Implementation of Leak Test Methods for the International Space Station (ISS) Elements, Systems and Components

The International Space Station (ISS has Qualification and Acceptance Environmental Test Requirements document, SSP 41172 that includes many environmental tests such as Thermal vacuum & Cycling, Depress/Repress, Sinusoidal, Random, and Acoustic Vibration, Pyro Shock, Acceleration, Humidity, Pressure, Electromatic Interference (EMI)/Electromagnetic Compatibility (EMCO), etc. This document also includes (13) leak test methods for Pressure Integrity Verification of the ISS Elements, Systems, and Components. These leak test methods are well known, however, the test procedure for specific leak test method shall be written and implemented paying attention to the important procedural steps/details that, if omitted or deviated, could impact the quality of the final product and affect the crew safety. Such procedural steps/details for different methods include, but not limited to: - Sequence of testing, f or example, pressurization and submersion steps for Method I (Immersion); - Stabilization of the mass spectrometer leak detector outputs fo r Method II (vacuum Chamber or Bell jar); - Proper data processing an d taking a conservative approach while making predictions for on-orbit leakage rate for Method III(Pressure Change); - Proper Calibration o f the mass spectrometer leak detector for all the tracer gas (mostly Helium) Methods such as Method V (Detector Probe), Method VI (Hood), Method VII (Tracer Probe), Method VIII(Accumulation); - Usage of visibl ility aides for Method I (Immersion), Method IV (Chemical Indicator), Method XII (Foam/Liquid Application), and Method XIII (Hydrostatic/Visual Inspection); While some methods could be used for the total leaka ge (either internal-to-external or external-to-internal) rate requirement verification (Vacuum Chamber, Pressure Decay, Hood, Accumulation), other methods shall be used only as a pass/fail test for individual joints (e.g., welds, fittings, and plugs) or for troubleshooting purposes (Chemical Indicator, Detector Probe, Tracer Probe, Local Vacuum Chamber, Foam/Liquid Application, and Hydrostatic/Visual Inspection). Any isolation of SSP 41172 requirements have led to either retesting of hardware or accepting a risk associated with the potential system or component pressure integrity problem during flight.

Underwood, Steve↗

A Particle-in-Cell Method for Plasmas with a Generalized Momentum Formulation, Part II: Enforcing the Lorenz Gauge Condition

In a previous paper Christlieb et al. (A particle-in-cell method for plasmas with a generalized momentum formulation, part I: Model formulation, 2024), we developed a new particle-in-cell (PIC) method for the relativistic Vlasov–Maxwell system in which the electromagnetic fields and the equations of motion for the particles were cast in terms of scalar and vector potentials through a Hamiltonian formulation. This new method evolved the potentials under the Lorenz gauge using integral equation methods. New methods to construct spatial derivatives of the potentials that converge at the same rates as the fields were also presented. The new particle method was compared against standard explicit discretizations, including the well-known FDTD-PIC method, for a range of applications involving sheaths and particle beams. Here, this paper extends this new class of methods by focusing on the enforcement the Lorenz gauge condition in both exact and approximate forms using co-located meshes. A time-consistency property of the proposed field solver for the vector potential form of Maxwell’s equations is established, which is shown to preserve the equivalence between the semi-discrete Lorenz gauge condition and the analogous semi-discrete continuity equation. Using this property, we present three methods to enforce a semi-discrete gauge condition. The first method introduces an update for the continuity equation that is consistent with the discretization of the Lorenz gauge condition. Both the finite difference and spectral implementations satisfy this discrete gauge condition to machine precision. The second approach we propose enforces a semi-discrete continuity equation using the boundary integral solution to the field equations. The potential benefit of this approach is that it eliminates spatial derivatives that appear on the particle data, namely the current density, which is often calculated by linear combinations of low-order spline basis functions. This method is ideally suited to boundary integral equation methods that invert multi-dimensional operators without dimensional splitting techniques and will be the subject of future work. The third approach introduces a gauge correcting method that makes direct use of the gauge condition to modify the scalar potential and uses local maps for both the charge and current densities. This results in a gauge error, as the maps do not enforce the continuity equation. The vector potential coming from the current density is taken to be exact, and using the Lorenz gauge, we compute a correction to the scalar potential that makes the two potentials satisfy the gauge condition. This method also enforces the gauge condition to machine precision. We demonstrate two of the proposed methods in the context of periodic domains. Problems defined on bounded domains, including those with complex geometric features remain an ongoing effort. However, this work shows that it is possible to design computationally efficient methods that can effectively enforce the Lorenz gauge condition in a non-staggered PIC formulation.

