Search for organic material in lunar fines by mass spectrometry
Apollo 11 lunar fines organic compounds detection and identification by mass spectrometry
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Apollo 11 lunar fines organic compounds detection and identification by mass spectrometry
A twin Knudsen cell apparatus for alloy activity measurements by mass spectrometry is described. Two Knudsen cells - one containing an alloy and one containing a pure component - are mounted on a single flange and translated into the sampling region via a motorized x-y table. Mixing of the molecular beams from the cells is minimized by a novel system of shutters. Activity measurements were taken on two well-characterized alloys to verify the operation of the system. Silver activity measurements are reported for Ag-Cu alloys and aluminum activity measurements are reported for Fe-Al alloys. The temperature dependence of activity for a 0.474 mol fraction Al-Fe alloy gives a partial molar heat of aluminum. Measurements taken with the twin cell show good agreement with literature values for these alloys.
The present invention provides for a differential electrochemical mass spectrometry (DEMS) cell comprising a working electrode chamber configured such that an electrolyte enters the working electrode chamber through a channel running through the working electrode.
Tandem column gas-liquid chromatography labeling technique for mass spectrometry, noting ketones exchange and data on deutrium and oxygen compounds
Illicit drug use causes over half a million deaths worldwide every year. Drugs of abuse are commonly smuggled through customs and border checkpoints and, increasingly, through parcel delivery services. Improved methods for detection of trace drug residues from surfaces are needed. Such methods should be robust, fieldable, sensitive, and capable of detecting a wide range of drugs. In this work, commercially produced paper with a pressure-sensitive adhesive coating was utilized for the collection and analysis of trace drug residues by paper spray mass spectrometry (MS). This modified substrate was used to combine sample collection of drug residues from surfaces with rapid detection using a single paper spray ticket. The all-in-one ticket was used to probe different surfaces commonly encountered in forensic work including clothing, cardboard, glass, concrete, asphalt, and aluminum. A total of 10 drugs (acetyl fentanyl, fentanyl, clonazolam, cocaine, heroin, ketamine, methamphetamine, methylone, U-47700, and XLR-11) were evaluated and found to be detectable in the picogram range using a benchtop mass spectrometer and in the low nanogram range using a portable ion trap MS. Finally, the novel approach demonstrates a simple yet effective sampling strategy, allowing for rapid identification from difficult surfaces via paper spray mass spectrometry.
There is a rapidly growing need for new materials for extreme ultraviolet (EUV) lithography, which incorporate high EUV absorbing elements. Hybrid resists, which are a combination of inorganic and organic moieties, are promising as they offer both high EUV sensitivity and high etch resistance. However, there is a glaring lack of methods to examine the uniformity of these important materials at the nanoscale. We examine the capabilities of nano-projectile secondary ion mass spectrometry (NP-SIMS) to investigate hybrid resists. NP-SIMS is a mass spectrometry-based technique with high lateral resolution. Using NP-SIMS, a surface is probed stochastically with a suite of individual projectiles, 10 6 to 10 7 in total, separated in time and space. Examining these individual mass spectra allows for nanoscale investigation of the uniformity of the surface. We evaluated the performance of NP-SIMS using samples of poly(methyl methacrylate) (PMMA) infiltrated with varying amounts of InO x via vapor-phase infiltration (VPI), an organic–inorganic hybridization method derived from atomic layer deposition. Here, we found that NP-SIMS measurements contained abundant characteristic ions related to both the PMMA and infiltrated In. The intensity of In atomic ions increased linearly with the number of infiltration cycles; however, the uniformity of In and PMMA varied with the number of infiltration cycles. After one cycle, we found that both the PMMA and In were relatively inhomogeneous. The homogeneity improved with subsequent infiltration cycles. In addition, NP-SIMS measurements contained characteristic ions related to the infiltration reaction and provided insights into the VPI mechanism. Overall, the results show that NP-SIMS is capable of examining both the inorganic and organic moieties in a hybrid resist and will be an important method for understanding the performance of these materials for use in EUV lithography.
