Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OMEGA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Evolution of the Design and Fabrication of Astrophysics Targets for Turbulent Dynamo (TDYNO) Experiments on OMEGA

Although the overall function of a campaign’s primary target design may remain unchanged, the components and structure often evolve from one shot day to the next to better meet experimental goals. The target fabrication engineer’s involvement in this evolution can be important for advising modifications in order to improve and simplify assembly at the same time. Highly complex targets are constructed by General Atomics (GA) for astrophysics experiments conducted by the University of Chicago at the OMEGA laser facility. Several novel target components are fabricated, precision-assembled, and extensively measured in support of this campaign, and have evolved over the last three years to improve both the science and assembly. Examples include unique laser machined polyimide grids to enhance plasma mixing at target center, precision micromachined cylindrical shields that also act as component spacers, drawn glass target supports to suspend physics packages at critical distances, and tilted pinholes for collimated proton radiography. Target component fabrication and evolution details for this turbulent dynamics (TDYNO) campaign are presented, along with precision-assembly techniques, metrology methods, and considerations for future TDYNO experiments on OMEGA.

42 ENGINEERING↗

Timing of pulsars in the globular cluster omega centauri

We present the timing of the first five millisecond pulsars discovered in the globular cluster Omega Centauri and the discovery of a pulsar with a spin period of 3.68 ms. With a timing baseline of ~3.5 yr we are able to measure the derivative of the spin frequency ($\dot{\nu }$) for the first five pulsars. Upper limits on the pulsar line-of-sight acceleration are estimated and compared with predictions based on analytical models of the cluster. We find that PSRs J1326-4728B and D show large negative accelerations, which are in tension with the minimum acceleration predicted by analytical models. We searched for pulsed γ-ray signals using 14.3 yr of data from the Fermi Large Area Telescope. Although we found no evidence for γ-ray pulsations, PSRs J1326-4728A, B, C, and E are associated with X-ray sources. This suggests that the observed γ-ray emission from Omega Centauri is likely caused by the emission of the ensemble of MSPs. Finally, the linearly polarized emission from PSR J1326-4728A yields a rotation measure of -18 ± 8 rad m -2 .

79 ASTRONOMY AND ASTROPHYSICS↗

Parametrization of the relativistic {sigma}-{omega} model for nuclear matter

We have investigated the zero-temperature equation of state (EoS) for infinite nuclear matter within the {sigma}-{omega} model at all densities n{sub B} and different proton-neutron asymmetry {eta}{identical_to}(N-Z)/A. We have presented an analytical expression for the compression modulus and found that nuclear matter ceases to saturate at {eta} slightly larger than 0.8. Afterward, we have developed an analytical method to determine the strong coupling constants from the EoS for isospin symmetric nuclear matter, which allow us to reproduce all the saturation properties with high accuracy. For various values of the nucleon effective mass and the compression modulus, we have found that the quartic self-coupling constant G{sub 4} is negative, or positive and very large. Furthermore, we have demonstrated that it is possible (a) to investigate the EoS in terms of n{sub B} and {eta}; and (b) to reproduce all the known saturation properties without G{sub 4}. We have thus concluded that the latter is not necessary in the {sigma}-{omega} model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Seasonal Parameterizations of the Tau-Omega Model Using the ComRAD Ground-Based SMAP Simulator

NASA's Soil Moisture Active Passive (SMAP) mission is scheduled for launch in November 2014. In the prelaunch time frame, the SMAP team has focused on improving retrieval algorithms for the various SMAP baseline data products. The SMAP passive-only soil moisture product depends on accurate parameterization of the tau-omega model to achieve the required accuracy in soil moisture retrieval. During a field experiment (APEX12) conducted in the summer of 2012 under dry conditions in Maryland, the Combined Radar/Radiometer (ComRAD) truck-based SMAP simulator collected active/passive microwave time series data at the SMAP incident angle of 40 degrees over corn and soybeans throughout the crop growth cycle. A similar experiment was conducted only over corn in 2002 under normal moist conditions. Data from these two experiments will be analyzed and compared to evaluate how changes in vegetation conditions throughout the growing season in both a drought and normal year can affect parameterizations in the tau-omega model for more accurate soil moisture retrieval.

