Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Operational Resilience”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Adaptive cold-load pickup considerations in 2-stage microgrid unit commitment for enhancing microgrid resilience

In an extended main grid outage spanning multiple days, load shedding serves as a critical mechanism for islanded microgrids to maintain essential power and energy reserves that are indispensable for fulfilling reliability and resiliency mandates. However, using load shedding for such purposes leads to increasing occurrence of cold load pickup (CLPU) events. Here, this study presents an innovative adaptive CLPU model that introduces a method for determining and incorporating parameters related to CLPU power and energy requirements into a two-stage microgrid unit commitment (MGUC) algorithm. In contrast to the traditional fixed-CLPU-curve approach, this model calculates CLPU duration, power, and energy demands by considering outage durations and ambient temperature variations within the MGUC process. By integrating the adaptive CLPU model into the MGUC problem formulation, it allows for the optimal allocation of energy resources throughout the entire scheduling horizon to fulfill the CLPU requirements when scheduling multiple CLPU events. The performance of the enhanced MGUC algorithm considering CLPU needs is assessed using actual load and photovoltaic (PV) data. Simulation results demonstrate significant improvements in dispatch optimality evaluated by the amount of load served, customer comfort, energy storage operation, and adherence to energy schedules. These enhancements collectively contribute to reliable and resilient microgrid operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating the resilience benefits of marine energy in microgrids

Marine energy resources could promote clean energy and resilience of coastal and island microgrids, and thus, these applications are a key future market for marine energy development. To demonstrate these benefits, this paper illustrates how inclusion of wave resources into energy resilience solutions can improve overall grid efficiency and sustainability, as well as maintain electricity supply during grid outages. The paper describes a case study evaluation of the potential to add wave energy to the Moloka’i grid as Hawaii strives to meet a 100% clean energy target. The Microgrid Component Optimization for Resilience tool is used to simulate operation in off- grid conditions and size different combinations of wave, solar photovoltaic (PV), wind, storage, and fuel resources required to meet resilience objectives. This research in- vestigates how including wave resources in a microgrid contributes to reducing biofuel generation, producing a zero-greenhouse gas emission profile, and avoiding the over-sizing of PV and battery systems to accommodate periods of unavailability or high demand. Insight from this paper supports the value proposition of wave resources for future markets and informs the relationship between marine generators and microgrids or isolated grids.

Newman, Sarah F.↗

Powering Up Secure and Reliable Operations at the Port of Honolulu's Kapalama Container Terminal

The National Laboratory of the Rockies (NLR) is providing resilience planning support to the Pasha Group, the operator of Kapalama Container Terminal (KCT) at the Port of Honolulu, by exploring how distributed clean energy resources could help the terminal sustain a 36-hour outage and continue emergency operations. The Department of Energy's Energy Transitions Initiative (ETI) aims to advance self-reliant island and remote communities by promoting resilient, affordable, and sustainable clean energy resources.

25 ENERGY STORAGE↗

Threat Hunt Guide for BESS Environments

The rapid digitalization of the electric grid - driven by the integration of inverter-based resources (IBRs), battery energy storage systems (BESS), and advanced grid control platforms - has significantly enhanced grid efficiency, visibility, and flexibility. However, this evolution also introduces new cybersecurity risks, particularly through supply chain dependencies and operational blind spots at the grid edge. To address these challenges, Idaho National Laboratory (INL), through the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) Rapid Risk initiative, conducted a series of rapid risk assessment engagements with energy organizations across the United States. Drawing on lessons learned from these engagements, INL developed the following threat hunting guide for asset owners and operators (AOOs) to enhance their cybersecurity visibility within BESS and IBR systems. The guide demonstrates how to use passive network monitoring to baseline device behavior, detect adversarial activity, and investigate anomalies without disrupting operations. By implementing these practices, energy sector stakeholders can improve coordination between cybersecurity and operations teams and strengthen the resilience of distributed energy resources (DERs) within the modern power grid. Prior to implementing any network monitoring, packet capture, or threat hunting activity described in this guide, AOOs are strongly advised to review applicable governance frameworks, legal requirements, and organizational policies. This guide is intended for informational and educational purposes only. It does not replace compliance with any federal, state, or local cybersecurity mandates or industry standards. Implementation of described configurations, technologies, or analytic workflows is performed at the discretion and responsibility of the asset owner and operator.

