Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Open Air Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗

Voltron Compatible Whole Building Root-Fault Detection and Diagnosis

Buildings consume more than 40% of primary energy in the U.S. Malfunctioning sensors, components, and control systems, as well as degrading components in Heating, Ventilating and Air-conditioning (HVAC) and lighting systems are main reasons for energy waste and unsatisfactory indoor environment. Field studies have shown that an energy saving of 5-30% of total building energy consumption and improved indoor air quality can be achieved by simply applying automated fault detection and diagnosis (AFDD), followed by corrections even if these are not done in real time. Extensive research has been made on the development of component level AFDD tools in the past two decades. However, in recent years, the development of method for a whole building level AFDD has received much attention. Here, a whole building fault refers to a fault happening in one subsystem but impact on more than one subsystems, or has a significant impact on building performances, such as building’s energy consumption. Existing component level AFDD tools could fail to detect or give false alarm for faults that trigger abnormalities in multiple subsystems. Isolating such whole building faults, which have impacts on multiple subsystems, is also challenging by simply using component based AFDD solutions. On the other hand, it might be more cost-effective for medium- or small-sized commercial buildings that have subsystems (e.g. primary cooling subsystem, air loop subsystem, heating subsystem, lighting subsystem, etc.) to install one whole building level AFDD tool, rather than many component level AFDD tools, to focus on significant faults. The focus of this project is firstly to provide training opportunities in building AFDD research area for undergraduate students and to develop a workforce pipeline in building sciences. The objective of the proposed research activities is to develop cost-effective and scalable AFDD solutions for whole building level faults. The developed AFDD solution is VOLTTRONTM compatible to further increase its plug-n-play capacity and the market penetration. VOLTTRONTM is an open-source innovative distributed control and sensing software platform developed by the Pacific Northwest National Laboratory. A VOLTTRONTM compatible AFDD tool brings the benefits such as low-cost deployment, and better building to grid integration, etc. The performance of the developed whole building AFDD tools is evaluated using data collected from a mixed-use medium-sized university campus building. Another significant goal of this project is to engage undergraduate students in research activities and expose them to building control and AFDD fields. A demonstration building – Nesbitt Hall at Drexel University is identified for this study. This demonstration building has a typical HVAC system configuration, which includes a water-cooled chiller system, three variable air volume (VAV) air handling unit (AHU) systems, and a hydronic heating system. Faults, that are expected to have a whole building level impact, are artificially implemented in this demonstration building for three different seasons. Building data have been collected in this project, which include fault free building automation system (BAS) data and BAS data that contain system behaviors caused by artificially implemented and naturally occurred faults. These collected data are used to evaluate the developed whole building AFDD tools. A data-driven method, which includes a weather and schedule-based pattern matching (WPM) method and Feature based Principal Component Analysis (FPCA) method, is developed for whole building level fault detection. Parameter sensitivity tests, including snapshot window size, data sample searching pool size, etc., are implemented to evaluate the impacts of various WPM-FPCA parameters. A data-driven and expert knowledge/rule-based method using Bayesian Network (BN) and WPM is developed for whole building level fault diagnosis. The developed WPM-BN method, which includes a two-layer BN structure model and BN parameters, are either learned from baseline data or developed from expert knowledge. The developed whole building AFDD tools are evaluated using BAS data collected from the demonstration building. Using the evaluation data set, the WPM-FPCA fault detection method is evaluated under two different Principle Component (PC) retention rates, i.e., 0.65 retention rate and 0.95 retention rate. It is observed that when using 0.65 PC retention rate, the WPM-FPCA fault detection method achieves a 79% fault detection rate (this rate reaches to 85% when including the six make-up fault test cases discussed in the next bullet), while when using 0.95 PC retention rate, the WPM-FPCA fault detection method achieves 100% fault detection rate (this rate remains to be 100% when including the six make-up fault test cases). Under both PC retention rates, the WPM-FPCA fault detection method demonstrates 0% false alarm rates. Using the evaluation data set, the developed WPM-BN fault diagnosis method has successfully diagnosed thirteen (13) faults out of the fourteen (14) fault test cases. The one mis-diagnosed case exhibits fewer fault symptoms in different subsystems, when compared with other fault test cases. Overall speaking, the developed whole building AFDD solutions demonstrate satisfactory fault detection/diagnosis accuracy with very low false alarm rate. Lastly, a survey and market study has been performed to understand the existing AFDD market, including its gaps and needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Testing of Novel Semiconductor Opening Switches Using Magnetic Switching

The performance of semiconductor opening switch (SOS) diodes with different doping profiles is assessed with the primary aim of enhancing or substituting hard-to-find devices. SOS devices are capable of providing long lifetime, gigawatt level pulses in generators with risetimes on the nanosecond scale with pulse widths on the order of 20 ns. An experimental testbed is described which allows for rapid testing of diodes with control of the forward pumping time which is a crucial parameter of SOS diodes. A saturable pulse transformer provides both the initial voltage multiplication and reverse current pulse required to drive SOS diodes. Voltage multiplication ratios of 16:1 were achieved with a modest charging voltage of 800 V and simple circuitry. With current densities of up to 1.4 kA ⋅ cm -2 , the testbed produces 10 kV output pulses into a 56 Ω load with a pulsewidth of 16 ns and delivered power of up to 1.9 MW. These novel devices are compared to legacy SOS diodes originating from Russia, with one of the profiles yielding increased performance. Finally, these profiles are studied in hopes of creating manufacturing demand to augment the availability of these useful devices.

drift step recovery diodes↗

The COMBLE campaign: a study of marine boundary-layer clouds in Arctic cold-air outbreaks

