Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Development and Characterization of Cementitious Waste Forms for Immobilization of Granular Activated Carbon, Silver Mordenite, and HEPA Filter Media Solid Secondary Waste

Solid secondary waste materials expected to be generated during Hanford Waste Treatment and Immobilization Plant (WTP) operations were characterized (using representative materials) with respect to their ability to retain technetium-99 (Tc), iodine-129 (I), and mercury (Hg) as input to future updates to the Integrated Disposal Facility (IDF) performance assessments (PAs). The waste materials included granular activated carbon (GAC), silver mordenite (AgM), and high-efficiency particulate air (HEPA) filter media; all are used for removal of contaminants and radionuclides from the gaseous effluent treatment systems within the WTP. It is expected that the GAC and AgM will be mixed into a cementitious waste form in which the GAC and AgM particles will be blended/stabilized into the cementitious material. It is also expected that the HEPA filter media will be compacted and placed in a container that is then backfilled with a grout to macroencapsulate the medium. Here we report Kds for all waste materials of interest, examine the physical properties of grout specimens containing the waste materials, and provide solid-state characterization information to further understand the interaction of the waste materials with the encapsulating grout. The Kds are used in PA calculations that estimate contaminant release from the disposal site. Monolithic test specimens were prepared with the GAC and AgM mixed in either a Cast Stone grout formulation (8 weight percent [wt%] ordinary Portland cement [OPC], 45 wt% fly ash [FA], 47 wt% blast furnace slag [BFS]) or a Hanford grout mix 5 (HGM-5) formulation (25 wt% OPC, 75 wt% FA). As the specimens were being prepared, the fluid grout mixes were characterized for processing properties including flowability, set time, and the presence of free liquids during curing. After curing, compressive strengths of the waste forms were measured; the compressive strengths were above 2000 psi, easily exceeding the 500 psi minimum requirement. The cured waste forms were also characterized for their density, porosity, hydraulic conductivity, and water characteristic curve—all properties needed in PA calculations of radionuclide release from the waste forms in the IDF. Finally, EPA Method 1315 leach tests were conducted on the GAC and AgM waste materials encapsulated in the Cast Stone and HGM-5 grouts to determine the rate of release of contaminants from the waste forms. Effective diffusivities are provided, which can be used in future PA analyses of the disposal of these solid secondary waste materials.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Peak Demand Impacts From Electricity Efficiency Programs

Quantification of the costs and benefits of electricity efficiency programs have focused largely on the economic value of annual energy reductions. State public utility commissions PUCs and utilities are increasingly interested in assessing peak demand impacts of these programs. The U.S. Energy Information Administration defines peak demand as "The maximum load during a specified period of time." In practice, utilities and grid operators use a wide range of definitions for peak demand. With increasing need for a more flexible and resilient electricity system, and changing costs for generation, utilities and other efficiency program administrators must take into account all characteristics of efficiency programs — including peak demand reduction — to ensure a reliable system at the most affordable cost. In this study, Berkeley Lab explored a new metric, the program administrator (PA) cost of saving peak demand (PA CSPD). We collected data on costs, energy savings and peak demand savings for electricity efficiency programs for 36 investor-owned utilities and other PAs in nine states (Arizona, Arkansas, California, Colorado, Illinois, Massachusetts, Maryland, New York and Texas) for 2014 to 2017. While some utilities report demand reductions for their electricity efficiency programs, there has been little sustained effort in the United States to gather peak demand reduction data or benchmark the cost of achieving peak demand impacts. As a first of its kind analysis, we developed a framework for analyzing peak demand savings across utilities and states and begin to quantify the cost of saving peak demand.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Inventory Data Package for the Hanford Site Composite Analysis

The disposed inventory estimate is perhaps the most important component of the composite analysis (CA), as it directly affects the future radiological impacts following site closure. The goal is to estimate radionuclide inventory from site inception to closure. Because of the inclusive nature of a CA, all relevant contaminants are identified and initially considered. Then, subsets of contaminants appropriate for quantitative analysis are selected. Reducing the number of radionuclides for inclusion in the quantitative analysis helps focus budget and resources on simulating only those radionuclides that are likely to contribute to the total dose to the receptor above a threshold value. Inventory is reported within the geographical boundary of the Hanford Site 200 Areas and includes contributing sources on the Central Plateau. The inventory covers the radiological inventories of historical discharges and residuals that have the potential to release after closure. The reported inventory is focused on the source terms needed for transport modeling and the evaluation of risk associated with the ground water pathway. Risk from the air pathway was considered. Inventories of sites with approved performance assessments (PAs) will be integrated using their release curves directly with vadose zone transport modeling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Groundwater and Intruder Radionuclide Screening

