RADIATION EFFECTS IN PHYSICAL AGING OF BINARY As-S AND As-Se GLASSES

Radiation-induced physical aging effects are studied in binary AsxS100-x and AsxSe100-x (30 ≤ x ≤ 42) glasses by conventional differential scanning calorimetry (DSC) method. It is shown that γ-irradiation (Co60 source, ~ 3 MGy dose) of glassy AsxS100-x caused a measurable increase in glass transition temperature and endothermic peak area in the vicinity of glass transition region, which was associated with acceleration of structural relaxation processes in these materials. In contrast to sulfide glasses, the samples of As-Se family did not exhibit any significant changes in DSC curves after γ-irradiation. The observed difference in radiation-induced physical aging between sulfides and selenides was explained by more effective destruction-polymerization transformations and possible metastable defects formation in S-based glassy network.

36 MATERIALS SCIENCE↗

In vitro bio-functionality of gallium nitride sensors for radiation biophysics

Highlights: Black-Right-Pointing-Pointer Gallium nitride based sensors show promising characteristics to monitor cellular parameters. Black-Right-Pointing-Pointer Cell growth experiments reveal excellent biocompatibiltiy of the host GaN material. Black-Right-Pointing-Pointer We present a biofunctionality assay using ionizing radiation. Black-Right-Pointing-Pointer DNA repair is utilized to evaluate material induced alterations in the cellular behavior. Black-Right-Pointing-Pointer GaN shows no bio-functional influence on the cellular environment. -- Abstract: There is an increasing interest in the integration of hybrid bio-semiconductor systems for the non-invasive evaluation of physiological parameters. High quality gallium nitride and its alloys show promising characteristics to monitor cellular parameters. Nevertheless, such applications not only request appropriate sensing capabilities but also the biocompatibility and especially the biofunctionality of materials. Here we show extensive biocompatibility studies of gallium nitride and, for the first time, a biofunctionality assay using ionizing radiation. Analytical sensor devices are used in medical settings, as well as for cell- and tissue engineering. Within these fields, semiconductor devices have increasingly been applied for online biosensing on a cellular and tissue level. Integration of advanced materials such as gallium nitride into these systems has the potential to increase the range of applicability for a multitude of test devices and greatly enhance sensitivity and functionality. However, for such applications it is necessary to optimize cell-surface interactions and to verify the biocompatibility of the semiconductor. In this work, we present studies of mouse fibroblast cell activity grown on gallium nitride surfaces after applying external noxa. Cell-semiconductor hybrids were irradiated with X-rays at air kerma doses up to 250 mGy and the DNA repair dynamics, cell proliferation, and cell growth dynamics of adherent cells were compared to control samples. The impact of ionizing radiation on DNA, along with the associated cellular repair mechanisms, is well characterized and serves as a reference tool for evaluation of substrate effects. The results indicate that gallium nitride does not require specific surface treatments to ensure biocompatibility and suggest that cell signaling is not affected by micro-environmental alterations arising from gallium nitride-cell interactions. The observation that gallium nitride provides no bio-functional influence on the cellular environment confirms that this material is well suited for future biosensing applications without the need for additional chemical surface modification.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Long-term low-dose α-particle enhanced the potential of malignant transformation in human bronchial epithelial cells through MAPK/Akt pathway

Highlights: • Multi-exposures of 25 mGy α-ray enhanced cell proliferation, adhesion, and invasion. • MAPK/Akt but not JNK/P66 was positively correlated with cell invasive phenotypes. • LDR of α-irradiation triggers cell malignant transformation through MAPK/Akt. - Abstract: Since the wide usage of ionizing radiation, the cancer risk of low dose radiation (LDR) (<0.1 Gy) has become attractive for a long time. However, most results are derived from epidemiologic studies on atomic-bomb survivors and nuclear accidents surrounding population, and the molecular mechanism of this risk is elusive. To explore the potential of a long-term LDR-induced malignant transformation, human bronchial epithelial cells Beas-2B were fractionally irradiated with 0.025 Gy α-particles for 8 times in total and then further cultured for 1–2 months. It was found that the cell proliferation, the abilities of adhesion and invasion, and the protein expressions of p-ERK, p-Akt, especially p-P38 were not only increased in the multiply-irradiated cells but also in their offspring 1–2 months after the final exposure, indicating high potentiality of cell malignant transformation. On opposite, the expressions of p-JNK and p-P66 were diminished in the subcultures of irradiated cells and thus may play a role of negative regulation in canceration. When the cells were transferred with p38 siRNA, the LDR-induced enhancements of cell adhesion and invasion were significantly reduced. These findings suggest that long-term LDR of α-particles could enhance the potential of malignant transformation incidence in human bronchial epithelial cells through MAPK/Akt pathway.

