrastructure to handle the issues that arise because of the projected growth. This paper introduces a novel fundamental building block (FBB) architecture with plug-and play features. An example framework that enables co-ordination of multiple FBBs hierarchically to provide various grid functions is also presented. The FBBs are designed to be equipped with advanced features like online health monitoring, embedded intelligence, and decision-making capability for enhancing the metrics of consumer end plug and play interfaces. The paper elaborates on the proposed architecture and the developed framework i.e., the controls, communication, protection, and the corresponding timing requirements for the building blocks. The architecture and the framework have been validated through simulations and the communication framework has been validated with a control hardware in the loop platform.

Chinthavali, Madhu Sudhan↗

SU-F-J-94: Development of a Plug-in Based Image Analysis Tool for Integration Into Treatment Planning

Purpose: To extend the functionality of a commercial treatment planning system (TPS) to support (i) direct use of quantitative image-based metrics within treatment plan optimization and (ii) evaluation of dose-functional volume relationships to assist in functional image adaptive radiotherapy. Methods: A script was written that interfaces with a commercial TPS via an Application Programming Interface (API). The script executes a program that performs dose-functional volume analyses. Written in C#, the script reads the dose grid and correlates it with image data on a voxel-by-voxel basis through API extensions that can access registration transforms. A user interface was designed through WinForms to input parameters and display results. To test the performance of this program, image- and dose-based metrics computed from perfusion SPECT images aligned to the treatment planning CT were generated, validated, and compared. Results: The integration of image analysis information was successfully implemented as a plug-in to a commercial TPS. Perfusion SPECT images were used to validate the calculation and display of image-based metrics as well as dose-intensity metrics and histograms for defined structures on the treatment planning CT. Various biological dose correction models, custom image-based metrics, dose-intensity computations, and dose-intensity histograms were applied to analyze the image-dose profile. Conclusion: It is possible to add image analysis features to commercial TPSs through custom scripting applications. A tool was developed to enable the evaluation of image-intensity-based metrics in the context of functional targeting and avoidance. In addition to providing dose-intensity metrics and histograms that can be easily extracted from a plan database and correlated with outcomes, the system can also be extended to a plug-in optimization system, which can directly use the computed metrics for optimization of post-treatment tumor or normal tissue response models. Supported by NIH - P01 - CA059827.

60 APPLIED LIFE SCIENCES↗

An LLVM Instrumentation Plug-in for Score-P

Reducing application runtime, scaling parallel applications to higher numbers of processes/threads, and porting applications to new hardware architectures are tasks necessary in the software development process. Therefore, developers have to investigate and understand application runtime behavior. Tools such as monitoring infrastructures that capture performance relevant data during application execution assist in this task. The measured data forms the basis for identifying bottlenecks and optimizing the code.Monitoring infrastructures need mechanisms to record application activities in order to conduct measurements. Automatic instrumentation of the source code is the preferred method in most application scenarios. We introduce a plug-in for the LLVM infrastructure that enables automatic source code instrumentation at compile-time. In contrast to available instrumentation mechanisms in LLVM/Clang, our plug-in can selectively include/exclude individual application functions. This enables developers to fine-tune the measurement to the required level of detail while avoiding large runtime overheads due to excessive instrumentation.

Tschüter, Ronny↗

High Performance Computing Productivity Study - Evaluation of Parallel Tools Platform (PTP) Eclipse Plug-In

This report is a DARPA funded Work For Others (WFO) evaluation of the Parallel Tools Platform (PTP) version 5.0.3 (Released October 18, 2011). PTP is currently being developed and supported as an open source product managed by Project Lead Greg Watson and team at IBM plus several other contributors. The tool has been in development since 2005 with a goal of providing an infrastructure for the integration of high performance computing tools. Basic functionality such as source code editing, compiling, launching, and debugging, plus more advanced features including performance monitoring and deployment have been bundled into an Eclipse Integrated Development Environment (IDE) plug-in to give parallel application programmers the features and improved productivity gained from using a common, well established development platform. The evaluation encompasses the basic aspects of using PTP, beginning with the installation and configuration of the plug-in, followed by code development and debugging. Each aspect is evaluated based on the expectations of my experience as an Eclipse user and is presented in the following format: • Feature description • User Experience • Evaluation The feature description is based on the provided documentation for PTP and the ‘generic’ expectations of what the feature should provide. The user experience reveals the actual use and exercise of the feature – specifically in the context and perspective of the evaluation platform provided by Lawrence Livermore National Laboratory. The evaluation of each feature includes the overall outcome of the user experience, along with the expectations that were not met, met, or exceeded along with any issues that were encountered.

97 MATHEMATICS AND COMPUTING↗

Electromagnetic Analysis For The Design Of ITER Diagnostic Port Plugs During Plasma Disruptions

ITER diagnostic port plugs perform many functions including structural support of diagnostic systems under high electromagnetic loads while allowing for diagnostic access to plasma. The design of diagnotic equatorial port plugs (EPP) are largely driven by electromagnetic loads and associate response of EPP structure during plasma disruptions and VDEs. This paper summarizes results of transient electromagnetic analysis using Opera 3d in support of the design activities for ITER diagnostic EPP. A complete distribution of disruption loads on the Diagnostic First Walls (DFWs). Diagnostic Shield Modules (DSMs) and the EPP structure, as well as impact on the system design integration due to electrical contact among various EPP structural components are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

City of Las Vegas Plug-in Hybrid Electric Vehicle Demonstration Program

The City of Las Vegas was awarded Department of Energy (DOE) project funding in 2009, for the City of Las Vegas Plug-in Hybrid Electric Vehicle Demonstration Program. This project allowed the City of Las Vegas to purchase electric and plug-in hybrid electric vehicles and associated electric vehicle charging infrastructure. The City anticipated the electric vehicles having lower overall operating costs and emissions similar to traditional and hybrid vehicles.

33 ADVANCED PROPULSION SYSTEMS↗