97 MATHEMATICS AND COMPUTING↗

The multigrid preconditioned conjugate gradient method

A multigrid preconditioned conjugate gradient method (MGCG method), which uses the multigrid method as a preconditioner of the PCG method, is proposed. The multigrid method has inherent high parallelism and improves convergence of long wavelength components, which is important in iterative methods. By using this method as a preconditioner of the PCG method, an efficient method with high parallelism and fast convergence is obtained. First, it is considered a necessary condition of the multigrid preconditioner in order to satisfy requirements of a preconditioner of the PCG method. Next numerical experiments show a behavior of the MGCG method and that the MGCG method is superior to both the ICCG method and the multigrid method in point of fast convergence and high parallelism. This fast convergence is understood in terms of the eigenvalue analysis of the preconditioned matrix. From this observation of the multigrid preconditioner, it is realized that the MGCG method converges in very few iterations and the multigrid preconditioner is a desirable preconditioner of the conjugate gradient method.

Tatebe, Osamu↗

Urban Image Classification: Per-Pixel Classifiers, Sub-Pixel Analysis, Object-Based Image Analysis, and Geospatial Methods: Chapter - 10

Remote sensing methods used to generate base maps to analyze the urban environment rely predominantly on digital sensor data from space-borne platforms. This is due in part from new sources of high spatial resolution data covering the globe, a variety of multispectral and multitemporal sources, sophisticated statistical and geospatial methods, and compatibility with GIS data sources and methods. The goal of this chapter is to review the four groups of classification methods for digital sensor data from space-borne platforms; per-pixel, sub-pixel, object-based (spatial-based), and geospatial methods. Per-pixel methods are widely used methods that classify pixels into distinct categories based solely on the spectral and ancillary information within that pixel. They are used for simple calculations of environmental indices (e.g., NDVI) to sophisticated expert systems to assign urban land covers. Researchers recognize however, that even with the smallest pixel size the spectral information within a pixel is really a combination of multiple urban surfaces. Sub-pixel classification methods therefore aim to statistically quantify the mixture of surfaces to improve overall classification accuracy. While within pixel variations exist, there is also significant evidence that groups of nearby pixels have similar spectral information and therefore belong to the same classification category. Object-oriented methods have emerged that group pixels prior to classification based on spectral similarity and spatial proximity. Classification accuracy using object-based methods show significant success and promise for numerous urban 3 applications. Like the object-oriented methods that recognize the importance of spatial proximity, geospatial methods for urban mapping also utilize neighboring pixels in the classification process. The primary difference though is that geostatistical methods (e.g., spatial autocorrelation methods) are utilized during both the pre- and post-classification steps. Within this chapter, each of the four approaches is described in terms of scale and accuracy classifying urban land use and urban land cover; and for its range of urban applications. We demonstrate the overview of four main classification groups in Figure 1 while Table 1 details the approaches with respect to classification requirements and procedures (e.g., reflectance conversion, steps before training sample selection, training samples, spatial approaches commonly used, classifiers, primary inputs for classification, output structures, number of output layers, and accuracy assessment). The chapter concludes with a brief summary of the methods reviewed and the challenges that remain in developing new classification methods for improving the efficiency and accuracy of mapping urban areas.

Myint, Soe W.↗

Uncertainty Models for the Hybrid Parametric Variation Method of Uncertainty Quantification; Analysis

