Sensitivity of the GAPS experiment to low-energy cosmic-ray antiprotons

The General Antiparticle Spectrometer (GAPS) is an upcoming balloon mission to measure low-energy cosmic-ray antinuclei during at least three ~35-day Antarctic flights. With its large geometric acceptance and novel exotic atom-based particle identification, GAPS will detect ~500 cosmic antiprotons per flight and produce a precision cosmic antiproton spectrum in the kinetic energy range of ~0.07–0.21 GeV/n at the top of the atmosphere. With these high statistics extending to lower energies than any previous experiment, and with complementary sources of experimental uncertainty compared to traditional magnetic spectrometers, the GAPS antiproton measurement will be sensitive to dark matter, primordial black holes, and cosmic ray propagation. The antiproton measurement will also validate the GAPS antinucleus identification technique for the antideuteron and antihelium rare-event searches. Finally, this analysis demonstrates the GAPS sensitivity to cosmic-ray antiprotons using a full instrument simulation and event reconstruction, and including solar and atmospheric effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TPCpp-10M: Simulated proton-proton collisions in a time projection chamber for AI foundation models

Scientific foundation models hold great promise for advancing nuclear and particle physics by improving analysis precision and accelerating discovery. Yet, progress in this field is often limited by the lack of openly available large scale datasets, as well as standardized evaluation tasks and metrics. Furthermore, the specialized knowledge and software typically required to process particle physics data pose significant barriers to interdisciplinary collaboration with the broader machine learning community. This work introduces a large, openly accessible dataset of 10 million simulated proton-proton collisions, designed to support self-supervised training of foundation models. To facilitate ease of use, the dataset is provided in a common NumPy format. In addition, it includes 70,000 labeled examples spanning three well defined downstream tasks: track finding, particle identification, and noise tagging, to enable systematic evaluation of the foundation model's adaptability. The simulated data are generated using the Pythia Monte Carlo event generator at a center of mass energy of $\sqrt{s}$ = 200 GeV and processed with Geant4 to include realistic detector conditions and signal emulation in the sPHENIX Time Projection Chamber at the Relativistic Heavy Ion Collider, located at Brookhaven National Laboratory. This dataset resource establishes a common ground for interdisciplinary research, enabling machine learning scientists and physicists alike to explore scaling behaviors, assess transferability, and accelerate progress toward foundation models in nuclear and high energy physics. The complete simulation and reconstruction chain is reproducible with the sPHENIX software stack. All data and code locations are provided under Data Accessibility.

Data Analysis, Statistics and Probability (physics↗

A scaler-based data acquisition system for measuring parity-violating asymmetry in deep inelastic scattering

An experiment that measured the parity violating asymmetries in deep inelastic scattering was completed at the Thomas Jefferson National Accelerator Facility in experimental Hall A. From these asymmetries, a combination of the quark weak axial charge could be extracted with a factor of five improvement in precision over world data. To achieve this, asymmetries at the 10^-4 level needed to be measured at event rates up to 500 kHz and the high pion background typical to deep inelastic scattering experiments needed to be rejected efficiently. A specialized data acquisition (DAQ) system with intrinsic particle identification (PID) was successfully developed and used: The pion contamination in the electron samples was controlled at the order of 2 × 10^-4 or below with an electron efficiency of higher than 91% throughout the production period of the experiment, the systematic uncertainty in the measured asymmetry due to DAQ deadtime was below 0.2%, and the statistical quality of the asymmetry measurement agreed with the Gaussian distribution to over five orders of magnitudes. The DAQ system is presented here with an emphasis on its design scheme, the achieved PID performance, deadtime effect and the capability of measuring small asymmetries.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An algorithm for charge-integration, pulse-shape discrimination and estimation of neutron/photon misclassification in organic scintillators

Organic scintillators are frequently used for measurements that require sensitivity to both photons and fast neutrons because of their pulse shape discrimination capabilities. In these measurement scenarios, particle identification is commonly handled using the charge-integration pulse shape discrimination method. This method works particularly well for high-energy depositions, but is prone to misclassification for relatively low-energy depositions. A novel algorithm has been developed for automatically performing charge-integration pulse shape discrimination in a consistent and repeatable manner. The algorithm is able to estimate the photon and neutron misclassification corresponding to the calculated discrimination parameters, and is capable of doing so using only the information measured by a single organic scintillator. This paper describes the algorithm and assesses its performance by comparing algorithm-estimated misclassification to values computed via a more traditional time-of-flight estimation. A single data set was processed using four different low-energy thresholds: 40, 60, 90, and 120 keVee. Overall, the results compared well between the two methods; in most cases, the algorithm-estimated values fell within the uncertainties of the TOF-estimated values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Test beam studies of silicon timing for use in calorimetry

