At least 271 records · Page 15

Blood flow dynamics in heart failure

BACKGROUND: Exercise intolerance in heart failure (HF) may be due to inadequate vasodilation, augmented vasoconstriction, and/or altered muscle metabolic responses that lead to fatigue. METHODS AND RESULTS: Vascular and metabolic responses to rhythmic forearm exercise were tested in 9 HF patients and 9 control subjects (CTL) during 2 protocols designed to examine the effect of HF on the time course of oxygen delivery versus uptake (protocol 1) and on vasoconstriction during exercise with 50 mm Hg pressure about the forearm to evoke a metaboreflex (protocol 2). In protocol 1, venous lactate and H+ were greater at 4 minutes of exercise in HF versus CTL (P<0.05) despite similar blood flow and oxygen uptake responses. In protocol 2, mean arterial pressure increased similarly in each group during ischemic exercise. In CTL, forearm blood flow and vascular conductance were similar at the end of ischemic and ambient exercise. In HF, forearm blood flow and vascular conductance were reduced during ischemic exercise compared with the ambient trial. CONCLUSIONS: Intrinsic differences in skeletal muscle metabolism, not vasodilatory dynamics, must account for the augmented glycolytic metabolic responses to moderate-intensity exercise in class II and III HF. The inability to increase forearm vascular conductance during ischemic handgrip exercise, despite a normal pressor response, suggests that enhanced vasoconstriction of strenuously exercising skeletal muscle contributes to exertional fatigue in HF.

NASA Discipline Cardiopulmonary↗

Intramuscular deoxygenation during exercise in patients who have chronic anterior compartment syndrome of the leg

Currently, the definitive diagnosis of chronic compartment syndrome is based on invasive measurements of intracompartmental pressure. We measured the intramuscular pressure and the relative oxygenation in the anterior compartment of the leg in eighteen patients who were suspected of having chronic compartment syndrome as well as in ten control subjects before, during, and after exercise. Chronic compartment syndrome was considered to be present if the intramuscular pressure was at least fifteen millimeters of mercury (2.00 kilopascals) before exercise, at least thirty millimeters of mercury (4.00 kilopascals) one minute after exercise, or at least twenty millimeters of mercury (2.67 kilopascals) five minutes after exercise. Changes in relative oxygenation were measured with use of the non-invasive method of near-infrared spectroscopy. In all patients and subjects, there was rapid relative deoxygenation after the initiation of exercise, the level of oxygenation remained relatively stable during continued exercise, and there was reoxygenation to a level that exceeded the pre-exercise resting level after the cessation of exercise. During exercise, maximum relative deoxygenation in the patients who had chronic compartment syndrome (mean relative deoxygenation [and standard error], -290 +/- 39 millivolts) was significantly greater than that in the patients who did not have chronic compartment syndrome (-190 +/- 10 millivolts) and that in the control subjects (-179 +/- 14 millivolts) (p < 0.05 for both comparisons). In addition, the interval between the cessation of exercise and the recovery of the pre-exercise resting level of oxygenation was significantly longer for the patients who had chronic compartment syndrome (184 +/- 54 seconds) than for the patients who did not have chronic compartment syndrome (39 +/- 19 seconds) and the control subjects (33 +/- 10 seconds) (p < 0.05 for both comparisons).

NASA Discipline Musculoskeletal↗

Near-infrared spectroscopy for monitoring of tissue oxygenation of exercising skeletal muscle in a chronic compartment syndrome model

