Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NET ENERGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Residential system--Lansing, Michigan

Air collectors are combined with water storage to supply 15 percent of space-heating and hot-water load to residence. Report discusses typical system operation, energy savings, and miantenance for 11 month period. Although unusual combination of water storage with air collecting medium creates loss of heat exchanging efficiency, net energy savings were 21 million Btu.

Source record↗

A Testable Ignition Path on the National Ignition Facility Using Double-Shell Targets

The pursuit of demonstrating thermonuclear ignition and energy gain with single-shell targets on the National Ignition Facility (NIF) is ongoing since 2009. These targets rely on the formation of a high-temperature (~12 keV) “spark” in the deuterium-tritium (DT) fuel near capsule center that triggers an outwardly propagating self-sustaining burn or deflagration wave to the surrounding higher density fuel for realizing appreciable energy gain. This mode of thermonuclear burn is known as ‘hot spot’ ignition. Recent experiments with ‘high foot’ laser drive histories have demonstrated (~2x) net energy gain from the hot spot, but with no appreciable burn propagation into the dense fuel.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Network-Aware and Welfare-Maximizing Dynamic Pricing for Energy Sharing: Preprint

The proliferation of behind-the-meter (BTM) distributed energy resources (DER) within the electrical distribution network presents significant supply and demand flexibilities, but also introduces operational challenges such as voltage spikes and reverse power flows. In response, this paper proposes a network-aware dynamic pricing framework tailored for energy-sharing coalitions that aggregate small, but ubiquitous, BTM DER downstream of a distribution system operator's (DSO) revenue meter that adopts a generic net energy metering (NEM) tariff. By formulating a Stackelberg game between the energy-sharing market leader and its prosumers, we show that the dynamic pricing policy induces the prosumers toward a network-safe operation and decentrally maximizes the energysharing social welfare. The dynamic pricing mechanism involves a combination of a locational ex-ante dynamic price and an ex-post allocation, both of which are functions of the energy sharing's BTM DER. The ex-post allocation is proportionate to the price differential between the DSO NEM price and the energy sharing locational price. Simulation results using real DER data and the IEEE 13-bus test systems illustrate the dynamic nature of network-aware pricing at each bus, and its impact on voltage.

energy communities↗

The Unexpected Oceanic Peak in Energy Input to the Atmosphere and Its Consequences for Monsoon Rainfall

Abstract Monsoons have historically been understood to be caused by the low thermal inertia of land, allowing more energy from summer insolation to be transferred to the overlying atmosphere than over adjacent ocean. Here, we show that during boreal summer, the global maximum net energy input (NEI) to the atmosphere unexpectedly lies over the Indian Ocean, not over land. Observed radiative fluxes suggest that cloud‐radiative effects (CRE) almost double the NEI over ocean, shifting the NEI peak from land to ocean. Global climate model experiments with both land and interactive sea surface temperatures confirm that CRE create the oceanic NEI maximum. Interactions between CRE, NEI, circulation, and land‐sea contrast in surface heat capacity shift precipitation from Southeast to South Asia. CRE thus alter the global partitioning of precipitation between land and ocean and the spatial structure of Earth's strongest monsoon, in ways that can be understood through the NEI.

54 ENVIRONMENTAL SCIENCES↗

Comparison Analysis Between Nevada and TSS Using a Jet Engine Exhaust Nozzle Test Rig

Thermal analysis in both simple and complex models can require calculating the propagation of radiant energy to and from multiple surfaces. This can be accomplished through simple estimation techniques or complex computationally intense computer modeling simulations. Currently there are a variety of computer analysis techniques used to simulate the propagation of radiant energy, each having advantages and disadvantages. The major objective of this effort was to compare two ray tracing radiation propagation analysis programs (NEVADA and TSS) Net Energy Verification and Determination Analyzer and Thermal Synthesizer System with experimental data. Results from a non-flowing, electrically heated test rig was used to verify the calculated radiant energy propagation from a nozzle geometry that represents an aircraft propulsion nozzle system. In general the programs produced comparable overall results, and results slightly higher then the experimental data. Upon inspection of individual radiation interchange factors, differences were evident and would have been magnified if a more radical model temperature profile was analyzed. Bidirectional reflectivity data (BRDF) was not used do to modeling limitations in TSS. For code comparison purposes, this nozzle geometry represents only one case for one set of analysis conditions. Since each computer code has advantages and disadvantages bases on scope, requirements, and desired accuracy, the usefulness of this single case study may be limiting.