SMAP↗

Measurement of the branching fractions of the singly Cabibbo-suppressed decays $$ {\Lambda}_{\textrm{c}}^{+}\to \textrm{p}\eta $$ and $$ {\Lambda}_{\textrm{c}}^{+}\to \textrm{p}\omega $$

Abstract Based on 4.5 fb −1 e + e − collision data collected with BESIII detector at seven energy points between 4.600 and 4.699 GeV, the branching fractions for$$ {\Lambda}_c^{+}\to p\eta $$ Λ c + → pη and$$ {\Lambda}_c^{+}\to p\omega $$ Λ c + → pω were measured by means of single-tag method. The branching fractions of$$ {\Lambda}_c^{+}\to p\eta $$ Λ c + → pη and$$ {\Lambda}_c^{+}\to p\omega $$ Λ c + → pω are determined to be (1.57±0.11 stat ±0.04 syst )×10 −3 and (1.11±0.20 stat ±0.07 syst )×10 −3 , with a statistical significance of greater than 10σand 5.7σ, respectively. These results are consistent with the previous measurements by BESIII, LHCb and Belle, and the result of$$ {\Lambda}_c^{+}\to p\eta $$ Λ c + → pη is the most precise to date.

Physics↗

One-loop omega-potential of quantum fields with ellipsoid constant-energy surface dispersion law

Rapidly convergent expansions of a one-loop contribution to the partition function of quantum fields with ellipsoid constant-energy surface dispersion law are derived. The omega-potential is naturally decomposed into three parts: the quasiclassical contribution, the contribution from the branch cut of the dispersion law, and the oscillating part. The low- and high-temperature expansions of the quasiclassical part are obtained. An explicit expression and a relation of the contribution from the cut with the Casimir term and vacuum energy are established. The oscillating part is represented in the form of the Chowla-Selberg expansion of the Epstein zeta function. Various resummations of this expansion are considered. The general procedure developed is then applied to two models: massless particles in a box both at zero and nonzero chemical potential, and electrons in a thin metal film. Rapidly convergent expansions of the partition function and average particle number are obtained for these models. In particular, the oscillations of the chemical potential of conduction electrons in graphene and a thin metal film due to a variation of size of the crystal are described. - Highlights: > We study quantum fields with ellipsoid constant-energy surface dispersion law. > Rapidly convergent expansions of the omega-potential are derived. > Various resummations of the Chowla-Selberg expansion are obtained. > We establish a relation of the Casimir term with the vacuum energy. > Oscillations of the chemical potential of electrons in graphene are described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A suite of neutron time-of-flight detectors to measure hot-spot motion in direct-drive inertial confinement fusion experiments on OMEGA

A suite of six neutron time of flight detectors capable of measuring the primary DT neutron energy spectrum has recently been completed on the OMEGA Laser System. The detectors are positioned along multiple quasi-orthogonal lines of sight (LOS’s) in either a stand-alone, collinear, or antipodal configuration. The collinear detector configuration enables one to measure the neutron velocity along the detector LOS independent of the neutron-production history, while the antipodal detector configuration enables one to directly measure of the hot-spot velocity along the detector axis and Gamow velocity shift due to the plasma ion temperature. Using these six measurements of the primary DT neutron energy spectrum, the neutron-averaged hot-spot velocity and Gamow velocity shift of DT fusion neutrons have been measured in cryogenic experiments on OMEGA for the first time. Finally, the detector suite is operable between DT neutron yields of 1 × 10 13 to 2 × 10 14 with an uncertainty of ~14 km/s in the neutron-averaged hot-spot velocity measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser-system model for enhanced operational performance and flexibility on OMEGA EP

The development of laser performance models having real-time prediction capability for the OMEGA EP laser system has been essential in meeting requests from its user community for increasingly complex pulse shapes that span a wide range of energies. The laser operations model PSOPS provides rapid and accurate predictions of OMEGA EP laser-system performance in both forward and backward directions, a user-friendly interface and rapid optimization capability between shots. We describe the model’s features and show how PSOPS has allowed real-time optimization of the laser-system configuration in order to satisfy the demands of rapidly evolving experimental campaign needs. We also discuss several enhancements to laser-system performance accuracy and flexibility enabled by PSOPS.