Variations in the levels of muscle hemoglobin and of myoglobin oxygen saturation can be detected non-invasively with near-infrared spectroscopy. This technique could be applied to the diagnosis of chronic compartment syndrome, in which invasive testing has shown increased intramuscular pressure associated with ischemia and pain during exercise. We simulated chronic compartment syndrome in ten healthy subjects (seven men and three women) by applying external compression, through a wide inflatable cuff, to increase the intramuscular pressure in the anterior compartment of the leg. The tissue oxygenation of the tibialis anterior muscle was measured with near-infrared spectroscopy during gradual inflation of the cuff to a pressure of forty millimeters of mercury (5.33 kilopascals) during fourteen minutes of cyclic isokinetic dorsiflexion and plantar flexion of the ankle. The subjects exercised with and without external compression. The data on tissue oxygenation for each subject then were normalized to a scale of 100 per cent (the baseline value, or the value at rest) to 0 per cent (the physiological minimum, or the level of oxygenation achieved by exercise to exhaustion during arterial occlusion of the lower extremity). With external compression, tissue oxygenation declined at a rate of 1.4 +/- 0.3 per cent per minute (mean and standard error) during exercise. After an initial decrease at the onset, tissue oxygenation did not decline during exercise without compression. The recovery of tissue oxygenation after exercise was twice as slow with compression (2.5 +/- 0.6 minutes) than it was without the use of compression (1.3 +/- 0.2 minutes).

NASA Discipline Musculoskeletal↗

Effect of fluid ingestion on orthostatic responses following acute exercise

Orthostatic tolerance is impaired following an acute bout of exercise. This study examined the effect of fluid ingestion following treadmill exercise in restoring the cardiovascular responses to an orthostatic stress. Five men (age, 29.6 +/- 3.4 yrs) were exposed to a graded lower body negative (LBNP) pressure protocol (0 to -50 mmHg) during euhydration without exercise (C), 20 minutes after exercise dehydration (D), 20 minutes after exercise and fluid ingestion (FI20), and 60 minutes after exercise and fluid ingestion (FI60). Fluid ingestion (mean +/- SE) consisted of water-ingestion equivalent to 50% of the body weight lost during exercise (520 +/- 15 ml). Exercise dehydration resulted in significantly higher heart rates (119 +/- 8 vs 82 +/- 7 bpm), lower systolic blood pressures (95 +/- 1.7 vs 108 +/- 2.3 mmHg), a smaller increase in leg circumference (3.7 +/- 4 vs 6.9 +/- 1.0 mm), and an attenuated increase in total peripheral resistance (2.58 +/- 1.2 vs 4.28 +/- 0.9 mmHg/L/min) at -50 mmHg LBNP compared to the C condition. Fluid ingestion (both 20 and 60), partially restored the heart rate, systolic blood pressure, and total peripheral resistance responses to LBNP, but did not influence the change in leg circumference during LBNP (4 +/- 0.3 for R20 and 2.8 +/- 0.4 mm for R60). These data illustrate the effectiveness of fluid ingestion on improving orthostatic responses following exercise, and suggest that dehydration is a contributing factor to orthostatic intolerance following exercise.

NASA Center JSC↗

Influence of simulated microgravity on the sympathetic response to exercise

Rats exposed to simulated conditions of microgravity exhibit reductions in aerobic exercise capacity that may be due to an impaired ability of the sympathetic nervous system (SNS) to mediate an increase in cardiac output and to redistribute blood flow. The purpose of this study was to quantify the sympathetic response to exercise in rats after exposure to 14 days of simulated microgravity or control conditions. To achieve this aim, rats were exposed to 14 days of head-down suspension (HDS) or cage control (CC) conditions. On day 14, norepinephrine (NE) synthesis was blocked with alpha-methyl-p-tyrosine, and the rate of NE depletion after synthesis blockade was used to estimate SNS activity in the left ventricle, spleen, and soleus muscle during treadmill exercise at 75% of maximal oxygen uptake. When compared with CC rats, the sympathetic response to exercise in HDS rats was characterized by a lower rate of NE depletion in the left ventricle (-82%) and spleen (-42%). The rate of NE depletion in the soleus muscle was 47% higher. These differences could contribute to the decrement in aerobic capacity of HDS rats by impairing their ability to augment cardiac output and to redirect blood flow to actively contracting skeletal muscle during exercise.