There is some level of uncertainty in every finite element model (FEM), which flows to a level of uncertainty in predicted results. The purpose of uncertainty quantification (UQ) is to provide statistical bounds on prediction accuracy based on model uncertainty. This is distinct from model updating, which attempts to modify models to improve their accuracy. UQ does not improve the accuracy of models, but accepts that the models are inherently inaccurate and attempts to quantify the impact of that inaccuracy on predicted results. Previously, an alternate method for UQ, called the Hybrid Parametric Variation (HPV) method, was applied to Space Launch System (SLS) Hurty/Craig-Bampton (HCB) components to predict system-level statistics for launch vehicle attitude control transfer functions and core stage section loads due to buffet. The HPV method combines a parametric variation of the HCB fixed-interface (FI) modal frequencies with a nonparametric variation (NPV) method that randomly varies the HCB mass and stiffness matrices as Wishart random matrix distributions using random matrix theory (RMT). Alternatively, the most common method for modeling uncertainty in the structural dynamics community is a parametric approach, which varies physical parameters in the model. However, there are several disadvantages associated with the parametric method. Determining a reduced set of parameters that have a significant impact on the system response can be time consuming, and the selected parameter probability distributions are rarely reliably known. Therefore, in practice, the parameters are surrogates for the actual errors, and the link to parameter uncertainty is unknown. Another major drawback is that the uncertainty that can be represented is limited to the form of the nominal FEM. It is the experience of the authors that based on numerous aerospace programs, almost all FEM errors are in form rather than parameter values. This hypothesis is supported by the observation of the authors that it is almost never possible to ‘tune’ a FEM to match modal test results by only modifying model parameters. Model-form uncertainty cannot be directly represented by FEM input parameters nor included in a parametric approach. However, model-form uncertainty can be modeled using RMT, where a probability distribution is developed for the matrix ensemble of interest. The major advantage of the NPV method is that it covers errors in model form. The HPV method anchors uncertainty at the HCB component level to component modal test results by matching the HCB and test modes based on mode descriptions or other methods, and then applying differing levels of frequency variation. The specific variations depend on the confidence to which a component FEM has been validated through modal testing. The NPV method is layered on the frequency variation to match modal test self-orthogonality and cross-orthogonality (XO) results. Once the component uncertainty models are identified, they are assembled, and the uncertainty is propagated to the system level using a Monte Carlo (MC) analysis approach that generates statistics for system-level predictions This provides a UQ method that can be traced to test data, which can be updated as additional data and improved correlated models become available. The purpose of this paper is to collect and present all of the theory for HPV that has been previously published in reports and papers and to present examples of its application. Specifically, component uncertainty models based on the dispersion of corresponding mass and stiffness matrices using proposed test/analysis correlation metrics are investigated. The first example is purely academic so that the true answers are known, and the validity of the HPV method and the corresponding uncertainty models can be determined. The purpose of this paper is to collect and present all of the theory for HPV that has been previously published in reports and papers and to present examples of its application. Specifically, component uncertainty models based on the dispersion of corresponding mass and stiffness matrices using proposed test/analysis correlation metrics are investigated. The first example is purely academic so that the true answers are known, and the validity of the HPV method and the corresponding uncertainty models can be determined. The second example is an application to a component that is design specific to the SLS. Based on this work and other assessments, the HPV method provides another tool to the toolset used for complex system UQ analysis. From experience gathered to date using the HPV method, additional design specific applications must be investigated to provide further confidence in the validity of the HPV method of UQ analysis.

Uncertainty quantification↗

Recovery of DNA from fired and unfired cartridge casings: comparison of two DNA collection methods

For over 10 years, various studies have attempted to increase the recovery of DNA from ammunition by modifying the DNA collection, extraction, purification, and amplification procedures, with varying levels of success. This study focused on the “soaking” method of Montpetit & O’Donnell [1] and the “rinse-and-swab" method of Bille et al. [2]. First, testing for the presence of exogenous DNA, 210 boxed cartridges (brass, steel, and nickel-plated) from nine manufacturers were swabbed and DNA was extracted, concentrated, and quantified. Extracts that quantified > 0 ng/µL (44 of 210) were amplified and genotyped with GlobalFiler™. Of those, only one extract yielded two alleles indicating that the manufacturing and packaging of ammunition was virtually DNA free. Next, to obtain a baseline comparison of two DNA collection methods on a non-metallic substrate and identify a suitable number of cells to spot on cartridges, different DNA input amounts of primary human adult epidermal keratinocytes (HEKa) were tested. Thereafter, 300 brass and 300 nickel-plated, cartridges were spotted with HEKa cells containing ~5 ng of DNA, fired or unfired, and processed with either method. Finally, five methods representing hybrids of the soaking and rinse-and-swab methods were tested to determine if variations of those methods could be used to increase DNA yield and recovery. The results show that the soaking method consistently yielded more DNA than the rinse-and-swab method from a non-metallic substrate. However, the comparison study demonstrated that both methods performed comparably for cartridges. On average, the soaking method recovered 0.25 ng of DNA (5.1% recovery) and the rinse-and-swab method recovered 0.28 ng (5.8% recovery). However, average recoveries were significantly different among three analysts and considerable variation in yields were observed, possibly due to storage time. Furthermore, consistent with prior reports, the DNA recovered from brass casings was only 16% of that recovered from nickel-plated casings and the average yield of DNA from fired casings was reduced to 67% of unfired casings. Moreover, DNA extracts from brass or nickel-plated casings did not appear to contain amplification inhibitors and only 30/596 appeared severely degraded. Finally, both the published rinse-and-swab and soaking methods yielded more DNA than all modifications of the two methods. Overall, both methods yielded equivalent DNA quantities. Additionally, recovery of DNA from any given cartridge casing may be dependent on storage time as well as the skill, proficiency, and experience of the analyst and may reflect stochastic effects, particularly for casings containing low copy and/or degraded DNA.

