Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSCOPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Development of micro-four-point probe in a scanning tunneling microscope for in situ electrical transport measurement

Electrons at surface may behave differently from those in bulk of a material. Multi-functional tools are essential in comprehensive studies on a crystal surface. Here, we developed an in situ microscopic four-point probe (4PP) transport measurement system on the basis of a scanning tunneling microscope (STM). In particular, convenient replacement between STM tips and micro-4PPs enables systematic investigations of surface morphology, electronic structure, and electrical transport property of a same sample surface. Performances of the instrument are demonstrated with high-quality STM images, tunneling spectra, and low-noise electrical I-V characteristic curves of a single-layer FeSe film grown on a conductive SrTiO{sub 3} surface.

36 MATERIALS SCIENCE↗

On the microscopic fluctuations driving the NMR relaxation of quadrupolar ions in water

Nuclear Magnetic Resonance (NMR) relaxation is sensitive to the local structure and dynamics around the probed nuclei. The Electric Field Gradient (EFG) is the key microscopic quantity to understand the NMR relaxation of quadrupolar ions, such as {sup 7}Li{sup +}, {sup 23}Na{sup +}, {sup 25}Mg{sup 2+}, {sup 35}Cl{sup −}, {sup 39}K{sup +}, or {sup 133}Cs{sup +}. Using molecular dynamics simulations, we investigate the statistical and dynamical properties of the EFG experienced by alkaline, alkaline Earth, and chloride ions at infinite dilution in water. Specifically, we analyze the effect of the ionic charge and size on the distribution of the EFG tensor and on the multi-step decay of its auto-correlation function. The main contribution to the NMR relaxation time arises from the slowest mode, with a characteristic time on the picosecond time scale. The first solvation shell of the ion plays a dominant role in the fluctuations of the EFG, all the more that the ion radius is small and its charge is large. We propose an analysis based on a simplified charge distribution around the ion, which demonstrates that the auto-correlation of the EFG, hence the NMR relaxation time, reflects primarily the collective translational motion of water molecules in the first solvation shell of the cations. Our findings provide a microscopic route to the quantitative interpretation of NMR relaxation measurements and open the way to the design of improved analytical theories for NMR relaxation for small ionic solutes, which should focus on water density fluctuations around the ion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Commissioning of the PRIOR proton microscope

Recently, a new high energy proton microscopy facility PRIOR (Proton Microscope for FAIR Facility for Anti-proton and Ion Research) has been designed, constructed, and successfully commissioned at GSI Helmholtzzentrum für Schwerionenforschung (Darmstadt, Germany). As a result of the experiments with 3.5–4.5 GeV proton beams delivered by the heavy ion synchrotron SIS-18 of GSI, 30 μm spatial and 10 ns temporal resolutions of the proton microscope have been demonstrated. A new pulsed power setup for studying properties of matter under extremes has been developed for the dynamic commissioning of the PRIOR facility. This study describes the PRIOR setup as well as the results of the first static and dynamic protonradiography experiments performed at GSI.

36 MATERIALS SCIENCE↗

Microscopic model for all optical switching in ferromagnets

The microscopic mechanism behind the all optical switching (AOS) in ferromagnets has triggered intense scientific debate. Here, the microscopic three-temperature model is utilized to describe AOS in a perpendicularly magnetized ferromagnetic Co/Pt system. We demonstrate that AOS in such a ferromagnet can be explained with the Inverse Faraday Effect (IFE). The influence of the strength and lifetime of the IFE induced field pulse on the switching process are investigated. We found that because of strong spin-orbit coupling, the minimal lifetime of the IFE needed to obtain switching is of the order of 0.1 ps, which is shorter than previously assumed. Moreover, spatial images of the domain pattern after AOS in Co/Pt, as well as their dependence on applying an opposite magnetic field, are qualitatively reproduced.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microscopic molecular dynamics characterization of the second-order non-Navier-Fourier constitutive laws in the Poiseuille gas flow

The second-order non-Navier-Fourier constitutive laws, expressed in a compact algebraic mathematical form, were validated for the force-driven Poiseuille gas flow by the deterministic atomic-level microscopic molecular dynamics (MD). Emphasis is placed on how completely different methods (a second-order continuum macroscopic theory based on the kinetic Boltzmann equation, the probabilistic mesoscopic direct simulation Monte Carlo, and, in particular, the deterministic microscopic MD) describe the non-classical physics, and whether the second-order non-Navier-Fourier constitutive laws derived from the continuum theory can be validated using MD solutions for the viscous stress and heat flux calculated directly from the molecular data using the statistical method. Peculiar behaviors (non-uniform tangent pressure profile and exotic instantaneous heat conduction from cold to hot [R. S. Myong, “A full analytical solution for the force-driven compressible Poiseuille gas flow based on a nonlinear coupled constitutive relation,” Phys. Fluids 23(1), 012002 (2011)]) were re-examined using atomic-level MD results. It was shown that all three results were in strong qualitative agreement with each other, implying that the second-order non-Navier-Fourier laws are indeed physically legitimate in the transition regime. Furthermore, it was shown that the non-Navier-Fourier constitutive laws are essential for describing non-zero normal stress and tangential heat flux, while the classical and non-classical laws remain similar for shear stress and normal heat flux.