NASA Discipline Cardiopulmonary↗

Clinical aspects of the control of plasma volume at microgravity and during return to one gravity

Plasma volume is reduced by 10-20% within 24-48 h of exposure to simulated or actual microgravity. The clinical importance of microgravity induced hypovolemia is manifested by its relationship with orthostatic intolerance and reduced maximal oxygen uptake (VO2max) after return to one gravity (1G). Since there is no evidence to suggest that plasma volume reduction during microgravity is associated with thirst or renal dysfunctions, a diuresis induced by an immediate blood volume shift to the central circulation appears responsible for microgravity-induced hypovolemia. Since most astronauts choose to restrict their fluid intake before a space mission, absence of increased urine output during actual space flight may be explained by low central venous pressure (CVP) which accompanies dehydration. Compelling evidence suggests that prolonged reduction in CVP during exposure to microgravity reflects a "resetting" to a lower operating point, which acts to limit plasma volume expansion during attempts to increase fluid intake. In ground based and space flight experiments, successful restoration and maintenance of plasma volume prior to returning to an upright posture may depend upon development of treatments that can return CVP to its baseline IG operating point. Fluid-loading and lower body negative pressure (LBNP) have not proved completely effective in restoring plasma volume, suggesting that they may not provide the stimulus to elevate the CVP operating point. On the other hand, exercise, which can chronically increase CVP, has been effective in expanding plasma volume when combined with adequate dietary intake of fluid and electrolytes. The success of designing experiments to understand the physiological mechanisms of and development of effective counter measures for the control of plasma volume in microgravity and during return to IG will depend upon testing that can be conducted under standardized controlled baseline conditions during both ground-based and space flight investigations.

Review, Tutorial↗

Changes in aerobic power of women, ages 20-64 yr

This study quantified and compared the cross-sectional and longitudinal influence of age, self-report physical activity (SR-PA), and body composition (%fat) on the decline of maximal aerobic power (VO2peak) of women. The cross-sectional sample consisted of 409 healthy women, ages 20-64 yr. The 43 women of the longitudinal sample were from the same population and examined twice, the mean time between tests was 3.7 (+/-2.2) yr. Peak oxygen uptake was determined by indirect calorimetry during a maximal treadmill test. The zero-order correlation of -0.742 between VO2peak and %fat was significantly (P < 0.05) higher then the SR-PA (r = 0.626) and age correlations (r = -0.633). Linear regression defined the cross-sectional age-related decline in VO2peak at 0.537 ml.kg-1.min-1.yr-1. Multiple regression analysis (R = 0.851) showed that adding %fat and SR-PA and their interaction to the regression model reduced the age regression weight of -0.537, to -0.265 ml.kg-1.min-1.yr-1. Statistically controlling for time differences between tests, general linear models analysis showed that longitudinal changes in aerobic power were due to independent changes in %fat and SR-PA, confirming the cross-sectional results. These findings are consistent with men's data from the same lab showing that about 50% of the cross-sectional age-related decline in VO2peak was due to %fat and SR-PA.

Aging/physiology↗

The development of concentration gradients in a suspension of chemotactic bacteria

When a suspension of bacterial cells of the species Bacillus subtilis is placed in a chamber with its upper surface open to the atmosphere complex bioconvection patterns are observed. These arise because the cells: (1) are denser than water; and (2) usually swim upwards, so that the density of an initially uniform suspension becomes greater at the top than the bottom. When the vertical density gradient becomes large enough, an overturning instability occurs which ultimately evolves into the observed patterns. The reason that the cells swim upwards is that they are aerotactic, i.e., they swim up gradients of oxygen, and they consume oxygen. These properties are incorporated in conservation equations for the cell (N) and oxygen (C) concentrations, and these are solved in the pre-instability phase of development when N and C depend only on the vertical coordinate and time. Numerical results are obtained for both shallow- and deep-layer chambers, which are intrinsically different and require different mathematical and numerical treatments. It is found that, for both shallow and deep chambers, a thin boundary layer, densely packed with cells, forms near the surface. Beneath this layer the suspension becomes severely depleted of cells. Furthermore, in the deep chamber cases, a discontinuity in the cell concentration arises between this cell-depleted region and a cell-rich region further below, where no significant oxygen concentration gradients develop before the oxygen is fully consumed. The results obtained from the model are in good qualitative agreement with the experimental observations.

