Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NaI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

An Invited Preface for the Following Book: Astrobiologia, Uma Ciencia Emergente

Since the dawn of civilization, we have beheld at the beauty and wonder of the natural world around us and wondered how it came to be. We have pondered the past, and have been intrigued about the future. For this we are unique. Our ancestors looked to the vastness of space and thought surely there are others out there. We are now at a new time in human history where we can address these age-old questions with a scientific approach and study rigorously the three big questions of astrobiology: Where do we come from? Where are we going? and Are we alone? These fundamental questions of astrobiology correspond to those of humanity, and arguably, what makes us human. And so we cannot help but be drawn to the field. Unlike other scientific disciplines, Astrobiology draws on the latest advances in a multitude of fields, from evolutionary and molecular biology, to prebiotic and interstellar chemistry, from astrophysics to astronomy, with a healthy dose of earth and planetary science. Astrobiology is in reality a "metadiscipline" drawing on useful science wherever it is to be found. From a practical point of view, this endeavor requires the interaction of scientists who might not normally meet each other, much less work on a common research project. And, unlike most other scientific disciplines, Astrobiology has implications for how we see ourselves, and how we interact with the earth and beyond. "Where do we come from" touches on the "why" questions that have intrigued not just scientists but philosophers and theologians. "Where are we going" adds to these an economic and political involvement that is currently being played out with discussions of climate change. "And are we alone" will someday force us to face the fact that we as living creatures are not unique, or perhaps that we are utterly alone in the universe, the result of a chemical history that was so improbable as to result in a sample size of one. Either result will force ethical considerations of either "the other" and their relationship to us, or our solitude and thus responsibility as the only life form in our cosmos. So what is Astrobiology? Let's start with the "Where do we come from?" A biologist will approach this looking at the evolution of life on earth, using such traditional tools as comparative anatomy and paleontology and newer tools such as molecular techniques. But this doesn't address why this happened the way it did without a comprehensive understanding of the environment. What was the temperature at such and such a time? Was the earth in a snowball phase or being bombarded by meteorites -- or even just a single large, well-placed one such as struck off the Yucatan peninsula 65 million years ago. This event could not have been predicted by population genetics alone, yet it had the most profound influence on our evolution as without it, we could still be in a world dominated by dinosaurs with the mammals cowering under cover. But it is not enough to go back to LUCA, the Last Universal Common Ancestor of all extant life. One must go back to the dawn of life. How did life arise? What was the environmental backdrop that allowed it to happen? How did we happen to end up with a habitable planet? Indeed, what is the origin and evolution of our solar system, galaxy, biogenic elements all the way back to the Big Bang. The "Where are we going?" tends to be ignored in many astrobiology programs, but in fact this is of the most immediate importance to us. Whereas the past was dominated by physical and chemical processes, and organismal interactions, the future has a new major player: us. While we probably don't have the power (yet) to stop our galaxy passing through another, or even reset the sun or stop the movement of the moon away from the earth, all of these things will influence the future of life on earth. We are already proving that we have the power to visit other bodies in our solar system, either with humans or our robotic surrogates. We are changing our atmospheric composition and thus our climate. We have the power to render species extinct, including our own. But we also have the power to use these tools for the common good, to extend our lifetimes and reclaim our rivers and forests. Which will it be? And then there is the question where science fiction becomes a reality: "Are we alone?" While many people are anxious to find signs of intelligent life out there, such a creature may not share either our curiosity or values. But what if there was a beneficent alien civilization that could communicate with us, perhaps forging a mutual understanding? More likely in the forseeable future is finding a small life, less evolved, life form. Note I did not use the word "simple" as there is nothing "simple" about life, ever. Which brings us back to the question: what is life? So where does Brazil come in? For nearly a decade there has been interest in a Brazilian astrobiology program, from a small side meeting held by the Brazilian Exobiology Program (BEP) of the Brazilian National Research Council, held in Rio de Janeiro, Brazil, on August 12, 2009, in association with the IAU Assembly to subsequent workshops held in several locations and membership of the Brazilian program in the NASA Astrobiology Institute (NAI). Each time I go to Brazil, I am impressed by the enthusiasm of the community, both scientific and student, the latter an excellent omen for the future of astrobiology in Brazil. Facilities are being built to supplement the natural laboratories that Brazil is blessed to have. In my own lab I have been privileged to have a wonderful Brazilian postdoctoral fellow, Dr. Ivan Paulino-Lima, resulting in a daily reminder of the program. I am honored to have been part of the development of astrobiology in Brazil, and hope that this relationship will continue to flourish. Clearly to advance astrobiology needs new knowledge, a reorganization of that which is known, and space missions. To help the reader join on this quest, what follows is a buffet of topics that will allow the reader to nibble on the richness that is Astrobiology. And, like a fabulous meal, it should make you want more. Welcome to Astrobiology.

