Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microchannel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Speckle imaging with the MAMA detector: Preliminary results

We report on the first successful speckle imaging studies using the Stanford University speckle interferometry system, an instrument that uses a multianode microchannel array (MAMA) detector as the imaging device. The method of producing high-resolution images is based on the analysis of so-called 'near-axis' bispectral subplanes and follows the work of Lohmann et al. (1983). In order to improve the signal-to-noise ratio in the bispectrum, the frame-oversampling technique of Nakajima et al. (1989) is also employed. We present speckle imaging results of binary stars and other objects from V magnitude 5.5 to 11, and the quality of these images is studied. While the Stanford system is capable of good speckle imaging results, it is limited by the overall quantum efficiency of the current MAMA detector (which is due to the response of the photocathode at visible wavelengths and other detector properties) and by channel saturation of the microchannel plate. Both affect the signal-to-noise ratio of the power spectrum and bispectrum.

Horch, E.↗

Delay Line Detectors for the UVCS and Sumer Instruments on the SOHO Satellite

Microchannel plate based detectors with cross delay line image readout have been rapidly implemented for the SUMER and UVCS instruments aboard the Solar Orbiting Heliospheric Observatory (SOHO) mission to be launched in July 1995. In October 1993 a fast track program to build and characterize detectors and detector control electronics was initiated. We present the detector system design for the SOHO UVCS and SUMER detector programs, and results from the detector test program. Two deliverable detectors have been built at this point, a demonstration model for UVCS, and the flight Ly alpha detector for UVCS, both of which are to be delivered in the next few weeks. Test results have also been obtained with one other demonstration detector system. The detector format is 26mm x 9mm, with 1024 x 360 digitized pixels, using a low resistance Z stack of microchannel plates (MCP's) and a multilayer cross delay line anode (XDL). This configuration provides gains of approximately 2 x 10(exp 7) with good pulse height distributions (less than 50% FWHM) under uniform flood illumination, and background levels typical for this configuration (approximately 0.6 event cm (exp -2)sec(exp -1)). Local counting rates up to about 400 events/pixel/sec have been achieved with no degradation of the MCP gain. The detector and event encoding electronics achieves about 25 millimeter FVHM with good linearity (plus or minus approximately 1 pixel) and is stable to high global counting rates (greater than 4 x 10(exp 5) events sec(exp -1)). Flat field images are dominated by MCP fixed pattern noise and are stable, but the MCP multifiber modulation usually expected is uncharacteristically absent. The detector and electronics have also successfully passed both thermal vacuum and vibration tests.

Seigmund, O. H. W.↗

Role of Boundary Conditions in Monte Carlo Simulation of MEMS Devices

A study is made of the issues surrounding prediction of microchannel flows using the direct simulation Monte Carlo method. This investigation includes the introduction and use of new inflow and outflow boundary conditions suitable for subsonic flows. A series of test simulations for a moderate-size microchannel indicates that a high degree of grid under-resolution in the streamwise direction may be tolerated without loss of accuracy. In addition, the results demonstrate the importance of physically correct boundary conditions, as well as possibilities for reducing the time associated with the transient phase of a simulation. These results imply that simulations of longer ducts may be more feasible than previously envisioned.

Nance, Robert P.↗

Scattered light in the STIS echelle modes

The Space Telescope Imaging Spectrograph (STIS) echelle spectra obtained during the Early Release Observations have non-zero residuals in the cores of saturated interstellar lines, indicating the need for a scattered light correction. A rough measure of the magnitude of the needed correction shows the ratio of the interorder to the in-order flux in different echelle modes in both pre-launch calibration images of a continuum lamp source and in post-launch images of stellar continuum sources. The interorder and in-order fluxes are computed by averaging the central 200 pixels in the dispersion direction. The amount of scattered light in the interorder region rises toward shorter wavelengths for two reasons: (1) the order separation decreases toward shorter wavelengths; and (2) the amount of echelle scattering is expected to have an inverse dependence on wavelength. At the shortest wavelengths the fraction of light scattered into the interorder region can be 10% for the Near-ultraviolet-Multi-Anode Microchannel Array (NUV-MAMA) and 15% for the Far-ultraviolet-Multi-Anode Microchannel Array (FUV-MAMA).