PBX 9404, composed of 94 wt% HMX (1,3,5,7-Tetranitro-1,3,5,7-tetrazoctane), 3 wt% NC (nitrocellulose), 2.9 wt% CEF (tris(beta-chloroethyl) phosphate) and 0.1 wt% DPA (diphenylamine), has often been observed with a slight to entire blue discoloration of the manufactured prills. This blue discoloration has been observed since the formulation development of PBX 9404 in the late 1950s. In order to determine the source of the blue discoloration in PBX 9404, ultraviolet/visible (UV/Vis) absorbance of PBX 9404 and two potential candidates for the discoloration, p-nitrosodiphenylamine (p-NDPA) and N-nitrosodiphenylamine (N-NDPA) were evaluated. An absorbance band at 590 nm in PBX 9404 sample was attributed to the blue discoloration while p-NDPA and N-NPDA had different absorbance bands. Using the knowledge gained from the UV/Vis analysis, a semi-targeted approach using ultrahigh pressure liquid chromatography coupled to UV/Vis detector and quadrupole time of flight mass spectrometry (UHPLC-UV/Vis-QTOF) was implemented. Investigating the UHPLC-UV/Vis-QTOF chromatograms at a wavelength of 590 nm, a single compound was tentatively identified as being the source of the blue discoloration. Targeted tandem mass spectrometry (MS/MS) on the compound and subsequent analysis indicated that 4,4 -{[4-(Phenylimino)-2,5-cyclohexadien-1-ylidene]methylene}bis(N-phenylaniline), also known as Spirit Blue Base, was the source of the blue discoloration, which was confirmed using a standard. Here, a theory on the formation of Spirit Blue Base in PBX 9404 involving DPA, nitric acid (HNO 3 ) / nitrogen oxide(s) NO x , and formaldehyde is proposed.
The study of complex, multistep bond-forming and -breaking reactions in heterogeneous catalytic systems often encounters challenges associated with the involvement of large numbers of intermediates among branching pathways. Kinetic information obtained from traditional steady-state measurements can be complemented with that from time-resolved methods to uncover details of the underlying chemistry. Herein, we describe an approach for tracking the complete time-resolved chemical composition (ca. 4–200 u) of a reactor effluent in response to a reactant pulse. We use a six-port rotary valve with a metered sampling loop to pulse reactants at ambient pressure into a flow reactor packed with a catalyst bed within the isothermal region of a heated furnace. The temporal evolution of effluent species is tracked using time-resolved molecular-beam time-of-flight mass spectrometry. We highlight the possibilities that this method has to offer by studying the complex bifunctional mechanism of ethane dehydroaromatization over an HZSM-5-supported platinum catalyst. We demonstrate that energy-tunable ionization sources, which facilitate isomer resolution, enable the measurement of the full mass spectral time-dependent system response. This includes the evolution of major products and mechanistically relevant reactive intermediates such as 1,3-butadiene and cyclopentadiene; these species have not previously been observed from this reaction. In additional studies, we also assess the role of platinum in the catalyst by examining temporal responses to ethane and ethylene feeds. Results show that two temporally distinct formation pathways exist for methane and benzene, and that their importance depends on both catalyst composition and reactant identity. Additionally, characteristics of catalyst deactivation are uniquely observable in the time-resolved mass spectral response, including the selective deactivation of a benzene formation pathway. The combination of time-of-flight mass spectrometry with tunable ionization enables the simultaneous observation of all effluents in a complex mixture of intermediates with isomer/isobar differentiation capabilities that can be applied to any complex reaction system.