42 ENGINEERING↗

A sensitive EUV Schwarzschild microscope for plasma studies with sub-micrometer resolution

We present an extreme ultraviolet (EUV) microscope using a Schwarzschild objective which is optimized for single-shot sub-micrometer imaging of laser-plasma targets. The microscope has been designed and constructed for imaging the scattering from an EUV-heated solid-density hydrogen jet. Here, imaging of a cryogenic hydrogen target was demonstrated using single pulses of the free-electron laser in Hamburg (FLASH) free-electron laser at a wavelength of 13.5 nm. In a single exposure, we observe a hydrogen jet with ice fragments with a spatial resolution in the sub-micrometer range. In situ EUV imaging is expected to enable novel experimental capabilities for warm dense matter studies of micrometer-sized samples in laser-plasma experiments.

42 ENGINEERING↗

Comparative microscopic dynamics in a room-temperature ionic liquid confined in carbon pores characterized by reversible and irreversible ion immobilization

In search for the origin of irreversible ion immobilization under applied electric potential recently reported for a prototypical room-temperature ionic liquid electrolyte, [emim][Tf 2 N], confined in 1.5 nm carbon pores, here we compare the microscopic dynamics of cations in [emim][Tf 2 N] in the 1.5 nm and 6.7 nm carbon pores; in the latter, ion immobilization under applied electric potential is reversible. Using quasielastic neutron scattering, we find that the cation translational diffusivity is reasonably well defined on at least a nanometer length scale in the 6.7 nm pores, but not the 1.5 nm pores. Severely impeded microscopic dynamics of the confined electrolyte may be one of the factors differentiating the 1.5 nm pores from their larger counterparts and contributing to the irreversible immobilization of ions under applied electric potential.

Mamontov, Eugene↗

Laser-free GHz stroboscopic transmission electron microscope: Components, system integration, and practical considerations for pump–probe measurements

In this work a 300 keV transmission electron microscope was modified to produce broadband pulsed beams that can be, in principle, between 40 MHz and 12 GHz, corresponding to temporal resolution in the nanosecond to picosecond range without an excitation laser. The key enabling technology is a pair of phase-matched modulating and de-modulating traveling wave metallic comb striplines (pulsers). An initial temporal resolution of 30 ps was achieved with a strobe frequency of 6.0 GHz. The placement of the pulsers, mounted immediately below the gun, allows for preservation of all optical configurations, otherwise available to the unmodified instrument, and therefore makes such a post-modified instrument for dual-use, i.e., both pulsed-beam mode (i.e., stroboscopic time-resolved) and conventional continuous waveform mode. In this article, we describe the elements inserted into the beam path, challenges encountered during integration with an in-service microscope, and early results from an electric-field-driven pump–probe experiment. We conclude with ideas for making this class of instruments broadly applicable for examining cyclical and repeatable phenomena.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Precision-controlled ultrafast electron microscope platforms. A case study: Multiple-order coherent phonon dynamics in 1T-TaSe2 probed at 50 fs–10 fm scales

We report on the first detailed beam tests attesting the fundamental principle behind the development of high-current-efficiency ultrafast electron microscope systems where a radio frequency (RF) cavity is incorporated as a condenser lens in the beam delivery system. To allow for the experiment to be carried out with a sufficient resolution to probe the performance at the emittance floor, a new cascade loop RF controller system is developed to reduce the RF noise floor. Temporal resolution at 50 fs in full-width-at-half-maximum and detection sensitivity better than 1% are demonstrated on exfoliated 1T-TaSe2 system under a moderate repetition rate. To benchmark the performance, multi-terahertz edge-mode coherent phonon excitation is employed as the standard candle. The high temporal resolution and the significant visibility to very low dynamical contrast in diffraction signals via high-precision phase-space manipulation give strong support to the working principle for the new high-brightness femtosecond electron microscope systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reconstruction and uncertainty quantification of lattice Hamiltonian model parameters from observations of microscopic degrees of freedom

