Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Metering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Integration of Behind-the-Meter PV Fleet Forecasts into Utility Grid System Operations

Four major research objectives were completed over the course of this study. Three of the objectives were to evaluate three, new, state-of-the-art solar irradiance forecasting models. The fourth objective was to improve the California Independent System Operator’s (ISO) load forecasts by integrating behind-the-meter (BTM) PV forecasts. The three, new, state-of-the-art solar irradiance forecasting models included: the infrared (IR) satellite-based cloud motion vector (CMV) model; the WRF-SolarCA model and variants; and the Optimized Deep Machine Learning (ODML)-training model. The first two forecasting models targeted known weaknesses in current operational solar forecasts. They were benchmarked against existing operational numerical weather prediction (NWP) forecasts, visible satellite CMV forecasts, and measured PV plant power production. IR CMV, WRF-SolarCA, and ODML-training forecasting models all improved the forecast to a significant degree. Improvements varied depending on time of day, cloudiness index, and geographic location. The fourth objective was to demonstrate that the California ISO’s load forecasts could be improved by integrating BTM PV forecasts. This objective represented the project’s most exciting and applicable gains. Operational BTM forecasts consisting of 200,000+ individual rooftop PV forecasts were delivered into the California ISO’s real-time automated load forecasting (ALFS) environment. They were then evaluated side-by-side with operational load forecasts with no BTM-treatment. Overall, ALFS-BTM day-ahead (DA) forecasts performed better than baseline ALFS forecasts when compared to actual load data. Specifically, ALFS-BTM DA forecasts were observed to have the largest reduction of error during the afternoon on cloudy days. Shorter term 30 minute-ahead ALFS-BTM forecasts were shown to have less error under all sky conditions, especially during the morning time periods when traditional load forecasts often experience their largest uncertainties. This work culminated in a GO decision being made by the California ISO to include zonal BTM forecasts into its operational load forecasting system. The California ISO’s Manager of Short Term Forecasting, Jim Blatchford, summarized the research performed in this project with the following quote: “The behind-the-meter (BTM) California ISO region forecasting research performed by Clean Power Research and sponsored by the Department of Energy’s SUNRISE program was an opportunity to verify value and demonstrate improved load forecast capability. In 2016, the California ISO will be incorporating the BTM forecast into the Hour Ahead and Day Ahead load models to look for improvements in the overall load forecast accuracy as BTM PV capacity continues to grow.”

14 SOLAR ENERGY↗

Simplified Processing Method for Meter Data Analysis

Simple/Quick metered data processing method that can be used for Army Metered Data Management System (MDMS) and Logistics Innovation Agency data, but may also be useful for other large data sets. Intended for large data sets when analyst has little information about the buildings.

97 MATHEMATICS AND COMPUTING↗

Chapter 9: Metering Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy-Efficiency Savings for Specific Measures

Estimated energy savings are calculated as the difference between the energy use during the baseline period and the energy use during the post installation period of the EEM. This chapter describes the physical properties measured in the process of evaluating EEMs and the specific metering methods for several types of measurements. Skill-level requirements and other operating considerations are discussed, including where, when, and how often measurements should be made. The subsequent section identifies metering equipment types and their respective measurement accuracies. This is followed by sections containing suggestions regarding proper data handling procedures and the categorization and definition of several load types.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Virtual Net Metering Market Development Project Final Technical Report

Virtual net metering (VNEM) is a policy and billing arrangement that allows energy generation credits from a single solar system to be shared virtually among multiple subscribers. In California, VNEM is limited to onsite installations, meaning that the subscribers to that system must be located on the same property as the installation. Subscriber accounts will belong to those living or working in an onsite multi-tenant building, such as tenants within an apartment complex. VNEM enables the expansion of photovoltaic (PV) adoption beyond traditional commercial and single-family roof top systems to those who live in multitenant housing, which is an essential pathway for ensuring equal solar access for all consumers. Since 2008, VNEM has been available in the territories of California’s three large investor-owned utilities (IOUs), including San Diego Gas and Electric (SDG&E), Southern California Edison (SCE), and Pacific Gas and Electric (PG&E), and since then, has evolved into several sub-tariffs, each of which is applicable to specific building types and customer sectors. For instance, from 2008 - 2012, VNEM was only available for the affordable housing sector. In 2012, VNEM was expanded to the general market and was available to any multi-tenant, multi-metered building. It should also be noted that in 2018, an affordable-housing VNEM tariff was expanded to customers within the Liberty Utility and PacifiCorp Utility territories. The use of VNEM for market-rate buildings, since 2012, has been limited, reasons for which our project sought to address.

