Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NODES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Direct formulation of a 4-node hybrid shell element with rotational degrees of freedom

A simple 4-node assumed-stress hybrid quadrilateral shell element with rotational or drilling degrees of freedom is formulated. The element formulation is based directly on a 4-node element. This direct formulation requires fewer computations than a similar element that is derived from an internal 8-node isoparametric element in which the midside degrees of freedom are eliminated in favor of rotational degree of freedom at the corner nodes. The formulation is based on the principle of minimum complementary energy. The membrane part of the element has 12 degrees of freedom including rotational degrees of freedom. The bending part of the element also has 12 degrees of freedom. The bending part of the quadratic variations for both in-plane and out-of-plane displacement fields and linear variations for both in-plane and out-of-plane rotation fields are assumed along the edges of the element. The element Cartesian-coordinate system is chosen such as to make the stress field invariant with respect to node numbering. The membrane part of the stress field is based on a 9-parameter equilibrating stress field, while the bending part is based on a 13-parameter equilibrating stress field. The element passes the patch test, is nearly insensitive to mesh distortion, does not lock, possesses the desirable invariance properties, has no spurious modes, and produces accurate and reliable results.

Aminpour, Mohammad A.↗

ECLSS Design for the International Space Station Nodes 2 and 3

The International Space Station (ISS) modules Nodes 2 and 3 are currently under development by Alenia Spazio and the Marshall Space Flight Center (MSFC). The design of the Environmental Control and Life Support Systems (ECLSS) for these two modules have some similarities but many differences. The Node 2 ECLSS provides inter- and intramodule ventilation, temperature and humidity control, fire detection and suppression, and distribution of atmosphere samples, low pressure and recharge oxygen and nitrogen, fuel cell water and wastewater. Design Review 1 was held in March 1998. Fabrication of the ducting, tubing, and support structure is ongoing with Design Review 2 planned for December 1999. In addition to providing the same functions as Node 2, the ECLSS for Node 3 includes carbon dioxide removal, trace contaminant control, atmosphere monitoring, atmosphere pressure control, oxygen generation, urine and potable water processing, waste management, and potable water distribution to support the habitability functions relocated from the U.S. Hab module. Scarring for future incorporation of carbon dioxide reduction is also included. Design Review 1 is planned for July 1999. An overview of each Node's system design as well as issues and challenges are discussed.

Carrasquillo, Robyn L.↗

Connecting Node

A paper describes the Octanode, a connecting node that facilitates the integration of multiple docking mechanisms, hatches, windows, and internal and external systems with the use of flat surfaces. The Octanode is a 26- faced Great Rhombicuboctahedron Archi medean solid with six octagonshaped panels, eight hexagon-shaped panels, and 12 square panels using three unique, simple, flat shapes to construct a spherical approximation. Each flat shape can be constructed with a variety of material and manufacturing techniques, such as honeycomb composite panels or a pocketed skinstringer configuration, using conventional means. The flat shapes can be connected together and sealed to create a pressurizable volume by the use of any conventional means including welding or fastening devices and sealant. The node can then be connected to other elements to allow transfer between those elements, or it could serve as an airlock. The Octanode can be manufactured on the ground and can be integrated with subsystems including hatches and ports. The node can then be transported to its intended location, whether on orbit or on surface. Any of the flat panels could be replaced by curved ones, turning the node into a copula. Windows may be placed on flat panes with optimal viewing angles that are not blocked by large connecting nodes. The advantage of using flat panels to represent a spherical approximation is that this allows for easier integration of subsystems and design features.

Johnson, Christopher J.↗

Expandable and reconfigurable instrument node arrays

An expandable and reconfigurable instrument node includes a feature detection means and a data processing portion in communication with the feature detection means, the data processing portion configured and disposed to process feature information. The instrument node further includes a phase locked loop (PLL) oscillator in communication with the data processing portion, the PLL oscillator configured and disposed to provide PLL information to the processing portion. The instrument node further includes a single tone transceiver and a pulse transceiver in communication with the PLL oscillator, the single tone transceiver configured and disposed to transmit or receive a single tone for phase correction of the PLL oscillator and the pulse transceiver configured and disposed to transmit and receive signals for phase correction of the PLL oscillator. The instrument node further includes a global positioning (GPA) receiver in communication with the processing portion, the GPS receiver configured and disposed to establish a global position of the instrument node.

