Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Revisiting plasma hysteresis with an electronically compensated Langmuir probe

The measurement of electron temperature in plasma by Langmuir probes, using ramped bias voltage, is seriously affected by the capacitive current of capacitance of the cable between the probe tip and data acquisition system. In earlier works a dummy cable was used to balance the capacitive currents. Under these conditions, the measured capacitive current was kept less than a few mA. Such probes are suitable for measurements in plasma where measured ion saturation current is of the order of hundreds of mA. This paper reports that controlled balancing of capacitive current can be minimized to less than 20 {mu}A, allowing plasma measurements to be done with ion saturation current of the order of hundreds of {mu}A. The electron temperature measurement made by using probe compensation technique becomes independent of sweep frequency. A correction of {<=}45% is observed in measured electron temperature values when compared with uncompensated probe. This also enhances accuracy in the measurement of fluctuation in electron temperature as {delta}T{sub pk-pk} changes by {approx}30%. The developed technique with swept rate {<=}100 kHz is found accurate enough to measure both the electron temperature and its fluctuating counterpart. This shows its usefulness in measuring accurately the temperature fluctuations because of electron temperature gradient in large volume plasma device plasma with frequency ordering {<=}50 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of radially movable multichannel Reynolds stress probe system for a cylindrical laboratory plasma

A new radially movable multichannel azimuthal probe system has been developed for measuring azimuthal and radial profiles of electrostatic Reynolds stress (RS) per mass density of microscale fluctuations for a cylindrical laboratory plasma. The system is composed of 16 probe units arranged azimuthally. Each probe unit has six electrodes to simultaneously measure azimuthal and radial electric fields for obtaining RS. The advantage of the system is that each probe unit is radially movable to measure azimuthal RS profiles at arbitrary radial locations as well as two-dimensional structures of fluctuations. The first result from temporal observation of fluctuation azimuthal profile presents that a low-frequency fluctuation (1-2 kHz) synchronizes oscillating Reynolds stress. In addition, radial scanning of the probe system simultaneously demonstrates two-dimensional patterns of mode structure and nonlinear forces with frequency f= 1.5 kHz and azimuthal mode number m= 1.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integration of uncooled scraper elements and its diagnostics into Wendelstein 7-X

The modular stellarator Wendelstein 7-X in Greifswald (Germany) successfully started operation in 2015 with short pulse limiter plasmas. In 2017, the next operation phase (OP) OP1.2 will start once 10 uncooled test divertor units (TDU) with graphite armor will be installed. The TDUs allow for plasma pulses of 10 s with 8 MW heating. OP2, allowing for steady state operation, is planned for 2020 after the TDUs will be replaced by 10 water cooled CFC armored divertors. Due to the development of plasma currents like bootstrap currents in long pulse plasmas in OP2, the plasma could hit the edge of the divertor targets which has a reduced cooling capacity compared to the central part of the target tiles. To prevent overloading of these edges, a so-called scraper element can be positioned in front of the divertor, intersecting those strike lines that would otherwise hit the divertor edges. As a result, these edges are protected but as a drawback the pumping efficiency of neutrals is also reduced. As a test an uncooled scraper element with graphite tiles will be placed in two out of ten half modules in OP1.2. A decision to install ten water cooled scraper elements for OP2 is pending on the results of this test in OP1.2. To monitor the impact of the scraper element on the plasma, Langmuir probes are integrated in the plasma facing surface, and a neutral gas manometer measures the neutral density directly behind the plasma facing surface. Moreover, IR and VIS cameras observe the plasma facing surface and thermocouples monitor the temperatures of the graphite tiles and underlying support structure. This paper describes the integration of the scraper element and its diagnostics in Wendelstein 7-X.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma gradient effets on doubel-probe measurements in the magnetosphere