60 APPLIED LIFE SCIENCES↗

The potential benefits of nicaraven to protect against radiation-induced injury in hematopoietic stem/progenitor cells with relative low dose exposures

Highlights: • Nicaraven mitigated the radiation-induced reduction of c-kit{sup +} stem cells. • Nicaraven enhanced the function of hematopoietic stem/progenitor cells. • Complex mechanisms involved in the protection of nicaraven to radiation injury. - Abstract: Nicaraven, a hydroxyl radical-specific scavenger has been demonstrated to attenuate radiation injury in hematopoietic stem cells with 5 Gy γ-ray exposures. We explored the effect and related mechanisms of nicaraven for protecting radiation injury induced by sequential exposures to a relatively lower dose γ-ray. C57BL/6 mice were given nicaraven or placebo within 30 min before exposure to 50 mGy γ-ray daily for 30 days in sequences (cumulative dose of 1.5 Gy). Mice were victimized 24 h after the last radiation exposure, and the number, function and oxidative stress of hematopoietic stem cells were quantitatively estimated. We also compared the gene expression in these purified stem cells from mice received nicaraven and placebo treatment. Nicaraven increased the number of c-kit{sup +} stem/progenitor cells in bone marrow and peripheral blood, with a recovery rate around 60–90% of age-matched non-irradiated healthy mice. The potency of colony forming from hematopoietic stem/progenitor cells as indicator of function was completely protected with nicaraven treatment. Furthermore, nicaraven treatment changed the expression of many genes associated to DNA repair, inflammatory response, and immunomodulation in c-kit{sup +} stem/progenitor cells. Nicaraven effectively protected against damages of hematopoietic stem/progenitor cells induced by sequential exposures to a relatively low dose radiation, via complex mechanisms.

60 APPLIED LIFE SCIENCES↗

Influence of chronic low-dose/dose-rate high-LET irradiation from radium-226 in a human colorectal carcinoma cell line

Purpose: To evaluate potential damages of chronic environmentally relevant low-dose/dose-rate high-LET irradiation from a naturally occurring alpha-emitting radionuclide (radium-226, {sup 226}Ra) on a human colorectal carcinoma HCT116 p53{sup +/+} cell line. Methods: Clonogenic survival assays and mitochondrial membrane potential (MMP) measurement with a sensitive fluorescent MMP probe JC-1 were performed in HCT116 p53{sup +/+} cells chronically exposure to low doses/dose rates of {sup 226}Ra with high-LET. Comparisons were made with the human non-transformed keratinocyte HaCaT cell line and acute low-dose direct low-LET gamma radiation. Results and conclusion: The chronic low-dose/dose-rate alpha radiation (CLD/DRAR) did not reduce the clonogenic survival of HCT116 p53{sup +/+} cells over the period of 70 days of exposure. Only one significant reduction in the HCT116 p53{sup +/+} cells’ clonogenic survival was when cells were grown with 10,000 mBq/mL {sup 226}Ra for 40 days and progeny cells were clonogenically assessed in the presence of 10,000 mBq/mL {sup 226}Ra. The cumulative doses that cells received during this period ranged from 0.05 to 46.2 mGy. The mitochondrial membrane potential (MMP) dropped initially in both HCT116 p53{sup +/+} and HaCaT cells in response to CLD/DRAR. The MMP in HCT116 p53{sup +/+} cells recovered more quickly at all dose points than and that in HaCaT cells until the end of the exposure period. The highest dose rate of 0.66 mGy/day depolarized the HaCaT's mitochondria more consistently during the exposure period. The faster recovery status of the MMP in HCT116 p53{sup +/+} cells than that in HaCaT cells was also observed after exposure to acute low-dose gamma rays. Overall, it was found that CLD/DRAR had little impact on the MMP of human colorectal cancer and keratinocyte cell lines. - Highlights: • Human colorectal carcinoma HCT116 p53{sup +/+} and keratinocyte HaCaT cells were exposed to chronic low-dose/dose-rate alpha radiation (CLD/DRAR). • Unlike the HaCaT cells, HCT116 p53{sup +/+} cells’ clonogenic survival and mitochondrial membrane potential (MMP) changed little upon CLD/DRAR. • Upon the mitochondrial membrane depolarization response induced by CLD/DRAR, HaCaT cells were more sensitive than HCT116 p53{sup +/+}. • Gamma radiation depolarized the mitochondria of both HaCaT and HCT116 p53{sup +/+} in a dose-dependent manner. • The MMP in HCT116 p53{sup +/+} could recover more quickly than that in HaCaT cells after an acute low-dose gamma irradiation challenge.

