Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NOISE ATTENUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Generalized wave envelope analysis of sound propagation in ducts with stepped noise source profiles and variable axial impedance

A finite difference formulation is presented for sound propagation in a rectangular two-dimensional duct without steady flow. Before the difference equations are formulated, the governing Helmholtz equation is first transformed to a form whose solution tends not to oscillate along the length of the duct. This transformation reduces the required number of grid points by an order of magnitude. Example solutions indicate that stepped noise source profiles have much higher attenuation than plane waves in a uniform impedance liner. Also, multiple stepped impedance liners are shown to have higher attenuation than uniform ducts if the impedances are chosen properly. For optimum noise reduction with axial variations in impedance, the numerical analysis indicates that for a plane wave input the resistance should be near zero at the entrance of a suppressor duct, while the reactance should be near the optimum value associated with the least-attenuated mode in a uniform duct.

Baumeister, K. J.↗

Investigation of Fourth-leg for Common-mode Noise Reduction in Three-level Neutral Point Clamped Inverter Fed Motor Drive

The four-leg topology has been applied to two-level inverters for common-mode (CM) noise elimination. To achieve zero common-mode voltage (CMV), the zero vector typically used in the two-level inverter is not allowed. As a result, the reference cannot be synthesized by nearest three vectors, which introduces a penalty in dc voltage utilization and current THD. This paper applies the fourth-leg to three-level neutral point clamped (NPC) inverter fed motor drives. Unlike the case in the two-level inverter, the reference can be synthesized by the nearest three vectors while zero CMV can be achieved at the same time in a three-level inverter with the fourth-leg. The topology and modulation are presented. The fourth-leg filter structures are investigated, and a fourth-leg filter structure which decouples the fourth-leg from the main circuit power level is proposed for high power applications. The experiment results on a three-level NPC inverter show that with the fourth-leg and presented modulation applied, the CM noise has been significantly reduced, and around 25 dB attenuation can be observed at the first noise peak in the electromagnetic interference (EMI) frequency range.

Chen, Ruirui↗

Linking international technical specifications for acoustic characterization of marine energy converter sounds with environmental compliance criteria

As new ocean energy technologies emerge and are deployed for testing and operations, sound emissions are a potential concern for environmental effects to marine life. Consistent acoustic measurement and data analysis methods can help promote comparisons of technologies and transferability between project sites. In 2022, acoustic emissions from a prototype scale wave energy converter (WEC) were characterized for a range of environmental conditions and power generation states in the coastal waters off southern California using a set of international technical specifications. Results from the international technical specification analyses were applied to United States regulatory threshold criteria for acoustic impacts to marine mammals and examined in the context of European underwater noise monitoring guidelines. Weighted 24 hour cumulative sound exposure levels SEL24h calculated from the highest power generation state WEC sound pressure levels were often more than 20 dB below threshold criteria for temporary threshold shifts in five relevant marine mammal hearing groups. Following European Union recommendations for analyses and reporting, WEC sound characterization in third octave bands centered at 63 Hz and 125 Hz show clear spatial decay of WEC-generated noise, with more pronounced attenuation at 63 Hz, and a less marked but still detectable gradient at 125 Hz, collectively suggesting a relatively confined acoustic footprint under the observed conditions. The value of the international technical specification approach is highlighted by the isolation of WEC sounds from the surrounding soundscape. This allows for a robust characterization of acoustic emissions through a range of device power generation and sea states. Furthermore, in threshold-based regulatory contexts like the U.S., this facilitates direct evaluation of source contributions, while in broader monitoring frameworks used in the E.U. it provides a reproducible foundation for assessing the contribution of emerging ocean energy technologies to the underwater acoustic environment.

Haxel, Joseph H. (ORCID:0000000273864761)↗

Virtual ultrasound sources for inspecting nuclear components of coarse-grained structure

This work describes an ultrasonic inspection procedure designed for verifying coarse-grained structure materials, which are commonly used on nuclear reactors. In this case, conventional phased array techniques cannot be used due to attenuating characteristics and backscattered noise from microstructures inside the material. Thus, synthetic aperture ultrasonic imaging (SAFT) is used for this approach in contact conditions. In order to increase energy transferred to the medium, synthetic transmit aperture is formed by several elements which generate a diverging wavefront equivalent to a virtual ultrasound source behind the transducer. On the other hand, the phase coherence technique has been applied to reduce more structural noise and improve the image quality. The beamforming process has been implemented over a GPU platform to reduce computing time.

