Use of Neutron Benchmark Fields for the Validation of Dosimetry Cross Sections.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Explore the source record for details and available documents.
N/A
Not Available
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided
Explore the source record for details and available documents.
Abstract not provided.
In this study, LiAlO2 crystals doped with rare-earth elements and Ti were produced by the CZ method and spectroscopic and neutron detection properties were investigated. Photoluminescence revealed no clear luminescent activation of LiAlO2 by the rare-earth dopants though some interesting luminescence was observed from secondary phases within the crystal. Gamma-ray pulse height spectra collected using a 137Cs source exhibited only a Compton edge for the crystals. Neutron modeling using Monte Carlo N-Particle Transport Code revealed most neutrons used in the detection setup are thermalized, and while using natural lithium in the crystal growth, which contains 7.6 % 6Li, a 10 mm Ø by 10 mm sample of LiAlO2 has a 70.7 % intrinsic thermal neutron capture efficiency. Furthermore, the pulse height spectra collected using a 241Am-Be neutron source demonstrated a distinct neutron peak.
Abstract The shortage of helium-3 (3He) has created a need to identify alternative neutron detection options for a variety of nuclear nonproliferation applications. One application that may be affected by 3He replacement technology is that of mass accountancy for safeguards, which utilizes coincidence and multiplicity counters to verify special nuclear material declarations. The use of neutron scintillation materials, such as LiF-ZnS sheets, as an alternative to 3He proportional tubes in multiplicity counters requires novel techniques for Pulse Shape Discrimination to distinguish between neutrons and gamma rays. These techniques must work under high count rates, as the maximum momentary rate for incoming neutrons from multiplicity events can be quite large. We have created a fast and accurate neutron discrimination algorithm based on time window filtering and signature comparison that can operate quickly on data with high degrees of gamma ray and neutron pileup. This algorithm is evaluated for its capability to separate signals as the pileup rate increases, and the possibility for implementation on fast hardware (e.g., FPGA hardware) for real-time operation is explored.
Spent nuclear fuel comprises a wide range of irradiated isotopic material compositions, and characterization through nondestructive measurements is beneficial in verifying declared parameters before the fuel is placed in storage, final disposal, and/or reprocessed. This paper discusses results from three nondestructive assay instruments, including passive gamma, passive neutron, and active neutron methods, that measured fifty spent fuel assemblies at the Clab interim storage facility in Sweden. Here, integrated analysis of the measurements from the three different instruments allowed parametric assessments of cooling time, burnup, neutron multiplication, fissile mass, initial enrichment, and decay heat of each individual fuel assembly. Passive gamma measurements were found to be the most beneficial in predicting cooling time, passive neutron for determining burnup, active neutron in estimating initial enrichment, and both passive and total neutron for multiplication correlations. Fissile mass was best estimated using any combination of any two of the instruments such that corrections for isotopic changes in the fuel could be accounted for with the first set of measurements and multiplication of the assembly in the second. In conclusion, the nondestructive assay technologies demonstrated through this effort enhance the characterization of spent nuclear fuel assemblies.
Understanding the nucleon spin structure in the regime where the strong interaction becomes truly strong poses a challenge to both experiment and theory. At energy scales below the nucleon mass of about 1 GeV, the intense interaction among the quarks and gluons inside the nucleon makes them highly correlated. Their coherent behaviour causes the emergence of effective degrees of freedom, requiring the application of non-perturbative techniques such as chiral effective field theory1. Here we present measurements of the neutron’s generalized spin polarizabilities that quantify the neutron’s spin precession under electromagnetic fields at very low energy-momentum transfer squared down to 0.035 GeV2. In this regime, chiral effective field theory calculations2–4 are expected to be applicable. Our data, however, show a strong discrepancy with these predictions, presenting a challenge to the current description of the neutron’s spin properties.
Detecting shielded special nuclear material, such as nuclear explosives, is a difficult challenge pursued by non-proliferation, anti-terrorism, and nuclear security programs worldwide. Interrogation with intense fast-neutron pulses is a promising method to characterize concealed nuclear material rapidly but is limited by suitable source availability and proven instrumentation. In this study we have pioneered a demonstration of such an interrogation method using a high-intensity, short-pulse, laser-driven neutron source that offers potential benefits compared to conventional neutron sources. The measurement results reported here represent the first experimental demonstration of this interrogation approach on enriched uranium items and demonstrate the feasibility of a precise measurement using realistic nuclear materials, representative of field scenarios, even with just a single laser-driven neutron pulse. Bright pulsed sources can overcome the nuisance background of items with strong internal neutron sources, improving analytical power, while single-shot assay is attractive in high-throughput situations where time is at a premium. The science and technology of this type of neutron production is developing rapidly, and we anticipate that practical mobile interrogation systems will become available based on the detection concepts demonstrated here to meet the growing measurement needs.
In this study, we present direct evidence for neutrons causing nucleation of supercooled water. Highly purified water (20 nm filtration) is cooled to well below freezing (as low as −20 °C) with a radioactive calibration source of neutrons/gamma-rays either present or removed during each of many control cooling runs for the same volume of water. When it is primarily neutrons irradiating the sample bulk, the non-equilibrium freezing point (also known as the “supercooling point”) is, on average, +0.7 °C warmer than the control equivalent, with a statistical significance of greater than 5 Sigma, with systematic uncertainty included. This effect is not observed with water in the presence of gamma-rays instead of neutrons. While these neutrons should have theoretically had sufficient energy to mount the energy barrier, corroborating our results, their raising of supercooling temperature has never been reported experimentally to the best of our knowledge. The potential to use deeply supercooled solutions, not only water, as metastable detectors for radiation and perhaps dark matter or neutrino physics presents now a new avenue for exploration.
Tagging of neutrons (2.45 MeV) with their associated 3He particles from deuterium-deuterium (D-D) fusion reactions has been demonstrated in a compact neutron generator setup enabled by a high brightness, microwave-driven ion source with a high fraction of deuterons. Energy spectra with well separated peaks of the D-D fusion reaction products, 3 He, tritons, and protons, were measured with a silicon PIN diode. The neutrons were detected using a liquid scintillator detector with pulse shape discrimination. In this work, by correlating the 3 He detection events with the neutron detection in time, we demonstrated the tagging of emitted neutrons with 3 He particles detected with a Si PIN diode detector mounted inside the neutron generator vacuum vessel.