One of the most intense air mass transformations on Earth happens when cold air flows from frozen surfaces to much warmer open water in cold-air outbreaks (CAOs), a process captured beautifully in satellite imagery. Despite the ubiquity of the CAO cloud regime over high-latitude oceans, we have a rather poor understanding of its properties, its role in energy and water cycles, and its treatment in weather and climate models. The Cold-air Outbreaks in the Marine Boundary Layer Experiment (COMBLE) was conducted to better understand this regime and its representation in models. COMBLE aimed to examine the relations between surface fluxes, boundary-layer structure, aerosol, cloud and precipitation properties, and mesoscale circulations in marine CAOs. Processes affecting these properties largely fall in a range of scales where boundary-layer processes, convection, and precipitation are tightly coupled, which makes accurate representation of the CAO cloud regime in numerical weather prediction and global climate models most challenging. COMBLE deployed an Atmospheric Radiation Measurement Mobile Facility at a coastal site in northern Scandinavia (69°N), with additional instruments on Bear Island (75°N), from December 2019 to May 2020. CAO conditions were experienced 19% (21%) of the time at the main site (on Bear Island). A comprehensive suite of continuous in situ and remote sensing observations of atmospheric conditions, clouds, precipitation, and aerosol were collected. Because of the clouds’ well-defined origin, their shallow depth, and the broad range of observed temperature and aerosol concentrations, the COMBLE dataset provides a powerful modeling test bed for improving the representation of mixed-phase cloud processes in large-eddy simulations and large-scale models.

54 ENVIRONMENTAL SCIENCES↗

Pollutant Concentrations and Emission Rates from Scripted Natural Gas Cooking Burner Use in Nine Northern California Homes

METHODS: Combustion pollutant concentrations were measured during the scripted operation of natural gas cooking burners in nine homes. In addition to a base condition of closed windows, no forced air unit (FAU) use, and no mechanical exhaust, additional experiments were conducted while operating an FAU and/or vented range hood. Test homes included a 26m2 two-room apartment, a 134m2 first floor flat, and seven detached homes of 117–226m2. There were four single-story, four two-story and one 1.5 story homes. Cooktop use entailed boiling and simmering activities, using water as a heat sink. Oven and broiler use also were simulated. Time-resolved concentrations of carbon dioxide (CO2), nitric oxide (NO), nitrogen oxides (NOX), nitrogen dioxide (NO2), particles with diameters of 6 nm or larger (PN), carbon monoxide (CO), and fine particulate matter (PM2.5) were measured in the kitchen (K) and bedroom area (BR) of each home. CO2, NO, NO2, and PN data from sequential experiments were analyzed to quantify the contribution of burner use to the highest 1h and 4h time-integrated concentrations in each room. RESULTS: Four of the nine homes had kitchen 1h NO2 exceed the national ambient air quality standard (100 ppb). Two other homes had 1h NO2 exceed 50 ppb in the kitchen, and three had 1h NO2 above 50 ppb in the bedroom, suggesting substantial exposures to anyone at home when burners are used for a single substantial event. In all homes, the highest 1h kitchen PN exceeded 2 x105 cm-3-h, and the highest 4h PN exceeded 3 x105 cm-3-hr in all homes. The lowest 1h kitchen/bedroom ratios were 1.3–2.1 for NO in the apartment and two open floor plan homes. The largest K/BR ratios of 1h NO2 were in a two-story 1990s home retrofitted for deep energy savings: ratios in this home were 3.3 to 6.6. Kitchen 1h ratios of NO, NO2 and PN to CO2 were used to calculate fuel normalized emission factors (ng J-1). Range hood use substantially reduced cooking burner pollutant concentrations both in the kitchen and bedroom of several homes. A hood with large capture volume and a measured flow of 108 L/s reduced concentrations 80-95%. IMPLICATIONS: These measurements demonstrate that operation of natural gas cooking burners without venting can cause short-term kitchen concentrations of NO2 to exceed the US outdoor health standard, and can elevate concentrations of NO, NO2, and ultrafine particles throughout the home. Results are generally consistent with a recent simulation study that estimated widespread 1h NO2 exposures exceeding 100 ppb in homes that use gas burners without venting. While operating a venting range hood can greatly reduce pollutant levels from burner use (and presumably from cooking as well), performance varies widely across hoods. Increased awareness of the need to ventilate when cooking would substantially reduce in-home exposure to NO2 and ultrafine particles in California homes. Helping consumers select effective hoods, for example by publishing capture efficiency performance ratings, also would help reduce exposure.

54 ENVIRONMENTAL SCIENCES↗

Fossil fuel CO 2 emissions over metropolitan areas from space: A multi-model analysis of OCO-2 data over Lahore, Pakistan

Urban areas, where gathering more than 55% of the global population, alone contributed to more than 70% of anthropogenic fossil fuel carbon dioxide (CO 2ff ) emissions. Accurate quantification of CO 2ff emissions from urban areas is of great importance to the formulation of global warming mitigation policies to achieve carbon neutrality by 2050. Satellite-based inversion techniques are unique among “top-down” approaches, potentially allowing us to track CO 2ff emission changes over cities globally. However, its accuracy is still limited by incomplete background information, cloud blockages, aerosol contaminations, and uncertainties in models and emission inventories used as prior. To evaluate the current potential of space-based quantification techniques, we present the first attempt to monitor long-term changes in CO 2ff emissions based on the OCO-2 satellite measurements of column-averaged dry-air mole fractions of CO 2 (X CO2 ) over a fast-growing Asian metropolitan area: Lahore, Pakistan. We first examined the OCO-2 data availability at global scale. About 17% of OCO-2 soundings are marked as high-quality soundings by quality flags over the global 70 most populated cities over the period 2014-2019. Cloud blockage and aerosol contamination are the two main causes of data loss. As an attempt to recover additional soundings, we evaluated the effectiveness of OCO-2 quality flags at the city level by comparing three flux quantification methods (WRF-Chem, X-STILT, and flux cross-sectional integration method), all based on the Open-Data Inventory for Anthropogenic Carbon dioxide (ODIAC) product. The satellite/bottom-up emissions (OCO-2/ODIAC) ratios of the high-quality tracks better converged across the three methods compared to the all-data tracks with reduced uncertainties in emissions. Thus, OCO-2 quality flags are useful filters of low-quality OCO-2 retrievals at local scales, although originally designed for global-scale studies. All three methods consistently suggested that the ratio medians are greater than 1, which implies that the ODIAC slightly underestimated the CO2ff emissions over Lahore. Additionally, our estimation of the a posteriori CO2ff emission trend was about 734 kt C/year (i.e., an annual 6.7% increase). 10,000 Monte Carlo simulations of the Mann-Kendall upward trend test showed that less than 10% prior uncertainty for 8 tracks (or less than 20% prior uncertainty for 25 tracks) is required to achieve a greater-than-50% trend significant possibility at a 95% confidence level. It implies that the trend is driven by the prior and not due to the assimilation of OCO-2 retrievals. The key to improving the role of satellite data in CO 2 emission trend detection lies in collecting more frequent high-quality tracks near metropolitan areas to achieve significant constraints from X CO2 retrievals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Survey of Multizone Airflow Simulation Software