The effects on double-probe electric field measurements induced by electron density and temperature gradients are investigated. We show that on some occasions such gradients may lead to marked spurious electric fields if the probes are assumed to lie at the same probe potential with repect to the plasma. The use of a proper bias current will decrease the magnitude of such an error. When the probes are near the plasma potential, the magnitude of these error signals, delta Epsilon, can vary as delta Epsilon approx. T(sub e)(Delta n(sub e)/n(sub e)) + 0.5 Delta T(sub e), where T(sub e) is the electron temperature, Delta n(sub e)/ n(sub e) the relative electron density variation between the two sensors, and Delta T(sub e) the electron temperature difference between the two sensors. This not only implies that the error signals will increase linearly with the density variations but also that such signatures grow with Delta T(sub e) i.e., such effects are 10 times larger in a 10-eV plasma than in a 1-eV plasma. This type of error is independent of the probe separation distance provided the gradient scale length is much larger than the distance. The largest errors occur when the probes are near to the plasma potential. During the crossing of a small structure (e.g, a double layer) the error signal appears as a bipolar signature. Our analysis shows that errors in double-probe measurements caused by plasma gradients are not significant at large scale (much greater than 1 km) plasma boundaries, and may only be important in cases where small-scale (less than 1 km), internal gradient structures exist. Bias currents tailored for each plasma parameter regime (i.e., variable bias current) would improve the double-probe response to gradient effects considerably.

Laakso, Harri↗

First application of a digital mirror Langmuir probe for real-time plasma diagnosis

We report for the first time, a digital Mirror Langmuir Probe (MLP) has successfully sampled plasma temperature, ion saturation current, and floating potential together on a single probe tip in real time in a radio-frequency driven helicon linear plasma device. This is accomplished by feedback control of the bias sweep to ensure a good fit to I–V characteristics with a high frequency, high power digital amplifier, and field-programmable gate array controller. Measurements taken by the MLP were validated by a low speed I–V characteristic manually collected during static plasma conditions. Plasma fluctuations, induced by varying the axial magnetic field($\widetilde{f}$ = 10 Hz), were also successfully monitored with the MLP. Further refinement of the digital MLP pushes it toward a turn-key system that minimizes the time to deployment and lessens the learning curve, positioning the digital MLP as a capable diagnostic for the study of low radio-frequency plasma physics. These demonstrations bolster confidence in fielding such digital MLP diagnostics in magnetic confinement experiments with high spatial and adequate temporal resolution, such as edge plasma, scrape-off layer, and divertor probes.

47 OTHER INSTRUMENTATION↗

Interacting dust grains in complex plasmas: Ion wake formation and the electric potential

Dust grains have been used as minimally invasive probes to determine plasma parameters including the plasma density, temperature, and electric field in a plasma discharge. However, the dust grains in a plasma generate local potential disturbances due to the collection of charge and the subsequent electrostatic interactions between the dust and charged plasma particles. Dust grains in close proximity to one another exhibit interesting non-reciprocal interactions and self-organize into structures such as one-dimensional filamentary chains, two-dimensional “zigzags,” and three-dimensional helices, among others. The formation of these structures suggests that although the dust grains may be less invasive than traditional plasma probes, the disturbance to the local plasma environment introduced by dust grains is non-trivial. Commonly used analytic forms of the electric potential describing complex plasmas have failed to resolve the near-dust region, and as a result are insufficient to provide insight about the formation of complex dust structures. Here, we use an N-body simulation to compute the electric potential from ion densities near various dust grain configurations. We provide an alternative description to the standard analytic model for the electric potential of dust and ion wakes based on a Gaussian shaped cloud of ions. The electric potential obtained from simulations is used to identify minimum energy configurations for two and three dust grains. It is further demonstrated that the minimum potential region identified for N dust grains and their associated ion wakes does not predict the minimum-energy configuration of N + 1 dust grains.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Langmuir Probe Distortions and Probe Compensation in an Inductively Coupled Plasma

