Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSPHERES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Graphene Wrapped FeSe 2 Nano–Microspheres with High Pseudocapacitive Contribution for Enhanced Na–Ion Storage

Pseudocapacitance is a Faradaic process that involves surface or near surface redox reactions. Increasing the pseudocapacitive contribution is one of the most effective means to improve the rate performance of electrode materials. In this study, graphene oxide is used as a template to in situ synthesize burr globule–like FeSe 2 /graphene hybrid (B–FeSe 2 /G) using a facile one–step hydrothermal method. Structural characterization demonstrates that graphene layers not only wrap the surfaces of FeSe 2 particles, but also stretch into the interior of these particles, as a result of which the unique nano–microsphere structure is successfully established. When serving as anode material for Na–ion batteries, B–FeSe 2 /G hybrid displays high electrochemical performance in the voltage range of 0.5–2.9 V. The B–FeSe 2 /G hybrid has high reversible capacity of 521.6 mAh·g –1 at 1.0 A g –1 . Meanwhile, after 400 cycles, high discharge capacity of 496.3 mAh g –1 is obtained at a rate of 2.5 A g –1 , with a high columbic efficiency of 96.6% and less than 1.0% loss of discharge capacity. Even at the ultrahigh rate of 10 A g –1 , a specific capacity of 316.8 mAh g –1 can be achieved. Furthermore, kinetic analyses reveal that the excellent performance of the B–FeSe 2 /G hybrid is largely attributed to the high pseudocapacitive contribution induced by the special nano–micro structure.

25 ENERGY STORAGE↗

Embolization Materials Made of Gelatin: Comparison Between Gelpart and Gelatin Microspheres

Purpose:The object of this study was to assess the level of embolization in the embolized artery and the degradation period of these two embolic agents in the renal arteries using rabbit models.Materials and Methods: The renal artery was embolized using 5 mg of gelatin microspheres (GMSs; diameter, 35-100 {mu}m; group 1) or 1 mg of Gelpart (diameter, 1 mm; group 2). For each group, angiographies were performed on two kidneys immediately after the embolic procedure and on days 3, 7, and 14 after embolization. This was followed by histopathological examinations of the kidneys.Results:Follow-up angiograms on each day revealed the persistence of poorly enhanced wedge-shaped areas in the parenchymal phase in all cases. In group 1, four of six cases showed poorly enhanced small areas in the follow-up angiograms. In group 2, all cases showed poorly enhanced large areas. In the histopathological specimens, it was observed that immediately after embolization, the particles reached the interlobular arteries in group 1 and the interlobar arteries in group 2. In all cases in group 1, the particles were histologically identified even on day 14. In one case in group 2 on day 14, the particles were not identified.Conclusion:In conclusion, although GMSs and Gelpart were similar in the point of gelatin particles, the level of embolization and the degradation period were different between GMSs and Gelpart.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Observation of Intravascular Changes of Superabsorbent Polymer Microsphere (SAP-MS) with Monochromatic X-Ray Imaging