Hilliard, Lawrence M.↗

Preliminary Node Separation Orbit Determination Analysis for the HelioSwarm Observatory

The HelioSwarm Observatory is a nine-spacecraft swarm design, consisting of one Hub and eight Node spacecraft co-orbiting the Earth in a ~13.7-day orbit. Each Node separates from the Hub during the Node Commissioning Phase, and the Nodes’ sole source of tracking is inter-satellite relative ranging with the Hub. This study characterizes how soon the relative ranging should occur post-separation to maintain a reasonable knowledge of the Nodes’ position relative to the hub and quantifies how often, and at what measurement cadence, relative ranging needs to occur during the early days of commissioning.

orbit determination↗

Method and apparatus for analyzing error conditions in a massively parallel computer system by identifying anomalous nodes within a communicator set

An analytical mechanism for a massively parallel computer system automatically analyzes data retrieved from the system, and identifies nodes which exhibit anomalous behavior in comparison to their immediate neighbors. Preferably, anomalous behavior is determined by comparing call-return stack tracebacks for each node, grouping like nodes together, and identifying neighboring nodes which do not themselves belong to the group. A node, not itself in the group, having a large number of neighbors in the group, is a likely locality of error. The analyzer preferably presents this information to the user by sorting the neighbors according to number of adjoining members of the group.

97 MATHEMATICS AND COMPUTING↗

Reducing power consumption during execution of an application on a plurality of compute nodes

Methods, apparatus, and products are disclosed for reducing power consumption during execution of an application on a plurality of compute nodes that include: executing, by each compute node, an application, the application including power consumption directives corresponding to one or more portions of the application; identifying, by each compute node, the power consumption directives included within the application during execution of the portions of the application corresponding to those identified power consumption directives; and reducing power, by each compute node, to one or more components of that compute node according to the identified power consumption directives during execution of the portions of the application corresponding to those identified power consumption directives.

97 MATHEMATICS AND COMPUTING↗

Thread selection according to predefined power characteristics during context switching on compute nodes

Methods, apparatus, and products are disclosed for thread selection during context switching on a plurality of compute nodes that includes: executing, by a compute node, an application using a plurality of threads of execution, including executing one or more of the threads of execution; selecting, by the compute node from a plurality of available threads of execution for the application, a next thread of execution in dependence upon power characteristics for each of the available threads; determining, by the compute node, whether criteria for a thread context switch are satisfied; and performing, by the compute node, the thread context switch if the criteria for a thread context switch are satisfied, including executing the next thread of execution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Profiling an application for power consumption during execution on a compute node

Methods, apparatus, and products are disclosed for profiling an application for power consumption during execution on a compute node that include: receiving an application for execution on a compute node; identifying a hardware power consumption profile for the compute node, the hardware power consumption profile specifying power consumption for compute node hardware during performance of various processing operations; determining a power consumption profile for the application in dependence upon the application and the hardware power consumption profile for the compute node; and reporting the power consumption profile for the application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Profiling an application for power consumption during execution on a plurality of compute nodes

Methods, apparatus, and products are disclosed for profiling an application for power consumption during execution on a compute node that include: receiving an application for execution on a compute node; identifying a hardware power consumption profile for the compute node, the hardware power consumption profile specifying power consumption for compute node hardware during performance of various processing operations; determining a power consumption profile for the application in dependence upon the application and the hardware power consumption profile for the compute node; and reporting the power consumption profile for the application.

97 MATHEMATICS AND COMPUTING↗

Thread selection according to power characteristics during context switching on compute nodes

Methods, apparatus, and products are disclosed for thread selection during context switching on a plurality of compute nodes that includes: executing, by a compute node, an application using a plurality of threads of execution, including executing one or more of the threads of execution; selecting, by the compute node from a plurality of available threads of execution for the application, a next thread of execution in dependence upon power characteristics for each of the available threads; determining, by the compute node, whether criteria for a thread context switch are satisfied; and performing, by the compute node, the thread context switch if the criteria for a thread context switch are satisfied, including executing the next thread of execution.

97 MATHEMATICS AND COMPUTING↗

Pin-pointing Node Failures in HPC Systems

Automated fault prediction and diagnosis in HPC systems needs to be efficient for better system resilience. With increasing scalability required for exascale, accurate fault prediction aiding in quick remedy is hard. With changing supercomputer architectures, distilling fault data from the noisy raw logs requires substantial efforts. Predicting node failures in such voluminous system logs is challenging. To this end, we investigate an interesting way to pin-point node failures in such supercomputing systems. Our study on Cray system data with automated machine learning tools suggests that specific patterns of event messages on node unavailability can be indicator to node failures. This data extraction coupled with system and job data correlation helps in devising a methodology to predict node failures and their location over a specific time frame. This work aims to enable broader applicability for a generic fault prediction framework.