Are we alone?↗

Alkali Halide Microstructured Optical Fiber for X-Ray Detection

Microstructured optical fibers containing alkali halide scintillation materials of CsI(Na), CsI(Tl), and NaI(Tl) are presented. The scintillation materials are grown inside the microstructured fibers using a modified Bridgman-Stockbarger technique. The x-ray photon counts of these fibers, with and without an aluminum film coating are compared to the output of a collimated CdTe solid state detector over an energy range from 10 to 40 keV. The photon count results show significant variations in the fiber output based on the materials. The alkali halide fiber output can exceed that of the CdTe detector, dependent upon photon counter efficiency and fiber configuration. The results and associated materials difference are discussed.

DeHaven, S. L.↗

Transient Astrophysics Probe: White Paper

The Transient Astrophysics Probe (TAP) is a wide-field multi-wavelength transient mission proposed for flight starting in the late 2020s. The mission instruments include unique ``Lobster-eye'' imaging soft X-ray optics that allow an approximately 1600-degrees-squared Field of View (FoV); a high sensitivity, 1-degree-squared FoV soft X-ray telescope; a 1-degree-squared FoV Infrared telescope with bandpass 0.6 to 3 microns; and a set of 8 NaI gamma-ray detectors. TAP's most exciting capability will be the observation of tens per year of X-ray and Infrared counterparts of gravitational waves (GWs) involving stellar-mass black holes and neutron stars detected by LIGO (Laser Interferometer Gravitational-Wave Observatory ) / Virgo / KAGRA (Kamioka (Japan) Gravitational Wave Detector) / LIGO-India, and possibly several per year X-ray counterparts of GWs from supermassive black holes, detected by LISA (Laser Interferometer Space Antenna) and Pulsar Timing Arrays. TAP will also discover hundreds of X-ray transients related to compact objects, including tidal disruption events, supernova shock breakouts, and Gamma-Ray Bursts from the epoch of reionization.

Camp, Jordan↗

Detecting Low-level Radiation Sources Using Border Monitoring Gamma Sensors

We consider a problem of detecting a low-level radiation source using a network of Gamma spectral sensors placed on the periphery of a monitored region. We propose a computationally light-weight, correlation-based method which is primarily intended for systems with limited computing capacity. Sensor measurements are combined at the fusion by first generating decisions at each time step and then taking their majority vote within a time widow. At each time step, decisions are generated using two strategies: (i) SUM method based on a threshold decision on a correlation statistic derived from measurements from all sensors, and (ii) OR method based on logical-OR of threshold decisions based on correlations statistics of individual sensor measurements. We derive analytical performance bounds for false alarm rates of SUM and OR methods, and show that their performance is enhanced by the temporal smoothing of majority vote within a time window. Using measurements from a test campaign, we generate a border monitoring scenario with twelve 2"x2" NaI Gamma sensors deployed on the periphery of 42m x 42m outdoor region. A Cs-137 source is moved in a straight-line across this region, starting several meters outside and finally moving away from it. We illustrate the performance of both correlation-based detection methods, and compare their performances with each other and with a particle filter method. Overall, under small false-alarm conditions, the OR fusion is found to produce better detection performance.