54 ENVIRONMENTAL SCIENCES↗

Absorbed Doses and Risk Estimates of {sup 211}At-MX35 F(ab'){sub 2} in Intraperitoneal Therapy of Ovarian Cancer Patients

Purpose: Ovarian cancer is often diagnosed at an advanced stage with dissemination in the peritoneal cavity. Most patients achieve clinical remission after surgery and chemotherapy, but approximately 70% eventually experience recurrence, usually in the peritoneal cavity. To prevent recurrence, intraperitoneal (i.p.) targeted α therapy has been proposed as an adjuvant treatment for minimal residual disease after successful primary treatment. In the present study, we calculated absorbed and relative biological effect (RBE)-weighted (equivalent) doses in relevant normal tissues and estimated the effective dose associated with i.p. administration of {sup 211}At-MX35 F(ab'){sub 2}. Methods and Materials: Patients in clinical remission after salvage chemotherapy for peritoneal recurrence of ovarian cancer underwent i.p. infusion of {sup 211}At-MX35 F(ab'){sub 2}. Potassium perchlorate was given to block unwanted accumulation of {sup 211}At in thyroid and other NIS-containing tissues. Mean absorbed doses to normal tissues were calculated from clinical data, including blood and i.p. fluid samples, urine, γ-camera images, and single-photon emission computed tomography/computed tomography images. Extrapolation of preclinical biodistribution data combined with clinical blood activity data allowed us to estimate absorbed doses in additional tissues. The equivalent dose was calculated using an RBE of 5 and the effective dose using the recommended weight factor of 20. All doses were normalized to the initial activity concentration of the infused therapy solution. Results: The urinary bladder, thyroid, and kidneys (1.9, 1.8, and 1.7 mGy per MBq/L) received the 3 highest estimated absorbed doses. When the tissue-weighting factors were applied, the largest contributors to the effective dose were the lungs, stomach, and urinary bladder. Using 100 MBq/L, organ equivalent doses were less than 10% of the estimated tolerance dose. Conclusion: Intraperitoneal {sup 211}At-MX35 F(ab'){sub 2} treatment is potentially a well-tolerated therapy for locally confined microscopic ovarian cancer. Absorbed doses to normal organs are low, but because the effective dose potentially corresponds to a risk of treatment-induced carcinogenesis, optimization may still be valuable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synthesis and study on the luminescence properties of cadmium borate phosphors

Highlights: • Cadmium borate synthesized by solid state sintering technique. • Neutron sensitivity of the material ten times that of TLD-600. • Gamma sensitivity is found to be twice that of TLD-100. • Gamma response is linear from 0.1 to 10{sup 3} mGy. - Abstract: Cadmium borate compound prepared through wet chemical reaction from the starting chemicals followed by high temperature solid state synthesis below the melting point to get the final TL phosphor powder. Phase purity and bond details of cadmium borate crystals are characterized using X-ray diffraction technique and infrared spectroscopy. Feasibility of these materials for radiation dosimetry applications was studied after gamma and neutron irradiation. Gamma irradiation of undoped phosphors show a single peak around 185 °C whereas doping with gadolinium and silver, new more intense peak observed at 290 °C. Irradiation to thermal neutrons revealed single peak around 170 °C for all the phosphors. TL emission spectra and photoluminescence (PL) studies were also carried out on the phosphors. These borate materials are found to be highly sensitive to neutrons and hence can be used for neutron detection. Neutron sensitivity of the material is about ten times that of TLD-600.