42 ENGINEERING↗

Anomaly Detection in Liquid Sodium Cold Trap Operation with Multisensory Data Fusion Using Long Short-Term Memory Autoencoder

Sodium-cooled fast reactors (SFR), which use high temperature fluid near ambient pressure as coolant, are one of the most promising types of GEN IV reactors. One of the unique challenges of SFR operation is purification of high temperature liquid sodium with a cold trap to prevent corrosion and obstructing small orifices. We have developed a deep learning long short-term memory (LSTM) autoencoder for continuous monitoring of a cold trap and detection of operational anomaly. Transient data were obtained from the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The cold trap purification at METL is monitored with 31 variables, which are sensors measuring fluid temperatures, pressures and flow rates, and controller signals. Loss-of-coolant type anomaly in the cold trap operation was generated by temporarily choking one of the blowers, which resulted in temperature and flow rate spikes. The input layer of the autoencoder consisted of all the variables involved in monitoring the cold trap. The LSTM autoencoder was trained on the data corresponding to cold trap startup and normal operation regime, with the loss function calculated as the mean absolute error (MAE). The loss during training was determined to follow log-normal density distribution. During monitoring, we investigated a performance of the LSTM autoencoder for different loss threshold values, set at a progressively increasing number of standard deviations from the mean. The anomaly signal in the data was gradually attenuated, while preserving the noise of the original time series, so that the signal-to-noise ratio (SNR) averaged across all sensors decreased below unity. Results demonstrate detection of anomalies with sensor-averaged SNR < 1.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Centimeter and millimeter wave attenuation and brightness temperature due to atmospheric oxygen and water vapor

Calculations are presented for atmospheric absorption and radiation emission for several atmospheric conditions and elevation angles. The calculations are for frequencies in the 1 to 340 GHz frequency range. The calculations are compared to those from other models. Agreement is found to within 15% for absorption coefficient (7.5 g/m/cubed water vapor at 290 K) and approximately the same for total zenithal attenuation. The attenuation and gaseous emission noise curves defined by the International Radio Consultative Committee are found to have minor inconsistencies.

Smith, E. K.↗

DSN 70-meter antenna X- and S-band calibration. Part 2: System noise temperature measurements and telecommunications link evaluation

The X- and S-band system operating noise temperatures of the Deep Space Network (DSN) 70-m antennas are presented. Models of atmosphere and ground noise temperature contributions, as they affect the antenna calibrations, are given for future use in telecommunications link modeling. The measured 70-m antenna network gain/system noise temperature (G/T) performance is presented. Compared with the earlier 64-m antenna network, G/T improvements of from 1.8 dB to 2.5 dB, depending on elevation angle, were achieved. G/T comparisons are made with the DSN/Flight Project Design Handbook and the Voyager telecommunications design control table. Actual Voyager telecommunications link performance is compared with predictions made by TPAP (the Voyager telecommunications prediction and analysis program) and with measured performance of the individual 70-m antennas. A modification in the use of antenna gain, system noise temperature, and atmospheric attenuation in existing telecommunications design control tables is suggested.

Slobin, S. D.↗

Potential reduction of en route noise from an advanced turboprop aircraft

When the en route noise of a representative aircraft powered by an eight-blade SR-7 propeller was previously calculated, the noise level was cited as a possible concern associated with the acceptance of advanced turboprop aircraft. Some potential methods for reducing the en route noise were then investigated and are reported. Source noise reductions from increasing the blade number and from operating at higher rotative speed to reach a local minimum noise point were investigated. Greater atmospheric attenuations for higher blade passing frequencies were also indicated. Potential en route noise reductions from these methods were calculated as 9.5 dB (6.5 dB(A)) for a 10-blade redesigned propeller and 15.5 dB (11 dB(A)) for a 12-blade redesigned propeller.

Dittmar, James H.↗

CCSDS Link Budget Weather Related Losses

The following paper describes the method used in computation of weather-related losses, namely the atmospheric attenuation and the system noise temperature increase due to weather.

NASA/JPL/DSN tracking stations CCSDS link budget p↗

Optimum design of structures of composite materials in response to aerodynamic noise and noise transmission

Elastic wave propagation and attenuation in a model fiber matrix was investigated. Damping characteristics in graphite epoxy composite materials were measured. A sound transmission test facility suitable to incorporate into NASA Ames wind tunnel for measurement of transmission loss due to sound generation in boundary layers was constructed. Measurement of transmission loss of graphite epoxy composite panels was also included.

Yang, J. C. S.↗

Ultrasonic correlator versus signal averager as a signal to noise enhancement instrument

Ultrasonic inspection of thick and attenuating materials is hampered by the reduce amplitudes of the propagated waves to a degree that the noise is too high to enable meaningful interpretation of the data. In order to overcome the low signal to noise ratio (S/N), a correlation technique has been developed. In this method, a continuous pseudo-random pattern generated digitally is transmitted and detected by piezoelectric transducers. A correlation is performed in the instrument between the received signal and a variable delayed image of the transmitted one. The result is shown to be proportional to the impulse response of the investigated material, analogous to a signal received from a pulsed system, with an improved S/N ratio. The degree of S/N enhancement depends on the sweep rate. The correlator is described, and it is compared to the method of enhancing S/N ratio by averaging the signals. The similarities and differences between the two are highlighted and the potential advantage of the correlator system is explained.