42 ENGINEERING↗

Monitoring and characterization of particle contamination in the pulse compression chamber of the OMEGA EP laser system

The laser-damage performance of optics is known to be negatively affected by microscale particle contamination induced by the operational environment. This work investigates the properties of particles accumulating in various locations near critical optics inside the OMEGA EP grating compressor chamber during quarterly operational periods over a 2-year duration. The particles found were characterized using optical microscopy, scanning electron microscopy and energy dispersive X-ray spectroscopy. The analysis indicates significant concentrations of micrometer- to nanometer-scale particles inside the vacuum chamber, with higher values observed near the port leading to the OMEGA EP target chamber. The distribution of the chemical composition of these particles varies between collection periods. Although understanding of the mechanisms of particle generation and transport remains uncertain, the hypothesis is that this particle load represents a risk for contaminating the surfaces of high-value optics located inside the chamber, including the compression gratings and deformable mirrors, and therefore affecting their laser-damage resistance and overall operational lifetime.

47 OTHER INSTRUMENTATION↗

Hard x-ray transmission crystal spectrometer at the OMEGA-EP laser facility

The transmission crystal spectrometer (TCS) is approved for taking data at the OMEGA-EP laser facility since 2009 and will be available for the OMEGA target chamber in 2010. TCS utilizes a Cauchois type cylindrically bent transmission crystal geometry with a source to crystal distance of 600 mm. Spectral images are recorded by image plates in four positions, one IP on the Rowland circle and three others at 200, 400, and 600 mm beyond the Rowland circle. An earlier version of TCS was used at LULI on experiments that determined the x-ray source size from spectral line broadening on one IP positioned behind the Rowland circle. TCS has recorded numerous backlighter spectra at EP for point projection radiography and for source size measurements. Hard x-ray source size can be determined from the source broadening of both K shell emission lines and from K absorption edges in the bremsstrahlung continuum, the latter being a new way to measure the spatial extent of the hard x-ray bremsstrahlung continuum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-dimensional simulations of the neutron yield in cryogenic deuterium-tritium implosions on OMEGA

Maximizing the neutron yield to obtain energy gain is the ultimate goal for inertial confinement fusion. Nonuniformities seeded by target and laser perturbations can disrupt neutron production via the Rayleigh-Taylor instability growth. To understand the effects of perturbations on the neutron yield of cryogenic DT implosions on the Omega Laser Facility [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)], two-dimensional DRACO[P. B. Radha et al., Phys. Plasmas 12, 056307 (2005)] simulations have been performed to systematically investigate each perturbation source and their combined effects on the neutron-yield performance. Two sources of nonuniformity accounted for the neutron-yield reduction in DRACO simulations: target offset from the target chamber center and laser imprinting. The integrated simulations for individual shots reproduce the experimental yield-over-clean (YOC) ratio within a factor of 2 or better. The simulated neutron-averaged ion temperatures <T{sub i}> is only about 10%-15% higher than measurements. By defining the temperature-over-clean, its relationship to YOC provides an indication of how much the hot-spot volume and density are perturbed with respect to the uniform situation. Typically, the YOC in OMEGA experiments is of the order of {approx}5%. The simulation results suggest that YOC can be increased to the ignition hydroequivalent level of 15%-20% (with <{rho}R>=200-300 mg/cm{sup 2}) by maintaining a target offset of less than 10 {mu}m and employing beam smoothing by spectral dispersion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absorption of the omega and phi mesons in nuclei