H-Canyon simulates the building and process ventilation to ensure positive contamination control for any modifications as well as evaluating off-normal conditions. Simulations can also be used to identify air quality of personnel occupied areas. The models can be classified into two groups, single and multi-zone models. As the name states, a single zone model assumes that the building can be described by a single, well-mixed zone. Whereas large buildings have structures that must be described as multizone. Multizone airflow models deal with the difficulty of flows in a building by distinguishing the effects of internal flow restrictions. Several models have been developed that take internal partitions into account. CONTAM (currently used) is a multizone airflow program created by NIST to determine airflows including infiltration, exfiltration, wind pressures acting outside the building, buoyancy effects caused by the indoor and outdoor air temperature difference. COMIS is a multizone air infiltration, ventilation, and contaminant transport model that was developed at Lawrence Berkeley National Laboratory. COMIS deals with applied pressure distribution, airflow components, HVAC systems, schedules, and contaminant transport. EnergyPlus is designed by DOE. It supports flexible component level configuration of HVAC models and simulates sub-hourly time steps to control fast dynamic systems. The program features include providing accurate environmental performance data including energy consumption and carbon emissions, and reporting solar gains on surfaces. Heavent is used to model industrial ventilation systems to control airborne contaminants. It's designed based on the American Conference of Governmental Industrial Hygienists (ACGIH) Ventilation manual. DesignBuilder is the most recognized and advanced user interface to EnergyPlus. It gives access to all of the most frequently required simulation capabilities covering building fabric, thermal mass, glazing, shading renewables, and HVAC analysis. The objective of this study is to identify all relevant software available including commercially licensed, freely licensed, and open source, that can be used to simulate large, complex process facility ventilation systems. All discovered software tools are evaluated for salient features and compared to the software tool currently used to simulate the H-Canyon ventilation system. The design criteria of a ventilation system has two basic requirements: Supplying fresh air for the occupants and changing the air in the room sufficiently; therefore, the smells, fumes, and contaminants will be removed. In this study, first, whether the software simulates airflow (infiltration, natural ventilation, and interzonal) or considers them to be inputs is discussed. Second, if indoor contaminant levels are considered; and finally suggestions on how airflow analysis can be more appropriately accounted for when performing airflow simulation of a building. All of the airflow software reviewed for this study can account for constant infiltration and natural ventilation rates that are not affected by changes in indoor and outdoor conditions. Modelling infiltration in EnergyPlus or DesignBuilder are applicable for small buildings and not appropriate for larger buildings like the H-Canyon. The effect of wind on external pressures, infiltration, and natural and mechanical ventilation, can also be calculated using all of these software. These programs have control options to switch between natural to mechanical ventilation modes or both (hybrid). Interzonal airflow can be applied which means one zone can be specified to receive a fixed amount of air from another zone. The following ventilation modeling software is recommended for further testing: CONTAM, COMIS, Heavent. The next step in evaluating the software will consist of creating test facility simulations using evaluation copies of the software.

42 ENGINEERING↗

Pneumatic System for the Neutron Generator Facility at SRNL

A neutron generator system equipped with a pneumatic sample transfer system, enables scientists to perform neutron activation analysis with increased efficiency and accuracy. The samples are placed in sealed containers called 'rabbits' and are passed through the system. Once sealed in the rabbit, the samples are loaded into the tubes via a hopper mechanism. The sample is launched into the generator with compressed air and captures neutrons, causing the sample to become radioactive. Next, the sample is sent to a detector, where the samples are counted for a set length of time on a Ge detector. Once the detection is completed, the sample is then sent to the trash. The system utilizes an interface to select which generator valve and detector location to send the sample too. This project is supports the future development of the neutron generator in the F wing of 773-A. A program is used to automate the passing of the rabbit through the system. The user is able to select the generator valve and detector to be utilized in the testing of the sample. Using the 'Add Rabbit' button the user can add as many sample rabbits to rabbit editor tab. Characteristics are then entered into the fields for each rabbit. The Pre-Det Cooldown and Post-Det Cooldown are intervals used to space out the time before the rabbit is sent into and out of the detector. After all characteristics are entered, the 'Submit to Hopper' button is selected thus preparing the program to run the rabbits in the inserted order. Small setup of the system using the available parts. Simulates the movement of the rabbit from the generator to the detector. Small valves are located before each manifold. To transport the rabbit from one side to the other, the valve of the sending side must be open and the receiving side must be closed. The manifold and valve in direct line with the compressor would extend to the hopper. Once the hopper is loaded, the valve would be open to send the rabbit to generator. Additional manifolds and other mechanical parts are necessary to complete the system design. To complete the construction of the system additional parts, such as the mechanical parts for the switching mechanism and the solenoid valves, are necessary. Further, to complete the automatization of the system, an Arduino is required to communicate with the valves and adjust the linear servos appropriately so that the rabbits are sent to the selected generator location and detector. This work is aimed to be completed in the next fiscal year.