Sen, Satyabrata↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

Engineering - Instrumentation related to nuclear s↗

Gamma Spectroscopy

Gamma Spectroscopy, or the identification of radio-isotopes based on energy, is extraordinarily useful in the Nuclear field. High Purity German (HPGe) gamma detectors along with Sodium Iodine (NaI) gamma detectors are commonly used to identify possible contamination and determine enrichments, among many other applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On Feature, Classifier and Detector Fusers for U-235 Signatures Using Gamma Spectral Counts

Three types of information fusion strategies are studied to assess the performance of classifiers for detecting low-level U-235 radiation sources, using features obtained from gamma spectra of NaI detectors. These three strategies are based on using two spectral region features, fusing eight classifiers of diverse designs, and fusing multiple detectors located at different positions around the source. The inner, middle and outer groups of detectors, within a formation of two concentric circles and a spiral of 21 detectors, are identified based on their distance to the source, which is located at the center. This study provides two main qualitative insights into this classification task. First,the fusion of detectors leads to an overall improved classification performance, least in the inner group, most in the outer group, and in between for the middle group. Second, several classifiers and fusers achieve lower training error which does not translate to lower generalization error, indicating their over-fitting to training data.

Rao, Nageswara↗

Selection of Training Sets for 235U Source Detection Classifiers Using Gamma Signatures

The machine learning methods for classifiers to detect low level radiation sources are of interest when suitable training data sets are available. Their application and performance assessment, however, involves the aspects of over-fitting and training data selection that are somewhat uncommon in other existing methods for this task.We study U-235 gamma signatures using data sets collected by 21 NaI detectors under controlled conditions. The gamma spectra are collected by the detectors located at different distances from the source, and we study their choice as training sets for classifiers to detect a source. The detectors form the near, middle and outer groups based on the distance to source. The classifiers based on the outer group are susceptible to over-fitting, that is, they achieve low training error but incur much higher testing error in independent tests. The other two groups achieve lower training error and comparable testing error, and the near group achieves the overall lowest error. In detecting a source at an unknown distance, the farther detectors in the middle group achieve the overall lowest testing error with limited over-fitting, thereby indicating the complex dependencies between the training and classifier performance.

Rao, Nageswara↗

Tracking Radioactive Isotopes in HVAC and Application for Hot Cell Analyses - 20155