In many RF discharges, Langmuir probe measurements are usually made against a background of sinusoidal (and not so sinusoidal) fluctuations in the plasma parameters such as the plasma potential (Vp), the electron number density (ne), and the electron temperature (Te). The compensation of sinusoidal fluctuations in Vp has been extensively studied and is relatively well understood. Less attention has been paid to the possible distortions introduced by small fluctuations in plasma density and/or plasma temperature, which may arise in the sheath and pre-sheath regions of RF discharges. Here, we present the results of a model simulation of probe characteristics subject to fluctuations in both Vp and ne. The modeling of probe distortion due to possible fluctuations in Te is less straightforward. A comparison is presented of calculations with experimental measurements using a compensated and uncompensated Langmuir probe in an inductively coupled GEC reference cell plasma, operating on Ar and Ar/CF4 mixtures. The plasma parameters determined from the compensated probe characteristics are compared to previous measurements of others made in similar discharges, and to our own measurements of the average electron density derived from electrical impedance measurements.

Ji, J. S.↗

Hyper-Velocity Nanoparticle Plasma Jet as Fast Probe for Runaway Electrons in Tokamak Disruptions

The large energy focalized deposition of the runaway electron (RE) beam on the first wall can potentially yield to destructive effects on the reactor vessel during the explosive instability of a major disruption in a large tokamak (e.g. RE beam estimation is multi-MA of ~10 MeV energy in ITER.) Impurity injection is seen as an effective way to suppress REs after thermal quench (TQ). Injected material in solid state is advantageous, but it must be in small size grain form, with large surface-to-mass ratio to facilitate its rapid ablation within plasma. However, the results using shattered pellet injection (SPI), a technique aiming to satisfy these condition, indicated that the relatively unexplored RE evolution phases and RE beam-plasma interaction are far from being properly diagnosed and fully understood. We proposed the idea to probe REs with a pulsed power hyper-velocity large-mass nanoparticle plasma jet (NPPJ). NPPJ provides a high specific surface area and swift injection to core, hence fast increase of three basic parameters: 1) the electron density ne (bound and free through ionization, if the cold post-TQ plasma has a still high enough T e ), 2) the effective charge (Z eff ) which rises both the dynamical friction force and plasma resistivity, and, finally, 3) the value of the (Dreicer and critical) threshold E-field above which electrons are accelerated and become REs. But the fast transient phenomena of RE ”seed” creation, RE ”avalanche” multiplication, and RE beam formation and interaction with the background plasma all take place dominantly in the core plasma, where the induction E-field has its maximum. Thus, the RE probe success requires a rapid (1 - 2 ms) injection of sufficient mass able to penetrate through the strong toroidal magnetic field (2 - 5 T) over a long distance (~1 - 2 m) with a large assimilation fraction in the core plasma. As a RE probe, NPPJ is a unique combination of fast response with trigger-to-delivery time of few milliseconds, large mass-velocity (>75 mg at several km/s) and deep injection into post-TQ central plasma. The Objectives of this Category #1 project (concept development) were as follows: 1: We investigated the essential basic physics aspects of creating a plasma with ~10 15 to 10 16 cm -3 boron nitride (BN) NP density suited for a pulsed power plasma gun acceleration to several km/s. We concluded that, for RE NPPJ probe, BN (diameter Ø10 to 100 nm NPs) are in all respects usable. 2: We advanced solutions to get BN NPPJ by adapting FAR-TECH’s technology for C 60 NPPJ. 3: We developed self-consistent models for RE current density j RE (R; t) evolution in the TQ aftermath, with fast and simultaneous increase of n e (R; t) and Z eff (R; t) > 1 upon the specific injection of C 60 (i.e. C ions) and BN NP (i.e. B and N ions), respectively. We showed that prompt post-TQ injection and high velocity are of essence in RE probe diagnostics and suppression. 4: We used the in-house HEM-2D code to simulate the C$_{60}^{q+}$ NPPJ transverse penetration through tokamak-level B-field (BT ~2 to 5 T) and distance (~1 to 2m), with fragmentation of C$_{60}^{q+}$ and developed the algorithm for BN Q+ NPPJ ablative sublimation of BN Q+ NP by the collisions with post-TQ plasma electrons. HEM-2D results indicated that fragmenting C$_{60}^{1+}$ NPPJ penetrates up to ~60 cm in 100 us when injecting at 1.6 ms after TQ and gradually released C 2 fragments and C ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A comparison of emissive probe techniques for electric potential measurements in a complex plasma