Solid Waste Management (SWM) operates the E-Area Low-Level Waste Facility (ELLWF) where low level on-site and off-site solid waste streams are buried. The facility has been in operation since late 1994 and is currently projected to remain in operation until 2065. This facility can accommodate a broad range of waste forms resulting from the six different types of disposal unit options (i.e., varying degrees of engineered barriers → trenches to concrete vaults). This facility is currently operating under a Performance Assessment (PA) issued back in 2008, along with several subsequent supporting Special Analyses (SA). The Savannah River National Laboratory (SRNL) developed the prior PAs and SAs and has been tasked to update the facility’s PA. For operating the E-Area facility, a Waste Inventory Tracking System (e.g., WITS) is actively employed by waste generators where every radionuclide entering the facility (to be buried in one of its many disposal units) must be either directly or indirectly accounted for. Since there is a large number of radionuclides in existence (>3,000), the International Commission on Radiological Protection (ICRP-107) has provided guidance on the subset of radionuclides requiring further assessment in landfills such as the E-Area LLWF. The ICRP-107 publication provides critical radiological information on 1,252 radionuclides of 97 elements. This database is the critical starting point for developing a consistent inventory limit system. The explicit measurement and tracking of all radionuclides are not necessary when process knowledge, burial history, and radiological aspects are factored into conservative groundwater and intruder screening processes. Across the DOE complex these screening processes have been historically performed using the methodology suggested by the National Council on Radiation Protection and Measurements (NCRP) as presented in their original report (NCRP 1984) and then refined in a later report (NCRP 1996). In the recommended screening models employed within this report the traditional NCRP models are updated to better handle progeny and better reflect the known characteristics of E-Area. This improved screening process is referred to as the “NCRP-like” method. Various upgrades to the traditional NCRP methodology have been used by others (e.g., NRC funded effort by Kennedy and Strenge 1992). The more detailed models by Kennedy and Strenge (1992) were considered in this effort and are compared to the results from the more traditional NCRP-like models. The groundwater and inadvertent intruder screening analyses presented in this report start with this 1,252 radionuclide list and reduces it down to more manageable lists that are applicable to the various disposal unit types contained within E-Area. In order to reduce this starting list, some level of exposure risk must be considered acceptable. Historically, a dose (or concentration level) has been compared with a screening criterion set to 1% of a performance measure (e.g., a beta-gamma dose not to exceed the 4 mrem/yr beta-gamma performance measure x 0.01 = 0.04 mrem/yr). Thus, if a radionuclide produced a bounding or screening-level dose (or concentrations) less than the screening criterion, it could be safely removed from further consideration. Several tiers of screening and bounding level analyses have been considered in this report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Groundwater and Intruder Radionuclide Screening