42 ENGINEERING↗

Cesium-Induced Active Sites for C–C Coupling and Ethanol Synthesis from CO 2 Hydrogenation on Cu/ZnO(000$\bar{1}$) Surfaces

The efficient conversion of carbon dioxide, a major air pollutant, into ethanol or higher alcohols is a big challenge in heterogeneous catalysis, generating great interest in both basic scientific research and commercial applications. Here, we report the facilitated methanol synthesis and the enabled ethanol synthesis from carbon dioxide hydrogenation on a catalyst generated by codepositing Cs and Cu on a ZnO(000$\bar{1}$) substrate. A combination of catalytic testing, X-ray photoelectron spectroscopy (XPS) measurements, and calculations based on density functional theory (DFT) and kinetic Monte Carlo (KMC) simulation was used. The results of XPS showed a clear change in the reaction mechanism when going from Cs/Cu(111) to a Cs/Cu/ZnO(000$\bar{1}$) catalyst. The Cs-promoting effect on C–C coupling is a result of a synergy among Cs, Cu, and ZnO components that leads to the presence of CH x and CH y O species on the surface. Furthermore, according to the DFT-based KMC simulations, the deposition of Cs introduces multifunctional sites with a unique structure at the Cu–Cs–ZnO interface, particularly being able to promote the interaction with CO 2 and thus the methanol synthesis predominantly via the formate pathway. More importantly, it tunes the CHO binding strongly enough to facilitate the HCOOH decomposition to CHO via the formate pathway, but weakly enough to allow further hydrogenation to methanol. The fine-tuning of CHO binding also enables a close alignment of a CHO pair to facilitate the C–C coupling and eventually ethanol synthesis. Our study opens new possibilities to allow the highly active and selective conversion of carbon dioxide to higher alcohols on widely used and low-cost Cu-based catalysts.

36 MATERIALS SCIENCE↗

Robust In-Situ Strain Measurements to Monitor CO 2 Storage

The goal of this project was to develop and demonstrate robust instrumentation to monitor the in-situ strain tensor in order to improve the reliability and security of CO 2 storage in geologic formations. We met the original goals of the project and the major overarching accomplishment is the advancement of strain tensor monitoring from an intriguing concept to a commercially available technology with a solid foundation of novel instruments supported by theoretical analyses and validation experiments. The main accomplishments of the project are summarized below. We designed, built and evaluated nine new optical fiber strainmeters and tiltmeters using Michelson interferometers to measure deformation with ultra-high resolution at both shallow and deep point locations in the subsurface. These are the robust strainmeters that motivated the title of the project. We designed, built and evaluated a novel method of measuring distributed strain in optical fibers with nanostrain resolution, and cm-scale location, and sampling into the seismic band. The new method is called Coherence-length-gated Microwave Photonics Interfereometry (CMPI). CMPI technology has advantages over existing commercial DAS and DSS methods. We developed and demonstrated capabilities to deploy instruments in the field and used them to measure strain caused by ambient signals like barometric pressure and tides, as well as induced signals like surface loading and pore pressure changes from pumping tests. We deployed a working strainmeter at 1,700 ft depth, slightly above an active reservoir. This is to our knowledge the greatest depth a strainmeter has been deployed and the techniques we used can readily be extended to greater depths. Optical fiber borehole tensor strainmeter techology was advanced from a TRL 4 at the start, to a TRL of 7 at the conclusion of the project. The project included advances in simulations and theoretical analyses. We developed and demonstrated a computational workflow that uses machine learning to reduce the computational requirements and make it practical to use Bayesian inversion to solve large numerical poroelastic analyses needed to interpret strain tensor field data. We evaluated the strain tensor fields and time series that would be caused by leaks of CO 2 or other fluids from reservoirs. These simulations demonstrated that signals from leaks could be measured with instruments developed for the project, opening a potentially new method for ensuring storage security. We showed that strains in caprock can be used to estimate pressure in a reservoir. This avoids the need to drill monitoring wells into the reservoir, and it expands the capabilities of monitoring in the caprock. The project includes a derivation and application of a novel analytical solution to the strains in the vicinity of a pressurized poroelastic inclusion. This solution explains field data measured during injeciton tests at the North Avant Field, and it will simplify future interpretation of strain tensor data. The project included a broad range of experiments, and of the most significant is the characterization of the strain tensor at an array three strainmeters during six injection tests at the North Avant Field, Oklahoma. This demonstrated repeatability of the strain signal measured by the new instruments developed for the project, and it showed similarities between the strain signal at shallow depths and pressure in the underlying reservoir. We also demonstrated that useful strain data can be measured at reservoir depths. This confirms that strain tensor data can be measured throughout the caprock over a reservoir. The project demonstrated the feasibility of using the strain tensor and distributed strain measured in caprock during a variety of different well tests where the pumping rate was constant, sinusoidal and positive, or a periodic square wave with zero net rate. This further strengthens the validity of using strain data to characterize reservoirs and aquifers. We also demonstrated that strain caused be fluctuations of air pressure and water pressure in the vadose zone can be measured and interpreted, suggesting that high resolution distributed strain measurements hold promise for monitoring the vadose zone. The project partially supported nine graduate students in the Environmental Engineering, Hydrogeology, Electrical Engineering programs at Clemson University. The research was described in nine journal papers, 23 talks and conference abstracts. Additional journal papers are in preparation. A new company called Tensora was started to provide strainmeter technology for commercial applications.