In beam-based ionization methods, the substrate plays an important role on the desorption mechanism of molecules from surfaces. Both the specific orientation that a molecule adopts at a surface and the strength of the molecule-surface interaction can greatly influence desorption processes, which in turn will affect the ion yield and the degree of in-source fragmentation of a molecule. In the beam-based method of secondary ion mass spectrometry (SIMS), in-source fragmentation can be significant and molecule specific due to the hard ionization method of using a primary ion beam for molecule desorption. To investigate the role of the substrate on orientation and in-source fragmentation, we have used atomistic simulations—molecular dynamics in combination with density functional theory calculations—to explore the desorption of a sphingolipid (palmitoylsphingomyelin) from a model surface (gold). We then compare SIMS data from this model system to our modeling findings. Using this approach, we found that the combined adsorption and binding energy of certain bonds associated with the headgroup fragments (C3H8N+, C5H12N+, C5H14NO+, and C5H15PNO4+) was a good predictor for fragment intensities (as indicated by relative ion yields). This is the first example where atomistic simulations have been applied in beam-based ionization of lipids, and it presents a new approach to study biointerfacial lipid ordering effects on SIMS imaging.
Lipids play essential roles in many biological processes and disease pathology, but unambiguous identification of lipids is complicated by the presence of multiple isomeric species differing by fatty acyl chain length, stereospecifically numbered (sn) position, and position/stereochemistry of double bonds. Conventional liquid chromatography-mass spectrometry (LC-MS/MS) analyses enable the determination of fatty acyl chain lengths (and in some cases sn position) and number of double bonds, but not carbon-carbon double bond positions. Ozone-induced dissociation (OzID) is a gas-phase oxidation reaction that produces characteristic fragments from lipids containing double bonds. OzID can be incorporated into ion mobility spectrometry (IMS)-MS instruments for the structural characterization of lipids, including additional isomer separation and confident assignment of double bond positions. The complexity and repetitive nature of OzID data analysis and lack of software tool support have limited the application of OzID for routine lipidomics studies. Here, we present an open-source Python tool, LipidOz, for the automated determination of lipid double bond positions from OzID-IMS-MS data, which employs a combination of traditional automation and deep learning approaches. Our results demonstrate the ability of LipidOz to robustly assign double bond positions for lipid standard mixtures and complex lipid extracts, enabling practical application of OzID for future lipidomics.
Instances of food contamination with per- and polyfluoroalkyl substances (PFAS) continue to occur globally, but sample preparation and analytical methods are quite limited and often monitor for a small percentage of known PFAS. This study aimed to evaluate, validate, and compare performance of two instruments with the recently developed “quick, easy, cheap, effective, rugged, safe, efficient, and robust” (QuEChERSER) sample preparation mega-method – a method developed to monitor chemicals over a broad range of physicochemical properties. Initial evaluation of the QuEChERSER mega-method for determination of PFAS in food demonstrated recoveries, matrix interferences, and co-extractive removal comparable to (or better than) US Food and Drug Administration (FDA) and USDA Food Safety and Inspection Service (FSIS) methods. Subsequent validation of QuEChERSER in beef, catfish, chicken, pork, liquid eggs, and powdered eggs on a high-resolution mass spectrometer achieved acceptable recoveries (70–120%) and precision (RSDs ≤20%) for all 33 target analytes at the 1 and 5 ng g –1 levels and 67–88% of analytes at the 0.1 ng g –1 level, depending on the matrix. Additional validation was performed by tandem mass spectrometry on a triple quadrupole instrument. This approach provided no non-detects and better recoveries at the 0.1 ng g –1 level than the HRMS method but exhibited more variability at 1 and 5 ng g –1 spiking levels. Analysis of NIST SRMs 1946 and 1947 gave accuracies of 70–117%. Furthermore, these results demonstrate the capability of combining PFAS analysis with a mega-method previously validated for 350 analytes, while collecting non-target data for future retrospective analysis of emerging alternatives with a high-resolution mass spectrometry method.