Solid Waste Management (SWM) operates the E-Area Low-Level Waste Facility (ELLWF) where low level on-site and off-site solid waste streams are buried. The facility has been in operation since late 1994 and is currently projected to remain in operation until 2065. This facility can accommodate a broad range of waste forms resulting from the six different types of disposal unit options (i.e., varying degrees of engineered barriers → trenches to concrete vaults). This facility is currently operating under a Performance Assessment (PA) issued back in 2008, along with several subsequent supporting Special Analyses (SA). The Savannah River National Laboratory (SRNL) developed the prior PAs and SAs and has been tasked to update the facility’s PA. For operating the E-Area facility, a Waste Inventory Tracking System (e.g., WITS) is actively employed by waste generators where every radionuclide entering the facility (to be buried in one of its many disposal units1) must be either directly or indirectly accounted for. Since there is a large number of radionuclides in existence (>3,000), the International Commission on Radiological Protection (ICRP-107) has provided guidance on the subset of radionuclides requiring further assessment in landfills such as the E-Area LLWF. The ICRP-107 publication provides critical radiological information on 1,252 radionuclides of 97 elements. This database is the critical starting point for developing a consistent inventory limit system. The explicit measurement and tracking of all 1,252 ICRP-107 radionuclides can be reduced when process knowledge, burial history, and radiological aspects are factored into conservative groundwater and intruder screening processes. Across the DOE complex these screening processes have been historically performed using the methodology suggested by the National Council on Radiation Protection and Measurements (NCRP) as presented in their original report (NCRP 1984) and then refined in a later report (NCRP 1996). In the recommended screening models employed within this report the traditional NCRP models are updated to better handle progeny and better reflect the known characteristics of E-Area. This improved screening process is referred to as the “NCRP-like” method. Various upgrades to the traditional NCRP methodology have been used by others (e.g., NRC funded effort by Kennedy and Strenge 1992). The more detailed models by Kennedy and Strenge (1992) were considered in this effort and are compared to the results from the more traditional NCRP-like models. The groundwater and inadvertent intruder screening analyses presented in this report start with this 1,252 radionuclide list and reduces it down to more manageable lists that are applicable to the various disposal unit types contained within E-Area. In order to reduce this starting list, some level of exposure risk must be considered acceptable. Historically, a dose (or concentration level) has been compared with a screening criterion set to 1% of a performance measure (e.g., a betagamma dose not to exceed the 4 mrem/yr beta-gamma performance measure x 0.01 = 0.04 mrem/yr). Thus, if a radionuclide produced a bounding or screening-level dose (or concentrations) less than the screening criterion, it could be safely removed from further consideration. Several tiers of screening and bounding level analyses have been considered in this report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vadose Zone Model for B-3A/B Pond for Composite Analysis

The objectives of the vadose modeling for the updated Hanford Site composite analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates for the plateau to river (P2R) model, version 8.3 (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed “dry” in solid waste burial grounds or other means. The following 16 radionuclides were selected for this modeling effort; carbon-14 (C-14), chlorine-36 (Cl-36), tritium (H-3), iodine-129 (I-129), neptunium-237 (Np-237), rhenium-187 (Re-187), strontium-90 (Sr-90), technetium-99 (Tc-99), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), uranium-238 (U-238), radium-226 (Ra-226), and thorium-230 (Th-230). The simulation time starts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070. The parallel version of the Subsurface Transport Over Multiple Phases (STOMP) simulator officially named the exascale Subsurface Transport Over Multiple Phases (eSTOMP), is used to simulate flow and transport for the vadose models. The documentation for the STOMP code is comprehensive. The theoretical and numerical approaches applied in the STOMP code are documented in a published theory guide (PNNL-12030, STOMP Subsurface Transport Over Multiple Phases Version 2.0 Theory Guide). The code has undergone a rigorous verification procedure against analytical solutions, laboratory-scale experiments, and field-scale demonstrations. The application guide (PNNL-11216, STOMP Subsurface Transport Over Multiple Phases Application Guide) provides instructive examples in the application of the code to classical groundwater problems. The user’s guide (PNNL-15782, STOMP: Subsurface Transport Over Multiple Phases Version 4.0: User’s Guide) describes the general use, input file formatting, compilation, and execution of the code. The primary output of the vadose zone modeling is radionuclide transfer rates to the groundwater for input into the P2R model. The rates will be summed over the 100 by 100 m P2R grid cells that fall within the vadose zone model source domain. The Hanford Site Central Plateau was subdivided into 26 individual vadose zone models, with 13 in the 200 East Area and 13 in the 200 West Area. Waste sites that have a completed performance assessment (PA) or past-leak analysis were not included as sources of radionuclides. Instead the vadose zone to groundwater transfer rates of the Environmental Restoration Disposal Facility, Integrated Disposal Facility, US Ecology, and Waste Management Area C (WMA C) PAs and the past-leak analysis for WMA C were used as direct input to the P2R model. Each of the vadose zone models is documented in separate environmental calculation files (ECFs). This ECF describes the B-3A/B Ponds model. The scope of this ECF is to document the development and results of the B-3 A/B Ponds vadose zone model. CP-63515, Model Package Report: Central Plateau Vadose Zone Models, describes the approach, assumptions, process of determining the number of models required and domain of each model, input data, and processing common to all the models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vadose Zone Model for SALDS for Composite Analysis