Roman, E↗

CT-Guided Radioactive {sup 125}I Seed Implantation Therapy of Symptomatic Retroperitoneal Lymph Node Metastases

Purpose: This study explored the clinical efficacy of CT-guided radioactive {sup 125}I seed implantation in treating patients with symptomatic retroperitoneal lymph node metastases. Methods: Twenty-five patients with pathologically confirmed malignant tumors received CT-guided radioactive {sup 125}I seed implantation to treat metastatic lymph nodes. The diameter of the metastatic lymph nodes ranged from 1.5 to 4.5 cm. Treatment planning system (TPS) was used to reconstruct the three-dimensional image of the tumor and then calculate the corresponding quantity and distribution of {sup 125}I seeds. Results: Follow-up period for this group of patients was 2–30 months, and median time was 16 months. Symptoms of refractory pain were significantly resolved postimplantation (P < 0.05), and Karnofsky score rose dramatically (P < 0.05). Most patients reported pain relief 2–5 days after treatment. Follow-up imaging studies were performed 2 months later, which revealed CR in 7 patients, PR in 13 patients, SD in 3 patients, and PD in 2 patients. The overall effective rate (CR + PR) was 80 %. Median survival time was 25.5 months. Seven patients died of recurrent tumor; 16 patients died of multiorgan failure or other metastases. Two patients survived after 30 months follow-up. Two patients reported localized skin erythema 1 week postimplantation, which disappeared after topical treatment. Conclusions: CT-guided radioactive {sup 125}I seed implantation, which showed good palliative pain relief with acceptable short-term effects, has proved in our study to be a new, safe, effective, and relatively uncomplicated treatment option for symptomatic retroperitoneal metastatic lymph nodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lymphatic Leak Occurring After Surgical Lymph Node Dissection: A Preliminary Study Assessing the Feasibility and Outcome of Lymphatic Embolization

PurposeTo analyze imaging findings of lymphatic leakage associated with surgical lymph node dissection on lymphangiography and assess the outcome of lymphatic embolization.Materials and MethodsThis retrospective study comprised 21 consecutive patients who were referred for lymphatic intervention between March 2014 and April 2015 due to postsurgical lymphatic leaks. Lymphangiography was performed through inguinal lymph nodes to identify the leak. When a leak was found, lymphatic embolization was performed by fine-needle injection of N-butyl cyanoacrylate into the site of leakage or into an inflow lymphatic vessel or into a pelvic lymph node located below the leakage. Electronic medical records and imaging studies were reviewed to assess the outcome.ResultLymphangiography revealed single or multiple leaks in all but one patient. Lymphatic embolization was performed in 20 patients with leaks. Including the patient who did not undergo embolization, 17 patients (81.0 %) showed initial response to treatment. Three patients underwent repeated embolization with successful results. The overall success rate was 95.2 %. The mean duration of hospitalization after lymphatic intervention was 5.9 days. During a mean follow-up period of 11 months, two patients developed localized swelling in the groin following lipiodol injection. There were no complications related to lymphatic embolization. Three patients were found to have developed small, asymptomatic lymphoceles on CT or MRI that did not require further treatment.ConclusionLymphangiography is useful for detecting lymphatic leakage occurring after lymph node dissection. Furthermore, lymphatic embolization is feasible, effective, and safe for managing leaks demonstrated on lymphangiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Furthering Precision in Sentinel Node Navigational Surgery for Oral Cancer: a Novel Triple Targeting System

To describe an innovative sentinel lymph node (SLN) guidance approach using a radionuclide tracer, 3D augmented reality-guided imaging, and near infrared (NIR) fluorescence over-lay imaging with hand-held probes to optimize accuracy, efficiency, and precise navigation for sentinel node (SN) localization in head and neck cancer. In a cT1N0M0 squamous cell carcinoma of the tongue, pre-operative radionuclide lymphoscintigraphy was performed with a sentinel node-specific radiolabeled tracer. Intraoperatively, a 3D hand-held augmented reality (AR) scanning SPECT probe assessed concordance of the SN with pre-operative SPECT-CT images. The real-time optical video was linked to the SPECT-CT images for added precision. Final guidance to the SN was performed using ICG fluorescence imaging. Dynamic and SPECT-CT showed bilateral lymphatic drainage from the tumor. The 3D hand-held AR SPECT probe SN localization was concordant with pre-operative imaging. The optical video successfully demonstrated the lymphatic drainage in real-time through a unique overlay fluorescence image. The ICG localized to the same nodes identified by both the SPECT-CT and hand-held SPECT images. The use of dual radiation and fluorescence tracers improved SN detection, especially for SN close to the injection site. The hand-held probes allowed the surgeon to dissect continuously, without needing to change tools. The combination of augmented reality, nuclear medicine, and over-lay fluorescence imaging allowed greater accuracy for matching the preoperative imaging with intraoperative identification and precisely guiding the dissection. This method uniquely permitted the surgeon to efficiently dissect the SN with accurate visualization and optimal precision.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-dose Extended-Field Irradiation and High-Dose-Rate Brachytherapy With Concurrent Chemotherapy for Cervical Cancer With Positive Para-Aortic Lymph Nodes