The high luminosity upgrade of the Large Hadron Collider (HL-LHC) at CERN is expected to provide instantaneous luminosities of 5 X 10 34 cm –2 s –1 . The high luminosities expected at the HL-LHC will be accompanied by a factor of 5 to 10 more pileup compared with LHC conditions in 2015, causing general confusion for particle identification and event reconstruction. Precision timing allows to extend calorimetric measurements into such a high density environment by subtracting the energy deposits from pileup interactions. Calorimeters employing silicon as the active component have recently become a popular choice for the HL-LHC and future collider experiments which face very high radiation environments. In this article, we present studies of basic calorimetric and precision timing measurements using a prototype composed of tungsten absorber and silicon sensor as the active medium. Lastly, we show that for the bulk of electromagnetic showers induced by electrons in the range of 20 GeV to 30 GeV, we can achieve time resolutions better than 25 ps per single pad sensor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Position-sensitive detection of ultracold neutrons with an imaging camera and its implications to spectroscopy

Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15μm has been achieved, which is equivalent to a UCN energy resolution below 2 pico-electron-volts through the relation δE=m 0 gδx. Here, the symbols δE, δx, m 0 and g are the energy resolution, the spatial resolution, the neutron rest mass and the gravitational acceleration, respectively. A multilayer surface convertor described previously is used to capture UCNs and then emits visible light for CCD imaging. Particle identification and noise rejection are discussed through the use of light intensity profile analysis. As a result, this method allows different types of UCN spectroscopy and other applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combination of two Gas Electron Multipliers and a Micromegas as gain elements for a time projection chamber

We measured the properties of a novel combination of two Gas Electron Multipliers with a Micromegas for use as amplification devices in high-rate gaseous time projection chambers. The goal of this design is to minimize the buildup of space charge in the drift volume of such detectors in order to eliminate the standard gating grid and its resultant dead time, while preserving good tracking and particle identification performance. To characterize this micro-pattern gas detector configuration, we measured the positive ion back-flow and energy resolution at various element gains and electric fields, using a variety of gases, and additionally studied crosstalk effects and discharge rates. At a gain of 2000, this configuration achieves an ion back-flow below 0.4% and an energy resolution better than σ / E = 12 % for 55 Fe X-rays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An innovative bolometric Cherenkov-light detector for a double beta decay search

Here, we present here an innovative cryogenic light detector capable to measure a few tens of eV signal thanks to the amplification assisted by the Neganov-Luke effect. The thermal signal boost in the presence of an electric field allows us to improve the signal-to-noise ratio reaching a baseline noise of around 20 eV. This device - coupled to an enriched 130TeO 2 bolometer (435 g) - registered 160 eV Cherenkov light signal induced by 2615 keV 208 Tl with a signal to noise ratio about 6:1. Since α particles emitted in decays of natural radionuclides do not produce the Cherenkov radiation, we were then able to achieve an efficient α/γ separation in the region of interest for neutrinoless double beta decay of 130 Te (Q-value is 2527 keV). Specifically, a rejection factor of 99.9% for α particles was obtained with a 98.3% acceptance of β/γ events. The achieved α rejection efficiency is required to reduce the dominant α background in the follow-up of the CUORE experiment (CUPID), a ton-scale bolometric search with particle identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A prototype for SANDD: A highly-segmented pulse-shape-sensitive plastic scintillator detector incorporating silicon photomultiplier arrays

We report the first clear observation of neutron/gamma-ray pulse-shape sensitivity of a fully-instrumented 8 × 8 array of plastic scintillator segments coupled to two 5 cm × 5 cm 64-channel SiPM arrays as part of a study of the key metrics of a prototype antineutrino detector module designed for directional sensitivity. SANDD (a Segmented AntiNeutrino Directional Detector) will eventually comprise a central module of 64 elongated segments of 6 Li-doped pulse-shape-sensitive scintillator rods, each with a square cross section of 5.4 mm × 5.4 mm, surrounded by larger cross section bars of the same material. The most important metrics with the potential to impact the performance of the central module of SANDD are neutron and gammaray pulse-shape sensitivity using silicon photomultipliers (SiPMs), particle identification via scintillator rod multiplicity, and energy and position resolution. As a first step, we constructed a prototype detector to investigate the performance of a central SANDD-like module using two 64-channel SiPM arrays and rods of undoped pulse-shape-sensitive plastic scintillator.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A functional form for liquid scintillator pulse shapes

Digitization of detector signals enables analysis of the original waveform to extract timing, particle identification, and energy deposition information. Here we present the use of analytical functions based on sigmoids to model and fit such pulse shapes from liquid organic scintillators, though the method should also be applicable to other detector systems. Neutron and gamma interactions in NE213 detectors were digitized from the phototube anode and fit using a sigmoid-based function. The acuity of the fit in extracting timing information and performing neutron-gamma pulse-shape discrimination are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charged particle track reconstruction with SπRIT Time Projection Chamber