The objectives of the vadose modeling for the updated Hanford Site composite analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates for the plateau to river (P2R) model, version 8.3 (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed “dry” in solid waste burial grounds or other means. The following 16 radionuclides were selected for this modeling effort: carbon-14 (C-14), chlorine-36 (Cl-36), tritium (H-3), iodine-129 (I-129), neptunium-237 (Np-237), rhenium-187 (Re-187), strontium-90 (Sr-90), technetium-99 (Tc-99), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), uranium-238 (U-238), radium-226 (Ra-226), and thorium-230 (Th-230). The simulation time starts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070. The parallel version of the Subsurface Transport Over Multiple Phases (STOMP1) simulator, officially named the exascale Subsurface Transport Over Multiple Phases (eSTOMP) is used to simulate flow and transport for the vadose models. The documentation for the STOMP code is comprehensive. The theoretical and numerical approaches applied in the STOMP code are documented in a published theory guide (PNNL-12030, STOMP Subsurface Transport Over Multiple Phases Version 2.0 Theory Guide). The code has undergone a rigorous verification procedure against analytical solutions, laboratory-scale experiments, and field-scale demonstrations. The application guide (PNNL-11216, STOMP Subsurface Transport Over Multiple Phases Application Guide) provides instructive examples in the application of the code to classical groundwater problems. The user’s guide (PNNL-15782, STOMP: Subsurface Transport Over Multiple Phases Version 4.0: User’s Guide) describes the general use, input file formatting, compilation, and execution of the code. The primary output of the vadose zone modeling is radionuclide transfer rates to the groundwater for input into the P2R model. The rates will be summed over the 100 by 100 m P2R grid cells that fall within the vadose zone model source domain. The Hanford Site Central Plateau was subdivided into 26 individual vadose zone models, with 13 in the 200 East Area and 13 in the 200 West Area. Waste sites that have a completed performance assessment (PA) or past-leak analysis were not included as sources of radionuclides. Instead the vadose zone to groundwater transfer rates of the Environmental Restoration Disposal Facility, Integrated Disposal Facility, US Ecology, and Waste Management Area C (WMA C) PAs and the past-leak analysis for WMA C were used as direct input to the P2R model. Each of the vadose zone models is documented in separate environmental calculation files (ECFs). This ECF describes the State-Approved Land Disposal Site (SALDS) model. The scope of this ECF is to document the development and results of the SALDS vadose zone model. CP-63515, Model Package Report: Central Plateau Vadose Zone Models, describes the approach, assumptions, process of determining the number of models required and domain of each model, input data, and processing common to all the models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nevada National Security Site 2019 Waste Management Monitoring Report Area 3 and Area 5 Radioactive Waste Management Sites

Environmental monitoring data are collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) within the Nevada National Security Site (NNSS). This report summarizes the 2019 environmental data to provide an overall evaluation of RWMS performance and to support environmental compliance and performance assessment (PA) activities. Some of these data (e.g., radiation exposure, air, and groundwater) are presented in other reports (Mission Support and Test Services, LLC 2019, 2020a, 2020b). Direct radiation monitoring data indicate exposure levels at the Area 3 and Area 5 RWMSs are within the range of background levels measured at the NNSS. Slightly elevated exposure levels outside the Area 3 RWMS are attributed to nearby historical aboveground nuclear weapons tests. Air monitoring data at the Area 3 and Area 5 RWMSs show that tritium concentrations in water vapor and americium and plutonium concentrations in air particles are below Derived Concentration Standards for these radionuclides. Groundwater monitoring data indicate the groundwater in the uppermost aquifer beneath the Area 5 RWMS is not impacted by RWMS operations. Results of groundwater analysis from wells around the Area 5 RWMS are below established investigation levels. Leachate samples collected from the leachate collection systems at the Area 5 mixed low-level waste disposal unit are below established contaminant regulatory limits. During 2019, precipitation at the Area 3 RWMS was 77 percent above average, and precipitation at the Area 5 RWMS was 69 percent above average. Water balance measurements indicate that evapotranspiration from the vegetated weighing lysimeter at the Area 5 RWMS dries the soil and prevents downward percolation of precipitation more effectively than evaporation as measured from the bare-soil weighing lysimeter. Vadose zone monitoring in the Area 3 and Area 5 RWMS soil covers shows no evidence of precipitation percolating through the covers to the waste. Moisture from precipitation did not percolate below 120 centimeters (3.9 feet [ft]) in the vegetated final cover on the U-3ax/bl disposal unit at the Area 3 RWMS during 2019. There was no drainage through 2.4 meters (8 ft) of soil as indicated from the Area 3 drainage lysimeters that received only natural precipitation. At the Area 3 RWMS, which received three times the natural precipitation, 57 percent of the applied precipitation and irrigation drained from the bare-soil drainage lysimeter. All 2019 monitoring data indicate that the Area 3 and Area 5 RWMSs are performing within expectations of the model and parameter assumptions for the facilities’ PAs.