Landsman, W.↗

Results From Cs Activated GaN Photocathode Development for MCP Detector Systems at GSFC

We describe the development of high quantum efficiency W photocathodes for use in large area two dimensional microchannel plate based detector arrays to enable new W space astronomy missions. Future W missions will require improvements in detector sensitivity, which has the most leverage for cost-effective improvements in overall telescope/instrument sensitivity. We use new materials such as p-doped GaN, AIGaN, ZnMgO, Sic and diamond. We have currently obtained QE values > 40 % at 185 nm with Cesiated GaN, and hope to demonstrate higher values in the future. By using controlled internal fields and nano-structuring of the surfaces, we plan to provide field emission assistance for photoelectrons while maintaining their energy distinction from dark noise electrons. We will transfer these methods from GaN to ZnMgO, a new family of wide band-gap materials more compatible with microchannel plates. We also are exploring technical parameters such as doping profiles, internal and external field strengths, angle of incidence, field emission assistance, surface preparation, etc.

Norton, Tim↗

Liquid flow and distribution in unsaturated porous media

Flow and transport in permeable or porous media and microchannels occurs in a variety of situations in micro- and reduced-gravity environments, many of them associated with environmental control and life support systems. While the role of gravity is limited, due to the typically small size scales associated permeable media, gravity, at the very least, affects the overall disposition of fluid in a macroscopic system. This presentation will discuss examples where the absence of gravity affects flow and phase distribution in selected examples of unsaturated flow and transport of heat and mass in porous media and microchannels that are pertinent to spacecraft systems.

Alexander, J. Iwan↗

Evaluation of Open Cell Foam Heat Transfer Enhancement for Liquid Rocket Engine

As NASA pursues the exploration mission, advanced propulsion for the next generation of spacecraft will be needed. These new propulsion systems will require higher performance and increased durability, despite current limitations on materials. A break-through technology is needed in the thrust chamber. In this paper the idea of using a porous metallic foam is examined for its potential cooling enhancement capabilities. The goal is to increase the chamber wall cooling without creating an additional pressure drop penalty. A feasibility study based on experiments at laboratory-scale conditions was performed and analysis at rocket conditions is underway. In the experiment, heat transfer and pressure drop data were collected using air as the coolant in a copper or nickel foam filled annular channel. The foam-channel performance was evaluated based on comparison with conventional microchannel cooling passages under equal pressure drop conditions. The heat transfer enhancement of the foam channel over the microchannel ranges from 130% to 172%. The enhancement is relatively independent of the pressure drop and increases with decreasing pore size. A direct numerical simulation model of the foam heat exchange has been built. The model is based on the actual metal foam microstructure of thin ligaments (0.2- 0.3 mm in diameter) that form a network of interconnected open-cells. The cell dimension is around 2 mm. The numerical model was built using the FLUENT CFD code. Comparison of the pressure drop results predicted by the current model with those experimental data of Leong and Jin [8] shows favorable comparisons. Pressure drop predictions have been made using hydrogen as a coolant at typical rocket conditions. Conjugate heat transfer analysis using the foam filled channel is planned for the future.

Chung, J. N.↗

Microfluidics, Chromatography, and Atomic-Force Microscopy

A Raman-and-atomic-force microscope (RAFM) has been shown to be capable of performing several liquid-transfer and sensory functions essential for the operation of a microfluidic laboratory on a chip that would be used to perform rapid, sensitive chromatographic and spectro-chemical analyses of unprecedentedly small quantities of liquids. The most novel aspect of this development lies in the exploitation of capillary and shear effects at the atomic-force-microscope (AFM) tip to produce shear-driven flow of liquids along open microchannels of a microfluidic device. The RAFM can also be used to perform such functions as imaging liquids in microchannels; removing liquid samples from channels for very sensitive, tip-localized spectrochemical analyses; measuring a quantity of liquid adhering to the tip; and dip-pen deposition from a chromatographic device. A commercial Raman-spectroscopy system and a commercial AFM were integrated to make the RAFM so as to be able to perform simultaneous topographical AFM imaging and surface-enhanced Raman spectroscopy (SERS) at the AFM tip. The Raman-spectroscopy system includes a Raman microprobe attached to an optical microscope, the translation stage of which is modified to accommodate the AFM head. The Raman laser excitation beam, which is aimed at the AFM tip, has a wavelength of 785 nm and a diameter of about 5 m, and its power is adjustable up to 10 mW. The AFM is coated with gold to enable tip-localized SERS.