In recent years, the surge in the number of isotope production facilities under design has increased the need to analyze isotope migration in facility Heating, Ventilation, and Air Conditioning (HVAC) during normal operations and accident scenarios. These facilities are used to produce isotopes for medical, security, and industrial applications and as such are subject to license and regulatory requirements 10CFR20, 10CFR30, 10CFR50, and 10CFR70. GOTHIC, a general-purpose thermal-hydraulics software package, includes the ability to model isotopic tracers, radioactive decay and isotope migration as well as HEPA and charcoal filters for isotope retention. A GOTHIC model was developed by Zachry Nuclear Engineering (ZNE) to examine the effect of negative room pressure, HEPA filtration, and HVAC fluctuations on radiation areas, hot cells and gloveboxes. Radioactive tracers were used to simulate the concentration of spills within contaminated areas, track the migration of isotopes of interest, and determine the isotopic retention and buildup on facility HEPA filters. A variety of isotopes with concern to dose (e.g., Kr-85, Sr-90, I-131, etc.), including their decay and progeny, are included in the analysis. Negative pressures are maintained in the regions of interest by a representative central HVAC system equipped with a volumetric fan that exhausts to the environment after a series of isolation valves and HEPA filters. GOTHIC is an industry trusted tool for providing engineering solutions for a variety of applications, including fission product tracking, aerosol and particulate transport and ventilation assessments. The software provides an integrated analysis environment that includes a graphical user interface (GUI) for constructing analysis models, a numerical solver that includes parallel processing capabilities and a post-processor for evaluating simulation results. It solves the conservation equations for mass, momentum and energy for multicomponent, multi-phase flow in lumped parameter and multi-dimensional geometries (1, 2, or full 3D), including the effects of turbulence, diffusion and buoyancy. It has been developed and maintained under a Quality Assurance program in compliance with the requirements of 10CFR50 Appendix B and applicable portions of ASME NQA-1 since 1995. GOTHIC has been used for assessing both forced and natural convection conditions for a wide range of applications, including: - Tracking concentration of hazardous gases and chemicals for habitability and safety assessments - Determining ventilation and filtration requirements and optimizing location and arrangement of these systems - Room heat-up, including diverse and Flexible coping strategies for Extended Loss of AC Power (FLEX/ELAP) - Equipment Qualification (EQ) A distinctive feature of GOTHIC is the ability to track many different fields/substances in a simulation, including user defined tracer elements, in the liquid, vapor and droplet fields as well as surfaces and filters. This capability allows GOTHIC to model fission product transport and release or the removal of particulates or harmful toxins from exhaust gases using a spray scrubber or other types of filtration systems. GOTHIC also includes models for engineered equipment, such as fans, filters, charcoal filters, dryers/demisters, dampers, etc. The aerosols and other filtered material are removed or accumulated in these components. The range of aerosol and radiological applications that GOTHIC has been used for includes: - Source Term: Primary Coolant (Equilibrium) Activity; Non-Water Coolant Source/Leakage. - Conditions for Iodine Re-evolution: Sump/Suppression Pool Conditions and pH; - RWST Conditions and pH. - Isotope Removal Mechanisms: Containment Sprayed and Unsprayed Region Mixing; Charcoal Filter Heating due to Iodine decay. - Radionuclide Transport and Decay: Post-LOCA Release in containment; Transport between connected Compartments and vent systems; Groundwater transport of radionuclides. - Non-Newtonian Fluid modeling for sludge, waste tanks, etc. ADAMS ML071581053 (titled 'Best Practice Guidelines for the use of CFD in Nuclear Reactor Safety Applications') poses guidelines for applying single phase CFD codes in nuclear reactor safety problems and GOTHIC is listed as a 'tool for 3D flows' and 'dispersal and deposition of radionuclides.' The Nuclear Quality Assurance (NQA) pedigree of GOTHIC is an important aspect for applications in the nuclear industry. The fundamental tracer models (convective transport, molecular and turbulent diffusion, removal mechanisms, etc.) have been verified using analytical solutions and validated against applicable separate effects tests. Also, GOTHIC has been benchmarked to many integrated effects tests, including Phebus FP (Fission Product). GOTHIC gives good agreement for the buildup and decay of fission products in Phebus Test 3. The model developed by ZNE demonstrates GOTHIC's applicability and acceptability for use in analyzing the migration and retention of radioactive isotopes and their progeny in normal operation and accident scenario analyses for isotope production facilities, hot cells, and gloveboxes. The tracer activities calculated by GOTHIC can then be used in downstream radiation transport and shielding codes like RADTRAD-NAI{sup C}, MCNP{sup R}, and MicroShield{sup R} to determine on-site and of-site doses. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Scintillating Crystal for High Energy Radiation Detection and Applications

Cesium Hafnium Chloride (Cs2Hfl6) is a promising metal halide scintillating detector due to its excellent characteristics such as non-hygroscopicity, high light yield without doping. Scintillators plays an important role in nuclear security applications as detectors at border monitoring stations. We grew and characterized CHC crystals to be fabricated for gamma detection. Photoluminescence was performed using the Duetta Fluorescence and Absorbance Spectrometer. The energy response to Cs-137 and Co-60 reference sources was recorded for a representative sodium iodide (NaI) scintillating detector.