This study was designed to evaluate the intravascular transformation behavior of superabsorbent polymer microsphere (SAP-MS) in vivo macroscopically by using monochromatic X-ray imaging and to quantitatively compare the expansion rate of SAP-MS among different kinds of mixtures. Fifteen rabbits were used for our study and transcatheter arterial embolization (TAE) was performed for their auricular arteries using monochromatic X-ray imaging. We used three kinds of SAP-MS (particle diameter 100-150 {mu}m) mixture as embolic spherical particles: SAP-MS(H) absorbed with sodium meglumine ioxaglate (Hexabrix 320), SAP-MS(V) absorbed with isosmolar contrast medium (Visipaque 270), and SAP-MS(S) absorbed with 0.9% sodium saline. The initial volume of SAP-MS particles just after TAE and its final volume 10 minutes after TAE in the vessel were measured to calculate the expansion rate (ER) (n = 30). Intravascular behavior of SAP-MS particles was clearly observed in real time at monochromatic X-ray imaging. Averaged initial volumes of SAP-MS (H) (1.24 x 10{sup 7} {mu}m{sup 3}) were significantly smaller (p < 0.001) than those of SAP-MS (V) (5.99 x 10{sup 7} {mu}m{sup 3}) and SAP-MS (S) (5.85 x 10{sup 7} {mu}m{sup 3}). Averaged final volumes of SAP-MS (H) were significantly larger than averaged initial volumes (4.41 x 10{sup 7} {mu}m{sup 3} vs. 1.24 x 10{sup 7} {mu}m{sup 3}; p < 0.0001, ER = 3.55). There were no significant difference between averaged final volumes and averaged initial volumes of SAP-MS (V) and SAP-MS (S). SAP-MS (H), which first travels distally, reaches to small arteries, and then expands to adapt to the vessel lumen, is an effective particle as an embolic agent, causing effective embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hepatic Arterial Embolization with Doxorubicin-Loaded Superabsorbent Polymer Microspheres in a Rabbit Liver Tumor Model

Objectives: The pharmacokinetic profile after hepatic arterial embolization with superabsorbent microspheres (QuadraSpheres) loaded with doxorubicin was studied. Methods: Rabbits with hepatic VX2 tumors were treated with intra-arterial administration of QuadraSpheres loaded with doxorubicin, or transarterial chemoembolization (TACE) using doxorubicin, Lipiodol and Embospheres, or hepatic arterial infusion (HAI) of doxorubicin. Tumor specimens were evaluated by fluorescence microscopy, and plasma and tumor concentrations of doxorubicin were measured. Results: The peak plasma concentration of doxorubicin was lower in the QuadraSphere group (309.9 ng/ml) than in the HAI (673.4 ng/ml) or TACE (360.5 ng/ml) groups, suggesting higher tumor retention in the QuadraSphere group. Intratumoral doxorubicin levels declined to negligible levels at 1 and 3 days after treatment, respectively, in the HAI and TACE groups. In the QuadraSphere groups, intratumoral doxorubicin level declined after day 1, but was still detectable at 14 days after treatment and was higher than that in the other groups at 1, 3, and 7 days. Intratumoral doxorubicin fluorescence was detected at all time points in the QuadraSphere group, but only at 1 day after treatment in the TACE group. Conclusions: Hepatic arterial administration of doxorubicin-loaded QuadraSpheres enables the sustained release of doxorubicin to hepatic tumors.

60 APPLIED LIFE SCIENCES↗

Optimization of Doxorubicin Loading for Superabsorbent Polymer Microspheres: in vitro Analysis

Purpose: This study was designed to establish the ability of super-absorbent polymer microspheres (SAP) to actively uptake doxorubicin and to establish the proof of principle of SAP's ability to phase transfer doxorubicin onto the polymer matrix and to elute into buffer with a loading method that optimizes physical handling and elution characteristics. Methods: Phase I: 50-100 {mu}m SAP subject to various prehydration methods (normal saline 10 cc, hypertonic saline 4 cc, iodinated contrast 10 cc) or left in their dry state, and combined with 50 mg of clinical grade lyophilized doxorubicin reconstituted with various methods (normal saline 10 cc and 25 cc, sterile water 4 cc, iodinated contrast 5 cc) were placed in buffer and assessed based on loading, handling, and elution utilizing high-performance liquid chromatography (HPLC). Phase II: top two performing methods were subject to loading of doxorubicin (50, 75, 100 mg) in a single bolus (group A) or as a serial loading method (group B) followed by measurement of loading vs. time and elution vs. time. Results: Phase I revealed the most effective loading mechanisms and easiest handling to be dry (group A) vs. normal saline prehydrated (group B) SAP with normal saline reconstituted doxorubicin (10 mg/mL) with loading efficiencies of 83.1% and 88.4%. Phase II results revealed unstable behavior of SAP with 100 mg of doxorubicin and similar loading/elution profiles of dry and prehydrated SAP, with superior handling characteristics of group B SAP at 50 and 75 mg. Conclusions: SAP demonstrates the ability to load and bulk phase transfer doxorubicin at 50 and 75 mg with ease of handling and optimal efficiency through dry loading of SAP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Pilot Study of Uterine Artery Embolization with Tris-Acryl Gelatin Microspheres in Guinea Pigs