59 BASIC BIOLOGICAL SCIENCES↗

Methods for analysis of cracks in three-dimensional solids

Various analytical and numerical methods used to evaluate the stress intensity factors for cracks in three-dimensional (3-D) solids are reviewed. Classical exact solutions and many of the approximate methods used in 3-D analyses of cracks are reviewed. The exact solutions for embedded elliptic cracks in infinite solids are discussed. The approximate methods reviewed are the finite element methods, the boundary integral equation (BIE) method, the mixed methods (superposition of analytical and finite element method, stress difference method, discretization-error method, alternating method, finite element-alternating method), and the line-spring model. The finite element method with singularity elements is the most widely used method. The BIE method only needs modeling of the surfaces of the solid and so is gaining popularity. The line-spring model appears to be the quickest way to obtain good estimates of the stress intensity factors. The finite element-alternating method appears to yield the most accurate solution at the minimum cost.

Raju, I. S.↗

Multigrid Methods for Fully Implicit Oil Reservoir Simulation

In this paper we consider the simultaneous flow of oil and water in reservoir rock. This displacement process is modeled by two basic equations: the material balance or continuity equations and the equation of motion (Darcy's law). For the numerical solution of this system of nonlinear partial differential equations there are two approaches: the fully implicit or simultaneous solution method and the sequential solution method. In the sequential solution method the system of partial differential equations is manipulated to give an elliptic pressure equation and a hyperbolic (or parabolic) saturation equation. In the IMPES approach the pressure equation is first solved, using values for the saturation from the previous time level. Next the saturations are updated by some explicit time stepping method; this implies that the method is only conditionally stable. For the numerical solution of the linear, elliptic pressure equation multigrid methods have become an accepted technique. On the other hand, the fully implicit method is unconditionally stable, but it has the disadvantage that in every time step a large system of nonlinear algebraic equations has to be solved. The most time-consuming part of any fully implicit reservoir simulator is the solution of this large system of equations. Usually this is done by Newton's method. The resulting systems of linear equations are then either solved by a direct method or by some conjugate gradient type method. In this paper we consider the possibility of applying multigrid methods for the iterative solution of the systems of nonlinear equations. There are two ways of using multigrid for this job: either we use a nonlinear multigrid method or we use a linear multigrid method to deal with the linear systems that arise in Newton's method. So far only a few authors have reported on the use of multigrid methods for fully implicit simulations. Two-level FAS algorithm is presented for the black-oil equations, and linear multigrid for two-phase flow problems with strong heterogeneities and anisotropies is studied. Here we consider both possibilities. Moreover we present a novel way for constructing the coarse grid correction operator in linear multigrid algorithms. This approach has the advantage in that it preserves the sparsity pattern of the fine grid matrix and it can be extended to systems of equations in a straightforward manner. We compare the linear and nonlinear multigrid algorithms by means of a numerical experiment.

