Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OUTDOORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Environmental Persistence of Biological Aerosols in Outdoor and Simulated Environments

The fate of biological aerosols in the atmosphere depends on the unique and dynamic environmental conditions it is exposed to during transport. There exist many processes that can impact the effectiveness of an aerosol release, and its fate in the environment. Aerosol properties may be modified if biological particles that are released into the atmosphere interact with free radicals, volatile organic compounds(VOC), semi-volatile organic compounds, and inorganic gasphase compounds, such as NOx and SOx. Meteorological conditions such as ultraviolet(UV)- light, relative humidity(RH), and temperature have also been shown to affect biological aerosols, with interactions dependent on both the organism and aerosol's chemical make-up. Oxidation or secondary-organic aerosol (SOA) formations on the particle can also lead to changes in surface proteins and extra-cellular nucleic acids that may agent detection technologies, at a different rate than the infectivity of the agents. Once modified, agents may then be transported via many atmospheric processes such as deposition or incorporation into cloud condensation nuclei(CCN). Although these processes are known, it is unclear what the resulting form and potency ofthe bioaerosol may be after alteration by these processes.

54 ENVIRONMENTAL SCIENCES↗

Network Models of Active Degradation Mechanisms and Pathways for Service Life Prediction of Indoor and Outdoor PV Modules

ct: PV service lifetime prediction (SLP) enables accurate calculation of levelized cost of energy (LCOE), which is crucial to rationalizing PV investment and installation. However, SLP is challeging since PV reliability in the field is affected by many combined factors, including various environmental stresses and module quality. In order to map out the active degradation mechanisms and pathways that best resemble real world conditions, we introduce the framework of a study protocol and use network models fitted to data, to enable analysis and SLP of complex PV systems with multiple active degradation mechanisms. The study protocol is the experimental design, including module variants and different exposure conditions, selection of evaluation methods, time-series data acquisition and training of network models to these data. We present SLP of minimodules in the lab and PV systems in the field. For lab SLP, minimodules with 8 variants based on manufacturer, architecture, and encapsulation were prepared and aged in modified damp heat with or without full spectrum light exposure. Stepwise I-V and Suns-Voc data acquisition tracks changes in electrical properties including Rs,IV, Isc,IV, Vmp,PIV providing insights into power loss of minimodules. Network structural equation modeling (netSEM) was utilized to construct degradation pathway models that identify active degradation mechanisms and predict power loss over time. For field SLP, datastreams of Pmp values and I-V curve datastreams of two types of modules installed in three distinctly different Köppen-Geiger climate zones for 9 years were acquired. With power loss modes corresponding to uniform current loss (ΔPIsc), recombination (ΔPVoc), series resistance (ΔPRs), and current mismatch (ΔPImis) determined, the performance loss rates (PLR) were determined using PVplr. We show how to establish a study protocol framework to ensure appropriate parametric variations and valid data collection from the variants of your complex systems. Then the data-driven netSEM model fitting provides a comprehensive mapping of multiple active degradation mechanisms, and accurate service life prediction.

network model, degradation, photovoltaic, solar↗

Very High Efficiency Dedicated Outdoor Air System Field Site Re-Evaluation

The study reported here evaluated the long-term performance of Very High Efficiency (VHE) Dedicated Outside Air Systems (DOASs) installed at eight sites that participated in field evaluation studies performed by the Northwest Energy Efficiency Alliance (NEEA) and Institute for Market Transformation (IMT) from 2015 through 2020. The study compared the energy performance of the systems in 2021-2022 to the findings of the original evaluation. It also evaluated the indoor environmental quality (IEQ) as perceived by occupants and building operator feedback before and after the system conversion. The findings of the study are important for building owners and managers who are considering adopting VHE DOASs. The study found that the systems: (1) consistently saved energy over the long term, (2) improved occupant comfort, and (3) received positive feedback from building operators. All of the sites had similar or improved energy savings over the pre-conversion system compared to the original evaluation savings, and only one site had a small reduction in energy savings. The sites averaged 48 percent whole site energy savings compared to the pre-conversion system. The continued energy performance of these sites provides strong evidence that the energy savings achieved by VHE DOAS retrofits will be sustained long term. The study also investigated the changes in occupant comfort resulting from the VHE DOAS retrofit. Responses to a survey sent to the sites’ occupants revealed that the conversion resulted in a better indoor environment for the occupants. Most respondents reported that their satisfaction increased, and dissatisfaction decreased post-conversion. Overall occupants were 43 percent more satisfied and 30 percent less dissatisfied post-conversion compared to pre-conversion. The study's findings suggest that a VHE DOAS can be a solution to improve the energy efficiency, reduce energy costs, and increase occupant comfort in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PV Reference Cells for Outdoor Use: Stability Over Four Years of Deployment

Photovoltaic (PV) reference cells are frequently used to evaluate the performance of PV power plants. They provide a measure of irradiance that strongly correlates with the electrical output of PV modules, which makes them very useful for detecting short-term anomalies or long-term degradation in PV power plant output. One very important quality is long-term stability. This report presents observations about the stability of a set of 22 commercial reference cells that have been in continuous operation for a period of four years at the Solar Radiation Research Laboratory (SRRL) site at the National Renewable Energy Laboratory (NREL). The 22 reference cells at the SRRL represent 10 different models from 6 manufacturers.