2019↗

Geochemical data package for performance assessment calculations related to the Savannah River Site

The Savannah River Site (SRS) disposes of low-level radioactive waste (LLW) and stabilizes high-level radioactive waste (HLW) tanks in the subsurface environment. Calculations used to establish the radiological limits of these facilities are referred to as Performance Assessments (PAs), Special Analyses (SAs), and Composite Analyses (CAs). The purpose of this document is to revise the existing geochemical data package used for these calculations (Kaplan, 2016). This work builds on earlier compilations of geochemical data, referred to a geochemical data packages (Kaplan, 2007; Kaplan, 2010; Kaplan, 2016; McDowell-Boyer et al., 2000). This work is being conducted as part of the on-going maintenance program of the SRS PA programs that periodically updates calculations and data packages when new information becomes available.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MIT Capstone Project Assignment 1 - Existing System Design

“FPU in 5”: The National Nuclear Security Administration (NNSA) and upper management at Lawrence Livermore National Lab (LLNL) have informally set a long-term goal of decreasing the development cycle of new systems to five years or less. The driver is to be able to respond to emerging situations which require new capabilities more quickly. There are numerous approaches to solve the problem, and any single improvement is likely insufficient. Our capstone project focuses on modernizing the design development processes, production development processes, and communication between design agencies (DAs) and production agencies (PAs) to decrease the timeline from conceptual study to first production unit. Our project’s system problem statement (SPS) is below: TO decrease the time from conceptual study to first production unit BY centralizing design development, production development, and information exchange USING digital engineering techniques.

42 ENGINEERING↗

(U) MIT Capstone Project (Final Report)

This capstone project focuses on modernizing the design development processes, production development processes, and communication between design agencies (DAs) and production agencies (PAs) to decrease the timeline from conceptual study to first production unit. To focus the scope, the researchers looked only at interactions between the DA, Lawrence Livermore National Lab (LLNL), and the PA, Kansas City National Security Campus (KCNSC). The project’s system problem statement (SPS) is: TO decrease the time from conceptual study to first production unit BY reducing the DA to-PA engineering interface complexity USING digital engineering software that centralizes product definition and information exchange protocols.

42 ENGINEERING↗

E-Area Low-Level Waste Facility Multitiered Groundwater and Intruder Radionuclide Screening

Solid Waste Management (SWM) operates the E-Area Low-Level Waste Facility (ELLWF) where low level on-site and off-site solid waste streams are buried. The facility has been in operation since late 1994 and is currently projected to remain in operation until 2065. This facility can accommodate a broad range of waste forms resulting from the six different types of disposal unit (DU) options (i.e., varying degrees of engineered barriers → trenches to concrete vaults). This facility is currently operating under a Performance Assessment (PA) issued back in 2008 (WSRC 2008), along with several subsequent supporting Special Analyses (SAs). The Savannah River National Laboratory (SRNL) developed the prior PAs and SAs and was tasked to update the facility’s upcoming PA, most likely to be issued during FY2023. For operating the E-Area facility, a Consolidated Waste Tracking System (CWTS) is actively employed by waste generators where every radionuclide entering the facility, to be buried in one of its many DUs1, must be either directly or indirectly tracked. Since there are many radionuclides in existence (>3,000), the International Commission on Radiological Protection (ICRP), specially ICRP Publication 107, has provided guidance on the subset of radionuclides requiring further assessment in landfills such as the ELLWF. The ICRP 107 publication provides critical radiological information on 1,252 radionuclides consisting of 97 elements. This database, along with the current dose coefficients that have been developed for these radionuclides in DOE-STD-1196-2011 (DOE 2011), is the critical starting point for developing a consistent inventory limit system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Materials and Manufacturing Technologies Nondestructive Examination Efforts at Idaho National Laboratory: Report of FY-24 Efforts