Molenaar, J.↗

To have value, comparisons of high-throughput phenotyping methods need statistical tests of bias and variance

The gap between genomics and phenomics is narrowing. The rate at which it is narrowing, however, is being slowed by improper statistical comparison of methods. Quantification using Pearson’s correlation coefficient ( r ) is commonly used to assess method quality, but it is an often misleading statistic for this purpose as it is unable to provide information about the relative quality of two methods. Using r can both erroneously discount methods that are inherently more precise and validate methods that are less accurate. These errors occur because of logical flaws inherent in the use of r when comparing methods, not as a problem of limited sample size or the unavoidable possibility of a type I error. A popular alternative to using r is to measure the limits of agreement (LOA). However both r and LOA fail to identify which instrument is more or less variable than the other and can lead to incorrect conclusions about method quality. An alternative approach, comparing variances of methods, requires repeated measurements of the same subject, but avoids incorrect conclusions. Variance comparison is arguably the most important component of method validation and, thus, when repeated measurements are possible, variance comparison provides considerable value to these studies. Statistical tests to compare variances presented here are well established, easy to interpret and ubiquitously available. The widespread use of r has potentially led to numerous incorrect conclusions about method quality, hampering development, and the approach described here would be useful to advance high throughput phenotyping methods but can also extend into any branch of science. The adoption of the statistical techniques outlined in this paper will help speed the adoption of new high throughput phenotyping techniques by indicating when one should reject a new method, outright replace an old method or conditionally use a new method.

59 BASIC BIOLOGICAL SCIENCES↗

Assessment of software methods for estimating protein-protein relative binding affinities

A growing number of computational tools have been developed to accurately and rapidly predict the impact of amino acid mutations on protein-protein relative binding affinities. Such tools have many applications, for example, designing new drugs and studying evolutionary mechanisms. In the search for accuracy, many of these methods employ expensive yet rigorous molecular dynamics simulations. By contrast, non-rigorous methods use less exhaustive statistical mechanics, allowing for more efficient calculations. However, it is unclear if such methods retain enough accuracy to replace rigorous methods in binding affinity calculations. This trade-off between accuracy and computational expense makes it difficult to determine the best method for a particular system or study. Here, eight non-rigorous computational methods were assessed using eight antibody-antigen and eight non-antibody-antigen complexes for their ability to accurately predict relative binding affinities (ΔΔG) for 654 single mutations. In addition to assessing accuracy, we analyzed the CPU cost and performance for each method using a variety of physico-chemical structural features. This allowed us to posit scenarios in which each method may be best utilized. Most methods performed worse when applied to antibody-antigen complexes compared to non-antibody-antigen complexes. Rosetta-based JayZ and EasyE methods classified mutations as destabilizing (ΔΔG < -0.5 kcal/mol) with high (83–98%) accuracy and a relatively low computational cost for non-antibody-antigen complexes. Some of the most accurate results for antibody-antigen systems came from combining molecular dynamics with FoldX with a correlation coefficient (r) of 0.46, but this was also the most computationally expensive method. Overall, our results suggest these methods can be used to quickly and accurately predict stabilizing versus destabilizing mutations but are less accurate at predicting actual binding affinities. This study highlights the need for continued development of reliable, accessible, and reproducible methods for predicting binding affinities in antibody-antigen proteins and provides a recipe for using current methods.

59 BASIC BIOLOGICAL SCIENCES↗

Improved Collision-Detection Method for Robotic Manipulator

An improved method has been devised for the computational prediction of a collision between (1) a robotic manipulator and (2) another part of the robot or an external object in the vicinity of the robot. The method is intended to be used to test commanded manipulator trajectories in advance so that execution of the commands can be stopped before damage is done. The method involves utilization of both (1) mathematical models of the robot and its environment constructed manually prior to operation and (2) similar models constructed automatically from sensory data acquired during operation. The representation of objects in this method is simpler and more efficient (with respect to both computation time and computer memory), relative to the representations used in most prior methods. The present method was developed especially for use on a robotic land vehicle (rover) equipped with a manipulator arm and a vision system that includes stereoscopic electronic cameras. In this method, objects are represented and collisions detected by use of a previously developed technique known in the art as the method of oriented bounding boxes (OBBs). As the name of this technique indicates, an object is represented approximately, for computational purposes, by a box that encloses its outer boundary. Because many parts of a robotic manipulator are cylindrical, the OBB method has been extended in this method to enable the approximate representation of cylindrical parts by use of octagonal or other multiple-OBB assemblies denoted oriented bounding prisms (OBPs), as in the example of Figure 1. Unlike prior methods, the OBB/OBP method does not require any divisions or transcendental functions; this feature leads to greater robustness and numerical accuracy. The OBB/OBP method was selected for incorporation into the present method because it offers the best compromise between accuracy on the one hand and computational efficiency (and thus computational speed) on the other hand.