25 - ENERGY STORAGE↗

Evaluating the resilience benefits of marine energy in microgrids

Marine energy resources could promote clean energy and resilience of coastal and island microgrids, and thus, these applications are a key future market for marine energy development. To demonstrate these benefits, this paper illustrates how inclusion of wave resources into energy resilience solutions can improve overall grid efficiency and sustainability, as well as maintain electricity supply during grid outages. The paper describes a case study evaluation of the potential to add wave energy to the Moloka'i grid as Hawaii strives to meet a 100% clean energy target. The Microgrid Component Optimization for Resilience tool is used to simulate operation in off-grid conditions and size different combinations of wave, solar photovoltaic (PV), wind, storage, and fuel resources required to meet resilience objectives. This research investigates how including wave resources in a microgrid contributes to reducing or eliminating biofuel generation, producing a zero-greenhouse gas emission profile in the latter case, and avoiding the over-sizing of PV and battery systems to accommodate periods of unavailability or high demand. Insight from this paper supports the value proposition of wave resources for future markets and informs the relationship between marine generators and microgrids or isolated grids.

16 TIDAL AND WAVE POWER↗

Distributed Wind-Hybrid Microgrids with Autonomous Controls and Forecasting

Distributed wind-hybrid microgrids have the potential to provide key resilience and economic benefits to both the customers they serve and the utility grids they are connected to. Such microgrids will likely be a key part of the grid of the future, whether connected to large utility grids or linked together in multi-microgrid systems. Through the hybridization of distributed wind and solar photovoltaics, autonomous device-level and system-level controls, battery energy storage systems with smart inverters, and forecasting, these microgrids could maintain local stability and provide grid services - all with renewable power. In the literature, these elements have been considered individually. However, they have not been combined and demonstrated at a high fidelity, which is essential to prove the concept's operation before moving to hardware-in-the-loop and physical demonstrations. In this work, we develop a high-fidelity MATLAB-Simulink model of a real distributed wind-hybrid microgrid that includes all these elements. We demonstrate the microgrid maintaining stability and production in a variety of islanded, grid-connected, and transition scenarios. This includes riding through faults and grid transitions, handling resource variability, and providing grid services. The results demonstrate, at a high fidelity, how distributed wind-hybrid microgrids can operate in an economic and resilient fashion. Finally, we provide recommendations for future research to move advanced distributed wind-hybrid microgrids toward deployment.

ancillary services↗

Models for Resilience Design Patterns

Resilience plays an important role in supercomputers by providing correct and efficient operation in case of faults, errors, and failures. Resilience design patterns offer blueprints for effectively applying resilience technologies. Prior work focused on developing initial efficiency and performance models for resilience design patterns. This paper extends it by (1) describing performance, reliability, and availability models for all structural resilience design patterns, (2) providing more detailed models that include flowcharts and state diagrams, and (3) introducing the Resilience Design Pattern Modeling (RDPM) tool that calculates and plots the performance, reliability, and availability metrics of individual patterns and pattern combinations.

Kumar, Mohit↗

Hydropower Evaluation Framework for Wildfire Resilient Microgrids

This paper presents a framework for characterizing hydropower plants based on plant and site attributes, assessing their feasibility to function within microgrids during periods of wildfire-induced outages. A set of nine metrics is developed to assign scores to hydropower plants, considering their suitability for forming wildfire-resilient microgrids, their capability to operate within such microgrids, and their simulated performance during wildfire events. A comprehensive database is constructed, comparing hydropower plants according to their suitability and capability metrics. To evaluate the performance score of a specific hydropower plant, namely the Hills Creek plant situated in a wildfire-prone region of Oregon, a case study is conducted, simulating a wildfire scenario. The results of steady-state and dynamic simulations demonstrate that the Hills Creek hydropower plant can effectively provide crucial microgrid services and power nearby communities during a prolonged wildfire-related outages.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Case Study: Applying the Idaho National Laboratory Resilience Framework to St. Mary’s, Alaska

The Idaho National Laboratory (INL) resilience framework has been developed to broadly apply to EEDS so that all elements of systems that contain distributed wind can be part of the resilience evaluation. The users or audience for this framework can include any stakeholders associated with the EEDS. Not all electrical energy systems have the same stakeholders; customers, owners, and operators are generally present but have different interests. Considering the broad electrical grid, customers, regulators, investors, utility planners, engineers, and operators each have an interest in system resilience driven from different motivating factors. This document focuses on the planning stage of the framework. In this document, each step is explained briefly before demonstrating its application to the St. Mary’s-Mt. Village system. The framework can be used for many types of resilience planning. It can be used to evaluate current overall resilience, or the resilience of certain subsystems. It can be used to explore existing resilience weak points and propose mitigations. It can also be used to evaluate the resilience benefits of a new investment. We use the latter application for this case study. Although the wind turbine in St. Mary’s has already been installed, the resilience benefits that the turbine provided were not well defined. It was installed with the main objective to generate electric power from a renewable resource in an effort to reduce the local dependency on fuel oil as the sole source of electric power generation, which is a resilience goal on its own, but there are other ways in which the turbine can add resilience to the system, as well as scenarios of interest to analyze how resilient the wind turbine itself is against different hazards. In this case study, we analyze the operation of the St. Mary’s power system both with the wind installed and without the wind installed during different resilience hazards of interest. This allows us to compare the performance with wind and without wind and to quantify the resilience benefits provided by wind. Our MIRACL partners at PNNL will then take the resilience benefits and assign value to the resilience provided by wind based on costs and costs avoided in the different scenarios.