Reeder, Angel↗

MEASUREMENT OF THE NEUTRON FLUENCE-RATES IN THE ADVANCED TEST REACTOR

The axial neutron fluence-rate distribution at the Advanced Test Reactor (ATR) is determined using a combination of pure nickel and cobalt-aluminium alloy dosimeter wires. Most irradiation programs at ATR need to know the fast neutron fluence-rate surrounding their experiment to correlate post-irradiation examination results with neutron dose. The activated dosimeter wires, which extend beyond the full fuelled region of the reactor core, are highly radioactive following the full cycle in ATR and must therefore be measured in the ATR canal. The system that is employed for these measurements is mechanical scanning mechanism is used to scan the activated wires across the face of a columnated shield and a NaI detector. This detector is not sufficiently calibrated to provide absolute activity measurements, therefore, the count-rate is recorded and normalized to the highest activity for that wire. Then, an approximately 3-mm long portion of the wire is removed from the highest activity region in the wire. The wires are then transferred, and an absolute activity measurement is made using a calibrated ionization chamber. These measurements are combined with corrections for decay, neutron energy spectrum, burnup, dosimeter composition, reactor power fluctuations, and reactor outages to determine the average axial neutron fluence-rate at various locations within ATR during the cycle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Low temperature sodium battery comprising an electrochemically active molten inorganic catholyte

A high-performance electrochemically active sodium molten salt catholyte enables a dramatic reduction in molten sodium battery operating temperature from near 300° C. to less than 120° C. As an example, stable electrochemical cycling was demonstrated in a high voltage (3.65 V) sodium battery comprising a sodium iodide-gallium chloride (NaI—GaCl 3 ) molten salt catholyte for over 8 months at 110° C. The combination of high voltage, stable cycling behavior, and practical current densities supported by a molten catholyte enables a new generation of transformative high performance, low temperature molten sodium batteries.

Spoerke, Erik D.↗

Spectra-to-exposure conversion using polynomial response models for gamma-ray field characterization

Accurate measurement of exposure rate from gamma-ray spectral data remains a critical challenge during radiological emergency response operations. Conventional methods rely on pre-defined static conversion factors derived from fixed geometries and isotopic compositions, which often fail to capture real-world environmental variability. This study presents a generalized approach as a "next-step" for converting gamma-ray spectral data into exposure rate using polynomial response models. The method introduces a flexible weighting scheme based on the in-situ detector response to distributed sources, enabling a pathway towards improved correspondence between measured spectra and "ground-truth" exposure rates. Experimental data from sodium iodide NaI(Tl) detectors were used to validate the approach as, at least equivalent to the current count-to-exposure method employed in emergency response CONOPS. Results show that the polynomial weighting model is sufficiently equal to the count-to-exposure method and may help improve accuracy given its adaptability to real-world conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Peering down the barrel with DESI DR2: 10 000+ inflows at $z$ < 0.6 reveal how galaxies accrete cold gas

Direct observational constraints on how galaxies acquire their gas remain remarkably limited, hindering our understanding of the baryon cycle. We present a search for down-the-barrel NaI D absorption towards 15.6 million galaxies at $z < 0.6$ in DESI Data Release 2. We use Bayesian evidence ratios to assess whether the absorption requires additional components tracing interstellar gas distinct from the systemic component of the galaxy. We construct a catalogue of 50 088 (27 420) galaxies with moderate (strong) evidence for down-the-barrel absorption. The inferred absorption components are broadly distributed in velocity, with approximately 50% at $v_{\rm flow} < -50$ km/s, 30% within 50 km/s of the systemic velocity and the remaining 20% at $v_{\rm flow} > 50$ km/s. We find strong evidence for a large population of low-velocity, infalling absorbers with velocities $\sim$20 km/s in edge-on galaxies, consistent with radial inflows predicted in simulations. The stronger correlation in early-type galaxies between inflow velocity and stellar velocity dispersion, compared to that with stellar mass, suggests that a portion of these inflows may be associated with accreting satellites. These results reveal the multiple pathways in which galaxies accrete gas at redshift $z < 0.6$ for the first time in a statistically significant sample.

Weng, S. [Marseille, Lab. Astrophys.]↗