14 SOLAR ENERGY↗

Photovoltaic and Behind-the-Meter Battery Storage: Advanced Smart Inverter Controls and Field Demonstration

Electric utilities have little visibility of the electrical distribution system, and consequently, limited diagnostic capabilities. The distribution grid was designed for a unidirectional power flow, where energy is supplied by few large centralized power plants; however, this is set to change to meet California’s aggressive decarbonization goals. The large-scale deployment of distributed renewable generation, such as photovoltaics (PV), can have many negative effects on an unprepared grid. As illustrated in the California “duck curve,” PV generation modifies load profiles during the day, which causes steep ramping in the evening. This effect indicates the need to revise the electrical grid’s design and operation. This project sought to (a) create a centralized resource in California to test and validate distribution technology controls with industry standard PV, storage, and high-fidelity sensors, (b) support strategic and operational decisions for new grid architectures by providing simulation models, (c) promote new ways to control clusters of PV smart inverters, in accordance with California Rule 21, and (d) innovate, develop, and field test a predictive controller to maximize economic profit for the customer while supporting the grid. The controller was built using the state-of-the-art model predictive control methodology to optimally control behind-the-meter PV and battery storage. In consideration of the duck curve, the controller optimally controls the battery dispatch by charging during excess generation periods and discharging during the critical afternoon demand hours. The controller was evaluated in annual simulations and revealed the potential cost-effectiveness of behind-the-meter battery storage. The simulations showed that the annual electricity bill could be reduced by as much as 35 percent, with a payback period of the investment in battery storage in about 6 years – significantly shorter than the manufacturer’s 10-year warranty. All developed simulation models, the grid event library, and the MPC controller are open-source and available online.

Model Predictive control↗

Loose Belt Fault Detection and Virtual Flow Meter Development Using Identified Data-driven Energy Model for Fan Systems

An energy model that correlates fan airflow, head, speed, and system power input is essential to detect device faults and optimize control strategies in fan systems. Since the application of variable-frequency drives (VFDs) makes the motor-efficiency data published by manufacturers inapplicable for VFD–motor–fan systems, the fan efficiency and drive (belt–motor–VFD) efficiency must be identified for each individual system to obtain accurate energy models. The objectives of this paper are to identify an energy model of existing VFD–motor–fan systems using available experimental data and demonstrate its applications in loose belt fault detection and virtual airflow meter development for optimal control. First, an approach is developed to identify the fan head, fan efficiency, and drive-efficiency curves using available fan head, speed, and system power input as well as temporarily measured airflow rate without measuring shaft power. Then, the energy model is identified for an existing VFD–motor–fan system. Finally, the identified model is applied to detect the slipped belt faults and develop the virtual airflow meter. The experiment results reveal that the developed approach can effectively obtain the energy model of VFD–motor–fan systems and the model can be applied to effectively detect slipped belt faults and accurately calculate the fan airflow rate.

42 ENGINEERING↗

Low-rate gas flow meter.

Low rate gas flow meter noting sealing and controlling of piston, differential pressure meter and DC servoamplifier

GAS FLOW↗

Laboratory Evaluation of Dynamic Routing of Air Traffic in an En Route Arrival Metering Environment

Arrival air traffic operations in the presence of convective weather are subject to uncertainty in aircraft routing and subsequently in flight trajectory predictability. Current management of arrival operations in weather-impacted airspace results in significant flight delay and suspension of arrival metering operations. The Dynamic Routing for Arrivals in Weather (DRAW) concept provides flight route amendment advisories to Traffic Management Coordinators to mitigate the impacts of convective weather on arrival operations. DRAW provides both weather conflict and schedule information for proposed route amendments, allowing air traffic managers to simultaneously evaluate weather avoidance routing and potential schedule and delay impacts. Subject matter experts consisting of retired Traffic Management Coordinators and retired Sector Controllers with arrival metering experience participated in a simulation study of Fort Worth Air Route Traffic Control Center arrival operations. Data were collected for Traffic Management Coordinator and Sector Controller participants over three weeks of simulation activities in October, 2017. Traffic Management Coordinators reported acceptable workload levels, a positive impact on their ability to manage arrival traffic while using DRAW, and initiated weather mitigation reroutes earlier while using DRAW. Sector Controllers also reported acceptable workload levels while using DRAW.