Objective: This study was designed to establish guinea pigs as an animal model for uterine artery embolization (UAE) with tris-acryl gelatin microspheres (TAGM). Methods: Twenty-five female adult guinea pigs were randomly divided into two groups, including a uterine artery casting mould group (n = 10) and a UAE group (n = 15). Pelvic angiography and vascular casting mould were performed in the first group. The anatomical characters of the pelvic cavity in guinea pigs were described. In the second group, the technical feasibility of performing UAE with TAGM in guinea pigs was investigated. The histopathological slides of the uterus of guinea pigs after UAE were examined to inspect the outcomes of UAE. Results: The uterine artery springs from the internal iliac artery, ascends tortuously along the cervix, and gives off vertically 8-10 branches to the cervix uteri and uterine horns. The diameters of the trunk of the uterine artery and its first branch were 0.32 {+-} 0.027 mm and 0.14 {+-} 0.01 mm, respectively. For UAE animals, the dosages of 40-120 and 100-300 {mu}m TAGM were 0.033 {+-} 0.003 ml and 0.015 {+-} 0.002 ml, respectively. On histopathological slides, embosphere particles were found in the first branches of the uterine artery, the subserous arteries, and the intramural arteries. Inflammatory reactions in the uterus were common in guinea pigs after UAE. Local or dispersed areas of necrosis in uterus also were observed in a few guinea pigs. Conclusions: Guinea pigs are an appropriate and feasible model for UAE with TAGM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Changes in Normal Liver and Spleen Volume after Radioembolization with {sup 90}Y-Resin Microspheres in Metastatic Breast Cancer Patients: Findings and Clinical Significance

Purpose: In clinical trials with yttrium-90-resin-microspheres for the management of colorectal cancer liver metastases, it was observed that radioembolization might result in splenomegaly and an increase in portal vein size. Subclinical hepatitis in normal liver tissue as well as the effects of radioembolization and prior chemotherapy are suspected to be responsible for this phenomenon. The purpose of this study was to quantify the changes in liver and spleen volume and portal vein diameter after radioembolization. Methods: Twenty-seven patients with liver-dominant metastatic disease from breast cancer who had not responded to chemotherapy or had to abandon chemotherapy because of its toxic effects were evaluated. Changes in liver and spleen volume and portal vein diameter as well as liver tumor volume and diameter were quantified using computed tomography scans. Results: Radioembolization was associated with a significant mean decrease in the whole liver volume of 10.2% (median 16.7%; P = 0.0024), mainly caused by a reduction in the right lobe volume (mean 16.0%; P < 0.0001). These changes were accompanied by a significant increase in the diameter of the main portal vein (mean 6.8%; P < 0.0001) as well as splenic volume (mean 50.4%; P < 0.0001). Liver-tumor volume and diameter decreased by a median of 24 and 39.7%. Conclusions: Radioembolization is an effective treatment for tumor size reduction in patients with breast cancer liver metastases. Treatment is associated with changes of hepatic parenchymal volume, splenic volume, and portal vein size that appear not to represent clinically important sequelae in this patient cohort.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effectiveness of Repeat Angiographic Assessment in Patients Designated for Radioembolization Using Yttrium-90 Microspheres With Initial Extrahepatic Accumulation of Technitium-99m Macroaggregated Albumin: A Single Center's Experience