Select natural variant switchgrass genotypes grown in Tifton, GA were analyzed by Pyrolysis-Molecular Beam Mass Spectrometry (Py-MBMS). Biomass was harvested, milled, several genotypes were analyzed with and without being destarched and extracted with ethanol prior to analysis (indicated with -DE if destarched and extracted). Py-MBMS analysis was conducted using approximately 4 mg of biomass and each sample was analyzed in duplicate. A Frontier PY2020 unit pyrolyzed samples at 500°C for 30 s in 80 µL deactivated stainless steel cups. An Extrel Super-Sonic MBMS Model Max 1000 was used to collect mass spectral data fromm/z30 to 450 at 17 eV and processed using Merlin Automation software (V3). Spectral ion intensities were normalized to the total ion chromatogram signal for each sample for analysis of spectral variance. Lignin content (wt %) was estimated based on relative responses from standards of known Klason lignin content using mean-normalized ion intensities ofm/z120, 124 (G), 137 (G), 138 (G), 150 (G), 152, 154 (S), 164 (G), 167 (S), 168 (S), 178 (G), 180, 181, 182 (S), 194 (S), 208 (S) and 210 (S) where G indicates guaiacyl-derived ions, S indicates syringyl-derived ions, and other ions either derive from other lignin monomers or multiple sources. Ratios of S and G lignin monomer units (S/G) were obtained by dividing the sum of S-based ions by the sum of G-based ions using mean-normalized ion intensities.
Abstract Advancing our understanding of dissolved organic matter (DOM) chemistry in aquatic systems necessitates the integration of data streams from multiple analytical platforms. Some measurements require pretreatment with solid phase extraction (SPE), while others are performed directly on whole water samples. Evidence has suggested that SPE will be biased against select DOM fractions, leading to concerns over the ability to establish data linkages across platforms with variable needs for SPE pretreatment, such as those from optical measurements and those that provide high‐resolution molecular information. Here, we directly addressed this concern by assessing the impact of SPE on DOM optical properties through excitation–emission matrices with parallel factor analysis (PARAFAC) for 47 samples across a stream network within a single watershed reflective of variable DOM sources. PARAFAC data was further paired with molecular information obtained by Fourier transform ion cyclotron resonance mass spectrometry (FTICR‐MS). A comparison of PARAFAC models first revealed no systematic qualitative differences in major components between whole water DOM and DOM isolated by SPE (SPE‐DOM); however, quantitative biases against select components were observed. Further linkages with FTICR‐MS data revealed that the molecular fingerprint associated with each PARAFAC component was consistent between the whole water DOM and SPE‐DOM. Our results suggest that bulk scale linkages across these analytical platforms could be inferred irrespective of the observed quantitative biases resulting from SPE for samples within this example watershed. This work represents a key step toward the systematic evaluation of linkages between optical and high‐resolution mass spectrometry datasets in freshwater lotic environments.
Current risk assessments for environmental carcinogens rely on animal studies utilizing doses orders of magnitude higher than actual human exposures. Epidemiological studies of people with high exposures (e.g., occupational) are of value, but rely on uncertain exposure data. In addition, exposures are typically not to a single chemical but to mixtures, such as polycyclic aromatic hydrocarbons (PAHs). The extremely high sensitivity of accelerator mass spectrometry (AMS) allows for dosing humans with known carcinogens with de minimus risk. In this study UPLC-AMS was used to assess the toxicokinetics of [ 14 C]-benzo[a]pyrene ([ 14 C]-BaP) when dosed alone or in a binary mixture with phenanthrene (Phe). Plasma was collected for 48 h following a dose of [ 14 C]-BaP (50 ng, 5.4 nCi) or the same dose of [ 14 C]-BaP plus Phe (1250 ng). Following the binary mixture, C max of [ 14 C]-BaP significantly decreased (4.4-fold) whereas the volume of distribution (V d ) increased (2-fold). Further, the toxicokinetics of twelve [ 14 C]-BaP metabolites provided evidence of little change in the metabolite profile of [ 14 C]-BaP and the pattern was overall reduction consistent with reduced absorption (decrease in C max ). Although Phe was shown to be a competitive inhibitor of the major hepatic cytochrome P-450 (CYP) responsible for metabolism of [ 14 C]-BaP, CYP1A2, the high inhibition constant (K i ) and lack of any increase in unmetabolized [ 14 C]-BaP in plasma makes this mechanism unlikely to be responsible. Rather, co-administration of Phe reduces the absorption of [ 14 C]-BaP through a mechanism yet to be determined. Furthermore, this is the first study to provide evidence that, at actual environmental levels of exposure, the toxicokinetics of [ 14 C]-BaP in humans is markedly altered by the presence of a second PAH, Phe, a common component of environmental PAH mixtures.