Kishoni, Doron↗

Ultrasonic correlator versus signal averager as a signal to noise enhancement instrument

Ultrasonic inspection of thick and attenuating materials is hampered by the reduced amplitudes of the propagated waves to a degree that the noise is too high to enable meaningful interpretation of the data. In order to overcome the low Signal to Noise (S/N) ratio, a correlation technique has been developed. In this method, a continuous pseudo-random pattern generated digitally is transmitted and detected by piezoelectric transducers. A correlation is performed in the instrument between the received signal and a variable delayed image of the transmitted one. The result is shown to be proportional to the impulse response of the investigated material, analogous to a signal received from a pulsed system, with an improved S/N ratio. The degree of S/N enhancement depends on the sweep rate. This paper describes the correlator, and compares it to the method of enhancing S/N ratio by averaging the signals. The similarities and differences between the two are highlighted and the potential advantage of the correlator system is explained.

Kishoni, Doron↗

Dual energy CT for attenuation correction with PET/CT

Purpose: The authors evaluate the energy dependent noise and bias properties of monoenergetic images synthesized from dual-energy CT (DECT) acquisitions. These monoenergetic images can be used to estimate attenuation coefficients at energies suitable for positron emission tomography (PET) and single-photon emission computed tomography (SPECT) imaging. This is becoming more relevant with the increased use of quantitative imaging by PET/CT and SPECT/CT scanners. There are, however, potential variations in the noise and bias of synthesized monoenergetic images as a function of energy. Methods: The authors used analytic approximations and simulations to estimate the noise and bias of synthesized monoenergetic images of water-filled cylinders with different shapes and the NURBS-based cardiac-torso (NCAT) phantom from 40 to 520 keV, the range of SPECT and PET energies. The dual-kVp spectra were based on the GE Lightspeed VCT scanner at 80 and 140 kVp with added filtration of 0.5 mm Cu. The authors evaluated strategies of noise suppression with sinogram smoothing and dose minimization with reduction of tube currents at the two kVp settings. The authors compared the impact of DECT-based attenuation correction with single-kVp CT-based attenuation correction on PET quantitation for the NCAT phantom for soft tissue and high-Z materials of bone and iodine contrast enhancement. Results: Both analytic calculations and simulations displayed the expected minimum noise value for a synthesized monoenergetic image at an energy between the mean energies of the two spectra. In addition the authors found that the normalized coefficient of variation in the synthesized attenuation map increased with energy but reached a plateau near 160 keV, and then remained constant with increasing energy up to 511 keV and beyond. The bias was minimal, as the linear attenuation coefficients of the synthesized monoenergetic images were within 2.4% of the known true values across the entire energy range. Compared with no sinogram smoothing, sinogram smoothing can dramatically reduce noise in the DECT-derived attenuation map. Through appropriate selection of tube currents for high and low kVp scans, DECT can deliver roughly the same amount of radiation dose as that of a single kVp CT scan, but could be used for PET attenuation correction with reduced bias in contrast agent regions by a factor of ∼2.6 and slightly reduced RMSE for the total image. Conclusions: When DECT is used for attenuation correction at higher energies, there is a noise amplification that is dependent on the energy of the synthesized monoenergetic image of linear attenuation coefficients. Sinogram smoothing reduces the noise amplification in DECT-derived attenuation maps without increasing bias. With an appropriate selection of CT techniques, a DECT scan with the same radiation dose as a single CT scan can result in a PET image with improved quantitative accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fluid shielding of high-velocity jet noise

Experimental noise data for a nozzle exhaust system incorporating a thermal acoustic shield (TAS) are presented to show the effect of changes in geometric and flow parameters on attenuation of high-velocity jet exhaust noise in the flyover plane. The results are presented for a 10.00-cm-diameter primary conical nozzle with a TAS configuration consisting of a 2.59- or 5.07-cm-wide annular gap. Shield-stream exhaust velocity was varied from 157 to 248 m/sec to investigate the effect of velocity ratio. The results showed that increasing the annular gap width increases attenuation of high-frequency noise when comparisons are made on the same ideal thrust basis. Varying the velocity ratio had a minor effect on the noise characteristics of the nozzles investigated.

Goodykoontz, J. H.↗

Effect of helicopter noise on passenger annoyance

The effects of helicopter interior noise on passenger annoyance for both reverie and listening situations was investigated. The relative effectiveness of several metrics for quantifying annoyance response for these situations was also studied. The noise stimuli were based upon recordings of the interior noise of civil helicopter research aircraft. These noises were presented at levels ranging from approximately 70 to 86 d with various tonal components selectively attenuated to give a range of spectra. The listening task required the subjects to listen to and record phonetically-balanced words presented within the various noise environments. Results indicate that annoyance during a listening condition is generally higher than annoyance under a reverie condition for corresponding interior noise environments. Attenuation of the tonal components results in increases in listening performance but has only a small effect upon annoyance for a given noise level.

Clevenson, S. A.↗