Leger, Chris↗

Demonstrating Computational Equivalence Between Continuous and Discrete Adjoint Methods by Calculating Time-Dependent Adjoint Solutions with Neutron Diffusion Models

The continuous adjoint method and the discrete adjoint method are two alternative approaches used to calculate adjoint solutions for adjoint systems. The continuous adjoint method derives adjoint equations analytically from continuous forward equations and then solves the adjoint equations either analytically or numerically in a discretized form whereas the discrete adjoint method calculates the adjoint solutions directly from the discretized forward equations. With regard to the methodology development and calculation procedure, distinct differences are well recognized between the two methods. For certain reasons, both methods are exclusively preferred and commonly used by different computational communities, but limited studies clarify the connections between the two adjoint methods from either of the communities. Herein, this paper demonstrates the computational equivalence between the continuous and discrete adjoint methods by investigating time-dependent adjoint solutions to the two-group neutron diffusion model in nuclear reactor analysis problems using both methods. Adjoint solutions can be used to estimate system parameters for reactor safety analysis. Appropriate final state conditions for the adjoint systems are specified in both of the methods, and the conditions are clarified with proper physical explanations. With the help of an event-based case study on neutron diffusion models, the accuracy of the time-dependent adjoint fluxes obtained from both methods is verified, and the pros and cons of both adjoint methods are examined. More importantly, the computational equivalence of both methods is demonstrated when they are applied to multigroup neutron diffusion systems. The advantage of calculating time-dependent adjoint fluxes by directly solving time-dependent adjoint systems rather than taking steady-state approximations as in common practice is also demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of finite-volume methods to capture shocks and turbulence spectra in compressible flows

The aim of the present paper is to provide a comparison between several finite-volume methods of different numerical accuracy: the second-order Godunov method with PPM interpolation and the high-order finite-volume WENO method. In this work, the results show that while on a smooth problem the high-order method performs better than the second-order one, when the solution contains a shock all the methods collapse to first-order accuracy. In the context of the decay of compressible homogeneous isotropic turbulence with shocklets, the actual overall order of accuracy of the methods reduces to second-order, despite the use of fifth-order reconstruction schemes at cell interfaces. Most important, results in terms of turbulent spectra are similar regardless of the numerical methods employed, except that the PPM method fails to provide an accurate representation in the high-frequency range of the spectra. It is found that this specific issue comes from the slope-limiting procedure and a novel hybrid PPM/WENO method is developed that has the ability to capture the turbulent spectra with the accuracy of a high-order method, but at the cost of the second-order Godunov method. Overall, it is shown that virtually the same physical solution can be obtained much faster by refining a simulation with the second-order method and carefully chosen numerical procedures, rather than running a coarse high-order simulation. Our results demonstrate the importance of evaluating the accuracy of a numerical method in terms of its actual spectral dissipation and dispersion properties on mixed smooth/shock cases, rather than by the theoretical formal order of convergence rate.

97 MATHEMATICS AND COMPUTING↗

Improved accuracy for finite element structural analysis via a new integrated force method

A comparative study was carried out to determine the accuracy of finite element analyses based on the stiffness method, a mixed method, and the new integrated force and dual integrated force methods. The numerical results were obtained with the following software: MSC/NASTRAN and ASKA for the stiffness method; an MHOST implementation method for the mixed method; and GIFT for the integrated force methods. The results indicate that on an overall basis, the stiffness and mixed methods present some limitations. The stiffness method generally requires a large number of elements in the model to achieve acceptable accuracy. The MHOST method tends to achieve a higher degree of accuracy for course models than does the stiffness method implemented by MSC/NASTRAN and ASKA. The two integrated force methods, which bestow simultaneous emphasis on stress equilibrium and strain compatibility, yield accurate solutions with fewer elements in a model. The full potential of these new integrated force methods remains largely unexploited, and they hold the promise of spawning new finite element structural analysis tools.

Patnaik, Surya N.↗

Improved accuracy for finite element structural analysis via an integrated force method

A comparative study was carried out to determine the accuracy of finite element analyses based on the stiffness method, a mixed method, and the new integrated force and dual integrated force methods. The numerical results were obtained with the following software: MSC/NASTRAN and ASKA for the stiffness method; an MHOST implementation method for the mixed method; and GIFT for the integrated force methods. The results indicate that on an overall basis, the stiffness and mixed methods present some limitations. The stiffness method generally requires a large number of elements in the model to achieve acceptable accuracy. The MHOST method tends to achieve a higher degree of accuracy for course models than does the stiffness method implemented by MSC/NASTRAN and ASKA. The two integrated force methods, which bestow simultaneous emphasis on stress equilibrium and strain compatibility, yield accurate solutions with fewer elements in a model. The full potential of these new integrated force methods remains largely unexploited, and they hold the promise of spawning new finite element structural analysis tools.