This report details FY-24 nondestructive examination (NDE) efforts at Idaho National Laboratory (INL) in support of the Advanced Materials and Manufacturing Technologies (AMMT) program. While the goal of this endeavor is to develop a multi-modal, multi-length scale workflow for nondestructive characterization of advanced manufactured (AM) nuclear reactor components, substantial development remains until this is a reality. In support of this effort X-ray computed tomography (XCT), X-ray diffraction (XRD), neutron computed tomography (nCT), neutron diffraction, lock-in thermography (LIT), multi-point lock-in thermography (MLIT), and positron annihilation spectroscopy (PAS) were all used on AM specimens to examine defects such as voids, porosity, and residual stress. In addition to summarizing the results of these NDE applications, recommendations for integrating these into a more comprehensive undertaking to promote NDE of engineering-scale components are also included.

36 MATERIALS SCIENCE↗

Sorption of Metals and Radionuclides in Cementitious Leachate Impacted Sediments from the Savannah River Site

Performance assessments (PAs) are calculations used to establish the risk posed by radioactive waste disposal facilities in the Savannah River Site (SRS). The distribution coefficient (Kd; solid/liquid concentration ratio; Csolid/liquid) is one of the key geochemical parameters used in the PA to provide a measure of how strongly the dissolved contaminants bind to solid phases; the greater the Kd value, the greater the tendency to bind to the solids. The overall purpose of this study was to measure this key parameter for several constituents of concern in the cementitious leachate impacted SRS sediment environments. Particular attention was directed at quantifying the influence of cementitious leachate from various stages of cement aging on the sorption of radioactive waste and heavy metals on SRS sediments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ADVANCED WAVEFORM SIMULATION FOR SEISMIC MONITORING EVENTS

We conduct a detailed test of a recently developed technique, CAPloc, in recovering source parameters from a few stations against results from a large broadband network. The method uses a library of 1D Green’s functions which are broken into segments and matched to waveform observations with adjustable timing shifts. These shifts can be established by calibration against a distribution of well-located earthquake and assembled in tomographic images for predicting various phase-delays. Synthetics generated from 2D cross-sections through these models indicates that 1D synthetic waveforms are sufficient in modeling but simply shifted in time for hard-rock sites. This simplification allows the source inversion for both mechanism and location to be easily obtained by grid search. We test one-station mechanisms for 160 events against the array for both PAS and GSC which have data since 1960. While one station solutions work well (about 90%), joint solutions produce more reliable and defensible results. Inverting for both mechanism and location also works well except for certain difficult paths that cross deep basins or propagate along mountain ridges.

58 GEOSCIENCES↗

Nevada Test Site 2007 Waste Management Monitoring Report Area 3 and Area 5 Radioactive Waste Management Sites

Environmental monitoring data were collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site. These data are associated with radiation exposure, air, groundwater, meteorology, vadose zone, subsidence, and biota. This report summarizes the 2007 environmental data to provide an overall evaluation of RWMS performance and to support environmental compliance and performance assessment (PA) activities. Some of these data (e.g., radiation exposure, air, and groundwater) are presented in other reports (National Security Technologies, LLC, 2007a; 2008; Warren and Grossman, 2008). Direct radiation monitoring data indicate exposure levels at the RWMSs are at background levels. Air monitoring data at the Area 3 and Area 5 RWMSs indicate that tritium concentrations are slightly above background levels. A single gamma spectroscopy measurement for cesium was slightly above the minimum detectable concentration, and concentrations of americium and plutonium are only slightly above detection limits at the Area 3 RWMS. The measured levels of radionuclides in air particulates are below derived concentration guides for these radionuclides. Radon flux from waste covers is well below regulatory limits. Groundwater monitoring data indicate that the groundwater in the uppermost aquifer beneath the Area 5 RWMS is not impacted by facility operations. The 136.8 millimeters (mm) (5.39 inches [in.]) of precipitation at the Area 3 RWMS during 2007 is 13 percent below the average of 158.1 mm (6.22 in.), and the 123.8 mm (4.87 in.) of precipitation at the Area 5 RWMS during 2007 is 6 percent below the average of 130.7 mm (5.15 in.). Soil-gas tritium monitoring at borehole GCD-05U continues to show slow subsurface migration consistent with previous results. Water balance measurements indicate that evapotranspiration from the vegetated weighing lysimeter dries the soil and prevents downward movement percolation of precipitation more effectively than evaporation from the bare-soil weighing lysimeter. Data from the automated vadose zone monitoring system for the operational waste pit covers show that evaporation continues to slowly remove soil moisture that came from the heavy precipitation in the fall of 2004 and the spring of 2005. The vegetated final mono-layer cover on the U-3ax/bl disposal unit at the Area 3 RWMS effectively removes moisture from the cover by evapotranspiration. During 2007, there was no drainage through 2.4 meters (8 feet) of soil from the Area 3 drainage lysimeters that received only natural precipitation or were vegetated but water drained from the bare-soil Area 3 drainage lysimeter that received 3 times natural precipitation. Elevated tritium levels in plants and animals sampled from the Area 3 and Area 5 RWMSs show tritium uptake by the biota, but the low levels of other radionuclides do not suggest that there has been intrusion into the waste. All 2007 monitoring data indicate that the Area 3 and Area 5 RWMSs are performing within expectations of the model and parameter assumptions for the facility PAs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RANGE AND DISTRIBUTION OF TECHNETIUM KD VALUES IN THE SRS SUBSURFACE ENVIRONMENT