The emergence of scanning probe and electron beam imaging techniques has allowed quantitative studies of atomic structure and minute details of electronic and vibrational structure on the level of individual atomic units. These microscopic descriptors, in turn, can be associated with local symmetry breaking phenomena, representing the stochastic manifestation of the underpinning generative physical model. In this work, we explore the reconstruction of exchange integrals in the Hamiltonian for a lattice model with two competing interactions from observations of microscopic degrees of freedom and establish the uncertainties and reliability of such analysis in a broad parameter-temperature space. In contrast to other approaches, we specifically specify a loss function inherent to thermodynamic systems and utilize it to estimate uncertainty in simulated realizations of different models. As an ancillary task, we develop a machine learning approach based on histogram clustering to predict phase diagrams efficiently using a reduced descriptor space. We further demonstrate that reconstruction is possible well above the phase transition and in the regions of parameter space when the macroscopic ground state of the system is poorly defined due to frustrated interactions. This suggests that this approach can be applied to the traditionally complex problems of condensed matter physics such as ferroelectric relaxors and morphotropic phase boundary systems, spin and cluster glasses, and quantum systems once the local descriptors linked to the relevant physical behaviors are known.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Toward the fabrication of a 5- μm -resolution Wolter microscope for the National Ignition Facility (invited)

Advancements in computer-controlled polishing, metrology, and replication have led to an x-ray mirror fabrication process that is capable of producing high-resolution Wolter microscopes. Here, we present the fabrication and test of a nickel–cobalt replicated full-shell x-ray mirror that was electroformed from a finely figured and polished mandrel. This mandrel was designed for an 8-m source-to-detector-distance microscope, with 10× magnification, and was optimized to reduce shell distortions that occur within 20 mm of the shell ends. This, in combination with an improved replication tooling design and refined bath parameters informed by a detailed COMSOL Multiphysics® model, has led to reductions in replication errors in the mirrors. Mandrel surface fabrication was improved by implementing a computer-controlled polishing process that corrected the low-frequency mandrel figure error and achieved <2.0 nm RMS convergence error. X-ray tests performed on a pair of mirror shells replicated from the mandrel have demonstrated <10 μm full-width at half-maximum (FWHM) spatial resolution. Here, we discuss the development process, highlight results from metrology and x-ray testing, and define a path for achieving a program goal of 5 μm FWHM resolution.

47 OTHER INSTRUMENTATION↗

A versatile high-speed x-ray microscope for sub-10 nm imaging

We have developed a next-generation scanning x-ray microscope RASMI (RApid Scanning Microscopy Instrument) for high-throughput tomographic imaging. RASMI is installed at the hard x-ray nanoprobe beamline at NSLS-II and is capable of manipulating 1D multilayer Laue lenses (MLLs) and 2D optics (both zone plates and monolithically assembled 2D MLLs). The sample scanning stage utilizes line-focusing interferometry as an encoder while performing fly-scanning data acquisition. The system can be configured for both position- and time-triggering modes during fly-scanning. The microscope demonstrated a detector-limited data acquisition rate of 1.25 kHz during ptychography measurements. The initial x-ray results yielded a sample-limited resolution of ∼6 nm in 2D. RASMI can be adopted for in-vacuum applications and is a foundation for the next-generation scanning microscopy systems to be developed and commissioned at NSLS-II.

36 MATERIALS SCIENCE↗

Ultrafast transmission electron microscope for studying the dynamics of the processes induced by femtosecond laser beams

We have developed an ultrafast transmission electron microscope for studying dynamic processes in samples excited by femtosecond laser pulses and for probing transient processes occurring under irradiation by a pulsed (∼7 ps) photoelectron beam with an adjustable delay with respect to the excitation pulse. A 75-keV photoelectron beam is formed using a silver photocathode irradiated by a femtosecond laser beam. This microscope is shown to have a high spatial resolution in the photoelectron regime: nanoscale in the imaging regime and atomic in the electron diffraction regime. It is used for experimental observation of ultrafast interaction of a laser-induced electron cloud with a pulsed photoelectron beam. Using this effect, a method of spatial and temporal alignment of excitation laser and probe electron pulsed beams on a sample is experimentally implemented. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bridging microscopic dynamics and rheology in the yielding of charged colloidal suspensions

The yielding of soft materials is critical to many natural and industrial processes, yet experimental insights into microscopic aspects of yielding are limited. This study combines angle X-ray scattering, X-ray photon correlation spectroscopy, and in situ rheology (Rheo-SAXS-XPCS) with fast lubrication dynamics simulations to examine how interparticle interactions influence yielding in charged colloidal suspensions. By tuning attraction through salt addition, we compare repulsive and attractive systems under deformation. Repulsive suspensions yield uniformly with Andrade-like creep and minimal structural change. In contrast, attractive suspensions show complex behaviors, including shear banding, delayed yielding, and resolidification, governed by transient dynamics at shear band interfaces. These results directly link microscopic particle dynamics to macroscopic flow and demonstrate how interaction potentials control rheological behavior. This work offers a framework for designing soft materials with tailored properties for applications in coatings, food processing, drug delivery, and other technologies requiring precise mechanical control.