Anderson, Mark↗

Curved Focal-Plane Arrays Using Back-Illuminated High-Purity Photodetectors

Curved-focal-plane arrays of back-illuminated silicon-based photodetectors are being developed. The basic idea is to improve the performance of an imaging instrument and simplify the optics needed to obtain a given level of performance by making an image sensor (e.g., a photographic film or an array of photodetectors) conform to a curved focal surface, instead of following the customary practice of designing the optics to project an image onto a flat focal surface. Eyes are natural examples of optical systems that have curved focal surfaces on which image sensors (retinas) are located. One prior approach to implementation of this concept involves the use of curved-input-surface microchannel plates as arrays of photodetectors. In comparison with microchannel plates, these curved-focal-plane arrays would weigh less, operate at much lower voltages, and consume less power. It should also be possible to fabricate the proposed devices at lower cost. It would be possible to fabricate an array of photodetectors and readout circuitry in the form of a very-large-scale integrated (VLSI) circuit on a curved focal surface, but it would be difficult and expensive to do so. In a simple and inexpensive alternate approach, a device (see figure) would have (1) a curved back surface, onto which light would be focused; and (2) a flat front surface, on which VLSI circuitry would be fabricated by techniques that are well established for flat surfaces. The device would be made from ultrapure silicon, in which it is possible to form high-resistivity, thick photodetectors that are fully depleted through their thicknesses. (As used here, "thick means having a thickness between a fraction of a millimeter and a few millimeters.) The back surface would be polished to the curvature of the focal surface of the intended application. To enable the collection of charge carriers excited by photons near the back surface or in the bulk of the device, it would be necessary to form a transparent or semitransparent back-surface electrode, possibly by delta doping. [Delta doping is so named because its density-vs.-depth characteristic is reminiscent of the Dirac function (impulse function): the dopant is concentrated in a very thin layer - nominally, a single atomic layer.]

Nikzad, Shouleh↗

Microfabrication of a High-Throughput Nanochannel Delivery/Filtration System

A microfabrication process is proposed to produce a nanopore membrane for continuous passive drug release to maintain constant drug concentrations in the patient s blood throughout the delivery period. Based on silicon microfabrication technology, the dimensions of the nanochannel area, as well as microchannel area, can be precisely controlled, thus providing a steady, constant drug release rate within an extended time period. The multilayered nanochannel structures extend the limit of release rate range of a single-layer nanochannel system, and allow a wide range of pre-defined porosity to achieve any arbitrary drug release rate using any preferred nanochannel size. This membrane system could also be applied to molecular filtration or isolation. In this case, the nanochannel length can be reduced to the nanofabrication limit, i.e., 10s of nm. The nanochannel delivery system membrane is composed of a sandwich of a thin top layer, the horizontal nanochannels, and a thicker bottom wafer. The thin top layer houses an array of microchannels that offers the inlet port for diffusing molecules. It also works as a lid for the nanochannels by providing the channels a top surface. The nanochannels are fabricated by a sacrificial layer technique that obtains smooth surfaces and precisely controlled dimensions. The structure of this nanopore membrane is optimized to yield high mechanical strength and high throughput.

Ferrari, Mauro↗

Cascading Tesla Oscillating Flow Diode for Stirling Engine Gas Bearings

Replacing the mechanical check-valve in a Stirling engine with a micromachined, non-moving-part flow diode eliminates moving parts and reduces the risk of microparticle clogging. At very small scales, helium gas has sufficient mass momentum that it can act as a flow controller in a similar way as a transistor can redirect electrical signals with a smaller bias signal. The innovation here forces helium gas to flow in predominantly one direction by offering a clear, straight-path microchannel in one direction of flow, but then through a sophisticated geometry, the reversed flow is forced through a tortuous path. This redirection is achieved by using microfluid channel flow to force the much larger main flow into this tortuous path. While microdiodes have been developed in the past, this innovation cascades Tesla diodes to create a much higher pressure in the gas bearing supply plenum. In addition, the special shape of the leaves captures loose particles that would otherwise clog the microchannel of the gas bearing pads.