The properties of hadrons, such as their masses and widths, are predicted to be modified in dense and/or hot nuclear matter. Particular attention has been given to the modifications of vector-meson properties in ordinary nuclear matter where chiral symmetry is predicted to be partially restored due to a change in the quark condensate. Different models predict relatively large measurable changes in the mass and/or the width of these mesons. The e{sup +}e{sup -} decay channel of these mesons has negligible final-state interactions (FSI), providing an ideal tool to study their possible in-medium modifications Due to its short lifetime, the {rho} meson has a substantial probability of decaying in the nucleus and its study has been previously reported. Due to their long lifetimes, the {omega} and {phi} mesons are ideal candidates for the study of possible modifications of the in-medium meson-nucleon interaction through their absorption inside the nucleus. These mesons have been photo-produced in several targets ranging from deuterium to lead. Nuclear transparencies ratios have been derived for different decay channels. These ratios indicate larger in-medium widths compared with what have been reported in other reaction channels. The absorption of the {omega} meson is stronger than that reported by the CBELSATAPS experiment. These results are compared to recent theoretical models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Three-dimensional modeling of direct-drive cryogenic implosions on OMEGA

The effects of large-scale (with Legendre modes ≲10) laser-imposed nonuniformities in direct-drive cryogenic implosions on the OMEGA laser system are investigated using three-dimension hydrodynamic simulations performed using a newly developed code ASTER. Sources of these nonuniformities include an illumination pattern produced by 60 OMEGA laser beams, capsule offsets (~10 to 20 μm), and imperfect pointing, energy balance, and timing of the beams (with typical σ rms ~10 μm, 10%, and 5 ps, respectively). Two implosion designs using 26-kJ triple-picket laser pulses were studied: a nominal design, in which a 880-μm-diameter capsule is illuminated by the same-diameter beams, and a “R75” design using a capsule of 900 μm in diameter and beams of 75% of this diameter. Simulations found that nonuniformities because of capsule offsets and beam imbalance have the largest effect on implosion performance. These nonuniformities lead to significant distortions of implosion cores resulting in an incomplete stagnation. The shape of distorted cores is well represented by neutron images, but loosely in x-rays. Simulated neutron spectra from perturbed implosions show large directional variations and up to ~ 2 keV variation of the hot spot temperature inferred from these spectra. The R75 design is more hydrodynamically efficient because of mitigation of crossed-beam energy transfer, but also suffers more from the nonuniformities. Furthermore, simulations predict a performance advantage of this design over the nominal design when the target offset and beam imbalance σ rms are reduced to less than 5 μm and 5%, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sensitivity of chemical vapor deposition diamonds to DD and DT neutrons at OMEGA and the National Ignition Facility

The particle-time-of-flight (pTOF) detector at the National Ignition Facility (NIF) is used routinely to measure nuclear bang-times in inertial confinement fusion implosions. The active detector medium in pTOF is a chemical vapor deposition diamond. Calibration of the detectors sensitivity to neutrons and protons would allow measurement of nuclear bang times and hot spot areal density (ρR) on a single diagnostic. This study utilizes data collected at both NIF and Omega in an attempt to determine pTOF’s absolute sensitivity to neutrons. At Omega pTOF’s sensitivity to DT-n is found to be stable to within 8% at different bias voltages. At the NIF pTOF’s sensitivity to DD-n varies by up to 59%. This variability must be decreased substantially for pTOF to function as a neutron yield detector at the NIF. As a result, some possible causes of this variability are ruled out.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A high-resolving-power x-ray spectrometer for the OMEGA EP Laser (invited)

A high-resolving-power x-ray spectrometer has been developed for the OMEGA EP Laser System based on a spherically bent Si [220] crystal with a radius of curvature of 330 mm and a Spectral Instruments (SI) 800 Series charge-coupled device. The instrument measures time-integrated x-ray emission spectra in the 7.97- to 8.11-keV range, centered on the Cu K{sub α1} line. To demonstrate the performance of the spectrometer under high-power conditions, K{sub α1,2} emission spectra were measured from Cu foils irradiated by the OMEGA EP laser with 100-J, 1-ps pulses at focused intensities above 10{sup 18} W/cm{sup 2}. The ultimate goal is to couple the spectrometer to a picosecond x-ray streak camera and measure temperature-equilibration dynamics inside rapidly heated materials. The plan for these ultrafast streaked x-ray spectroscopy studies is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding the effects of laser imprint on plastic-target implosions on OMEGA