Purpose: To evaluate the efficacy of a workflow consisting of repeat assessment in patients planned for yttrium-90 ({sup 90}Y) radioembolization in case of nontarget visceral technetium-99m ({sup 99m}Tc)-macroaggregated albumin (MAA) accumulation despite initial prophylactic coil embolization of nonhepatic arteries. Materials and Methods: In 341 patients with primary and secondary liver cancer, pretreatment hepatic angiograms, as well as single-photon emission computed tomography coregistered with magnetic resonance imaging scans, were obtained. Extrahepatic tracer deposition was identified in 33 patients (9.7%) necessitating repeat assessment. Images were reviewed to correlate the site of MAA accumulation with causative gastrointestinal vessels, and repeat angiograms served as reference standard. Results: At repeat angiography, the source of extrahepatic flow was identified and eliminated in 31 of 33 patients (93.9%). In 20 patients (60.6%), successful embolization of nontarget vessels was achieved, in 13 patients (39.4%), MAA was administered more distally. Afterward, extrahepatic MAA deposition was eliminated in 30 patients (90.9%). Conclusion: The algorithm of repeat assessment in case of extrahepatic MAA accumulation has proven highly effective to eliminate extrahepatic shunting, thus decreasing the risk of postradioembolization complications due to inadvertent visceral microsphere deposition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Survival After Accidental Extrahepatic Distribution of Y90 Microspheres to the Mesentery During a Radioembolization Procedure

We present the acute management and outcome of a patient after an accidental mesenteric distribution of Y90 microspheres during radioembolization (RE). This report describes and highlights: (1) the incidence of a significant reflux during a RE session while injecting into a replaced right hepatic artery from the superior mesenteric artery, (2) the appearance of diffuse mesenteric Y90 distribution in bremsstrahlung-imaging, (3) the management protocol with the radiation protection agent amifostine, (4) the development of typical adverse effects in the expected time window, and (5) survival of the patient without long-term sequelae. This report should sensitize physicians to this particular problem and may help to avoid as well as manage similar radioembolization incidences.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gelatin Microspheres: Correlation between Embolic Effect/Degradability and Cross-linkage/Particle Size

PurposeTo evaluate the embolic effect and degradability of gelatin microspheres (GMS) using various degrees of cross-linkage and particle sizes in rabbit renal artery embolization.MethodsFour types of GMS were used, as follows: 2 types of cross-linkage and 2 types of particle size. Twenty-four rabbits (6 in each group) were used for the renal artery embolization. Renal angiography was performed before and after embolization of right renal artery. Follow-up renal angiography was performed 2 days (n = 2), 5 days (n = 2), and 15 days (n = 2) after embolization in each group, and then kidneys were removed for histopathological evaluation. Vascular areas of the angiography were measured by Image J software, and the reperfusion rate was calculated. In renal specimens, residual GMS were checked and the degree of degradation was classified according to a 4-point scale.ResultsThe mean amounts of large- and small-particle-size GMS injected were 15.0 and 34.3 mg, respectively. Tissue necrosis was confirmed in each group; however, no difference was observed among groups. Renal reperfusion was observed more with small GMS than with large GMS. Renal reperfusion was also observed more with low cross-linked GMS than with high cross-linked GMS. In histopathological specimens, large GMS were confirmed in lobar artery, and small GMS were confirmed in lobular artery. Low cross-linked GMS completely degraded 15 days after embolization. In contrast, high cross-linked GMS were persistent 15 days after embolization.ConclusionDegree of cross-linkage and particle size affected degradability and reperfusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temporary Arterial Embolization of Liver Parenchyma with Degradable Starch Microspheres (EmboCept{sup ®}S) in a Swine Model