36 MATERIALS SCIENCE↗

Luminescence properties of Eu{sup 2+} doped SrB{sub 4}O{sub 7} phosphor for radiation dosimetry

Highlights: • Report TL/OSL properties of SrB{sub 4}O{sub 7}:Eu{sup 2+} under beta irradiations. • OSL Sensitivity was about 33% than that of commercially available α-Al{sub 2}O{sub 3.} • TL glow peaks was appear at 305° C and TL sensitivity about 200 times higher than TLD-500. • OSL decay pattern was faster than α- Al{sub 2}O{sub 3}:C and dose response was linear nature. - Abstract: In this report, we presented the TL/OSL properties of Eu doped SrB{sub 4}O{sub 7} phosphor under β-irradiation. This phosphor was synthesized by using solid state method. The phosphor shows OSL sensitivity about 33% than that of commercially available α-Al{sub 2}O{sub 3}: C phosphor. CW-OSL curve possess two components having photoionization cross-sections 0.707 × 10{sup −17} and 18.58 × 10{sup −17} cm{sup 2} respectively and TL sensitivity about 200 times higher than TLD-500. The kinetic parameters such as activation energy, frequency factor and order of kinetics of TL curve were calculated by using peak shape method. In TL/OSL mode dose-response was almost linear in the range of measurements. The MDD was found to be 1.26 mGy with 3σ of background. Also reusability studies showed the phosphor can be reused for 10 cycles with 1% change in the OSL output. The PL spectra of SrB{sub 4}O{sub 7} showed emission in NUV region when excited with 318 nm under UV source.

36 MATERIALS SCIENCE↗

Fat to muscle ratio measurements with dual energy x-ray absorbtiometry

Accurate measurement of the fat-to-muscle ratio in animal model is important for obesity research. In addition, an efficient way to measure the fat to muscle ratio in animal model using dual-energy absorptiometry is presented in this paper. A radioactive source exciting x-ray fluorescence from a target material is used to provide the two x-ray energies needed. The x-rays, after transmitting through the sample, are measured with an energy-sensitive Ge detector. Phantoms and specimens were measured. The results showed that the method was sensitive to the fat to muscle ratios with good linearity. A standard deviation of a few percent in the fat to muscle ratio could be observed with the x-ray dose of 0.001 mGy.

36 MATERIALS SCIENCE↗

Radiation hardness and precision timing study of silicon detectors for the CMS High Granularity Calorimeter (HGC)

The high luminosity upgraded LHC or Phase-II is expected to increase the instantaneous luminosity by a factor of 10 beyond the LHC's design value, expecting to deliver 250 fb –1 per year for a further 10 years of operation. Under these conditions the performance degradation due to integrated radiation dose will need to be addressed. The CMS collaboration is planning to upgrade the forward calorimeters. The replacement is called the High Granularity Calorimeter (HGC) and it will be realized as a sampling calorimeter with layers of silicon detectors interleaved. The sensors will be realized as pad detectors with sizes of less that ~1.0 cm 2 and an active thickness between 100 and 300 μm depending on the position, respectively, the expected radiation levels. For an integrated luminosity of 3000 fb –1 , the electromagnetic calorimetry will sustain integrated doses of 1.5 MGy (150 Mrads) and neutron fluences up to 10 16 neq/cm 2 . A radiation tolerance study after neutron irradiation of 300, 200, and 100 μm n-on-p and p-on-n silicon pads irradiated to fluences up to 1.6×10 16 neq/cm 2 is presented. In this work, the properties of these diodes studied before and after irradiation were leakage current, capacitance, charge collection efficiency, annealing effects and timing capability. The results of these measurements validate these sensors as candidates for the HGC system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge collection study with the ATLAS ITk prototype silicon strip sensors ATLAS17LS