Air Traffic Management↗

Laboratory Evaluation of Dynamic Routing of Air Traffic in an En Route Arrival Metering Environment

Arrival air traffic operations in the presence of convective weather are subject to uncertainty in aircraft routing and subsequently in flight trajectory predictability. Current management of arrival operations in weather-impacted airspace results in significant flight delay and suspension of arrival metering operations. The Dynamic Routing for Arrivals in Weather (DRAW) concept provides flight route amendment advisories to Traffic Management Coordinators to mitigate the impacts of convective weather on arrival operations. DRAW provides both weather conflict and schedule information for proposed route amendments, allowing air traffic managers to simultaneously evaluate weather avoidance routing and potential schedule and delay impacts. Subject matter experts consisting of retired Traffic Management Coordinators and retired Sector Controllers with arrival metering experience participated in a simulation study of Fort Worth Air Route Traffic Control Center arrival operations. Data were collected for Traffic Management Coordinator and Sector Controller participants over three weeks of simulation activities in October, 2017. Traffic Management Coordinators reported acceptable workload levels, a positive impact on their ability to manage arrival traffic while using DRAW, and initiated weather mitigation reroutes earlier while using DRAW. Sector Controllers also reported acceptable workload levels while using DRAW.

Air Traffic Management↗

A Tactical Scheduler for Surface Metering Under Minimum Departure Interval Restrictions

Minimum Departure Interval (MDI) and Miles-In-Trail (MIT) are common traffic management tools. They both require minimum separation between departures to meet specific traffic conditions. The MDI restriction is a time separation requirement between departures, usually on the same Standard Instrument Departure (SID), whereas the MIT restriction is a distance separation requirement between aircraft, including but not limited to departure flights, to meet specific criteria associated with flight path or destination. At Incheon International Airport (IATA code: ICN) in South Korea, MDIs are imposed on 92% of departure flights. They involve specific criteria including not only having identical SID, but also satisfying other conditions, imposed on the flight path and destination. To address complicated MDI constraints, Korea Aerospace Research Institute (KARI) has been developing and improving a tactical scheduler for surface metering at ICN to provide appropriate target times for pushbacks and takeoffs for departure flights under MDIs. This paper describes the MDI requirements at ICN, the development of a heuristic scheduling algorithm to work with the MDI restrictions, and the performance evaluation of the algorithm through fast-time simulations. The performance evaluation results indicate that the proposed heuristic algorithm can provide the surface metering schedules that comply with the MDI restrictions without significant performance degradation.

DMAN (Departure Management)↗

FEDERAL SECTOR METERING AND ENERGY DATA MANAGEMENT

Conference paper for West Coast Energy Management Congress regarding the Federal Building Metering Guidance, subsequent metering implementation plans, and the next steps for Federal agencies.

data management↗

Disaggregating Smart Meter Data to Identify Electric Loads and Control Opportunities

As utility data, such as smart meter data, becomes more broadly available, there is general interest in using it to improve utility operations and enable adoption of other advanced technology - such as solar photovoltaics (PV), energy storage, and controls. We explore one such use case - identifying electric resistance water heaters from smart meter data, as well as characterizing their potential for load-shifting to support grid voltage stability under high-penetration PV adoption. This paper shows the limitation of typical 15-minute data, and how shortterm capture of additional 1-minute data is needed to enable the desired application. Results indicate about 4 kWh water heating load can be shifted to align with peak sun hours in a low use home. This methodology is an example, and can be adapted to other grid-integrated efficient building use cases.

14 SOLAR ENERGY↗

Design of Resilient Electric Distribution Systems for Remote Communities: Surgical Load Management Using Smart Meters: Preprint

This paper describes a systematic process of designing resilient electric distribution systems and microgrids using smart meters for surgical load management (SLM) as part of Advanced Metering Infrastructure (AMI). The work focuses on selection approach, integration, and interoperability aspects for AMI in microgrids. SLM is proposed as a granular control methodology for serving selective critical loads across different distribution feeders in the system during extreme events. The surgical load shedding as well as load pick-up provides a robust approach for maximizing critical load served in a resource-constrained electric distribution system or a microgrid. We present the case of a 20 MW islanded microgrid in Cordova, AK, USA, which is the demonstration site for field validation of resilience enhancement technologies for the DOE-funded Grid Modernization project RADIANCE. Cordova microgrid is an islanded distribution grid that provides an environment to prove the approach, and the techniques may also be applicable to other regional distribution systems.