Gas phase reaction between ions and molecules using mass spectrometry with time as kinetic variable, specifically methane-deuterium mixtures
The intersection of modern artificial intelligence (AI) and mass spectrometry (MS) is set to transform the MS‐based “omics” research fields, particularly proteomics, metabolomics, lipidomics, and glycomics, enabling advancements across a wide range of domains, from health to environment and industrial biotechnology. Beginning with an overview of key challenges inherent in MS software pipelines, this personal perspective explores how AI‐driven solutions can address them to enhance data processing, integration and interpretation. It proposes a paradigm shift in molecular identification and quantitation algorithms, leveraging AI to enable holistic interpretation of MS‐based multiomics data. While centered on MS‐based omics, this holistic AI‐driven paradigm is also critical for connecting dynamic biochemical changes to genomics and transcriptomics contexts, reinforcing the integrative value of MS in multiomics research. Ultimately, this AI‐driven approach could enhance efficiency, accuracy, and molecular breadth of coverage, deepening our systems‐level understanding of biological processes and accelerating a myriad of biodiscoveries.
The high-resolution measurement capability of Fourier-transform mass spectrometry (FT-MS) has made it a necessity for exploring the molecular composition of complex organic mixtures, like soil, plant, aquatic, and petroleum samples. This demand has driven a need for informatics tools to explore and analyze FT-MS data in a robust and reproducible manner. FREDA is an interactive web application developed to enable spectrometrists to format, process, and explore their FT-MS data without the need for statistical programming expertise. FREDA was built to explore outputs from a molecular identification tool, like CoreMS, and provide a suite of methods to filter data, compute chemical properties of peaks, statistically compare samples and groups of samples, conduct exploratory data analysis, and download the results with a report detailing all steps conducted. To demonstrate the utility of FREDA, an example analysis was conducted using FT-MS data from a soil microbiology study of samples collected in two different soil depths at the Sphagnum bog forest north of Grand Rapids, Minnesota. Differences between the two depths are observed using Kendrick, Gibbs free energy, and van Krevelen plots. G-tests are used to quantify a significant difference between the groups. All analyses and plotting are conducted using only the FREDA application. FREDA is an open-source and readily available web application that allows users to explore and make statistically valid conclusions about their FT-MS data. The application is available online (https://map.emsl.pnnl.gov/app/freda) with a tutorial web series (https://youtu.be/k5HLE2kNSBY?si=yB6sGoyvzxrFf5MP) and freely accessible code on Github (https://github.com/EMSL-Computing/FREDA).
A microextraction (ME) sampling system, paired with inductively coupled plasma-mass spectrometry (ICP-MS), was employed to spatially analyze proteins tagged with lanthanum (La), gadolinium (Gd), or terbium (Tb) on the surface of western blot paper. The proteins were covalently tagged, separated via gel electrophoresis, and transferred to western blot paper for analysis by ME-ICP-MS. The ME-ICP-MS method enables the direct sampling of the tagged species on the western blot paper, without any sample preparation. Traditionally, the tagged analyte would need to be stained, excised, and digested to be analyzed by ICP-MS for its elemental and isotopic characterization. Preliminary detection limits for the ME-ICP-MS method applied to western blot paper were established to be 564, 54, and 2.5 fg for La, Gd, and Tb, respectively. The developed ME-ICP-MS method was compared to laser ablation (LA) ICP-MS, another direct solid sampling technique; it was readily determined that ME-ICP-MS can effectively map the elemental constituents on the western blot paper with comparable analysis time and measurement sensitivity. The analysis time per 2 × 4 mm extraction is ∼1 minute; if protein spots are directly targeted (rather than systematically mapping the entire blot paper), the analysis time per protein spot is ∼1 min. This developed method proved to be fast, effective, and accessible for correlating protein molecular weight with the detection of the inorganic tagant. The ME-ICP-MS approach could be widely applicable in research areas that involve metal-tagged protein bioconjugates, such as in the development of diagnostic and therapeutic agents and other biochemical probes.