Performance assessments (PAs) are risk calculations used to estimate the amount of low-level radioactive waste that can be disposed at DOE sites. Distribution coefficients (K{sub d} values) are input parameters used in PA calculations to provide a measure of radionuclide sorption to sediment; the greater the K{sub d} value, the greater the sorption and the slower the estimated movement of the radionuclide through sediment. Understanding and quantifying K{sub d} value variability is important for estimating the uncertainty of PA calculations. Without this information, it is necessary to make overly conservative estimates about the possible limits of K{sub d} values, which in turn may increase disposal costs. Finally, technetium is commonly found to be amongst the radionuclides posing potential risk at waste disposal locations because it is believed to be highly mobile in its anionic form (pertechnetate, TcO{sub 4}{sup -}), it exists in relatively high concentrations in SRS waste, and it has a long half-life (213,000 years). The objectives of this laboratory study were to determine under SRS environmental conditions: (1) whether and to what extent TcO{sub 4}{sup -} sorbs to sediments, (2) the range of Tc K{sub d} values, (3) the distribution (normal or log-normal) of Tc K{sub d} values, and (4) how strongly Tc sorbs to SRS sediments through desorption experiments. Objective 3, to identify the Tc K{sub d} distribution is important because it provides a statistical description that influences stochastic modeling of estimated risk. The approach taken was to collect 26 sediments from a non-radioactive containing sediment core collected from E-Area, measure Tc K{sub d} values and then perform statistical analysis to describe the measured Tc K{sub d} values. The mean K{sub d} value was 3.4 {+-} 0.5 mL/g and ranged from -2.9 to 11.2 mL/g. The data did not have a Normal distribution (as defined by the Shapiro-Wilk's Statistic) and had a 95-percentile range of 2.4 to 4.4 mL/g. The E-Area subsurface is subdivided into three hydrostratigraphic layers: Upper Vadose Zone (11 to 30 ft depth), Lower Vadose Zone (30 to 51 ft depth), and aquifer (51 to 95 ft depth). The Upper Vadose Zone generally contains more clay than the Lower Vadose Zone, and the Aquifer tends to be made up of mostly sand layers with clay strata. The mean K{sub d} values of each of these zones did not differ significantly and the K{sub d} values from each zone were not from the Normal distribution. The ranges of values were greatest in the Upper Vadose Zone and least in the Lower Vadose Zone. Previous Best Estimate Tc K{sub d} values for Sandy Sediment and Clayey Sediment were 0.1 and 0.2 mL/g, respectively (Kaplan 2007a). A more thorough review indicates that the Best Estimates for Sandy Sediment is 0.1 mL/g and for Clayey Sediment is 0.8 mL/g (Kaplan 2007b). This current dataset greatly increases the number of Tc K{sub d} values measured with SRS sediments, but perhaps more importantly, provides a better estimate for E-Area sediments, and provides a measure of Tc K{sub d} distributions. Based on this dataset, the best overall Tc K{sub d} value for E-Area is the mean, 3.4 mL/g, with a log-normal distribution between the 95 percentile values of 2.4 to 4.4 mL/g. This document version differs from the earlier version, SRNS-STI-2008-00286, in that it includes some editorial corrections. This version does not contain any technical changes or changes to the conclusions presented in the earlier version.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SALTSTONE AND RADIONUCLIDE INTERACTIONS: RADIONUCLIDE SORPTION AND DESORPTION, AND SALTSTONE REDUCTION CAPACITY