14 SOLAR ENERGY↗

Technical Justifications for Outdoor Bulk Gaseous Hydrogen Storage Setback Distances

Setback distances define a prescribed distance between a potentially hazardous system and different types of other systems, people, buildings, or materials that may be exposed to that hazard. Riskinformed separation distances are not meant to completely eliminate risk, but rather to limit the risk to an acceptable level. A sensitivity study of risk suggested that a leak size of 3% of the pipe cross-sectional area would be a conservative but reasonable basis. Calculation of the setback distances for gaseous hydrogen was done in a deterministic manner, using a selected leak size and harm criteria for each group of exposures. Harm criteria have been updated to better reflect the exposure types under consideration, and to be consistent with setback distances for liquid hydrogen. The resulting setback distance values are primarily driven by radiative heat flux values for all exposure groups. For the typical pipe sizes, the setback distances slightly increase compared to the previous version of NFPA 2.

08 HYDROGEN↗

WRF-Comfort: simulating microscale variability in outdoor heat stress at the city scale with a mesoscale model

Abstract. Urban overheating and its ongoing exacerbation due to global warming and urban development lead to increased exposure to urban heat and increased thermal discomfort and heat stress. To quantify thermal stress, specific indices have been proposed that depend on air temperature, mean radiant temperature (MRT), wind speed, and relative humidity. While temperature and humidity vary on scales of hundreds of meters, MRT and wind speed are strongly affected by individual buildings and trees and vary on the meter scale. Therefore, most numerical thermal comfort studies apply microscale models to limited spatial domains (commonly representing urban neighborhoods with building blocks) with resolutions on the order of 1 m and a few hours of simulation. This prevents the analysis of the impact of city-scale adaptation and/or mitigation strategies on thermal stress and comfort. To solve this problem, we develop a methodology to estimate thermal stress indicators and their subgrid variability in mesoscale models – here applied to the multilayer urban canopy parameterization BEP-BEM within the Weather Research and Forecasting (WRF) model. The new scheme (consisting of three main steps) can readily assess intra-neighborhood-scale heat stress distributions across whole cities and for timescales of minutes to years. The first key component of the approach is the estimation of MRT in several locations within streets for different street orientations. Second, mean wind speed and its subgrid variability are downscaled as a function of the local urban morphology based on relations derived from a set of microscale LES and RANS simulations across a wide range of realistic and idealized urban morphologies. Lastly, we compute the distributions of two thermal stress indices for each grid square, combining all the subgrid values of MRT, wind speed, air temperature, and absolute humidity. From these distributions, we quantify the high and low tails of the heat stress distribution in each grid square across the city, representing the thermal diversity experienced in street canyons. In this contribution, we present the core methodology as well as simulation results for Madrid (Spain), which illustrate strong differences between heat stress indices and common heat metrics like air or surface temperature both across the city and over the diurnal cycle.

Geology↗

Solar collector performance evaluated outdoors at NASA-Lewis Research Center

The study of solar reflector performance reported is related to a project in which solar collectors are to be provided for the solar heating and cooling system of an office building at NASA's Langley Research Center. The solar collector makes use of a liquid consisting of 50% ethylene glycol and 50% water. A conventional air-liquid heat exchanger is employed. Collector performance and solar insolation data are recorded along with air temperature, wind speed and direction, and relative humidity.

Vernon, R. W.↗

Real time outdoor exposure testing of solar cell modules and component materials

Plastic samples, solar cell modules, and sub-modules were exposed at test sites in Florida, Arizona, Puerto Rico, and Cleveland, Ohio, in order to determine materials suitable for use in solar cell modules with a proposed 20-year lifetime. Various environments were encountered including subtropical, subtropical with a sea air atmosphere, desert, rain forest, normal urban, and urban-polluted. The samples were exposed for periods up to six months. Materials found not suitable were polyurethane, polyester, Kapton, Mylar, and UV-stabilized Lexan. Suitable materials were acrylic, FEP-A, and glass. The results of exposure of polyvinylidene fluoride were dependent on the specific formulation, but several types appear suitable. RTV silicone rubber (clear) appears to pick up and hold dirt both as a free film and as a potting medium for modules. The results indicate that dirt accumulation and cleanability are important factors in the selection of solar cell module covers and encapsulants.

Anagnostou, E.↗

Thermal performance evaluation of Solar Energy Products Company (SEPCO) 'Soloron' collector tested outdoors

The test article, Model EF-212, Serial Nr. 002, is a single glazed collector with a nonselective absorber plate, using flowing air as the heat transfer medium. The absorber plate and box frame are aluminum and the insulation is one inch isocyanurate foam board with thermal conductivity of 0.11 (BTU/sq ft Hr0/ft.) The tests included the following. (1) time constant test, (2) collector efficiency test, (3) collector stagnation test, (4) incident angle modifier test, (5) load test, (6) weathering test, and (7) absorber plate optical properties test. The results of these tests are tabulated, graphed, or otherwise recorded.

Chiou, J., Sr.↗