Understanding the effects of laser imprint on target performance is critical to the success of direct-drive inertial confinement fusion. Directly measuring the disruption caused by laser imprints to the imploding shell and hot-spot formation, in comparison with multidimensional radiation–hydrodynamic simulations, can provide a clear picture of how laser nonuniformities cause target performance to degrade. With the recently developed x-ray self-emission imaging technique and the state-of-the-art physics models recently implemented in the two-dimensional hydrocode DRACO , a systematic study of laser-imprint effects on warm target implosions on OMEGA has been performed using both experimental results and simulations. By varying the laser-picket intensity, the imploding shells were set at different adiabats (from α = 2 to α = 6). As the shell adiabats decreased, it was observed that (1) the measured shell thickness at the time the hot spot lit up became larger than the uniform one-dimensional (1-D) predictions; (2) the hot-spot core emitted earlier than the corresponding 1-D predictions; (3) the measured neutron yield first increased then decreased as the shell adiabat α was reduced; and (4) the hot-spot size reduced as α decreased for cases where SSD (smoothing by spectral dispersion) was on but became larger for low-α shots in cases where SSD was off. Most of these experimental observations are well reproduced by DRACO simulations with laser imprints including modes up to λ max = 200. In addition, these studies identify the importance of laser imprint as the major source of degrading target performance for OMEGA implosions of adiabat α ≤ 3. Mitigating laser imprints is required to improve low-α target performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-dimensional hydrodynamic simulations of OMEGA implosions

Here, the effects of large-scale (with Legendre modes ≲10) asymmetries in OMEGA direct-drive implosions caused by laser illumination nonuniformities (beam-power imbalance and beam mispointing and mistiming), target offset, and variation in target-layer thickness were investigated using the low-noise, three-dimensional Eulerian hydrodynamic code ASTER. Simulations indicate that these asymmetries can significantly degrade the implosion performance. The most important sources of the asymmetries are the target offsets (~10 to 20 μm), beam-power imbalance (σ rms ~ 10%), and variations (~5%) in target-layer thickness. Large-scale asymmetries distort implosion cores, resulting in a reduced hot-spot confinement and an increased residual kinetic energy of implosion targets. The ion temperature inferred from the width of simulated neutron spectra is influenced by bulk fuel motion in the distorted hot spot and can result in up to an ~1 -keV increase in apparent temperature. Similar temperature variations along different lines of sight are observed. Demonstrating hydrodynamic equivalence to ignition designs on OMEGA requires a reduction in large-scale target and laser-imposed nonuniformities, minimizing target offset, and employing highly efficient mid-adiabat (α = 4) implosion designs, which mitigate cross-beam energy transfer and suppress short-wavelength Rayleigh–Taylor growth.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of cryogenic target position and implosion core offsets on OMEGA

Cryogenic target implosions currently performed on the University of Rochester’s OMEGA Laser System are of DT-filled polystyrene shells held at near the triple point temperature (~20 K) inside a cooled shroud that must be retracted from around the target just before the target is illuminated by OMEGA. As a consequence, impulses may be imparted to the target stalk, causing the target to depart from its ideal position centered at the aim point of the laser beams. The positions of cryogenic targets at the start of the laser pulse are determined in this work by comparing the positions of images of the cryogenic target implosion to that of a non-cryogenic target implosion that is accurately centered on the aim point of the beams. Images are from an array of up to five digitally recorded, x-ray pinhole cameras. Positions of the resultant implosion cores are determined along a single line of sight from x-ray images of these cores taken with an x-ray microscope operating in time-integrated mode. The offsets of the cryogenic-target cores relative to the non-cryogenic-target cores are found to have a magnitude and direction consistent with the core forming in the direction of the target offset at the start of the laser pulse. Here, the inferred offsets are therefore consistent to each other within errors. Neutron yields are seen to be affected by target offset although with considerable scatter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