Baumeister, Joseph F.↗

Comparative study of the cooling energy performance of variable refrigerant flow systems and variable air volume systems in office buildings

Variable air volume (VAV) and variable refrigerant flow (VRF) systems are widely used in office buildings. This study investigated VAV and VRF systems in five typical office buildings in China, and compared their cooling energy use. Site survey and field measurements were conducted to collect the data of building characteristics and operation. Measured cooling electricity use was collected from sub-metering in the five buildings. The sub-metering data normalized by climate and operating hours indicated that the cooling energy consumed by VRF systems was up to 70% lower than that consumed by VAV systems. This was mainly because of the different operation modes of both system types that led to significantly fewer operating hours for the VRF systems. Building simulations were used to quantify the impact of operation modes of VRF and VAV systems on cooling loads. A prototype office building in China was used as the model. The simulation results showed that the VRF operation mode required much lower cooling load when compared to the VAV operation mode. For example, the cooling loads decreased by 42% in Hong Kong and 53% in Qingdao. Key findings include the following: the VRF systems operated in the part-time-part-space mode enabling occupants to turn on the air-conditioning only when needed and when the spaces were occupied. However, the VAV systems operated in the full-time-full-space mode limiting occupants’ control of operation. These findings provide insights into VRF systems operation and controls as well as their energy performance, which could help guide HVAC designers on system selection and building operators or facility managers on system operations to achieve low- or zero-net energy buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Measurements of energy distribution in microwave plasmas of N2 and He and comparisons with results for H2

An electrothermal propulsion concept utilizing a microwave plasma system as the mechanism to convert electromagnetic energy into translational energy of the flowing gas is being investigated. Specifically, this study compares the energy transfer characteristics of three different gases, H2, N2, and He, to gain some insight as to the dominant energy transfer processes present in a microwave plasma. A calorimetric experimental system has been designed and built enclosing the microwave plasma system to accurately determine the net energy transferred to the flowing gas. Results are obtained for N2 and He discharges and compared with previously reported experimental results for H2.

Chapman, R.↗

Measurements of energy distribution and wall temperature in flowing hydrogen microwave plasma systems

An electrothermal propulsion concept utilizing a microwave plasma system as the mechanism to convert electromagnetic energy into translational energy of the flowing gas is being investigated. A calorimetric experimental system has been designed and built enclosing the microwave plasma system to accurately determine the net energy transferred to the flowing gas. For a flow rate of 8900 micromoles/sec, a pressure of 7.4 torr, and an absorbed power level of 80 W, an energy transfer efficiency of 50 percent has been measured. A heat transfer model that characterizes the energy transfer processes in the plasma is developed. A wall temperature for the plasma system is calculated.

Chapman, R.↗

Building America Case Study: New Town Builders' Power of Zero Energy Center, Denver, Colorado (Brochure)

New Town Builders, a builder of energy efficient homes in Denver, Colorado, offers a zero energy option for all the homes it builds. To attract a wide range of potential homebuyers to its energy efficient homes, New Town Builders created a 'Power of Zero Energy Center' linked to its model home in the Stapleton community of Denver. This case study presents New Town Builders' marketing approach, which is targeted to appeal to homebuyers' emotions rather than overwhelming homebuyers with scientific details about the technology. The exhibits in the Power of Zero Energy Center focus on reduced energy expenses for the homeowner, improved occupant comfort, the reputation of the builder, and the lack of sacrificing the homebuyers' desired design features to achieve zero net energy in the home. The case study also contains customer and realtor testimonials related to the effectiveness of the Center in influencing homebuyers to purchase a zero energy home.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New Whole-House Solutions Case Study: New Town Builders' Power of Zero Energy Center - Denver, Colorado

New Town Builders, a builder of energy efficient homes in Denver, Colorado, offers a zero energy option for all the homes it builds. To attract a wide range of potential homebuyers to its energy efficient homes, New Town Builders created a "Power of Zero Energy Center" linked to its model home in the Stapleton community. This case study presents New Town Builders' marketing approach, which is targeted to appeal to homebuyers' emotions rather than overwhelming homebuyers with scientific details about the technology. The exhibits in the Power of Zero Energy Center focus on reduced energy expenses for the homeowner, improved occupant comfort, the reputation of the builder, and the lack of sacrificing the homebuyers' desired design features to achieve zero net energy in the home. This case study also contains customer and realtor testimonials related to the effectiveness of the Center in influencing homebuyers to purchase a zero energy home.