BackgroundThis study aimed to evaluate the embolic properties, time to reperfusion, and histologic changes in temporary embolization of liver tissue with degradable starch microspheres (DSM) in a swine model.MethodsIn four adult minipigs, DSMs were injected into the right or left hepatic artery on the lobar level until complete stasis of the blood flow was detectable angiographically. The time required to complete angiographically determined reperfusion was noted. The animals were killed 3 h after complete reperfusion, and samples were taken from the liver. Histologic examinations of the embolized liver parenchyma and untreated tissue were performed.ResultsHepatic arterial embolization using DSMs was technically successful in all cases, with complete blood flow stasis shown by control angiography. A single vial of DSMs (450 mg/7.5 ml) was sufficient to embolize a whole liver lobe in all cases. Angiography showed complete reconstitution of hepatic arterial perfusion after a mean time to reperfusion of 32 ± 6.1 min (range, 26–39 min). Hematoxylin and eosin staining showed no histologically detectable differences between untreated tissue and parenchyma embolized with DSMs except for mild sinusoidal congestion in one case. Indirect in situ DNA nick end labeling staining (TUNEL) showed only single positive hepatocytes, indicating apoptosis.ConclusionTemporary embolization of the hepatic artery using DSMs is feasible with complete reperfusion after 30 min in pigs. Even after complete arterial blood flow stasis, no extensive tissue damage to the embolized liver parenchyma was observed at histologic examinations in this short-term study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pharmacokinetics, Safety, and Efficacy of Chemoembolization with Doxorubicin-Loaded Tightly Calibrated Small Microspheres in Patients with Hepatocellular Carcinoma

PurposeThis study examines safety, efficacy, and pharmacokinetics of chemoembolization with loadable microspheres ≤100 μm for hepatocellular carcinoma.Materials and MethodsA pilot safety study was performed in 19 patients with size and dose escalation and then 52 patients were enrolled prospectively and randomly assigned to chemoembolization with TANDEM™ loaded with 150 or 100 mg of doxorubicin.ResultsThe mean diameter of the tumors was 7.28 ± 2.09 cm (range 4–12) and distribution dominant/multiple 51.9/48.1 %. Child A/B distribution was 32/20 (61.5/38.5 %) and etiology HBV/HCV/HBV/HCV-hemochromatosis was 61.6/9.6/9.6/15.4 %. Twenty-five patients were assigned in the low and 27 in the high loading group. There was 1.92 % thirty-day mortality due to lesion rupture. Biliary damage was seen in 3 patients (5.7 %) in the high loading. Mean maximum plasma concentration of doxorubicin C{sub max} ± SD was 284.9 ± 276.2 ng/mL for the high and 108.5 ± 77.6 ng/mL for the low loading (p < 0.001). According to m-RECIST overall objective response after two sessions reached 61.22 and 63.82 % at 6 months. Notably, complete target lesion response (CR) after the second session was observed in 28.57 % and maintained in 23.40 % at 6 months. No statistical differences in the local response rates were observed between the two loading groups. Overall survival (OS) at 6 months, 1 , 2, and 3 years was 98.08, 92.3, 88.46, and 82.6 %, respectively. OS and Progression-Free Survival did not demonstrate statistical significance between the two loading groups.ConclusionInitial evidence shows that (a) TANDEM™ achieves high rates of local response and mid-term survival, (b) high loading provides no clinical benefit and is associated with biliary toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiofrequency Ablation Combined with Hepatic Arterial Chemoembolization Using Degradable Starch Microsphere Mixed with Mitomycin C for the Treatment of Liver Metastasis from Colorectal Cancer: A Prospective Multicenter Study

PurposeThis phase II prospective study investigates possible benefits of radiofrequency ablation (RFA) combined with hepatic arterial chemoembolization using degradable starch microsphere (DSM) mixed with mitomycin C (MMC) in non-surgical candidates with colorectal liver metastases.Materials and MethodsThis study, approved by the respective institutional review board, included non-surgical candidates with 3 or fewer liver tumors of 3 cm or smaller, or a single lesion 5 cm or smaller. Percutaneous RFA was performed immediately after chemoembolization using DSM-MMC. Primary and secondary endpoints were the local tumor control rate, safety, and 2-year recurrence-free and overall survival rates.ResultsThis study examined 25 patients (22 males, 3 females) with 38 tumors of mean maximum diameter of 2.2 ± 0.9 cm (standard deviation) (range 1.0–4.2 cm). Their mean age was 70.2 ± 8.2 years (range 55–82 years). Local tumor progression developed in 3 tumors (7.9%, 3/38) of 3 patients (12%, 3/25) during the mean follow-up of 34.9 ± 9.2 months (range 18.3–50.1 months). The 2-year local tumor control rates were 92.0% [95% confidence interval (CI), 81.4–100%] on a patient basis and 94.6% (95% CI, 87.3–100%) on a tumor basis. The respective 2-year overall and recurrence-free survival rates were 88.0% (95% CI, 75.3–98.5%) and 63.3% (95% CI, 44.2–82.5%), with median survival time of 48.4 months. Fever was the only adverse event requiring treatments in 2 patients (8%).ConclusionsThis combination therapy is safe, exhibiting strong anticancer effects on colorectal liver metastasis, which might contribute to patient survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward Transpulmonary Chemoembolization with Degradable Starch Microspheres: Systematic Analysis of Local and Systemic Effects in a Porcine Model