01 COAL, LIGNITE, AND PEAT↗

Warming-Induced Biome Change at the Temperate-Boreal Ecotone: An Experimental Test of Key Regeneration Processes (Final Technical Report)

This project advanced our understanding of plants’ key physiological and ecological processes that are essential to the survival, success, and carbon cycling of plants from the boreal-temperate forest ecotone in the future climate. A primary goal of the project was to test the effect of warming and water limitation on plants from the Boreal-Temperate Ecotone using a realistic outdoor long-term experiment. Plant at this ecotone is predicted to be particularly sensitive to future climate since the ecotone represents a relatively sharp boundary between many temperate species to the south and boreal species to the north. This work was important, as there was and still is a significant uncertainty surrounding the mechanisms of future climate effects on vegetation compositional and carbon cycling change, especially in forests mostly due to lack of experimental examination of response to warming and limited water availability. Consequently, we tested our central objective, that was to assess the potential for projected climate to alter tree species composition and carbon cycling at the southern boreal-temperate forest ecotone by experimentally warming forest plots and documenting effects on establishment and juvenile performance for tree species near their warmer (boreal species) and colder (temperate species) range limits in northern Minnesota. To accomplish our goals, we designed and built a successful highly manipulative experiment that implemented vegetation-soil warming and rainfall removal in both understory and open habitats at two sites in northern Minnesota (MN). The sites lie at different distances to the north of the ecotone between the southern boreal and northern temperate forest biomes. We focused on ten target species, all of which are near their warmer (Pinus banksiana, Picea glauca, Abies balsamea, Populus tremuloides, Betula papyrifera) or colder (Pinus strobus, Quercus macrocarpa, Quercus rubra, Acer rubrum, Acer saccharum) range edge in northern MN; we also studied other species such as a woody invader and native herbs and shrubs. Three temperature treatments (ambient, +1.7°C, +3.4°C) were imposed using infra-red heating lamps augmented with soil heating cables to simultaneously control soil and vegetation temperatures, enabling assessment of non-linear responses. These temperatures bracket the range of anticipated warming in the region during the next 75-100 years. In addition, we implemented summer rain removal treatment mimicking predicted distribution in precipitation patterns by future climate where we actively removed ~40% of rainfall. Measurements included germinant establishment, plant growth, phenology, physiology and survival, soil, plant and air temperature, soil moisture and nutrient status. These measures enabled us to assess how germination, growth and survival at the establishment stage are influenced by direct climate effects and/or indirect effects of warming, soil resources such as water and nutrients availability or other environmental variables that either directly or indirectly influence plant performance.

60 APPLIED LIFE SCIENCES↗

Machine learning enables reconstruction of past fire regimes from charcoal-derived fire intensity and fuel composition

Background Fire is a foundational ecological process that shapes ecosystem structure, diversity, and resilience. Quantifying paleofire regime attributes such as frequency, severity, and intensity is essential for understanding the historical range of variability in fire behavior and its ecological effects. While frequency and severity are often reconstructed in paleofire studies, quantitative reconstructions of fire intensity remain limited. Recent work has shown that maximum pyrolysis temperature—a proxy for fire intensity—and plant species type can be inferred from charcoal using transmission Fourier-transform infrared (FTIR) spectroscopy. However, the sample preparation for transmission FTIR is destructive and time-consuming, limiting application and reuse of materials for other analyses. We evaluated reflectance FTIR spectroscopy as a non-destructive alternative for reconstructing combustion temperature and plant species from laboratory-generated charcoal. We also examined the influence of contrasting airflow environments (ambient air versus nitrogen-rich) on pyrolysis temperature and plant species reconstruction prediction accuracies and compared predictive performance between a novel, neural network–based deep learning model with the traditional modern analogue technique (MAT) using k-nearest neighbor functions. As proof of concept, we apply our enhanced methodology to ancient charcoal to demonstrate applicability at improving long-term fire regime reconstructions and the ability to link paleofire records with contemporary fire ecology. Results Our analysis shows that transmission and reflectance FTIR spectra yield comparable spectral profiles. However, sample preparation for reflectance FTIR is minimal and non-destructive, unlike transmission FTIR which is destructive. We demonstrate that oxygen environments improved reconstruction accuracy relative to nitrogen-rich conditions. Finally, our deep learning neural network (DL) achieved testing accuracies of 98.7% for temperature and 96.2% for species identification, outperforming MAT’s k-NN approach (89.8% and 65.9%, respectively). A Shapley importance analysis identified 5 key spectral regions that greatly influenced the model’s temperature or species categorization. When applied to ancient charcoal, our results show historic fires from the most recent past primarily burned at low intensities (400–500 °C), reflective of natural fire regimes in ponderosa pine forests. Our results corroborate charcoal morphology data that suggests all ancient charcoal originated from burned woody plant types. Conclusions By combining reflectance FTIR spectroscopy with a deep learning approach, we provide the first accuracies high enough to confidently identify both species and temperature from laboratory-produced charcoal, improving quantitative reconstructions of fire intensity and fuel composition from paleofire records. This opens a wide range of research into the link between fire and larger drivers (i.e., climate or human) and greater ecological understanding of fire regimes beyond that of burn scars or recent observations. These methodological improvements have direct relevance for fire management by improving interpretation of historical fire behavior, informing fuel–fire relationships, and providing a scalable analytical framework applicable to both long-term ecological studies and contemporary fire science.

54 ENVIRONMENTAL SCIENCES↗

PG&E WaveConnect Program (Final Report)

The PG&E WaveConnect project was intended to demonstrate the technical and economic viability of wave power in the open ocean adjacent to PG&E's service territory. WaveConnect was conceived as a multi-stage development process leading to long-term megawatt-scale wave power production. The first-stage tasks consisted of site selection, permitting, pilot plant design, and assessment of technology and commercial readiness. The second stage would have included development of infrastructure, undersea cabling, and deployment of wave energy conversion devices (WECs). In the third stage, the most promising WEC devices would have been deployed in larger quantities and connected to the grid. This report documents the findings of Stage One. Site Selection: After studying the wave energy potential, grid interconnection and other project infrastructure along the California coast, PG&E selected two sites: one near Eureka, called the Humboldt WaveConnect (HWC) project, and another near Vandenberg Air Force Base, called the Central Coast WaveConnect project (CCWC).