Purpose: To determine the efficacy and toxicity of extended-field radiotherapy (RT) with concurrent platinum-based chemotherapy in patients with uterine cervical carcinoma and positive para-aortic nodes. Methods and Materials: We retrospectively reviewed the results for 33 women with Stage IB-IVB cervical cancer. Each patient had received 59.4 Gy, including a three-dimensional conformal boost to the para-aortic lymph nodes and 41.4-50.4 Gy of external beam radiotherapy to the pelvis. Each patient also underwent six or seven applications of high-dose-rate brachytherapy (median, 5 Gy to point A at each session). Results: The median follow-up period of surviving patients was 39 months. The most common acute toxicity was hematologic, observed in 23 women. Severe acute and late gastrointestinal toxicity was observed in 3 and 4 patients, respectively. More than three-quarters of patients showed a complete response, encompassing the primary mass, metastatic pelvic, and para-aortic lymph nodes. Of the 33 women, 15 had no evidence of disease, 6 had persistent disease, 4 developed in-field failures, and 6 developed distant failures. The 5-year overall and disease-free survival rate was 47% and 42%, respectively. Conclusion: Concurrent chemoradiotherapy with extended-field radiotherapy is feasible in women with uterine cervical carcinoma and positive para-aortic lymph nodes, with acceptable late morbidity and a high survival rate, although it was accompanied by substantial acute toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlation of Point B and Lymph Node Dose in 3D-Planned High-Dose-Rate Cervical Cancer Brachytherapy

Purpose: To compare high dose rate (HDR) point B to pelvic lymph node dose using three-dimensional-planned brachytherapy for cervical cancer. Methods and Materials: Patients with FIGO Stage IB-IIIB cervical cancer received 70 tandem HDR applications using CT-based treatment planning. The obturator, external, and internal iliac lymph nodes (LN) were contoured. Per fraction (PF) and combined fraction (CF) right (R), left (L), and bilateral (Bil) nodal doses were analyzed. Point B dose was compared with LN dose-volume histogram (DVH) parameters by paired t test and Pearson correlation coefficients. Results: Mean PF and CF doses to point B were R 1.40 Gy +- 0.14 (CF: 7 Gy), L 1.43 +- 0.15 (CF: 7.15 Gy), and Bil 1.41 +- 0.15 (CF: 7.05 Gy). The correlation coefficients between point B and the D100, D90, D50, D2cc, D1cc, and D0.1cc LN were all less than 0.7. Only the D2cc to the obturator and the D0.1cc to the external iliac nodes were not significantly different from the point B dose. Significant differences between R and L nodal DVHs were seen, likely related to tandem deviation from irregular tumor anatomy. Conclusions: With HDR brachytherapy for cervical cancer, per fraction nodal dose approximates a dose equivalent to teletherapy. Point B is a poor surrogate for dose to specific nodal groups. Three-dimensional defined nodal contours during brachytherapy provide a more accurate reflection of delivered dose and should be part of comprehensive planning of the total dose to the pelvic nodes, particularly when there is evidence of pathologic involvement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Does Lymphovascular Invasion Predict Regional Nodal Failure in Breast Cancer Patients With Zero to Three Positive Lymph Nodes Treated With Conserving Surgery and Radiotherapy? Implications for Regional Radiation

Purpose: To examine the relationship between lymphovascular invasion (LVI) and regional nodal failure (RNF) in breast cancer patients with zero to three positive nodes treated with breast-conservation therapy (BCT). Methods and Materials: The records of 1,257 breast cancer patients with zero to three positive lymph nodes were reviewed. All patients were treated with BCT at Massachusetts General Hospital from 1980 to December 2003. Lymphovascular invasion was diagnosed by hematoxylin and eosin-stained sections and in some cases supported by immunohistochemical stains. Regional nodal failure was defined as recurrence in the ipsilateral supraclavicular, axillary, or internal mammary lymph nodes. Regional nodal failure was diagnosed by clinical and/or radiologic examination. Results: The median follow-up was 8 years (range, 0.1-21 years). Lymphovascular invasion was present in 211 patients (17%). In univariate analysis, patients with LVI had a higher rate of RNF (3.32% vs. 1.15%; p = 0.02). In multivariate analysis, only tumor size, grade, and local failure were significant predictors of RNF (p = 0.049, 0.013, and 0.0001, respectively), whereas LVI did not show a significant relationship with RNF (hazard ratio = 2.07; 95% CI, 0.8-5.5; p = 0.143). The presence of LVI in the T2/3 population did not increase the risk of RNF over that for those with no LVI (p = 0.15). In addition, patients with Grade 3 tumors and positive LVI did not have a higher risk of RNF than those without LVI (p = 0.96). Conclusion: These results suggest that LVI can not be used as a sole indicator for regional nodal irradiation in breast cancer patients with zero to three positive lymph nodes treated with BCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