17 WIND ENERGY↗

Current Practices in Distribution Utility Resilience Planning for Wildfires

This report is part of a series of hazard-focused case studies examining common practices in electric utility resilience planning. We use standard terminology defining resilience as the ability to anticipate, withstand, absorb, and recover from hazards that cause long duration outages. We distinguish between reliability and resilience using IEEE 1366-2022, which defines major events as "an event that exceeds reasonable design and/or operational limits of the electric power system." Resilience planning is focused on major event days, and reliability planning is focused on non-major event days. Utility resilience plans are assessed according to common resilience components identified in existing resilience frameworks. The focus of this report is on wildfires. Standalone reports focusing on severe storms (including hurricanes and non-winter storms) and winter storms have been published in parallel with this report. This report can be used as a starting point for understanding potential investment prioritization processes and investment options. This report is intended to improve utility resilience planning by supporting constructive dialogue among utilities, regulators, and other stakeholders.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Current Practices in Distribution Utility Resilience Planning for Hurricanes and Non-Winter Storms

This report is part of a series of hazard-focused case studies examining common practices in electric utility resilience planning. We use standard terminology defining resilience as the ability to anticipate, withstand, absorb, and recover from hazards that cause long duration outages. We distinguish between reliability and resilience using IEEE 1366-2022, which defines "major events" as "an event that exceeds reasonable design and/or operational limits of the electric power system." Resilience planning is focused on "major event days" and reliability planning is focused on non-major event days. Utility resilience plans are assessed according to common recommended resilience components that we have identified in existing resilience frameworks. The focus of this report is on hurricanes and severe storms in which the primary hazards are precipitation or high winds. We exclude winter storms with primary hazards of ice and extreme cold, as they are a unique set of hazards with different resilience considerations. Standalone reports focusing on wildfires and winter storms have been published in parallel with this report. This report can be used as a starting point for understanding potential investment prioritization processes and investment options. This report is intended to improve utility resilience planning by supporting constructive dialogue among utilities, regulators, and other stakeholders.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Power System Resilience Metrics Augmentation for Critical Load Prioritization

One of the major goals of new grid operation regimes, such as transactive energy systems (TESs), is to make the power grid more resilient to withstand natural or man-made disasters and potential reliability events, and to continue to serve the maximum number of its customers. But it is a well-known fact to system operators that not all customers are the same. This implies that any discussion of TESs’ impacts on the resilience of the power system should consider the needs of its critical customers (such as the power system operation centers, fire and police stations, and hospitals) over those of other customers. When evaluating the resilience of the system, bonus points must be awarded to any system that could maintain its power supply to critical customers during a disturbance that may cause an outage. This report discusses critical infrastructure (CI) as found in the literature and then categorizes it based on the field to which the operations belong (such as human life/safety-related, operations management, necessary city operation, industrial customers, etc.). Each of these CI categories is further divided into types of critical customers (e.g., the human life/safety-related category has different types of customers like hospitals, fire and police stations, etc.). The entire demand of each of the critical customer types is not categorized as critical load (CL); instead, only a portion of the total load of these critical customers is characterized as critical load. This is done based on the categories of equipment, the function of which is crucial in the operation of the overall facility. CL categorization is performed to provide the ratio of the critical load portion to the overall load , so that it can serve as a parameter in the resilience evaluation of the grid through a metrics-based approach. Such categorization is important as it helps to augment the existing quantifiable resilience metrics with CL categorization. The metrics for a power system need to not only consider how well a system performed during a disturbance event, but also how it reduced strain and supplied power to its CLs. The first step in this process is characterize CLs in the system. After CL characterization, the next step is the inclusion of these loads in the resilience metrics. To that end, in this report weight-based augmentation of resilience metrics is proposed, where certain customers (the ones that are categorized as critical) are assigned higher weights than others. Though an overview of assigning weights to customers is discussed, there is no one-size-fits-all approach for every power system. The decisions made about assigning such weights to customers vary greatly from one operator to another, based on their unique systems and the current and predicted states of critical customers. This decision-making can include the type of disturbance event, which might only affect certain parts of the system. In general, analyzing critical customers before an event helps understand system vulnerabilities. It also helps in planning and conducting operations during the event, evaluating system performance after the event, and supporting better planning for future events. An alternative to the current practices of managing the grid for outages is an innovative TES, which has the potential to provide a platform for including distributed energy resources for managing CLs. This report also describes how TES qualities can help (1) to maintain power supply to critical customers for uninterrupted operations and (2) to restore lost power supply to the critical customers rapidly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