Dyson, Rodger↗

Mass and Momentum Transport in Microcavities for Diffusion-Dominant Cell Culture Applications

For the informed design of microfluidic devices, it is important to understand transport phenomena at the microscale. This letter outlines an analytically-driven approach to the design of rectangular microcavities extending perpendicular to a perfusion microchannel for microfluidic cell culture devices. We present equations to estimate the spatial transition from advection- to diffusion-dominant transport inside cavities as a function of the geometry and flow conditions. We also estimate the time required for molecules, such as nutrients or drugs to travel from the microchannel to a given depth into the cavity. These analytical predictions can facilitate the rational design of microfluidic devices to optimize and maintain long-term, physiologically-based culture conditions with low fluid shear stress.

Yew, Alvin G.↗

APES: Acute Precipitating Electron Spectrometer - A High Time Resolution Monodirectional Magnetic Deflection Electron Spectrometer

We present a description of the Acute Precipitating Electron Spectrometer (APES) that was designed and built for the Ground-to-Rocket Electron Electrodynamics Correlative Experiment (GREECE) auroral sounding rocket mission. The purpose was to measure the precipitating electron spectrum with high time resolution, on the order of milliseconds. The trade-off made in order to achieve high time resolution was to limit the aperture to only one look direction. The energy selection was done by using a permanent magnet to separate the incoming electrons, such that the different energies would fall onto different regions of the microchannel plate and therefore be detected by different anodes. A rectangular microchannel plate (MCP) was used (15 mm x 100 mm), and there was a total of 50 discrete anodes under the MCP, each one 15 mm x 1.5 mm, with a 0.5 mm spacing between anodes. The target energy range of APES was 200 eV to 30 keV.

Michell, R. G.↗

Experimental Characterization of Surface Roughness and Geometric Evaluations of Thin-Wall Laser Powder Directed Energy Deposition

Additive Manufacturing (AM) has offered many new design and manufacturing opportunities for components across various industries. As AM evolves there is a need to better understand outputs of the process including geometric limitations and surface roughness based on specific application requirements. One possible application area of AM are components using thin-wall (<2 mm) microchannel heat exchangers for subsystems across aerospace, and industrial applications. AM offers the opportunity to significantly reduce the cost and lead time associated with fabricating these complex parts with internal features such as an array of cooling channels. Laser Powder Bed Fusion (L-PBF) has been continuously demonstrated as a technique to fabricate heat exchangers with internal geometric complexities. However, L-PBF is limited in the scale at which parts can be fabricated. Laser Powder Directed Energy Deposition (LP-DED) has been demonstrated as an AM technology to significantly increase the scale of which thin-wall microchannel heat exchangers could be manufactured. Successful deployment of the LP-DED technology requires critical understanding of the resulting features from the build process. Surface roughness is one of the critical areas that effects the friction factor and pressure drop within a heat exchanger and must be well understood. This presentation will provide an overview of the characterization work completed to understand the LP-DED process for thin-walls representative of hydrogen resistant alloy NASA HR-1 that would be used in a Hydrogen-environment application. An overview of the experiments conducted with varying LP-DED parameters, evaluation of various geometric channel and geometric build features and resulting surface finish will be provided along with a summary of conclusions from these experiments. Results indicate that powder size is a major contributor and surface roughness varies between closed channel shapes and external surfaces.

Directed Energy Deposition↗

Adsorption cooling system using metal organic frameworks

An adsorptive cooling system includes two highly adsorptive structures positioned to receive thermal energy from a thermal energy source, each highly adsorptive structure includes a substrate and a metal-organic framework (MOF) coupled to the respective substrate and adapted for adsorbing and desorbing a refrigerant under predetermined thermodynamic conditions. The adsorptive cooling system includes a cooling unit and a circulation system adapted for circulating the refrigerant from one of the highly adsorptive structures to the cooling unit to provide cooling from the thermal energy source and to return the refrigerant from the cooling unit to the same or other highly adsorptive structure. Each substrate may include a plurality of microchannels, providing ingress and egress paths for a refrigerant, defined by grooves in a surface of the substrate nearest the MOF and/or surfaces of a plurality of microcapillaries of the substrate. The microchannels provide ingress and egress paths for a refrigerant.