Building America↗

Gas-Phase Complexes of Americium and Lanthanides with a Bis-triazinyl Pyridine: Reactivity and Bonding of Archetypes for F-Element Separations

Bis-triazinyl pyridines (BTPs) exhibit solution selectivity for trivalent americium over lanthanides (Ln), the origins of which remain uncertain. Here in this paper, electrospray ionization was used to generate gas-phase complexes [ML 3 ] 3+ , where M = La, Lu, or Am and L is EtBTP 2,6-bis(5,6-diethyl-1,2,4-triazin-3-yl)-pyridine. Collision-induced dissociation (CID) of [ML 3 ] 3+ in the presence of H 2 O yielded a protonated ligand [L(H)] + and hydroxide [ML 2 (OH)] 2+ or hydrate [ML(L–H)(H 2 O)] 2+ , where (L–H) - is a deprotonated ligand. Although solution affinities indicate stronger binding of BTPs toward Am 3+ versus Ln 3+ , the observed CID process is contrastingly more facile for M = Am versus Ln. To understand the disparity, density functional theory was employed to compute potential energy surfaces for two possible CID processes, for M = La and Am. In accordance with the CID results, both the rate determining transition state barrier and the net energy are lower for [AmL 3 ] 3+ versus [LaL 3 ] 3+ and for both product isomers, [ML 2 (OH)] 2+ and [ML(L–H)(H 2 O)] 2+ . More facile removal of a ligand from [AmL 3 ] 3+ by CID does not necessarily contradict stronger Am 3+ –L binding, as inferred from solution behavior. In particular, the formation of new bonds in the products can distort kinetics and thermodynamics expected for simple bond cleavage reactions. In addition to correctly predicting the seemingly anomalous CID behavior, the computational results indicate greater participation of Am 5f versus La 4f orbitals in metal–ligand bonding.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Energy Efficiency Potential of Cloud-Based Software: A U.S. Case Study

The energy use of data centers is a topic that has received much attention, given that data centers currently account for 1-2% of global electricity use. However, cloud computing holds great potential to reduce data center energy demand moving forward, due to both large reductions in total servers through consolidation and large increases in facility efficiencies compared to traditional local data centers. However, analyzing the net energy implications of shifts to the cloud can be very difficult, because data center services can affect many different components of society’s economic and energy systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modified Rosenthal Solution for Prediction of In Situ Alloyed GRCop-42 Melt Pool

Literature suggests that the energy needed to in-situ alloy material via additive manufacturing is higher per unit volume than their pre-alloyed counterparts, often despite the in-situ formation of thermodynamically favorable phases. This work, via experiments on in-situ alloyed GRCop-42 (Cu-4 at% Cr-2 at% Nb), will explore the energy needs of an elemental powder blend during in-situ alloying via laser powder bed fusion (LPBF). Empirically derived models will explore the influence of elemental thermophysical properties, net energy of in-situ reactions, and powder characteristics on the resulting LPBF energy demands, weld pool size and shape, and porosity evolution. Additionally, the influence of energy input during printing on the in-situ reaction to form Cr2Nb will be explored. Evolution of Cr2Nb dispersoid and copper grain shape, size, and texture can be related to the temperature reached, cooling rate, and time-as-melt during in-situ alloying via LPBF.

David Scannapieco↗

Evaluating Acoustic vs. AI-Based Satellite Leak Detection in Aging US Water Infrastructure: A Cost and Energy Savings Analysis

