Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

A comparison of the neutron detection efficiency and response characteristics of two pixelated PSD-capable organic scintillator detectors with different photo-detection readout methods

Here, we characterize the performance of two pixelated neutron detectors: a PMT-based array that utilizes Anger logic for pixel identification and a SiPM-based array that employs individual pixel readout. The SiPM-based array offers improved performance over the previously developed PMT-based detector both in terms of uniformity and neutron detection efficiency. Each detector array uses PSD-capable plastic scintillator as a detection medium. We describe the calibration and neutron efficiency measurement of both detectors using a 137 Cs source for energy calibration and a 252 Cf source for calibration of the neutron response. We find that the intrinsic neutron detection efficiency of the SiPM-based array is (30.2 ± 0.9)%, which is almost twice that of the PMT-based array, which we measure to be (16.9 ± 0.1)%.

47 OTHER INSTRUMENTATION↗

A new neutron time-of-flight detector for yield and ion-temperature measurements in DT implosions on OMEGA

A new neutron time-of-flight (nTOF) detector for yield and ion-temperature measurements in deuterium–tritium (DT) implosions was designed, installed, and calibrated on the OMEGA Laser System. This detector was installed at θ = 46.8° from the vertical and φ = 84.9°, previously a region without other detectors, in order to decrease the uncertainty of low-mode asymmetry measurements by six other nTOF detectors. The new nTOF detector uses the “PMT only” concept [Glebov et al., Rev. Sci. Instrum. 92, 013509 (2021)] and consists of a Photek photomultiplier tube (PMT)-110 in a thin aluminum housing. There is no lead shielding in front of the PMT to allow measurements of the x-ray instrument response function of the detector. The detector is installed in the OMEGA H2-port line of sight at 9.3 m from the target chamber center in the OMEGA Target Bay and is called the H2 nTOF detector. The H2 nTOF measures DT yields in the 1 × 10 13 to 3 × 10 14 range and ion temperatures from 2 to 12 keV. H2 nTOF reduced the hotspot flow uncertainty in the z-direction from ±10 to ±8 km/s, and the uncertainty in the anisotropic flow axis from σ θ = ±26° to ±13° and σ φ = ±25° to ±21°. Here, the design details, performance, and calibration results of the H2 nTOF detector in DT implosions on OMEGA will be presented.

Laser fusion↗

Progress Update on the MUSIC Critical Benchmark

The Measurement of Uranium Subcritical and Critical (MUSiC) experiment was carried out from December 2020 through April 2021 at the National Criticality Experiments Research Center (NCERC). This measurement campaign featured bare configurations of the Rocky Flats highly-enriched uranium (HEU) shells, with each configuration having different numbers of these shells. The goal of the experiment was to test multiple neutron multiplicity detectors and measurement methods for a large range of neutron multiplication values. The large range of multiplications allows researchers to see when the combination of detectors and methods break down as the configurations reach the delayed supercritical window. The critical configurations were the extreme end of the multiplication range in MUSIC configurations. A critical benchmark in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook is planned to help further validate nuclear data. Even though there are many benchmarks focusing on the fast spectrum for highly-enriched uranium, an additional benchmark that is well documented and up to the modern standard of the handbook would be a welcome addition. Given that there are no other materials such as moderators or significant reflectors, and its similarity to Lady Godiva, it is possible that this could be very useful for validation of 235 U nuclear data in the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The HIBEAM instrument at the European spallation source

The European spallation source (ESS) will be the world’s brightest neutron source and will open a new intensity frontier in particle physics. The HIBEAM collaboration aims to exploit the unique potential of the ESS with a dedicated ESS instrument for particle physics which offers world-leading capability in a number of areas. The HIBEAM program includes the first search in thirty years for free neutrons converting to antineutrons and searches for sterile neutrons, ultralight axion dark matter and nonzero neutron electric charge. This paper outlines the capabilities, design, infrastructure, and scientific potential of the HIBEAM program, including its dedicated beamline, neutron optical system, magnetic shielding and control, and detectors for neutrons and antineutrons. Additionally, we discuss the long-term scientific exploitation of HIBEAM, which may include measurements of the neutron electric dipole moment and precision studies of neutron decays.