System-of-systems optimization of hydrogen infrastructure for heavy-duty freight corridors: The interstate 10 case study

Medium and heavy-duty freight transportation requires hydrogen energy infrastructure that is cost-effective, operationally reliable, spatially coherent, and resilient to demand variability along major corridors. This paper presents an integrated hydrogen corridor planning framework using Oak Ridge National Laboratory's OR-AGENT that couples freight-driven, route-resolved hydrogen demand modeling with optimized station siting, sizing, and station-level techno-economic analysis. The framework is demonstrated for the Interstate 10 freight corridor and the Houston-to-Los-Angeles region. Hydrogen demand is derived from high-resolution origin–destination freight data, duty-cycle characterization, and physics-based energy consumption modeling. Candidate refueling sites are selected from existing heavy-duty diesel fueling locations and optimized subject to onboard storage and station capacity constraints. Resulting station throughputs are evaluated using established techno-economic models for electrolytic hydrogen production and dispensing infrastructure. Results show that a regional, portfolio-level aggregation, average dispensed electrolytic hydrogen cost of $6.87–$7.26/kg is currently feasible, and is strongly influenced by demand density and utilization.

Sujan, Vivek [ORNL] (ORCID:0000000269882342)↗

Stimulated Raman Scattering Microscopy: Real-Time In-Situ Physical and Chemical Characterization of Reverse Osmosis Desalination Membrane Scaling

We introduce a stimulated Raman scattering (SRS) methodology designed for rapid, real-time, and in situ monitoring of RO membrane scaling adapted for bench-scale desalination flow cells. The methodology can provide new insights into membrane scaling dynamics by offering time-resolved reflection imaging of inorganic crystal growth, coupled with chemical identification from Raman spectral data. These capabilities allow for direct local measurement of the membrane surface area covered by different scalants as well as an approximation of the scalant volume using three-dimensional, integrated Raman intensity. The 2D and 3D SRS results obtained from CaSO 4 scaling experiments are compared to and are in reasonable agreement with those provided by confocal microscopy. The real-time physical and chemical characterization capabilities presented here could be extended to study combinations of inorganic, organic, and biological fouling. Overall, the SRS methodology represents an advancement in real-time sensing of membrane fouling that offers the potential for improved operation, lower cost, and more resilient RO membrane systems for sustainable water management.

42 ENGINEERING↗

ALD-Derived WO 3– x Leads to Nearly Wake-Up-Free Ferroelectric Hf 0.5 Zr 0.5 O 2 at Elevated Temperatures

Breaking the memory wall in advanced computing architectures will require complex 3D integration of emerging memory materials such as ferroelectrics─either within the back-end-of-line (BEOL) of CMOS front-end processes or through advanced 3D packaging technologies. Achieving this integration demands that memory materials exhibit high thermal resilience, with the capability to operate reliably at elevated temperatures, such as 125°C, due to the substantial heat generated by front-end transistors. However, silicon-compatible HfO 2 -based ferroelectrics tend to exhibit antiferroelectric-like behavior in this temperature range, accompanied by a more pronounced wake-up effect, posing significant challenges to their thermal reliability. Here, we report that by introducing a thin tungsten oxide (WO 3–x ) layer─known as an oxygen reservoir─and carefully tuning its oxygen content, ultrathin Hf 0.5 Zr 0.5 O 2 (5 nm) films can be made robust against the ferroelectric-to-antiferroelectric transition at elevated temperatures. This approach not only minimizes polarization loss in the pristine state but also effectively suppresses the wake-up effect, reducing the required wake-up cycles from 10 5 to only 10 at 125°C, a qualifying temperature for back-end memory integrated with front-end logic, as defined by the JEDEC standard. First-principles density functional theory (DFT) calculations reveal that WO 3 enhances the stability of the ferroelectric orthorhombic phase (o-phase) at elevated temperatures by increasing the tetragonal-to-orthorhombic phase energy gap and promoting favorable phonon mode evolution, thereby supporting o-phase formation under both thermodynamic and kinetic constraints.