16 TIDAL AND WAVE POWER↗

Damage imaging in a laminated composite plate using an air-coupled time reversal mirror

We demonstrate the possibility of selectively imaging the features of a barely visible impact damage in a laminated composite plate by using an air-coupled time reversal mirror. The mirror consists of a number of piezoelectric transducers affixed to wedges of power law profiles, which act as unconventional matching layers. The transducers are enclosed in a hollow reverberant cavity with an opening to allow progressive emission of the ultrasonic wave field towards the composite plate. The principle of time reversal is used to focus elastic waves at each point of a scanning grid spanning the surface of the plate, thus allowing localized inspection at each of these points. The proposed device and signal processing removes the need to be in direct contact with the plate and reveals the same features as vibrothermography and more features than a C-scan. More importantly, this device can decouple the features of the defect according to their orientation, by selectively focusing vector components of motion into the object, through air. For instance, a delamination can be imaged in one experiment using out-of-plane focusing, whereas a crack can be imaged in a separate experiment using in-plane focusing. As a result, this capability, inherited from the principle of time reversal, cannot be found in conventional air-coupled transducers.

36 MATERIALS SCIENCE↗

MEASUR - Manufacturing Energy Assessment Software for Utility Reduction

MEASUR your energy savings with the free DOE MEASUR software The Department of Energy (DOE), with Oak Ridge National Laboratory (ORNL), released version 1.0 of their energy efficiency software tool MEASUR (Manufacturing Energy Assessment Software for Utility Reduction). MEASUR has been available for several years as a beta version, being tested by industry experts and real users, and will continue to be updated and improved in the coming years. It is an integrated suite of tools to aid manufacturers in improving the efficiency of energy systems and equipment within a plant, including motors, pumps, fans, process heating, steam, and compressed air. Additionally, there are modules for wastewater energy analysis and to help perform energy treasure hunts. Several calculators are also included, allowing users to independently perform smaller calculations and analyses (such as estimating pump head, performing a fan traverse analysis, estimating waste heat recovery potential, and cataloging compressed air leaks). The MEASUR modules are based on previous DOE software tools that have been used by industry since the early 2000s (such as MotorMaster, AirMaster+, PSAT, PHAST, and FSAT). The original tools only ran on Windows operating systems, and by Windows 10, most of them were inoperable. DOE started their energy efficiency software tool revitalization effort in 2016, first with PSAT (for pumps), then began to integrate the other tools and expand their functionality and utility. The new MEASUR suite provides an extensively more user-friendly, modern, and versatile set of tools. All the assessment modules and most of the calculators have several visual components and graphs and detailed help text for every user input. To help reach international users, the tool utilizes Google translate and users can easily change unit systems, even converting existing user inputs if desired. The assessment files can be organized within the internal file system and easily shared to other users, regardless of their operating system. The entire suite is free, open-source, and can be downloaded on Windows, Mac, or Linux operating systems.

Accawi, Gina [Oak Ridge National Lab. (ORNL), Oak ↗

Effects of injection angle orientation on concave and convex surfaces film cooling

The present study employs a transient liquid crystal thermography to measure film cooling performance over constant curvature of concave and convex surfaces. This work investigates detailed distributions of both film cooling effectiveness and heat transfer coefficient on concave and convex surfaces with one row of injection holes inclined stream-wise at 35 at four blowing ratios (0.5, 1.0, 1.5 and 2.0) on four test pieces with different hole configurations. All test models have a row of discrete holes with a stream-wise injection angle {gamma} of 35 and a pitch-to-diameter ratio (P/d) of 3. The current work examines four different injection configurations, one with simple and three with 8 forward-expanded holes. Three compound angles of 0, 45 and 90 with air ({rho}{sub c}/{rho}{sub m} = 0.98) as coolants are tested under the mainstream Reynolds number (Re{sub d}) of 2300 on concave surface, and 1700 on convex surface. Measured results of the concave surface show that both the span-wise averaged heat transfer coefficient and film cooling effectiveness increase with blowing ratios for all tested models. Higher heat transfer levels induced by large flow disturbance of compound-angle injection also lead to poorer overall film cooling performance, especially at high blowing ratio and large span-wise injection angle. Present results show that the best surface protection on the concave surface over the widest range of M can be provided by the forward-expanded holes with {beta} = 0 (Model-B), followed by the forward-expanded holes with {beta} = 45 (Model-C). Convex surface results show that the compound-angle injection indicates increases in both film cooling effectiveness and heat transfer at moderate and high blowing ratios. The forward-expanded hole with simple-angle injection provides the best film performance because of high film cooling effectiveness and low heat transfer coefficient at blowing ratio of 0.5. (author)

42 ENGINEERING↗

Enabling Staged Pressurized Oxy-Combustion: Improving Flexibility and Performance at Reduced Cost