Baumann, Theodore F.↗

Additively featured plates for heat exchangers

Hybrid additive featured plates used to form an overall microchannel heat exchanger and corresponding method of manufacture are disclosed. Various additive manufacturing (AM) techniques may be used to form walls defining microchannel features on a plate substrate. The manufacturing method is a hybrid process in that leverages both additive and conventional manufacturing techniques to minimize both cost and fabrication time.

Carlson, Matthew David↗

Multimodal imaging of oil-in-water bilgewater emulsion and biofilms

Bilgewater emulsions, consisting of oil and surfactant mixtures in water, affect many aquatic species. Thus development of methods and techniques to treat or mitigate the formation and undesired consequences of shipboard emulsions are urgently needed. This work presents new results of the evolution of the bilgewaer chemical and physical properties using in situ imaging. A Navy O/W emulsion consisting of three oils and a detergent mixture was used as the synthetic bilgewater model [1, 2]. Synthetic oil-in-water (O/W) emulsion droplets were seled in a vacuum compatible microfluidic sample holder and imaged using a suite of tools including scanning electron microscopy (SEM), time-of-flight secondary ion mass spectrometry (ToF-SIMS), confocal laser scanning microscopy, and optical microscopy, highlighting the advantage of multiscale analysis and its applications in waste reduction and treatment in the environment. The transferrable and vacuum compatible microfluidic interface, System for Analysis at the Liquid Vacuum Interface (SALVI), was used in this study. SALVI enabled surface analysis of liquids and liquid-solid interactions using ToF-SIMS and SEM [3, 4]. Its detection window is an aperture of 2 ?m in diameter open to vacuum, permitting direct detection of the liquid surface. Liquid is withheld by surface tension within the aperture. The interface is composed of a silicon nitride membrane and polydimethylsiloxane microchannel [3, 4]. A variety of samples including complex liquid mixtures, ionic liquids, single mammalian cells, live biofilms, and solid-electrolyte interface have been analyzed using in situ imaging [5, 6]. The feasibility of using SALVI for in situ SEM imaging of nanoparticles and colloids in liquid was recently demonstrated [7]. This paper shows new findings of multimodal imaging and analysis of synthesized emulsion particles in water. Figure 1 depicts a schematic of multimodal in situ imaging of bilgewater emulsion using SEM and ToF-SIMS. Furthermore, we study the interactions of microbes and bilgewater emulsion. Microbes play an important role in the ocean. We hypothesize that microbes release organics that can act as surfactants that affect bilgewater formation or weakening. We present the first systematic study of emulsions and biofilms and investigate the effects of biofilms on bilgewater emulsions. Pseudomonas was selected as a model strain. Biofilms were cultured in a microchannel to allow culture [8]. Once a thick layer of biofilms was formed, the medium solution was changed to a mixture consisting of 50 % bilgewater emulsion. Dispersed biofilms were collected at 24 hrs. and 48 hrs. after emulsions were introduced into the channel. Bilgewater emulsions, biofilms, and mixtures of bilgewater emulsions and biofilms were analyzed using multiple in situ and ex situ techniques as described earlier. Our findings indicate that biofilms change the chemical makeup of the emulsion surface compositions and emulsion droplet size distribution, confirming the hypothesis that extracellular polymeric substance (EPS) related components released from biofilms can function as surfactants and change the oil-in-water interfaces.

bilgewater, multimodal imaging, biofilms↗

Design complexity and performance analysis in additively manufactured heat exchangers

The main objective of this research is to investigate the tradeoffs between design complexity and thermal performance in additively manufactured metallic heat exchangers. Such heat exchangers have become a favorite topic for investigation in various fields ranging from air conditioning to aircraft gas turbine engines. In particular, high manufacturing cost has emerged as the major drawback in broad applications of manifold-microchannel heat exchanger (MMHXs). The possibility of cost-effective manufacturing has generated wide interest in applying additive manufacturing (AM) for fabricating MMHXs. Furthermore, AM technologies will provide an opportunity for enhanced design and superior heat transfer performance. In this study, innovative MMHXs are designed and fabricated through selective laser melting. An experimental setup was designed to measure pressure drop and heat transfer for the developed MMHXs with a wide range of Reynolds numbers. Furthermore, the coefficient of performance was calculated based on the heat flow rate, air pressure drop, and air flow rate. Measurement results demonstrated that in some scenarios adding more internal features, i.e., increasing design complexity, does not necessarily improve the MMHX performance.

10 SYNTHETIC FUELS↗