The inner tracker of the ATLAS detector is scheduled to be replaced by a completely new silicon-based inner tracker (ITk) for the Phase-II of the CERN LHC (HL-LHC). The silicon strip detector covers the volume 40 < R < 100 cm in the radial and | z | < 300 cm in the longitudinal directions. The silicon sensors for the detector will be fabricated using the n + -on-p 6-inch wafer technology, for a total of 22,000 wafers. Here, intensive studies were carried out on the final prototype sensors ATLAS17LS fabricated by Hamamatsu Photonics (HPK). The charge collection properties were examined using penetrating 90 Sr β -rays and the ALIBAVA fast readout system for the miniature sensors of 1 cm × 1 cm in area. The samples were irradiated by protons in the 27 MeV Birmingham Cyclotron, the 70 MeV CYRIC at Tohoku University, and the 24 GeV CERN-PS, and by neutrons at Ljubljana TRIGA reactor for fluence values up to 2 × 10 15 n eq /cm 2 . The change in the charge collection with fluence was found to be similar to the previous prototype ATLAS12, and acceptable for the ITk. Sensors with two active thicknesses, 300 μ m (standard) and 240 μ m (thin), were compared and the difference in the charge collection was observed to be small for bias voltages up to 500 V. Some samples were also irradiated with gamma radiation up to 2 MGy, and the full depletion voltage was found to decrease with the dose. This was caused by the Compton electrons due to the 60 Co gamma radiation. To summarize, the design of the ATLAS17LS and technology for its fabrication have been verified for implementation in the ITk. We are in the stage of sensor pre-production with the first sensors already delivered in January of 2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the polysilicon resistor in silicon strip sensors for ATLAS inner tracker as a function of temperature, pre- and post-irradiation

The high luminosity upgrade of the Large Hadron Collider, foreseen for 2029, requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker (ITk). The expected ultimate total integrated luminosity of 4000 fb –1 means that the strip part of the ITk detector will be exposed to the total particle fluences and ionizing doses reaching the values of 1.6 · 10 15 1 MeV n eq /cm 2 and 0.66 MGy, respectively, including a safety factor of 1.5. Radiation hard n + -in-p micro-strip sensors were developed by the ATLAS ITk strip collaboration and are produced by Hamamatsu Photonics K.K. The active area of each ITk strip sensor is delimited by the n-implant bias ring, which is connected to each individual n + implant strip by a polysilicon bias resistor. The total resistance of the polysilicon bias resistor should be within a specified range to keep all the strips at the same potential, prevent the signal discharge through the grounded bias ring and avoid the readout noise increase. While the polysilicon is a ubiquitous semiconductor material, the fluence and temperature dependence of its resistance is not easily predictable, especially for the tracking detector with the operational temperature significantly below the values typical for commercial microelectronics. Dependence of the resistance of polysilicon bias resistor on the temperature, as well as on the total delivered fluence and ionizing dose, was studied on the specially-designed test structures called ATLAS Testchips, both before and after their irradiation by protons, neutrons, and gammas to the maximal expected fluence and ionizing dose. The resistance has an atypical negative temperature dependence. It is different from silicon, which shows that the grain boundary has a significant contribution to the resistance. Finally, we discuss the contributions by parameterizing the activation energy of the polysilicon resistance as a function of the temperature for unirradiated and irradiated ATLAS Testchips.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation-induced molecular hydrogen gas generation in the presence of aluminum alloy 1100