Introduction: The staged pressurized oxy-combustion (SPOC) process, developed by Washington University in St. Louis (WUSTL), is an oxy-combustion carbon capture technology that employs a steam power cycle to generate electricity. As with atmospheric-pressure oxy-combustion processes, carbon dioxide (CO 2 ) capture rates of 90% or higher can be achieved. The staged-combustion approach of the SPOC process, when operated at elevated gas pressure, allows for near elimination of flue gas recycle (FGR) and leads to significant improvements in efficiency and reduced costs. The primary goal of this project was to investigate the potential for SPOC for flexible operation beyond the capabilities of conventional coal-fired power plants, particularly those employing carbon capture and storage (CCS). Oxy-combustion differs from conventional coal combustion in that the combustion of coal is carried out using oxygen as opposed to air. The resultant flue gas is a mixture of primarily CO 2 and water, greatly simplifying CO 2 capture. As SPOC does the oxy-combustion process under pressure, it is higher efficiency and lower cost than atmospheric oxy-combustion. The project was led by the Electric Power Research Institute, Inc., with the assistance of WUSTL, Doosan Babcock (DBL – boiler plant original equipment manufacturer), and Air Liquide (AL – air separation experts). The specific objectives of the project were to: (1) Evaluate the SPOC concept and develop a risk-based approach to the heating surface layout ensuring that performance (gas and steam side), manufacturing, transportation, and plant erection considerations were fully accounted for in the system design. (2) Improve the technology to ensure its performance and cost potential are substantially better than today’s baseline pulverized coal power plant with post-combustion capture (PCC) or atmospheric oxy-combustion, and show progress toward performance commensurate with projected commercial operation, including 90% or more CO 2 capture. (3) Address critical technology gaps and improving overall system performance for the technology. (4) Perform combustion tests at scale under commensurate pressure to the commercial operating system validate combustor and advance the SPOC combustion modeling tools that will facilitate full-scale design. Combustion Testing: Testing was initially carried out at atmospheric pressure with methane to ensure that all systems were correctly operating. Following this, the testing then proceeded to moderate pressure operation at 4 bara, where different stoichiometric conditions were used across an extended heat input range, showing that a stable flame could be maintained. Testing then proceeded at 10 and 15 bara where it was shown that the ignition system needed to be replaced at these operating conditions. When testing recommenced, a similar stable flame shape was achieved, without any methane support, and the full 100 kWth coal oxy-combustion was demonstrated. Heat flux measurements showed 400 kW/m 2 (0.126 MMBtu/hr-ft 2 ) from the flame, within the 450 kW/m 2 (0.142 MMBtu/hr-ft 2 ) preferred limit defined by DBL for the full-scale design case. Carbon monoxide and carbon-in-ash measurements showed that complete combustion was possible with ultra-low excess oxygen at 1 vol % in the product flue gas. This allowed the full-scale models to be calculated based on this level of excess oxygen, improving the performance of the system as lower feed oxygen is produced in the air separation unit (ASU), saving auxiliary power. Full-Scale Design: The full-scale design is sized to deliver 550 MWe net electrical power output to allow direct comparison with the National Energy Technology Laboratory (NETL) baseline cases using the same Montana Powder River Basin (PRB) fuel. The cases used for direct comparison are: Case S12A (supercritical [SC] coal without CO 2 capture), Case S12B (SC coal with PCC at 90% CO 2 capture, and Case S12F (atmospheric oxy-combustion SC coal with 90% CO 2 capture). The SPOC stages were configured to be identical arrangements, allowing for a more straightforward design, construction, and control strategy. Each stage consists of two PVs, the first being the combustor PV module and the second being the convective PV module. The combustor module is the tallest vessel, with local coal feeding equipment and the burner FGR and oxygen plenums at the top and ash management at the bottom. The combustor module is effectively an open cross section with membrane tubes around the circumference – this unobstructed slender profile ensures that the relatively slower burnout mechanism needed for the low-speed turbulent mixing burner can proceed unimpeded and that molten ash will not attach to any surfaces at an angle to the predominant flue gas flow. The steam turbine used in the SPOC design is essentially the same unit utilized in the atmospheric oxy-combustion case except the degree of heat recovery possible allows the low-pressure (LP) feedwater heater train to be eliminated. This is a result of being able to capture the latent heat of evaporation of the moisture produced in the combustion (normally lost to the stack). The SPOC system outperforms the NETL atmospheric oxy-combustion baseline case by 3.3% points and the PCC case by 7.5% points. This performance increase is mainly a result of the improved heat recovery possible from the product flue gas and from the reduced auxiliary power consumption from the ASU and the CO 2 compression and purification unit over the atmospheric equivalent. The combined improvement in boiler efficiency and reduction in the steam turbine heat rate resulted in a net improvement in the overall plant efficiency by 0.61%, to 35.6% on a HHV basis. This relatively small improvement in plant efficiency between sub-bituminous and bituminous coals shows the value of useful moisture latent heat recovery offered by the SPOC system when using low rank fuels. Flexibility and Turndown: The SPOC system has inherent high turndown capabilities because of a demonstrated high range of combustion stability and the ability to bypass stages, thereby reducing steam generation rates proportionally without altering firing rates in operating stages. ASU units do not generally offer significant turndown opportunities as they are limited by the performance of the compression plant. The baseline SPOC design has a 2-train ASU configuration, needed to be able to meet the 10,500 tonnes per day duty, that can deliver efficient turndown points between 85–100% load with both trains operating, and at 45–50% load with a single train operating. Outside these operating points, the flexibility and efficiency are limited and may be uncompetitive at loads below 45% as the ASU systems are unable to turndown beyond 85% for the base case and 70% for the flexible case. The ASU cold box for the flexible case was designed to operate at loads between 40-100%, below this operating range the purity of the produced oxygen cannot be guaranteed, resulting in additional load for the CPU equipment. The additional power consumption of these cases yields an uneconomic operating condition with poor efficiency when operating at low loads such as 25% and 12%. To address this flexibility constraint, AL evaluated how the ASU configuration could be altered to deliver efficient oxygen supply over the load range. This involved integrating the compressor duties across both ASU trains into a shared duty arrangement with multiple compressors, strategically sized to deliver the duty required across all load ranges between 40–100% by enabling different combinations of the main air compressors and the booster air compressors. The oxygen purity cannot be guaranteed below 40% load for each train – the power consumption at 25% and 12% loads were estimated based on the multi-compressor configuration at maximum turndown as these load cases were not considered in the flexible ASU design. With a different cold box configuration, i.e. number of trains, the entire load range could be delivered within oxygen purity specifications. Although there is a small efficiency reduction at full load, there are significant improvements in overall plant performance during low-load operation. The exact ASU configuration needed will therefore be dependent on the expected operating profile of the unit. Economic Analysis: Cost estimates for the baseline and the flexible cases were developed using NETL baseline case data for common BOP items and an Association for the Advancement of Cost Engineering International Class 5 (conceptual/screening study) assessment of key components unique to the SPOC system. The capital, operating, and maintenance costs were assessed along with the first-year power cost, levelized cost of electricity, and CO 2 captured and avoided cost for the SPOC cases were compared against the relevant NETL baseline cases in January 2019 dollars. Both SPOC cases achieve a lower cost that the alternative NETL baseline cases (with the flexible SPOC case being slightly higher than the baseline SPOC case due to the compounded impact of higher capital costs and lower efficiency at full load). The SPOC cases deliver a lower cost of CO 2 avoided than the NETL baseline cases due to greater efficiency in generating low-carbon power. However, the cost of CO 2 captured is higher because the higher efficiency of the SPOC process generates less CO 2 , hence less needs to be captured, resulting in a high capital cost being shared over a reduced CO 2 quantity. The flexible ASU adds 1.6% overall to the plant cost in comparison to the baseline case, but the efficiency improvements at loads below 50% are significant. Subsequently, depending on the plant load-profile expectation, the flexible ASU would be beneficial if the plant spends a significant portion of its operating life below 50% load. This kind of operating profile is likely to be required for all fossil plants when more renewable electricity generators are installed on the local grid, particularly solar power that can be predicted ahead of time, allowing for appropriate pricing signals to be incorporated into the diurnal cycle. R&D Recommendations: SPOC, while a promising technology, is a relatively recent concept and, as such, operability issues of combustor design and steam-side integration for such systems at a scale relevant to commercial deployment have not been evaluated. WUSTL has conducted extensive small pilot-scale (100 kWth) research to understand and advance pressurized oxy-combustion processes, including investigation of combustion and flame characteristics, radiative heat flux, burner operability, turn down, char burnout, ash characteristics, water-wash column operation, etc. for pressurized oxy-combustion systems. Nonetheless, at this stage in the development of the SPOC process, what is needed is a large-scale pilot plant that can serve to study pressurized oxy-combustion systems and components at a scale commensurate with the maturity of the technology. A scale of 10 MWth, which includes steam-side integration and two stages would yield essential information with respect to heat transfer characteristics both in the radiative and convective sections of the pressure vessels, and the ability to operate the fuel staging process. In addition, while modeling results indicate that combustion and flame characteristics improve with scale, direct studies of the combustor at this scale will ensure that the models can be relied upon for scale up to commercial scale. Furthermore, a detailed analysis must be performed to understand the scaling aspects of key components and systems.