The aging water distribution system in the United States, constructed mainly during the 1970s with some pipes dating back 125 years, is experiencing significant deterioration leading to substantial water losses. Along with the potential for water loss savings, improvements in the distribution system by using leak detection technologies can create net energy and cost savings. In this work, a new framework has been presented to calculate the economic level of leakage within water supply and distribution systems for two primary leak detection technologies (acoustic vs. satellite). In this work, a new framework is presented to calculate the economic level of leakage (ELL) within water supply and distribution systems to support smart infrastructure in smart cities. A case study focused using water audit data from Atlanta, Georgia, compared the costs of two leak mitigation technologies: conventional acoustic leak detection and artificial intelligence–assisted satellite leak detection technology, which employs machine learning algorithms to identify potential leak signatures from satellite imagery. The ELL results revealed that conducting one survey would be optimum for an acoustic survey, whereas the method suggested that it would be expensive to utilize satellite-based leak detection technology. However, results for cumulative financial analysis over a 3-year period for both technologies revealed both to be economically favorable with conventional acoustic leak detection technology generating higher net economic benefits of USD 2.4 million, surpassing satellite detection by 50%. A broader national analysis was conducted to explore the potential benefits of US water infrastructure mirroring the exemplary conditions of Germany and The Netherlands. Achieving similar infrastructure leakage index (ILI) values could result in annual cost savings of $\$4$–$\$4.8$ billion and primary energy savings of 1.6–1.9 TWh. These results demonstrate the value of combining economic modeling with advanced leak detection technologies to support sustainable, cost-efficient water infrastructure strategies in urban environments, contributing to more sustainable smart living outcomes.

acoustic leak detection↗

Energy Return on Energy Invested (ERoEI) for photovoltaic solar systems in regions of moderate insolation: A comprehensive response

A recent paper by Ferroni and Hopkirk (2016) asserts that the ERoEI (also referred to as EROI) of photovoltaic (PV) systems is so low that they actually act as net energy sinks, rather than delivering energy to society. Such claim, if accurate, would call into question many energy investment decisions. In the same paper, a comparison is also drawn between PV and nuclear electricity. We have carefully analysed this paper, and found methodological inconsistencies and calculation errors that, in combination, render its conclusions not scientifically sound. Ferroni and Hopkirk adopt 'extended' boundaries for their analysis of PV without acknowledging that such choice of boundaries makes their results incompatible with those for all other technologies that have been analysed using more conventional boundaries, including nuclear energy with which the authors engage in multiple inconsistent comparisons. In addition, they use out-dated information, make invalid assumptions on PV specifications and other key parameters, and conduct calculation errors, including double counting. Here in this paper, we provide revised EROI calculations for PV electricity in Switzerland, adopting both conventional and 'extended' system boundaries, to contrast with their results, which points to an order-of-magnitude underestimate of the EROI of PV in Switzerland by Ferroni and Hopkirk.

14 SOLAR ENERGY↗

From Energy Audits to Home Performance: 30 Years of Articles in Home Energy Magazine

Home Energy Magazine has been publishing articles about residential energy efficiency for 30 years. Its goal has been to disseminate technically reliable and neutral information to the practitioners, that is, professionals in the business of home energy efficiency. The articles, editorials, letters, and advertisements are a kind of window on the evolution of energy conservation technologies, policies, and organizations. Initially, the focus was on audits and simple retrofits, such as weatherstripping and insulation. Instrumentation was sparse sometimes limited to a ruler to measure depth of attic insulation and a blower door was exotic. CFLs were heavy, awkward bulbs which might, or might not, fit in a fixture. Saving air conditioning energy was not a priority. Solar energy was only for the most adventurous. Thirty years on, the technologies and business have moved beyond just insulating attics to the larger challenge of delivering home performance and achieving zero net energy. This shift reflects the success in reducing space heating energy and the need to create a profitable industry by providing more services. The leading edge of the residential energy services market is becoming much more sophisticated, offering both efficiency and solar systems. The challenge is to continue providing relevant and reliable information in a transformed industry and a revolutionized media landscape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Diffusion, Fluxes, Friction Forces, and Joule Heating in Two-Temperature Multicomponent Magnetohydrodynamics

The relationship between Joule heating, diffusion fluxes, and friction forces has been studied for both total and electron thermal energy equations, using general expressions for multicomponent diffusion in two-temperature plasmas with the velocity dependent Lorentz force acting on charged species in a magnetic field. It is shown that the derivation of Joule heating terms requires both diffusion fluxes and friction between species which represents the resistance experienced by the species moving at different relative velocities. It is also shown that the familiar Joule heating term in the electron thermal energy equation includes artificial effects produced by switching the convective velocity from the species velocity to the mass-weighted velocity, and thus should not be ignored even when there is no net energy dissipation.

Chang, C. H.↗