The overall objective of this study was to measure a number of key input parameters quantifying geochemical processes in the subsurface environment of the Savannah River Site's (SRS's) Saltstone Facility. For the first time, sorption (K{sub d}) values of numerous radionuclides were measured with Saltstone and Vault 2 concrete. Particular attention was directed at understanding how Tc adsorbs and desorbs from these cementitious materials with the intent to demonstrate that desorption occurs at a much slower rate than adsorption, thus permitting the use of kinetic terms instead of (or along with) the steady state K{sub d} term. Another very important parameter measured was the reduction capacity of these materials. This parameter is used to estimate the duration that the Saltstone facility remains in a reduced chemical state, a condition that maintains several otherwise mobile radionuclides in an immobile form. Key findings of this study follow. K{sub d} values for Am, Cd, Ce, Co, Cs, Hg, I, Np, Pa, Pu, Se, Sn, Tc, U, and Y for Saltstone and Vault 2 concrete were measured under oxidized and reduced conditions. Precipitation of several of the higher valence state radionuclides was observed. There was little evidence that the Vault 2 and Saltstone K{sub d} values differed from previous SRS K{sub d} values measured with reducing grout (Kaplan and Coates 2007). These values also supported a previous finding that K{sub d} values of slag-containing cementitious materials, tend to be greater for cations and about the same for anions, than regular cementitious materials without slag. Based on these new findings, it was suggested that all previous reducing concrete K{sub d} values be used in future PAs, except Np(V) and Pu(IV) K{sub d} values, which should be increased, and I values, which should be slightly decreased in all three stages of concrete aging. The reduction capacity of Saltstone, consisting of 23 wt-% blast furnace slag, was 821.8 microequivalents per gram ({micro}eq/g). This value was approximately the same value as the one measured for 100% blast furnace slag. The cause for this approximately four-fold greater reduction capacity than anticipated is not known, but may be the result of the higher pH of Saltstone (pH {approx}11) compared to blast furnace slag (pH {approx}8), the presence of reducing minerals in the fly ash used to make the Saltstone, or to the Saltstone possibly having semi-conductor properties. These reduction capacity values will result in a near four-fold increase in the estimated duration that the Saltstone facility will remain in a reduced chemical state. The implication of this result is that oxidation-state-sensitive contaminants, such as Pu, Np, and Tc, will remain for a longer duration in a much less mobile form than previously believed. The reduction capacity of vault concrete, which consisted of 10 wt-% blast furnace slag, was 240 {micro}eq/g. Essentially all Am, Cd, Ce, Co, Cs, Hg, Sr, and Y was (ad)sorbed within four hours, whereas <3% of the adsorbed metals desorbed from these solids after 90 hours of continuous leaching. In particular, desorption of Tc (under oxidizing conditions) was >10{sup 3} fold slower than (ad)sorption (under reducing conditions). An important implication of this finding is that if groundwater by-passes or short-circuits the reduction capacity of the Saltstone by flowing along a crack, the ability of the oxygenated water to promote Tc desorption is appreciably less than that predicted based on the K{sub d} value. Relatively low Tc K{sub d} values, 6 to 91 mL/g, were measured in these studies indicating that little if any of the Tc(VII) introduced into the Saltstone or Vault 2 concrete suspensions was reduced to Tc(IV). Such a reduction results in apparent K{sub d} values on the order of 10{sup 4} mL/g. As such, these Tc sorption/desorption experiments need additional investigation to fully represent Saltstone environmental conditions. It is important to understand the limits of these data. They do not provide insight into how radionuclides cured and immobilized in Saltstone will leach from the Saltstone. However they do provide insight into how radionuclides once released into porewater will interact with Saltstone or vault concrete. The use of these site-specific data would greatly improve the pedigree of the input data for the Saltstone performance assessment. Additionally, these studies provided important guidance and technical justification for the conceptual geochemical model to be used in the Saltstone performance assessment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