The United States government currently manages nearly 13 metric tons of aluminum-clad spent nuclear fuel (SNF) without a long-term storage solution, so a fundamental understanding of corrosion processes occurring on aluminum alloy surfaces is of utmost importance to plan for extended (>50 years) interim dry storage of aluminum-clad SNF. While thermal and chemical corrosion processes are well characterized for aluminum, radiation effects are not. To help understand the impacts of radiation on aluminum-clad SNF, here the radiation-induced molecular hydrogen gas (H 2 ) generation from pristine and pre-corroded aluminum alloy 1100 (Al-1100) coupons have been studied. Corrosion of coupons was achieved by submerging coupons in water at 95 °C for 29 days, yielding a ~5 μm boehmite/bayerite oxide film. Pre-corroded coupons were exposed to cobalt-60 gamma radiation to absorbed doses of up to 1.0 MGy under a variety of conditions: cover-gas composition (argon, nitrogen, or air), relative humidity (0, 50, and 100%), and temperature (ambient, 100, and 200 °C). Post-irradiation measurements demonstrated that the yield of H 2 was directly attributable to the presence of the Al-1100 coupons and their physisorbed water with dependence on absorbed gamma dose, relative humidity, and cover-gas composition. No H 2 was quantified in the presence of air, while both nitrogen and argon environments afforded higher H 2 yields with increasing relative humidities. This was attributed to the greater availability of adsorbed water for radiolytic processes. Irradiation of pre-corroded Al-1100 coupons at different temperatures under 0% relative humidity argon conditions yielded statistically equivalent H 2 yields for ambient temperatures and 100 °C. However, irradiation at 200 °C promoted a 3 to 4-fold increase in the yield of H 2 , possibly due to the transformation of bayerite to boehmite and/or improved efficiency of H • and H 2 release from oxide surfaces.

36 MATERIALS SCIENCE↗

Laboratory-Based Cryogenic Soft X-ray Tomography with Correlative Cryo-Light and Electron Microscopy

Here we present a novel laboratory-based cryogenic soft X-ray microscope for whole cell tomography of frozen hydrated samples. We demonstrate the capabilities of this compact cryogenic microscope by visualizing internal sub-cellular structures of Saccharomyces cerevisiae cells. The microscope is shown to achieve better than 50 nm spatial resolution with a Siemens star test sample. For whole biological cells, the microscope can image specimens up to 5 micrometers thick. Structures as small as 90 nm can be detected in tomographic reconstructions at roughly 70 nm spatial resolution following a low cumulative radiation dose of only 7.2 MGy. Furthermore, the design of the specimen chamber utilizes a standard sample support that permits multimodal correlative imaging of the exact same unstained yeast cell via cryo-fluorescence light microscopy, cryo-soft x-ray microscopy and cryo-transmission electron microscopy. This completely laboratory-based cryogenic soft x-ray microscope will therefore enable greater access to three-dimensional ultrastructure determination of biological whole cells without chemical fixation or physical sectioning.

Compact light source↗

Materials Synthesis Insights from Scientific Literature via Text Extraction and Machine Learning

In the past several years, Materials Genome Initiative (MGI) efforts have produced myriad examples of computationally designed materials in the fields of energy storage, catalysis, thermoelectrics, and hydrogen storage as well as large data resources that are used to screen for potentially transformative compounds. The bottleneck in high-Throughput materials design has thus shifted to materials synthesis, which motivates our development of a methodology to automatically compile materials synthesis parameters across tens of thousands of scholarly publications using natural language processing techniques. To demonstrate our framework's capabilities, we examine the synthesis conditions for various metal oxides across more than 12 thousand manuscripts. We then apply machine learning methods to predict the critical parameters needed to synthesize titania nanotubes via hydrothermal methods and verify this result against known mechanisms. Lastly, we demonstrate the capacity for transfer learning by using machine learning models to predict synthesis outcomes on materials systems not included in the training set and thereby outperform heuristic strategies.

36 MATERIALS SCIENCE↗

Radiation Effects on the Performance of Advanced Sulfur Monochloride Chlorination Processes