Purpose: To investigate local and systemic effects of transpulmonary chemoembolization (TPCE) with degradable starch microspheres (DSM) and doxorubicin. The long-term goal is to establish DSM-TPCE as a treatment option for pulmonary malignancies. Materials and Methods: Nine pigs underwent TPCE of either the right or left lower lobe pulmonary artery (LLPA) and bland embolization (TPE) of the contralateral LLPA. Before the procedures, macroaggregated albumin (MAA) particles were injected into both LLPAs, to exclude systemic shunting. Pulmonary arterial pressure, heart rate and oxygenation were recorded immediately before and at 1, 3, 5 and 10 min after treatment. To investigate possible nontarget embolization, animals underwent cerebral MRI (cMRI). We killed the animals after a contrast-enhanced chest computed tomography (CT) and performed a pathologic examination at 12 h (3), 24 h (3) and 72 h (3) after treatment. Results: All experiments were technically successful. Mean injected DSM dose until stasis was similar in TPCE and TPE (4.3 ± 1.4 vs. 4.0 ± 1.4 mL). Pulmonary arterial pressure increased significantly 3 min after treatment (TPE: 17 ± 5 vs. 27 ± 7 mmHg; TPCE: 22 ± 6 vs. 36 ± 8 mmHg). No significant changes in heart rate or peripheral oxygenation levels occurred. We observed no evidence of structural lung damage or permanent perfusion disruption on CT. MAA test injection and cMRI revealed no shunting or nontarget embolization. The pathologic assessment revealed nonspecific local inflammation of the lung parenchyma. Conclusion: In this large-animal model, TPCE and TPE appear feasible and safe. We observed a mild increase in pulmonary arterial pressure. Nontarget embolization did not occur. TPCE, as well as TPE, did not cause structural damage to the normal lung parenchyma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Nanoparticles Impregnated, Cross-Linked, Porous Chitosan Microspheres for Efficient Adsorption of Methylene Blue from Pharmaceutical Waste Water

The study demonstrates the preparation of MnFe{sub 2}O{sub 4} impregnated chitosan-microspheres (CMMS) as adsorbents for efficient removal of cationic thiazine dye, methylene blue. A facile approach with great economic and technical advantages to obtain highly crystalline manganese ferrite nanoparticles by solution combustion method is accounted. CMMS were characterized and evaluated for MB adsorption using linear forms of Freundlich and Langmuir adsorption isotherms, pseudo-first order, pseudo-second order and Elovich kinetic models. Application of CMMS to pharmaceutical waste, desorption of MB and reusability of CMMS are reported. Significantly, MB concentration in treated real sample was reduced by ~ 18 times to that of initial concentration. Graphic Abstract: .

36 MATERIALS SCIENCE↗

Same solution synthesis and self-assembly of porous silica nanoparticles into microspheres

The ability to couple self-assembly to the synthesis of materials in situ is an attractive concept for both basic and applied research. Self-assembly has been demonstrated for dense solid building blocks; however, it remains underdeveloped for porous materials, especially in situ assembly. Herein, we report the one-step synthesis and self-assembly of porous silica nanoparticles into silica microspheres by using polyvinylpyrrolidone-pentanol emulsion droplet system. Furthermore, nanoparticle size can be tuned by modifying the reaction conditions.