In this work, we present a software framework, SπRITROOT, which is capable of track reconstruction and analysis of heavy-ion collision events recorded with the SRIT time projection chamber. The track-fitting toolkit GENFIT and the vertex reconstruction toolkit RAVE are applied to a box-type detector system. A pattern recognition algorithm which performs helix track finding and handles overlapping pulses is described. The performance of the software is investigated using experimental data obtained at the Radioactive Isotope Beam Facility (RIBF) at RIKEN. This work focuses on data from 132 Sn + 124 Sn collision events with beam energy of 270 AMeV. Particle identification is established using < dE/dx >and magnetic rigidity, with pions, hydrogen isotopes, and helium isotopes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BoxScore - A real-time beam-diagnosis program for the CAEN digitizer x730 series

BoxScore is a real-time beam diagnosis and monitoring program for the CAEN x730 series digitizer, developed for the ATLAS in-flight system at Argonne National Laboratory. The CAEN x730 series digitizer, with built-in Digital Pulse Processing for the Pulse-Height-Analysis, digitizes the input signal in real-time and processes it using a trapezoidal filter. BoxScore reads the digitizer’s buffer directly, builds and saves events to local files, plots histograms for particle identification, and outputs the rates of selected isotopes every second. Implementation of BoxScore has shortened the time needed for in-flight beam-tuning and has potential applications for other nuclear physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and simulated performance of calorimetry systems for the ECCE detector at the electron ion collider

Here, we describe the design and performance the calorimeter systems used in the ECCE detector to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapidity range from -3.7 to 3.8 and two hadronic calorimeters covering a combined range of -1.1<η<3.8. Key calorimeter performances which include energy and position resolutions, reconstruction efficiency, and particle identification will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measured and projected beam backgrounds in the Belle II experiment at the SuperKEKB collider

The Belle II experiment at the SuperKEKB electron–positron collider aims to collect an unprecedented data set of 50 ab -1 to study CP -violation in the B -meson system and to search for Physics beyond the Standard Model. SuperKEKB is already the world’s highest-luminosity collider. In order to collect the planned data set within approximately one decade, the target is to reach a peak luminosity of 6 x 10 35 cm −2 s −1 by further increasing the beam currents and reducing the beam size at the interaction point by squeezing the betatron function down to β $^*_y$ = 0.3 mm. To ensure detector longevity and maintain good reconstruction performance, beam backgrounds must remain well controlled. We report on current background rates in Belle II and compare these against simulation. We find that a number of recent refinements have significantly improved the background simulation accuracy. Finally, we estimate the safety margins going forward. We predict that backgrounds should remain high but acceptable until a luminosity of at least 2.8 x 10 35 cm −2 s −1 is reached for β $^*_y$ = 0.6 mm. At this point, the most vulnerable Belle II detectors, the Time-of-Propagation (TOP) particle identification system and the Central Drift Chamber (CDC), have predicted background hit rates from single-beam and luminosity backgrounds that add up to approximately half of the maximum acceptable rates.

Detector background↗

Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a precise-timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and a Micromegas amplifying structure, targeting a time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a time resolution below σ = 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B 4 C), is pursued. Results from prototypes equipped with DLC and B 4 C photocathodes exhibited a time resolution of σ ≈ 32 ps and σ ≈ 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance measurements of the electromagnetic calorimeter and readout electronics system for the DarkQuest experiment

Here, this paper presents performance measurements of a new readout electronics system based on silicon photomultipliers for the PHENIX electromagnetic calorimeter. Installation of the lead-scintillator Shashlik style calorimeter into the SeaQuest/SpinQuest spectrometer has been proposed to broaden the experiment’s dark sector search program, an upgrade known as DarkQuest. The calorimeter and electronics system were subjected to testing and calibration at the Fermilab Test Beam Facility. Detailed studies of the energy response and resolution, as well as particle identification capabilities, were performed. The background rate in the actual experimental environment was also examined. The system is found to be well-suited for a dark sector search program on the Fermilab 120 GeV proton beamline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation studies for beam commissioning at FRIB Advanced Rare Isotope Separator

The Facility for Rare Isotope Beams (FRIB) includes a powerful superconducting driver accelerator and an Advanced Rare Isotope Separator (ARIS). The ARIS collects and purifies the rare isotope fragments of interest for experiments in nuclear physics, nuclear astrophysics, fundamental symmetries, etc. ARIS consists of a vertical pre-separator and downstream horizontal separator section (C-Bend). Each section can provide a high-resolution separation alternatively. The resolution reduction due to the emittance induced by momentum compression can be avoided by isotope separation in different dispersive planes. Beam commissioning of ARIS for the first experiments was completed and demonstrated particle identification of fragments. The beam tuning in ARIS largely relies on numerical simulations since the limited space for diagnostics. Here, we report the result of the beam trajectory correction, transverse matching, and beam-based misalignment studies at ARIS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficiency corrections for factorial moments and cumulants of overlapping sets of particles

In this note we discuss subtleties associated with the efficiency corrections for measurements of off-diagonal cumulants and factorial moments for a situation when one deals with overlapping sets of particles, such as correlations between numbers of protons and positively charged particles. In particular, we discuss the situation commonly encountered in heavy-ion experiments, where first all charges are reconstructed and then protons are selected from these charges by an additional particle identification procedure. We present the efficiency correction formulas for the case when the detection efficiencies follow a binomial distribution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