Molecular Dynamics Simulation↗

High resolution tip-tilt positioning system for a next generation MLL-based x-ray microscope

Multilayer Laue lenses (MLLs) are x-ray focusing optics with the potential to focus hard x-rays down to a single nanometer level. In order to achieve point focus, an MLL microscope needs to have the capability to perform tip-tilt motion of MLL optics and to hold the angular position for an extended period of time. Here, we present a 2D tip-tilt system that can achieve an angular resolution of over 100 microdegree with a working range of 4°, by utilizing a combination of laser interferometer and mini retroreflector. The linear dimensions of the developed system are about 30 mm in all directions, and the thermal dissipation of the system during operation is negligible. Compact design and high angular resolution make the developed system suitable for MLL optics alignment in the next generation of MLL-based x-ray microscopes.

36 MATERIALS SCIENCE↗

Fungal drops: a novel approach for macro- and microscopic analyses of fungal mycelial growth

Abstract This study presents an inexpensive approach for the macro- and microscopic observation of fungal mycelial growth. The ‘fungal drops’ method allows to investigate the development of a mycelial network in filamentous microorganisms at the colony and hyphal scales. A heterogeneous environment is created by depositing 15–20 µl drops on a hydrophobic surface at a fixed distance. This system is akin to a two-dimensional (2D) soil-like structure in which aqueous-pockets are intermixed with air-filled pores. The fungus (spores or mycelia) is inoculated into one of the drops, from which hyphal growth and exploration take place. Hyphal structures are assessed at different scales using stereoscopic and microscopic imaging. The former allows to evaluate the local response of regions within the colony (modular behaviour), while the latter can be used for fractal dimension analyses to describe the hyphal network architecture. The method was tested with several species to underpin the transferability to multiple species. In addition, two sets of experiments were carried out to demonstrate its use in fungal biology. First, mycelial reorganization of Fusarium oxysporum was assessed as a response to patches containing different nutrient concentrations. Second, the effect of interactions with the soil bacterium Pseudomonas putida on habitat colonization by the same fungus was assessed. This method appeared as fast and accessible, allowed for a high level of replication, and complements more complex experimental platforms. Coupled with image analysis, the fungal drops method provides new insights into the study of fungal modularity both macroscopically and at a single-hypha level.

Buffi, Matteo↗

Microscopic, Biochemical, and Molecular Comparisons of Moderately Resistant and Susceptible Populus Genotypes Inoculated with Sphaerulina musiva

Sphaerulina musiva, the causal agent of Septoria leaf spot and stem canker, is responsible for mortality and yield loss in Populus plantations. However, little is known about the mode of infection and the mechanisms of resistance in this pathosystem. To characterize these phenomena, microscopic, biochemical, and transcriptome comparisons were performed between leaves of moderately resistant and susceptible genotypes of Populus inoculated with S. musiva conidia. Using scanning electron, cryofracture, and laser-scanning confocal microscopy, the infection and colonization of Populus leaves by S. musiva were examined across five time points (48 h, 96 h, 1 week, 2 weeks, and 3 weeks). The infection process was similar regardless of the host genotype. Differences in host colonization between susceptible and moderately resistant genotypes were apparent by 1 week postinoculation. However, the germination of conidia was greater on the susceptible than on the moderately resistant genotype (P < 0.008). Diaminobenzidine staining, a measure of hydrogen peroxide accumulation, was different (P < 0.001) between the host genotypes by 2 weeks postinoculation. Transcriptome differences between genotypes indicated that the speed and amplitude of the defense response were faster and more extensive in the moderately resistant genotype. Changes in gene expression support the microscopic and biochemical observations.

Plant Sciences↗

Microscopic scattering approach to in-gap states: Cr adatoms on superconducting 𝛽−Bi 2 ⁢Pd

We develop a microscopic scattering formalism to describe Yu-Shiba-Rusinov (YSR) states due to a single Cr adatom on the Bi-terminated surface of 𝛽−Bi 2 ⁢Pd, by combining ab initio Wannier functions with a real-space Green's function approach in the Bogoliubov–de Gennes formalism. Our framework reproduces key scanning tunneling spectroscopy features, including a single particle-hole asymmetric YSR peak and isotropic 𝑑⁢𝐼/𝑑⁢𝑉 maps around the impurity. Decomposing the YSR states reveals contributions from four nearly degenerate 𝐶 4⁢𝑣 representations, with energy broadening masking their individual signatures. Spin-orbit coupling induces partial spin polarization, while the spatial asymmetry between particle and hole components arises from Cr 𝑑−Bi 𝑝 hybridization. These results highlight the importance of realistic band structures and microscopic modeling for interpreting STM data and provide a foundation for studying impurity chains hosting topological excitations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