47 OTHER INSTRUMENTATION↗

Comparative scintillation performance of EJ-309, EJ-276, and a novel organic glass

An organic glass scintillator developed by Sandia National Laboratories was characterized in terms of its light output and pulse shape discrimination (PSD) properties and compared to commercial liquid (EJ-309) and plastic (EJ-276) organic scintillators. The electron light output was determined through relative comparison of the 137 Cs Compton edge location. The proton light yield was measured using a double time-of-flight technique at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a tunable broad-spectrum neutron source and an array of pulse-shape-discriminating observation scintillators, a continuous measurement of the proton light yield was performed for EJ-309 (200 keV–3.2 MeV), EJ-276 (170 keV–4.9 MeV), and the organic glass (50 keV–20 MeV) . Finally, the PSD properties of the organic glass, EJ-309, and EJ-276 were evaluated using an AmBe source and compared via a figure-of-merit metric. The organic glass exhibited a higher electron light output than both EJ-309 and EJ-276. Its proton light yield and PSD performance were comparable to EJ-309 and superior to that of EJ-276. Finally, with these performance characteristics, the organic glass scintillator is well poised to replace current state-of-the-art PSD-capable scintillators in a range of fast neutron detection applications.

47 OTHER INSTRUMENTATION↗

Conceptual Design of Passive Neutron Albedo Reactivity and Active Neutron Albedo Reactivity Instruments for Various Arrangements of Pebble Bed Reactor Pebbles

MCNP6 simulations were performed to assess the anticipated capability of the Passive Neutron Albedo Reactivity technique for nuclear safeguards measurements of irradiated pebble/pebbles. Two physical setups were examined. One with a single pebble of three different burnups and one with 27 pebbles in a cube. For all cases the sensitivity to removing all the fissile material was examined. For both of the physical setups, 4 assay cases were examined: (a) singles count rates for which the only source neutrons were the inherent neutrons in the fuel, (b) singles count rates again except this time two relatively weak AmLi sources were placed above and below the top central pebble and the combined effect of both neutron source terms were examined, (c) doubles count rates for which the only source neutrons were the inherent neutrons in the fuel, and (d) doubles count rates again except this time two relatively weak AmLi sources were placed above and below the top central pebble and the combined effect of both neutron source terms were examined. Finally, a few parameters such as Cd near the 3 He tubes were perturbed to see if the results could be improved.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

GENESIS: Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering

Improved neutron inelastic scattering cross section data are needed to inform integral benchmark studies and advance applications in a wide variety of areas including nuclear energy, stockpile stewardship, nonproliferation, and space exploration. Neutron inelastic scattering also serves as a non-selective probe of low-lying nuclear structure. To help meet these needs, the Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) was constructed at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. This array couples high-resolution γ-ray detectors and fast neutron detectors to achieve single and coincident n/γ detection over a broad energy range. The current configuration of the array includes 26 organic liquid scintillators and four high-purity germanium detectors (two single-crystal and two four-crystal CLOVER detectors with two-fold segmentation). The array was constructed with minimal supporting material and designed to cover a wide range of secondary particle angles and energies with limited inter-element scattering. Data acquisition is accomplished using Mesytec MDPP-16 multi-channel high-resolution digital pulse processing modules. The array characteristics, including γ-ray and neutron energy resolution, timing resolution, and detection efficiency were measured and used to validate a Geant4 model of the array. Furthermore, the primary sources of neutron background and the uncertainties in the determination of incident and secondary neutron energy were assessed. GENESIS provides a new capability to address nuclear data needs and facilitates the advancement of a wide range of nuclear applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

3D isotope density measurements by energy-resolved neutron imaging

Abstract Tools for three-dimensional elemental characterization are available on length scales ranging from individual atoms, using electrons as a probe, to micrometers with X-rays. However, for larger volumes up to millimeters or centimeters, quantitative measurements of elemental or isotope densities were hitherto only possible on the surface. Here, a novel quantitative elemental characterization method based on energy-resolved neutron imaging, utilizing the known neutron absorption cross sections with their ‘finger-print’ absorption resonance signatures, is demonstrated. Enabled by a pixilated time-of-flight neutron transmission detector installed at an intense short-pulsed spallation neutron source, for this demonstration 3.25 million state-of-the-art nuclear physics neutron transmission analyses were conducted to derive isotopic densities for five isotopes in 3D in a volume of 0.25 cm 3 . The tomographic reconstruction of the isotope densities provides elemental maps similar to X-ray microprobe maps for any cross section in the probed volume. The bulk isotopic density of a U-20Pu-10Zr-3Np-2Am nuclear transmutation fuel sample was measured, agrees well with mass-spectrometry and is evidence of the accuracy of the method.