The major emissive probe techniques are compared to better understand the floating potential of an electron emitting surface in a plasma. An overview of the separation point technique, floating point technique, and inflection point in the limit of zero emission technique is given, addressing how each method works as well as the theoretical basis and limitations of each. It is shown that while the floating point method is the most popular, it is expected to yield a value {approx}1.5T{sub e}/e below the plasma potential due to a virtual cathode forming around the probe. The theoretical predictions were checked with experiments performed in a 2 kW annular Hall thruster plasma (n{sub e} {approx} 10{sup 9}-10{sup 10} cm{sup -3}and T{sub e} {approx} 10-50 eV). The authors find that the floating point method gives a value around 2T{sub e}/e below the inflection point method, which is shown to be a more accurate emissive probe technique than other techniques used in this work for measurements of the plasma potential.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multidirectional plasma flow measurement by Gundestrup Probe in scrape-off layer of ADITYA tokamak

Multidirectional plasma flow measurements by using Gundestrup Probe in the scrape-off layer of ADITYA tokamak are presented. The ADITYA Gundestrup Probe-head consists of eight plates arranged around the ceramic rod and three pins normal to side plates. Plates are used to measure both parallel and perpendicular flows simultaneously and pins are used to measure plasma density and floating potential. A comparison of direct perpendicular flow measurement and by two other plates of Gundestrup Probe is presented. Possible causes of perpendicular flows are identified and compared with the measured flows. It is observed that the mechanism of the parallel flow and the perpendicular flow is different only at high parallel Mach number. A puff of the working gas is used to study its effect on the perpendicular flows and its reversal with the gas puff is observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Note: On the measurement of plasma potential fluctuations using emissive probes

In this Note, it is pointed out that emissive probes cannot be used to directly and reliably measure plasma potential fluctuations. An experimentally validated model demonstrates indeed that the floating potential fluctuations of an emissive probe which floats at the mean plasma potential depend not only on the plasma potential fluctuations but also on electron density and temperature fluctuations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-stimulated photodetachment of electrons from the negatively charged dielectric substrates

The photon-stimulated emission of bulk electrons has been extensively studied for various types of materials, while the photodetachment of surplus surface electrons has not been fully explored. The photodetachment barrier energy is commonly defined by the surface electron affinity of material, which is typically less than the work function and more pronounced for non-conducting substrates and in environments with a continuous flux of electrons to the surface, such as in gas discharge plasmas. Herein, it is experimentally shown that the photodetachment yield of surplus electrons created by plasma-induced charging of non-conductive surfaces of dielectric materials depends on the initial surface charge density and do not correlate with the tabulated affinity values of these materials under gas discharge charging conditions. In cocnclusion, this result obtained using laser-stimulated photodetachment for fused silica, boron nitride, and alumina, is critically important for the understanding of charging and discharging dynamics, secondary electron emission, and photo emission effects affecting plasma–wall interactions relevant to surface and capacitively coupled discharges, dusty plasmas, electrostatic probe diagnostics, and applications for plasma processing of materials, plasma propulsion, and gas breakdown.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detection of an electron beam in a high density plasma via an electrostatic probe

An electron beam is detected by a 1D floating potential probe array in a relatively high density (10e12 - 10e13 cm-3) and low temperature (~ 5 eV) plasma of the Magnetic Reconnection Experiment (MRX). Clear perturbations in the floating potential profile by the electron beam are observed. Based on the floating potential profile and a current balance equation to the probe array tips, the effective width of the electron beam is determined, from which we determine the radial and toroidal beam current density profiles. After the profile of the electron beam is specified from the measured beam current, we demonstrate the consistency of the current balance equation and the location of the perturbation is also in agreement with field line mapping. No significant broadening of the electron beam is observed after the beam propagates for tens of centimeters through the high density plasma. These results prove that the field line mapping is, in principle, possible in high density plasmas.

field line mapping↗