Patnaik, S. N.↗

Investigation of computational and spectral analysis methods for aeroacoustic wave propagation

Most computational fluid dynamics (CFD) schemes are not adequately accurate for solving aeroacoustics problems, which have wave amplitudes several orders of magnitude smaller yet with frequencies larger than the flow field variations generating the sound. Hence, a computational aeroacoustics (CAA) algorithm should have minimal dispersion and dissipation features. A dispersion relation preserving (DRP) scheme is, therefore, applied to solve the linearized Euler equations in order to simulate the propagation of three types of waves, namely: acoustic, vorticity, and entropy waves. The scheme is derived using an optimization procedure to ensure that the numerical derivatives preserve the wave number and angular frequency of the partial differential equations being discretized. Consequently, simulated waves propagate with the correct wave speeds and exhibit their appropriate properties. A set of radiation and outflow boundary conditions, compatible with the DRP scheme and derived from the asymptotic solutions of the governing equations, are also implemented. Numerical simulations are performed to test the effectiveness of the DRP scheme and its boundary conditions. The computed solutions are shown to agree favorably with the exact solutions. The major restriction appears to be that the dispersion relations can be preserved only for waves with wave lengths longer than four or five spacings. The boundary conditions are found to be transparent to the outgoing disturbances. However, when the disturbance source is placed closer to a boundary, small acoustic reflections start appearing. CAA generates enormous amounts of temporal data which needs to be reduced to understand the physical problem being simulated. Spectral analysis is one approach that helps us in extracting information which often can not be easily interpreted in the time domain. Thus, three different methods for the spectral analysis of numerically generated aeroacoustic data are studied. First, the capabilities of two traditional methods for spectral analysis, namely, the Blackman-Tukey method and periodogram method, are compared in estimating the spectra of a simple-periodic process. The periodogram is then applied to analyze transitory-deterministic processes. Finally, these two methods are compared with a more recent method, referred as the Weighted-Overlapped-Segment-Averaging (WOSA) method, in estimating the spectra of a chaotic (random-like) process. From the demonstrative case for the spectral analyses of data generated by simple-periodic process, the periodogram method is found to give a better estimate of the steep-sloped spectra than the Blackman-Tukey method. Also, for this problem, the Hanning window is found to perform better with the periodogram method than with the Blackman-Tukey method. Finally, for the spectral analysis of data generated by the chaotic process, the periodogram method does not perform well, whereas, the WOSA and Blackman-Tukey methods give equivalently good results.

Vanel, Florence O.↗

Further evaluation of traditional icing scaling methods

This report provides additional evaluations of two methods to scale icing test conditions; it also describes a hybrid technique for use when scaled conditions are outside the operating envelope of the test facility. The first evaluation is of the Olsen method which can be used to scale the liquid-water content in icing tests, and the second is the AEDC (Ruff) method which is used when the test model is less than full size. Equations for both scaling methods are presented in the paper, and the methods were evaluated by performing icing tests in the NASA Lewis Icing Research Tunnel (IRT). The Olsen method was tested using 53 cm diameter NACA 0012 airfoils. Tests covered liquid-water-contents which varied by as much as a factor of 1.8. The Olsen method was generally effective in giving scale ice shapes which matched the reference shapes for these tests. The AEDC method was tested with NACA 0012 airfoils with chords from 18 cm to 53 cm. The 53 cm chord airfoils were used in reference tests, and 1/2 and 1/3 scale tests were made at conditions determined by applying the AEDC scaling method. The scale and reference airspeeds were matched in these tests. The AEDC method was found to provide fairly effective scaling for 1/2 size tests, but for 1/3 size models, scaling was generally less effective. In addition to these two scaling methods, a hybrid approach was also tested in which the Olsen method was used to adjust the LWC after size was scaled using the constant Weber number method. This approach was found to be an effective way to test when scaled conditions would otherwise be outside the capability of the test facility.

Anderson, David N.↗