36 MATERIALS SCIENCE↗

Passive Confirmation of the Presence Of High-Explosive Material Via Neutron Transmission Spectroscopy

The goal of this project was to explore a novel approach for identifying presence and potential types of high explosives (HE) in treaty-controlled items with passive neutron sources by using passive neutron transmission spectroscopy. We predominantly look to measure relative elemental abundance of Carbon, Hydrogen, Oxygen, and Nitrogen (CHON) since most relevant materials are certain mix of these elements, as shown in Table 1. Previously, most studies exploring potential identification of CHON elemental content of targets in the vicinity of passive neutron source were focused solely on gamma spectroscopy using high resolution gamma detectors. Using neutron transmission spectroscopy with pulse-shape discrimination (PSD) capable organic scintillators is not only a novel idea in of itself, but arguably necessary for accurate identification of the CHON elemental content of an interrogated target. While high resolution gamma spectroscopy in principle can determine a presence of hydrogen and nitrogen, it is effectively blind to a quantitatively measuring areal densities of C, O. The initially proposed approach, described in detail in the project proposal, was to leverage previous Monte Carlo study on neutron transmission spectroscopy using slab shaped target interrogated with well-collimated (“pencil”) neutron beam. In this study, a simulated test CO 2 target was interrogated by a pencil neutron beam and transmitted neutron spectra were measured using PSD capable organic scintillator using MLEM based unfolding technique. To establish relative elemental content of carbon and oxygen, the unfolded neutron spectrum was fit with a parametrized combination of their respective elemental spectral templates. The individual spectral template was calculated by convoluting ENDF neutron crosssection with the known resolution of the PSD detector used in the study. This approach in the studied configuration successfully quantitatively established relative elemental composition of carbon and oxygen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional reconstruction of implosion stagnation in laser direct drive on OMEGA

Multidimensional effects on hot-spot formation must be considered to better understand the current limits on the performance of direct-drive inertial confinement fusion experiments on OMEGA with cryogenically layered solid deuterium–tritium targets. A comprehensive reconstruction effort has been established at the Laboratory for Laser Energetics to infer hot-spot and shell conditions at stagnation from a large collection of x-ray, neutron, and particle detectors along multiple lines of sight. Several time-gated and time-integrated x-ray imagers are being used to record the shape of the hot-spot plasma. A 3D hot-spot x-ray emission tomography technique has been developed to infer low-mode drive asymmetries from the hot-spot shape. A suite of neutron diagnostics is used to provide measurements of hot-spot flow velocity, ion temperature, and areal density. Here, the information obtained from the x-ray and neutron detectors will be combined into a coherent model of the shape of the hot spot and shell assembly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron-induced capture-to-fission cross section ratio measured at LANSCE

Capture-to-fission cross section ratios are used as an alternative to absolute cross section measurements. This is due to the simplification on the calculations and the reduction of the uncertainties with respect to an absolute measurement of the cross section by eliminating experimental complications like self-absorption, beam/target overlap and non-uniformities. Different capture-to-fission reactions have been measured through the years at the Los Alamos Neutron Science Center (LANSCE) at Los Alamos National Laboratory (LANL) using the Detector for Advanced Neutron Capture Experiments (DANCE) combined with different fission detectors. Some of these are a Parallel Plate Avalanche Counter (PPAC) to detect fission fragments (FF), and the NEUtron detector array at DANCE (NEUANCE) to detect fission neutrons. As DANCE detects the γ-rays produced in capture and fission reactions, the fission instrument placed inside the DANCE cavity is used to tag the fission γ-rays for background identification and subtraction. Some examples of capture-to-fission ratio measurements performed with DANCE in the last years are the 233 U, 235 U and 239 Pu. The measurement technique, the different setups, and other potential applications of the instruments will be explained.

Nuclear Criticality Safety Program (NCSP)↗

The Mini-CAPTAIN liquid argon time projection chamber

This manuscript describes the commissioning of the Mini-CAPTAIN liquid argon detector in a neutron beam at the Los Alamos Neutron Science Center (LANSCE), which led to a first measurement of high-energy neutron interactions in argon. The Mini-CAPTAIN detector consists of a Time Projection Chamber (TPC) with an accompanying photomultiplier tube (PMT) array sealed inside a liquid-argon-filled cryostat. The liquid argon is constantly purified and recirculated in a closed-loop cycle during operation. The specifications and assembly of the detector subsystems and an overview of their performance in a neutron beam are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of uranium-photofission neutrons with a 4 He scintillation detector