microgrids↗

Towards Non-Intrusive Real-Time Monitoring of Behind the Meter Residential Distributed Energy Resources

The growing adoption of residential distributed energy resources (DERs) introduces more uncertain variability in power grid operation. More importantly, the residential DERs operate behind customers’ energy meters, and therefore, the utility cannot “directly” monitor them. Prior approaches to enable visibility into behind-the-meter (BTM) DERs either depend on estimations or require intrusive instrumentation on the customer side. To address the critical need for direct real-time monitoring of BTM DERs, in this paper, we propose a novel approach for utility-side direct real-time monitoring of residential BTM DERs. We utilize high-frequency (> 10kHz) conducted electromagnetic interference (EMI) from residential DERs’ grid-tied inverters to monitor their power generation. We discuss the working principle of our approach and present supporting results using three of-the-shelf grid-tied inverters.

14 SOLAR ENERGY↗

Workshop: Advanced Metering for Decarbonization: Electric Vehicles and 24/7 Carbon-Free Electricity

The purpose of this workshop is to learn more about advanced metering best practices for meeting the goals of EO 14057. This will be a 2-part session, first part to include presentations on the FEMP best practice work related to metering: 1) Electric Vehicles (EVs) and EV charging station electricity use. 2) Integrating data sources to calculate hourly carbon pollution-free electricity (CFE). Second part will facilitate small group discussions with a problem-solving activity.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

An analytical method for identifying synergies between behind-the-meter battery and thermal energy storage

Electric utilities build generation capacity to meet the highest demand period, and they often pass on the costs associated with these peaking generators to building owners through demand charges. Building owners can minimize these demand charges by shifting energy use away from peak periods with behind-the-meter storage. This storage can include batteries, which can directly shift the metered load, or thermal energy storage, which can shift thermal-driven electric loads like air conditioning. However, there is a lack of research on how best to combine battery and thermal energy storage. In this study, we develop an analytical sizing method to calculate the potential demand reduction and annualized cost savings for different combinations of thermal and battery energy storage sizes. We show that adding batteries to a thermal energy storage system can increase the total system's load shaving potential. This is particularly true when the building has onsite photovoltaic generation or electric vehicle charging, which add significant variability to the load shape. We also show that for a given total storage size, selecting a higher fraction of thermal energy storage can significantly lower the cycling of the battery, and therefore extend the battery life. This, combined with the expected lower first cost of thermal energy storage materials compared to batteries, shows that hybrid energy storage systems can outperform a standalone battery or standalone thermal storage system. Assuming the thermal storage has a capital cost 6x lower than the battery, our analysis shows that the optimal system is 71% thermal energy storage and 29% battery energy storage for a scenario with electric vehicle charging. The annualized cost savings for this system are $48.6 k/yr, whereas an equivalently sized standalone thermal energy storage system would provide annualized cost savings of $28.5 k/yr and a standalone battery would lead to savings of $8.72 k/yr. The hybrid system also reduces battery cycling by 52% compared to a standalone battery, extending battery lifetime.

25 ENERGY STORAGE↗

The importance of sub-meter-scale snow roughness on conductive heat flux of Arctic sea ice

Abstract The conductive heat flux through the snow and ice is a critical component of the mass and energy budgets in the Arctic sea ice system. We use high horizontal resolution (3–15 cm) measurements of snow topography to explore the impacts of sub-meter-scale snow surface roughness on heat flux as simulated by the Finite Element method. Simulating horizontal heat flux in a variable snow cover modestly increases the total simulated heat flux. With horizontal heat flux, as opposed to simple 1D-vertical heat flux modeling, the simulated heat flux is 10% greater than that for uniform snow with the same mean snow thickness for a 31.5 × 21 m region of sea ice (the largest region we studied). Vertical-only (1D) heat flux simulates just a 6% increase for the same region. However, this is highly dependent on observation resolution. Had we measured the snow cover at 1 m horizontal spacing or greater, simulating horizontal heat flux would not have changed the net heat flux from that simulated with vertical-only heat flux. These findings suggest that measuring and modeling snow roughness at sub-meter horizontal scales may be necessary to accurately represent horizontal heat flux on level Arctic sea ice.

Geology↗