36 MATERIALS SCIENCE↗

A multiscale phase field fracture approach based on the non-affine microsphere model for rubber-like materials

Rubber-like materials have a broad scope of applications due to their unique properties like high stretchability and increased toughness. Hence, computational models for simulating their fracture behavior are paramount for designing them against failures. In this study, the phase field fracture approach is integrated with a multiscale polymer model for predicting the fracture behavior in elastomers. At the microscale, damaged polymer chains are modeled to be made up of a number of elastic chain segments pinned together. Using the phase field approach, the damage in the chains is represented using a continuous variable. Both the bond stretch internal energy and the entropic free energy of the chain are assumed to drive the damage, and the advantages of this assumption are expounded. A framework for utilizing the non-affine microsphere model for damaged systems is proposed here by considering the minimization of a hypothetical undamaged free energy, ultimately connecting the chain stretch to the macroscale deformation gradient. At the macroscale, a thermodynamically consistent formulation is derived in which the total dissipation is assumed to be mainly due to the rupture of molecular bonds. Using a monolithic scheme, the proposed model is numerically implemented and the resulting three-dimensional simulation predictions are compared with existing experimental data. The capability of the model to qualitatively predict the propagation of complex crack paths and quantitatively estimate the overall fracture behavior is verified. Additionally, the effect of the length scale parameter on the predicted fracture behavior is studied for an inhomogeneous system.

97 MATHEMATICS AND COMPUTING↗

Magnetic Resonance Imaging-Based Radiation-Absorbed Dose Estimation of {sup 166}Ho Microspheres in Liver Radioembolization

Purpose: To investigate the potential of magnetic resonance imaging (MRI) for accurate assessment of the three-dimensional {sup 166}Ho activity distribution to estimate radiation-absorbed dose distributions in {sup 166}Ho-loaded poly (L-lactic acid) microsphere ({sup 166}Ho-PLLA-MS) liver radioembolization. Methods and Materials: MRI, computed tomography (CT), and single photon emission CT (SPECT) experiments were conducted on an anthropomorphic gel phantom with tumor-simulating gel samples and on an excised human tumor-bearing liver, both containing known amounts of {sup 166}Ho-PLLA-MS. Three-dimensional radiation-absorbed dose distributions were estimated at the voxel level by convolving the {sup 166}Ho activity distribution, derived from quantitative MRI data, with a {sup 166}Ho dose point-kernel generated by MCNP (Monte Carlo N-Particle transport code) and from Medical Internal Radiation Dose Pamphlet 17. MRI-based radiation-absorbed dose distributions were qualitatively compared with CT and autoradiography images and quantitatively compared with SPECT-based dose distributions. Both MRI- and SPECT-based activity estimations were validated against dose calibrator measurements. Results: Evaluation on an anthropomorphic phantom showed that MRI enables accurate assessment of local {sup 166}Ho-PLLA-MS mass and activity distributions, as supported by a regression coefficient of 1.05 and a correlation coefficient of 0.99, relating local MRI-based mass and activity calculations to reference values obtained with a dose calibrator. Estimated MRI-based radiation-absorbed dose distributions of {sup 166}Ho-PLLA-MS in an ex vivo human liver visually showed high correspondence to SPECT-based radiation-absorbed dose distributions. Quantitative analysis revealed that the differences in local and total amounts of {sup 166}Ho-PLLA-MS estimated by MRI, SPECT, and the dose calibrator were within 10%. Excellent agreement was observed between MRI- and SPECT-based dose-volume histograms. Conclusions: Quantitative MRI was demonstrated to provide accurate three-dimensional {sup 166}Ho-PLLA-MS activity distributions, enabling localized intrahepatic radiation-absorbed dose estimation by convolution with a {sup 166}Ho dose point-kernel for liver radioembolization treatment optimization and evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