Advanced sulfur chloride-based chlorination technologies are being developed to enable efficient recycling of aluminum and zirconium-based materials used in the nuclear industry. However, the impacts of ionizing radiation on the performance of these sulfur chloride compounds are not well established, despite this being critical knowledge for assessing their feasibility and longevity under envisioned process conditions. Here, in the present article, we report on the effects of cobalt-60 gamma irradiation (≤ 5 MGy) on the aluminum alloy 6061 (AA6061-T6) chlorination yield in sulfur monochloride (S 2 Cl 2 ). Our findings indicate that, compared to nonirradiated solvent, radiation-induced changes in the chemical composition of S 2 Cl 2 —identified using Raman spectroscopy—afford an additional, dose-dependent exothermic process prior to the chlorination reaction’s typical thermodynamic behavior. We attribute this new process to reactions involving aluminum species (metal, oxide, or [oxy]hydroxides) and sulfur dichloride (SCl 2 ), an S 2 Cl 2 radiolysis product that accumulates with absorbed gamma dose, but is absent following an AA6061-T6 chlorination study. Despite the exothermicity of this new process, the overall yield of chlorination decreased with increasing preirradiation dose. Consequently, the chemical reactivity, specificity (aluminum metal vs aluminum passivation and corrosion layer constituents), and byproducts of SCl 2 must be more thoroughly evaluated to support the continued development of advanced S 2 Cl 2 chlorination technologies.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Performance of an i -SANEX System Based on a Water-Soluble BTP under Continuous Irradiation in a γ-Radiolysis Test Loop

Here, the i -SANEX solvent formulation consisting of nominally 0.2 M TODGA/5% 1-octanol/dodecane was γ-irradiated under realistic conditions in the Idaho National Laboratory radiolysis test loop, in contact with both extraction and stripping aqueous phases. The extraction aqueous phase was 4.5 M HNO 3 , and the stripping aqueous phase was 0.018 M SO 3 –Ph–BTP/0.35 M HNO 3 . When irradiated in contact with only the 4.5 M HNO 3 phase, the TODGA solvent maintained excellent extraction performance for americium, cerium, europium, and neodymium to a maximum absorbed dose of nearly 0.9 MGy. The results for preliminary static, batch irradiations were consistent with test loop findings. When the aqueous phase was changed to that containing the aqueous soluble BTP, the irradiated aqueous phase showed a dramatic color change, but this does not appear to have had adverse effect on solvent extraction performance. The distribution ratios for both the lanthanides and actinides were invariant with absorbed dose, and the separation factors were essentially unchanged to a maximum absorbed dose of 174 kGy. The results of inductively coupled plasma mass spectrometry analysis of the aqueous and organic phases showed that ruthenium and strontium were not extracted in the presence of the irradiated BTP-aqueous phase. Molybdenum was extracted under both conditions. Further, the buildup of corrosion products of stainless steel in the presence of the BTP was not dramatically greater than in the nitric acid-only system. Phase separation times were not adversely affected by irradiation for either system. The results presented here indicate that the performance of the TODGA/SO 3 –Ph–BTP, i -SANEX process under test loop radiolysis is much better than expected based on a literature report using single-phase batch irradiation experiments, and better than might be predicted based on diglycolamide radiolysis studies alone.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Effects of He-Ion Radiation on Solid-State Uranyl Nitrate Compounds under Dry and Hydrated Atmospheric Conditions

Radioactive decay of uranium (U) and its related daughter/fission products emit ionizing radiation, including γ (γ) rays and α (α) particles, that result in the formation of radical species and induce chemical reactivity in materials. While radioactivity is inherent to the chemistry of U there are limited studies that detail changes at an atomistic level. Here, this work describes the He-ion radiolysis of four solid-state U(VI) species: [UO 2 (NO 3 ) 2 ]·3(H 2 O) and M[UO 2 (NO 3 ) 3 ] (M = K + , Rb + , Cs + ). These materials were irradiated under different conditions (i.e. closed, open – Ar gas, or open – H 2 O-saturated Ar gas) to further evaluate the impact of water radiolysis on the chemical modification of these materials. Pre- and post-irradiation analyses were conducted using EPR, Raman, and ATR-IR spectroscopy on materials irradiated to 0, 5, 10, and 25 MGy. The results indicated the presence of nitrate radical (NO 3 • ) formation in all solid-state materials with similarities to those observed in γ-radiation studies. Irradiation of [UO 2 (NO 3 ) 2 ]·3(H 2 O) did not show evidence of reactive oxygen species bound to the U(VI) cation under inert conditions; however, surface reactivity was observed for samples irradiated in the H 2 O-saturated environment. Similar chemical changes were observed in the uranyl trinitrato compounds irradiated in the presence of H 2 O vapor and there were observed differences in the reactivity depending on the identity of the alkali cation.