36 MATERIALS SCIENCE↗

Analysis of Distributed Energy Storage as a Core Grid Infrastructure via Production Cost Modeling

Energy storage plays a pivotal role in enabling power system operation with more flexibility and resilience. Unlike current practice that considers energy storages as attached ancillary devices, this paper focuses on storages as a core infrastructure by looking at their spatial distribution in the system. A sensitivity analysis based on production cost modeling is conducted to demonstrate the benefits of distributed energy storages. First, the modeling of energy storages in production cost modeling is presented. Second, potential optimal locations of distributed energy storages in a power system are discussed. Finally, multiple scenarios with various numbers and locations of additional distributed energy storages in the WECC 2030 model are created. The production cost modeling results of these scenarios show that distributed energy storages have higher utilization compared to the centralized ES units and therefore provide significantly more benefits in terms of reduction in generation cost, emission cost, and volatility of location marginal prices. A saturation effect is observed suggesting the selection of optimal locations will further improve the benefits.

Nguyen, Quan H.↗

Recommendations for Minimum Required Error Codes for Electric Vehicle Charging Infrastructure

OCPP protocol manages the interaction between the EVSE and its respective back-end communication network. It plays a pivotal role in both error reporting and troubleshooting, carried out primarily through the CSMS. OCPP defines both standard error codes and a flexible framework for creating and communicating custom error codes. The OCPI protocol orchestrates the communication between different backhaul communication networks, incorporating the exchange of error codes. These error codes are instrumental in pinpointing and rectifying issues that can surface prior to, during, or after charging operations, fortifying the reliability and resilience of the EV charging infrastructure. The flexibility offered by the OCPP and OCPI frameworks through the introduction of custom error codes also creates its own set of challenges. While the integration of custom error codes allows for enhanced granularity, it also introduces inconsistencies and fragmentation within the overarching diagnostic reporting system. To address the challenges with custom error codes this report proposes a set of Minimum Required Error Codes (MRECs) for streamlined error reporting, interpretability, and diagnostics. Recommendations in this report are based on independent analysis of custom error codes from multiple stakeholders within the EV charging ecosystem. For better error resolution, this report also assigns one or more entities responsible for the resolution of every mentioned error code. Finally, a functional classification for each mentioned error code is also identified to describe the nature of the error. In summary, the purpose of this document is to simplify the troubleshooting process and increase charging reliability for all EV users. This report serves as a recommendation for industry stakeholders, encouraging a unified methodology to define, transmit, and interpret common error codes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

BRAVE_EBC-TMT.1.0

Exhaled breath condensate (EBC) represents a low-cost and non-invasive means of examining respiratory health. EBC has been used to discover and validate exhaled volatile and non-volatile biomarkers of disease related to the respiratory system distress such as asthma, COPD, lung cancer, and secondary infections. One newly emerging utilization of EBC, is proteomics analysis, which can provide an unbiased snapshot into ongoing biological processes in the airway. Fully characterizing the biological landscape of EBC collections is challenging though, due to sample variability, and low detection sensitivity. EBC is primarily composed of condensed water, causing technical challenges with detecting key macromolecules from the dilute sample matrix; therefore, high sensitivity techniques are required to unlock the full capability of EBC as a method for non-invasive biomarker detection. To overcome some of these technical challenges for proteomic analyses, we applied our recently developed microscale proteomic techniques and developed a novel TMT based approach which enabled reliable, relative quantification with significantly improved detection of low abundance peptides/proteins across multiple healthy volunteer EBC samples. Our EBC collection design includes longitudinal EBC collections from five individual healthy volunteers on three separate days of the week with triplicate, back-to-back donations each day. Here, we report a total of 235 quantifiable proteins corresponding to 1,877 non-redundant peptides for evaluating sample collection reproducibility and establishing a healthy (human host) baseline EBC biomarker proteome studies. This work will pave the way for further investigations of EBC protein expression profiles and showcase the value of using non-invasive collection method techniques for clinically relevant biomarker discovery. This research was supported by the LDRD Biomedical Resilience And Readiness in AdVerse Operating Environments (BRAVE) Project (73748), and was conducted at Pacific Northwest National Laboratory (PNNL) in Richland, WA. PNNL is a multiprogram national laboratory operated by Battelle for the Department of Energy (DOE) under Contract DE-AC05-76RLO 1830.

59 BASIC BIOLOGICAL SCIENCES↗