NASA Discipline Cell Biology↗

Performance and mood-state parameters during 30-day 6 degrees head-down bed rest with exercise training

The study was designed to determine if performance and mood impairments occur in bed-rested subjects, and if different exercise-training regimens modify or prevent them. Eighteen normal, healthy men were divided on the basis of age, peak oxygen uptake, and maximal isometric knee extension strength into three similar groups: no exercise (NOE), isotonic exercise (ITE), and isokinetic exercise (IKE). A 15-min battery of 10 performance tests and 8 mood and 2 sleep scales were administered daily during ambulatory control, 30 d of absolute bed rest (BR), and 4 d of ambulatory recovery. Performance test proficiency increased (p < 0.05) for all three groups during BR in 7 of 10 tests and there were no consistent significant differences between the three groups. However, during BR, the ITE group was distinguished from the other groups by a decline (p < 0.05) in the activation mood dimension and in two of its constituent scales (motivation and concentration), and by improvement (p < 0.05) in the trouble-falling-asleep and psychological-tension scales. Since few deleterious changes in performance and mood occurred in the three groups and did not exceed baseline ambulatory levels, we conclude that mood and performance did not deteriorate in response to prolonged BR and were not altered by exercise training. However, the decline in activation mood scales in the ITE group may reflect overtraining or excess total workload in this group.

NASA Center ARC↗

Effect of leg exercise training on vascular volumes during 30 days of 6 degrees head-down bed rest

Plasma and red cell volumes, body density, and water balance were measured in 19 men (32-42 yr) confined to bed rest (BR). One group (n = 5) had no exercise training (NOE), another near-maximal variable-intensity isotonic exercise for 60 min/day (ITE; n = 7), and the third near-maximal intermittent isokinetic exercise for 60 min/day (IKE; n = 7). Caloric intake was 2,678-2,840 kcal/day; mean body weight (n = 19) decreased by 0.58 +/- 0.35 (SE) kg during BR due to a negative fluid balance (diuresis) on day 1. Mean energy costs for the NOE, and IKE, and ITE regimens were 83 (3.6 +/- 0.2 ml O2.min-1.kg-1), 214 (8.9 +/- 0.5 ml.min-1.kg-1), and 446 kcal/h (18.8 +/- 1.6 ml.min-1.kg-1), respectively. Body densities within groups and mean urine volumes (1,752-1,846 ml/day) between groups were unchanged during BR. Resting changes in plasma volume (ml/kg) after BR were -1.5 +/- 2.3% (NS) in ITE, -14.7 +/- 2.8% (P less than 0.05) in NOE, and -16.8 +/- 2.9% (P less than 0.05) in IKE, and mean water balances during BR were +295, -106, and +169 ml/24 h, respectively. Changes in red cell volume followed changes in plasma volume. The significant chronic decreases in plasma volume in the IKE and NOE groups and its maintenance in the ITE group could not be accounted for by water balance or by responses of the plasma osmotic, protein, vasopressin, or aldosterone concentrations or plasma renin activity. There was close coupling between resting plasma volume and plasma protein and osmotic content.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Regulatory Physiology↗

Elevated central venous pressure: a consequence of exercise training-induced hypervolemia?

Resting blood volumes and arterial and central venous pressures (CVP) were measured in 14 men before and after exercise training to determine whether training-induced hypervolemia is accompanied by a change in total vascular capacitance. In addition, resting levels of plasma arginine vasopressin (AVP), atrial natriuretic peptide (ANP), aldosterone (Ald), and norepinephrine (NE) were measured. The same measurements were conducted in seven subjects who did not undergo exercise and acted as controls. Exercise training consisted of 10 wk of controlled cycle exercise for 30 min/day, 4 days/wk at 75-80% of maximal O2 uptake (VO2max). A training effect was verified by a 20% increase in VO2max, a resting bradycardia, and a 9% increase in blood volume. Mean arterial blood pressure was unaltered by exercise training, but resting CVP increased by 16% (P less than 0.05). The percent change in blood volume from before to after training was linearly related to the percent change in CVP (r = 0.903, P less than 0.05). As a consequence of elevations in both blood volume and CVP, the volume-to-pressure ratio was unchanged after exercise training. Plasma AVP, ANP, Ald, and NE were unaltered. Our results indicate that elevated CVP is a consequence of training-induced hypervolemia without alteration in total effective venous capacitance.