The use of photon active interrogation to detect special nuclear material has held significant theoretical promise, as the interrogating source particles, photons, are fundamentally different from one of the main signatures of special nuclear material: neutrons produced in nuclear fission. However, neutrons produced by photonuclear reactions in the accelerator target, collimator, and environment can obscure the fission neutron signal. These (γ, n) neutrons could be discriminated from fission neutrons by their energy spectrum, but common detectors sensitive to the neutron spectrum, like organic scintillators, are typically hampered by the intense photon background characteristic of photon-based active interrogation. In contrast, high-pressure 4 ⁢He-based scintillation detectors are well-suited to photon active interrogation, as they are similarly sensitive to fast neutrons and can measure their spectrum, but show little response to gamma rays. Here, in this work, a photon active interrogation system utilizing a 4 ⁢He scintillation detector and a 9 MeV linac-bremsstrahlung x-ray source was experimentally evaluated. The detector was shown to be capable of operating in intense gamma-ray environments and detecting photofission neutrons from 238 ⁢U when interrogated by this x-ray source. The photofission neutrons show clear spectral separation from (γ, n) neutrons produced in lead, a common shielding material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance evaluation of neutron noise analysis in detecting special nuclear materials

Reliable and rapid inspection techniques play a vital role in preventing illicit trafficking of special nuclear materials. Active interrogation systems using neutrons produced by portable, high-flux deuterium-deuterium or deuterium-tritium neutron generators are being actively developed as a secondary scanning tool for this purpose. In this study, a neutron noise analysis-based approach for detecting unshielded and shielded special nuclear materials by using a pulsed deuterium-tritium neutron generator was evaluated. Here, this approach analyzes the fluctuation of neutron counts. Its performance was quantified with regard to time-to-detection to achieve a minimum probability of detection of 99% and a probability of false alarm of less than 1% considering various amounts of special nuclear materials and different shielding configurations. It was demonstrated that this approach could detect 17 uranium slugs in 5 s given a neutron generator yield of 8.1 × 10 7 n/s. These slugs could be detected within a reasonable time frame (200 s) when they were shielded by 10.16 cm of high-density polyethylene. The results obtained using the neutron noise analysis approach were compared with those obtained using the commonly used differential die-away analysis technique, a sensitive technique for detecting the presence of fissile materials by utilizing the prompt fission neutrons produced when the source neutrons from a neutron generator are completely diminished. For example, the time to detect 2 unshielded uranium slugs was 2.1 s when using the differential die-away analysis technique; it increased to 93 s for the neutron noise analysis approach. Although the noise analysis-based approach exhibits an overall performance which is not as good as that of differential die-away, neutron noise provides an alternative method for effective detection of special nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of D–D fusion neutrons generated in nanowire array laser plasma using Timepix3 detector

Here, we present results of the neutron detection in laser plasma experiment with CD2 nanowire target. A hybrid semiconductor pixel detector Timepix3 covered with neutron converters was using for the detection neutrons. D-D fusion neutrons were detected in a plastic converter through recoiled protons. Both the energy of recoiled protons and time-of-flight of neutrons (and thus their energy) were determined. We report (2.4±1.8) × 10 7 neutrons generated for 1 J of incoming laser energy. Furthermore, we proved that Timepix3 is suitable for difficult operational conditions in laser experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Real-time mixed reality display of dual particle radiation detector data

Radiation source localization and characterization are challenging tasks that currently require complex analyses for interpretation. Mixed reality (MR) technologies are at the verge of wide scale adoption and can assist in the visualization of complex data. Herein, we demonstrate real-time visualization of gamma ray and neutron radiation detector data in MR using the Microsoft HoloLens 2 smart glasses, significantly reducing user interpretation burden. Radiation imaging systems typically use double-scatter events of gamma rays or fast neutrons to reconstruct the incidence directional information, thus enabling source localization. The calculated images and estimated ’hot spots’ are then often displayed in 2D angular space projections on screens. By combining a state-of-the-art dual particle imaging system with HoloLens 2, we propose to display the data directly to the user via the head-mounted MR smart glasses, presenting the directional information as an overlay to the user’s 3D visual experience. We describe an open source implementation using efficient data transfer, image calculation, and 3D engine. We thereby demonstrate for the first time a real-time user experience to display fast neutron or gamma ray images from various radioactive sources set around the detector. We also introduce an alternative source search mode for situations of low event rates using a neural network and simulation based training data to provide a fast estimation of the source’s angular direction. Using MR for radiation detection provides a more intuitive perception of radioactivity and can be applied in routine radiation monitoring, education & training, emergency scenarios, or inspections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