20 FOSSIL-FUELED POWER PLANTS↗

Progress in model development to quantify High Explosive Violent Response (HEVR) to mechancial insult

The rapid release of chemical energy has found application for industrial and military purposes since the invention of gunpowder. Black powder, smokeless powder of various compositions, and pyrotechnics all exhibit the rapid release of energy without detonation when they are being used as designed. The rapidity of energy release for these materials is controlled by adjustments to the particle surface area (propellant grain configuration or powder particle size) in conjunction with the measured pressure-dependent burning rate, which is very subsonic. In this way a manufacturing process can be used to engineer the desired violence of the explosion. Detonations in molecular explosives, in contrast, propagate with a supersonic velocity that depends on the loading density, but is independent of the surface area. In ideal detonations, the reaction is complete within a small distance of the propagating shock front. Non-ideal detonations in molecular and composite explosives proceed with a slower velocity, and the reaction may continue well behind the shock front. We are developing models to describe the circumstances when molecular and composite explosives undergo a rapid release of energy without detonating. The models also apply to the behavior of rocket propellants subject to mechanical insult, whether for accidents (Hazards) or the suite of standardized tests used to assess whether the system can be designated an Insensitive Munition (IM). In the application described here, we are studying an HMX (1,3,5,7-tetranitro-1,3,5,7-tetraazacyclooctane) explosive developed in the UK, which is 91% by weight HMX and 9% binder-plasticizer. Most explosives and propellants, when subjected to a mechanical insult, drop or impact that is well below the threshold for detonation have been observed to react violently. This behavior is known as High Explosive Violent Reaction (HEVR). The basis of our model is the observation that the mechanical insult produces damage in a volume of the explosive near the trajectory of the impactor. The damage is manifest as surface area through the creation of cracks and fragments, and also as porosity through the separation of crack faces and isolation of the fragments. Open porosity permits a flame to spread easily and so ignite the surface area that was created. The surface area itself leads to in increase in the mass-burning rate. As the kinetic energy and power of the insult increases, the degree of damage and the volume of damage both increase. Upon a localized ignition, the flame spreads to envelop the damaged volume, and the pressure rises at an accelerated rate until neither mechanical strength nor inertial confinement can successfully contain the pressure. The confining structure begins to expand. This reduces the pressure and may even extinguish the flame. Both the mass of explosive involved and the rate at which the gas is produced contribute to each of several different measures of violence. Such measures include damage to the confinement, the velocity and fragment size distributions from what was the confinement, and air blast. Figure 1 illustrates the interaction of the various phenomena described above. Our model comprises several interacting elements. The production of damage, the ignition criterion, the mass rate of burning (reaction rate), the equations of state and constitutive models of the solid explosive reactant (unburned) and gas products, flame propagation in damaged reactant, and the progressive failure of the confinement are all elements of the model. The model is intended for implementation in a general-purpose simulation program (hydrocode) that solves the partial differential equations for the conservation of mass, momentum, and energy in conjunction with equations of state and strength.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