NASA Program Space Physiology and Countermeasures↗

Prediction of functional aerobic capacity without exercise testing

The purpose of this study was to develop functional aerobic capacity prediction models without using exercise tests (N-Ex) and to compare the accuracy with Astrand single-stage submaximal prediction methods. The data of 2,009 subjects (9.7% female) were randomly divided into validation (N = 1,543) and cross-validation (N = 466) samples. The validation sample was used to develop two N-Ex models to estimate VO2peak. Gender, age, body composition, and self-report activity were used to develop two N-Ex prediction models. One model estimated percent fat from skinfolds (N-Ex %fat) and the other used body mass index (N-Ex BMI) to represent body composition. The multiple correlations for the developed models were R = 0.81 (SE = 5.3 ml.kg-1.min-1) and R = 0.78 (SE = 5.6 ml.kg-1.min-1). This accuracy was confirmed when applied to the cross-validation sample. The N-Ex models were more accurate than what was obtained from VO2peak estimated from the Astrand prediction models. The SEs of the Astrand models ranged from 5.5-9.7 ml.kg-1.min-1. The N-Ex models were cross-validated on 59 men on hypertensive medication and 71 men who were found to have a positive exercise ECG. The SEs of the N-Ex models ranged from 4.6-5.4 ml.kg-1.min-1 with these subjects.(ABSTRACT TRUNCATED AT 250 WORDS).

Oxygen Consumption↗

Cardiopulmonary Resuscitation in Microgravity: Efficacy in the Swine During Parabolic Flight

INTRODUCTION: The International Space Station will need to be as capable as possible in providing Advanced Cardiac Life Support (ACLS) and cardiopulmonary resuscitation (CPR). Previous studies with manikins in parabolic microgravity (0 G) have shown that delivering CPR in microgravity is difficult. End tidal carbon dioxide (PetCO2) has been previously shown to be an effective non-invasive tool for estimating cardiac output during cardiopulmonary resuscitation. Animal models have shown that this diagnostic adjunct can be used as a predictor of survival when PetCO2 values are maintained above 25% of pre-arrest values. METHODS: Eleven anesthetized Yorkshire swine were flown in microgravity during parabolic flight. Physiologic parameters, including PetCO2, were monitored. Standard ACLS protocols were used to resuscitate these models after chemical induction of cardiac arrest. Chest compressions were administered using conventional body positioning with waist restraint and unconventional vertical-inverted body positioning. RESULTS: PetCO2 values were maintained above 25% of both 1-G and O-G pre-arrest values in the microgravity environment (33% +/- 3 and 41 +/- 3). No significant difference between 1-G CPR and O-G CPR was found in these animal models. Effective CPR was delivered in both body positions although conventional body positioning was found to be quickly fatiguing as compared with the vertical-inverted. CONCLUSIONS: Cardiopulmonary resuscitation can be effectively administered in microgravity (0 G). Validation of this model has demonstrated that PetCO2 levels were maintained above a level previously reported to be predictive of survival. The unconventional vertical-inverted position provided effective CPR and was less fatiguing as compared with the conventional body position with waist restraints.

Weightlessness↗

Development of a Test Facility for Air Revitalization Technology Evaluation

Development of new air revitalization system (ARS) technology can initially be performed in a subscale laboratory environment, but in order to advance the maturity level, the technology must be tested in an end-to-end integrated environment. The Air Revitalization Technology Evaluation Facility (ARTEF) at the NASA Johnson Space Center serves as a ground test bed for evaluating emerging ARS technologies in an environment representative of spacecraft atmospheres. At the center of the ARTEF is a hypobaric chamber which serves as a sealed atmospheric chamber for closed loop testing. A Human Metabolic Simulator (HMS) was custom-built to simulate the consumption of oxygen, and production of carbon dioxide, moisture and heat of up to eight persons. A multitude of gas analyzers and dew point sensors are used to monitor the chamber atmosphere upstream and downstream of a test article. A robust vacuum system is needed to simulate the vacuum of space. A reliable data acquisition and control system is required to connect all the subsystems together. This paper presents the capabilities of the integrated test facility and some of the issues encountered during the integration.

Lu, Sao-Dung↗

International Space Station USOS Waste and Hygiene Compartment Development

The International Space Station (ISS) currently provides human waste collection and hygiene facilities in the Russian Segment Service Module (SM) which supports a three person crew. Additional hardware is planned for the United States Operational Segment (USOS) to support expansion of the crew to six person capability. The additional hardware will be integrated in an ISS standard equipment rack structure that was planned to be installed in the Node 3 element; however, the ISS Program Office recently directed implementation of the rack, or Waste and Hygiene Compartment (WHC), into the U.S. Laboratory element to provide early operational capability. In this configuration, preserved urine from the WHC waste collection system can be processed by the Urine Processor Assembly (UPA) in either the U.S. Lab or Node 3 to recover water for crew consumption or oxygen production. The human waste collection hardware is derived from the Service Module system and is provided by RSC-Energia. This paper describes the concepts, design, and integration of the WHC waste collection hardware into the USOS including integration with U.S. Lab and Node 3 systems.

Link, Dwight E., Jr.↗

Fractional Consumption of Liquid Hydrogen and Liquid Oxygen During the Space Shuttle Program

The Space Shuttle uses the propellants, liquid hydrogen and liquid oxygen, to meet part of the propulsion requirements from ground to orbit. The Kennedy Space Center procured over 25 million kilograms of liquid hydrogen and over 250 million kilograms of liquid oxygen during the 3D-year Space Shuttle Program. Because of the cryogenic nature of the propellants, approximately 55% of the total purchased liquid hydrogen and 30% of the total purchased liquid oxygen were used in the Space Shuttle Main Engines. The balance of the propellants were vaporized during operations for various purposes. This paper dissects the total consumption of liqUid hydrogen and liqUid oxygen and determines the fraction attributable to each of the various processing and launch operations that occurred during the entire Space Shuttle Program at the Kennedy Space Center.

Partridge, Jonathan K.↗

Oxygen enrichment combustion to reduce fossil energy consumption and emissions in hot rolling steel production

The reheating furnace operation in the hot mill is natural gas- and electricity-intensive. Oxygen enrichment combustion for reheating furnaces has been proposed to curb and replace natural gas use. In this study, heat transfer in steel slabs in the combustion environment of a push-type reheating furnace was simulated using a computational fluid dynamics (CFD) model. Two oxygen enrichment methods that optimized for performance were selected— a medium oxygen enrichment (MOE) case and an oxy-fuel (OF) case. A life cycle analysis (LCA) characterized the energy and emission profiles of an integrated iron and steel manufacturing process using the two oxygen enrichment cases for the hot mill. These conditions were evaluated for energy use and carbon intensity and compared with a baseline case. Results show that with oxygen enrichment, natural gas consumption can decrease by 19.6%–26.8%, total energy consumption (natural gas and electricity) can decrease by 15.1%–20.7% in the hot mill. Emissions of greenhouse gases can decrease by 11.1%–15.2% in the two optimized cases with 14%–27% reductions in regulated criteria pollutants (nitrogen oxides, carbon monoxide, particulate matter, volatile organic compounds, black carbon, organic carbon, and volatile organic carbons). There is a tradeoff between reducing natural gas consumption and increasing electricity demand from a life cycle perspective. Although the OF case resulted in higher energy- and emissions-related benefits, the MOE case showed the more desirable heat flux uniformity, which is key to maintaining product quality. The analysis suggests that oxygen enrichment in the reheating furnace process can have a significant impact on hot mill environmental performance and become a contributing factor in transitioning to low-carbon steel manufacturing.

36 MATERIALS SCIENCE↗